MWMichael Wojcik

Michael Wojcik

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Michael Wojcik has a total of 98 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Structured illumination for surface-resolved grazing-incidence X-ray scattering

    by Doğa Gürsoy, Xiaogang Yang, Dina Sheyfer, Michael Wojcik, Ruipeng Li, Esther H. R. Tsai

    Grazing-incidence (GI) scattering techniques are widely used to characterize thin films, offering high surface sensitivity and insight into morphology and structure. However, these approaches typically provide statistical averaged information due to elongated footprint or limited spatial resolution due to beam size. Here we introduce a method that combines structured illumination with GI X-ray scattering and leverages our computational imaging approach to resolve local structural details. We demonstrate that our method captures local features of an organic semiconductor thin film without the need for sample rotation as in tomography. The method expands GI techniques from statistical averaging to high-resolution imaging, thereby providing the capability for detailed analysis of local material properties, such as domain shape, orientation and polymorphism, which are critical for advancing material design towards more efficient and tailored materials.

  • Optimizing coded-apertures for depth-resolved diffraction

    by D. Gürsoy, D. Sheyfer, M. Wojcik, W. Liu, J. Tischler

    Coded apertures, initially developed for x-ray astronomy, are gaining traction as a means of enabling depth-resolved imaging in synchrotron-based diffraction experiments. In this study, we evaluate their application to microscale diffraction, focusing on how design and acquisition parameters influence the ability to reconstruct depth-dependent scattering signals. Through systematic simulations, we investigate the impact of bit size, aperture thickness, scan length, and local pattern characteristics on the accuracy of position and signal recovery. We introduce metrics to quantify reconstruction success and identify trade-offs among design variables. Experimental validation using a synchrotron-based micro-diffraction setup confirms the key trends observed in simulation, demonstrating that a moderate scan length and mask aspect ratio suffice for robust signal recovery, even under noisy conditions. Our findings provide a framework for implementing coded apertures in various diffraction geometries, offering a scalable and sample-motion-free approach to 3D structural characterization, particularly relevant for new synchrotron facilities.

  • Open Access

    Crack formation in strained β-(AlxGa1−x)2O3 films grown on (010) β-Ga2O3 substrates

    by Dorian P. Luccioni, Kenny Huynh, Michael E. Liao, Brandon Carson, Marko J. Tadjer, James S. Lundh, Kohei Sasaki, Keita Konishi, Hannah N. Masten, XianRong Huang, et al.

    The cracking and local strain relaxation in (010) (AlxGa1−x)2O3 films grown on Ga2O3 substrates are assessed in terms of film composition and thickness. We utilize x-ray diffraction and electron microscopy techniques combined with simulation and modeling to investigate that film cracking on curvature (flatness) has a directly proportional relationship with film thickness and/or aluminum content. Cross section transmission electron microscopy reveals that cracks along both the (001) and (100) cleavage planes penetrate into the substrate. The diffuse scattered intensity observed in reciprocal space maps (RSMs) is directly correlated with the tilt that is introduced due to the change in the deformation conditions near the cracks. While asymmetric RSMs show that the layers are fully strained, the diffuse scattering distribution in reciprocal space can be interpreted to show that the cracking relaxes and locally tilts the lattice ∼350 nm from the crack edges, which is consistent with the larger radius of curvature associated with the films with higher crack densities. For example, a 200 nm (Al0.13Ga0.87)2O3 thick film has an average inter-crack spacing of 3.3 µm, so most of the epitaxial layer is fully strained except near the cracks where it deforms elastically and is consistent with the gallium oxide Poisson ratio. A reciprocal space model was developed, which imports the strain and tilt distributions (based on finite element modeling) to match the features observed in the experimental maps. We also note that previous studies involving (AlxGa1−x)2O3 films may show evidence of cracking as observed in their symmetric and asymmetric RSMs.


  • Open Access

    Nano-laminography with a transmission X-ray microscope

    by Viktor Nikitin, Alberto Mittone, Samuel J. Clark, Kamel Fezzaa, Michael Wojcik, Alex Deriy, Sunil Bean, Francesco De Carlo

    Nano-laminography combines the penetrating power of hard X-rays with a tilted rotational geometry to deliver high-resolution, three-dimensional images of laterally extended, flat specimens that are otherwise incompatible with, or difficult to image using, conventional nano-tomography. In this work, we demonstrate a full-field, X-ray nano-laminography system implemented with the transmission X-ray microscope at beamline 32-ID of the upgraded Advanced Photon Source at Argonne National Laboratory, USA. By rotating the sample around an axis inclined by 20° to the incident beam, the technique minimizes the long optical path lengths that would otherwise generate excessive artifacts when planar samples are imaged edge-on. The efficiency of the technique is demonstrated with 50 nm spatial resolution and minute-scale temporal resolution 3D imaging of a planar integrated circuit sample and targeted imaging of an individual particle within a powder sample, where mounting procedures are typically challenging in regular nano-tomography. The sample mounting strategy, data acquisition, and reconstruction method will also be discussed.


  • Open Access

    Measurements of source emittance and beam coherence properties of the upgraded Advanced Photon Source

    by Xianbo Shi, Yu-Chung Lin, Jiyong Zhao, Thomas Toellner, Michael Y. Hu, Soenke Seifert, Byeongdu Lee, Walan Grizolli, Michael J. Wojcik, Luca Rebuffi, et al.

    The Advanced Photon Source (APS) has been upgraded with a multi-bend achromat lattice, achieving significantly reduced electron beam emittance and enhanced X-ray coherence. Precise characterization of these properties is essential for optimizing beamline performance and enabling new experiments that take full advantage of the upgraded source. We report on measurements of source size and transverse coherence properties using grating interferometry at two beamlines: the APS 3-ID-B undulator beamline and the 1-BM-B bending magnet beamline. The results confirm the world-record horizontal emittance of the upgraded APS below 30 pm rad and validate the theoretical design parameters. We further investigate the impact of optical aberrations and mechanical vibrations at the 12-ID-C beamline on coherence preservation. These measurements establish a benchmark for future beamline enhancements and demonstrate the effectiveness of grating interferometry for high-precision beam characterization. Our findings provide critical insights into synchrotron beam dynamics, coherence degradation mechanisms, and strategies for optimizing beamline X-ray optics at next-generation light sources.


  • Coded-mask-based wavefront sensing technique for APS nanofocusing beamline diagnostics

    by Xianbo Shi, Zhi Qiao, Matthew J. Highland, Matthew G. Frith, Luca Rebuffi, Michael J. Wojcik, Lahsen Assoufid

    We extend our recently developed coded-mask wavefront sensing technique to enable single-shot measurements of nanofocused x-ray beams. This method accurately reconstructs the focal beam profile by backpropagating the wavefront measured downstream of the beam focus. To validate its performance, we benchmarked it against the conventional fluorescence wire scan method, successfully measuring ∼120 nm focal spots at the 28-ID-B beamline of the Advanced Photon Source using a polymeric compound refractive lens. The results highlight the effectiveness of coded-mask wavefront sensing for high-precision beam profiling and its application as a real-time wavefront monitoring tool.


  • Open Access

    Dark-field X-ray microscopy with structured illumination for three-dimensional imaging

    by Doğa Gürsoy, Kaan Alp Yay, Elliot Kisiel, Michael Wojcik, Dina Sheyfer, Arndt Last, Matthew Highland, Ian Randal Fisher, Stephan Hruszkewycz, Zahir Islam

    Dark-field X-ray microscopy is a lens-based technique that enables real-space imaging of heterogeneous micro- and meso-scale ordered materials. However, achieving accurate three-dimensional (3D) reconstruction often requires meticulous sample alignment or rastering, requiring complex rotational setups and extended acquisition times. To address these challenges, we introduce a structured illumination technique optimized for 3D imaging of ordered materials at sub-micrometer length scales. Our approach employs a coded aperture to spatially modulate the incident X-ray beam, enabling 3D structural reconstruction from images captured at various aperture positions. Unlike current 3D imaging approaches, which often rely on rotational or rastering methods, our technique uses scanning X-ray silhouettes of the coded aperture for depth resolution along the diffraction axis. This eliminates the need for sample rotation or rastering, resulting in a highly stable and efficient imaging modality. We validated the efficacy of this approach through experimental imaging of an isolated twin domain within a bulk single crystal of an iron pnictide using a dark-field X-ray microscope. This advancement aligns with the enhanced brightness upgrades of modern synchrotron radiation facilities, unlocking new possibilities for high-resolution imaging of ordered materials.


  • Open Access

    Three-dimensional hard X-ray ptychographic reflectometry imaging on extended mesoscopic surface structures

    by Peco Myint, Ashish Tripathi, Michael J. Wojcik, Junjing Deng, Mathew J. Cherukara, Nicholas Schwarz, Suresh Narayanan, Jin Wang, Miaoqi Chu, Zhang Jiang

    Many nanodevices and quantum devices, with their sizes often spanning from millimeters down to sub-nanometer, have intricate low-dimensional, non-uniform, or hierarchical structures on surfaces and interfaces. Since their functionalities are dependent on these structures, high-resolution surface-sensitive characterization becomes imperative to gain a comprehensive understanding of the function–structure relationship. We thus developed hard x-ray ptychographic reflectometry imaging, a new technique that merges the high-resolution two-dimensional imaging capabilities of hard x-ray ptychography for extended objects, with the high-resolution depth profiling capabilities of x-ray reflectivity for layered structures. The synergy of these two methods fully leverages both amplitude and phase information from ptychography reconstruction to not only reveal surface topography and localized structures, such as shapes and electron densities, but also yields statistical details, such as interfacial roughness that is not readily accessible through coherent imaging solely. The hard x-ray ptychographic reflectometry imaging is well-suited for three-dimensional imaging of mesoscopic samples, particularly those comprising planar or layered nanostructures on opaque supports, and could also offer a high-resolution surface metrology and defect analysis on semiconductor devices, such as integrated nanocircuits and lithographic photomasks for microchip fabrications.


  • Open Access

    Increased spatial coherence length from an asymmetric crystal reflection at grazing exit

    by Albert Macrander, Xianbo Shi, Walan Grizzoli, Xianrong Huang, Nino Pereira, Michael Wojcik, Lahsen Assoufid

    Coherent X-ray imaging is an active field at synchrotron sources. The images rely on the available coherent flux over a limited field of view. At many synchrotron beamlines a double-crystal monochromator (DCM) is employed in a standard nondispersive arrangement. For coherent diffraction imaging it is advantageous to increase the available field of view by increasing the spatial coherence length (SCL) of a beam exiting such a DCM. Here, Talbot interferometry data together with ray-tracing simulations for a (+ − − +) four-reflection experimental arrangement are presented, wherein the first two reflections are in the DCM and the final fourth reflection is asymmetric at grazing exit. Analyses of the interferometry data combined with the simulations show that compared with the beam exiting the DCM a gain of 76% in the SCL was achieved, albeit with a factor of 20 reduction in flux density, which may not be a severe penalty at a synchrotron beamline. Previous efforts reported in the literature to increase the SCL that employed asymmetric crystal diffraction at grazing incidence are also discussed. A much reduced SCL is found presently in simulations wherein the same asymmetric crystal is set for grazing incidence instead of grazing exit. In addition, the present study is compared and contrasted with two other means of increasing the SCL. These are (i) focusing the beam onto an aperture to act as a secondary source, and (ii) allowing the beam to propagate in vacuum an additional distance along the beamline.


  • Dissolution of Mg-enriched defects in implanted GaN and increased p-type dopant activation

    by K. Huynh, Y. Wang, M. E. Liao, J. Tweedie, P. Reddy, M. H. Breckenridge, R. Collazo, Z. Sitar, K. Sierakowski, M. Bockowski, et al.

    Annealing Mg-implanted homoepitaxial GaN at temperatures above 1400 °C eliminates the formation of inversion domains and leads to improved dopant activation efficiency. Extended defects, in the form of inversion domains, contain electrically inactive Mg after post-implantation annealing at temperatures as high as 1300 °C (one GPa N2 overpressure), which results in a low dopant activation efficiency. Triple-axis x-ray data reveal that implant-induced strain is fully relieved after annealing at 1300 °C for 10 min, indicating that strain-inducing point defects formed during implantation have reconfigured and inversion domains are formed. However, annealing at temperatures of 1400–1500 °C (one GPa N2 overpressure) eliminates the presence of the inversion domains. While residual defects, such as dislocation loops, still exist after annealing at and above 1400 °C, chemical analysis at multiple dislocation loops shows no sign of Mg segregation. Meanwhile, an overall decreasing trend in the dislocation loop density is observed after annealing at the higher temperatures and longer times. Additionally, once inversion domains are formed and the samples are cooled to room temperature, they are shown to dissolve with subsequent annealing above 1400 °C. While such defects have been observed before, the important finding that such defects can be dissolved with a short, higher temperature step is key. Earlier work [Breckenridge et al., J. Appl. Phys. Lett. 118, 022101 (2021)] addressing electrical measurements of these types of samples showed that annealing at 1400 °C leads to a dopant activation efficiency that is an order of magnitude higher than that observed at 1300 °C. This work complements earlier work by identifying the inversion domains, which incorporate Mg, and points to the benefits, in terms of defect density and p-type dopant activation, of using higher temperature (>1400 °C) annealing cycles to activate Mg in GaN, even if the Mg-containing inversion domains had been formed during lower temperature annealing.