Denis Tack
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Denis Tack has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Pierre Alain Gevenois
Department of Radiology, Hôpital Erasme, Université Libre de Bruxelles, Brussels, Belgium
2 shared publications Alain van Muylem
1 shared publicationArnaud Cornil
1 shared publication- Caroline Keyzer
Hôpital Erasme, Université Libre de Bruxelles
1 shared publication Elodie Gyssels
Department of Radiology, Epicura, Clinique Luis Caty, Baudour Departments of †Pneumology §Radiology, Hôpital Erasme, Brussels, Belgium ‡Department of Radiology, Clinique des Grangettes, Chêne-Bougeries, Switzerland
1 shared publication- Nigel Howarth
Hirslanden-Clinique des Grangettes, Genève
1 shared publication
Latest Publications
- 1 January 2016
- Published by Wolters Kluwer Health in Journal of Thoracic Imaging
- Vol. 31 (1) , 23-28
Chest Computed Tomography Radiation Dose Optimization
Purpose: The aim of the study was to compare radiation dose and image quality between the "average" and the "very strong" automatic exposure control (AEC) strength curves. Materials and Methods: Images reconstructed with filtered backprojection techniques and radiation dose data of unenhanced helical chest computed tomography (CT) examinations obtained at 2 hospitals (hospital A, hospital B) using the same scanner devices and acquisition protocols but different AEC strength curves were evaluated over a 3-month period. The selected AEC strength curve applied to "slim" patients (diameter <32cm estimated from the attenuation automatically measured on the topogram) was "average" and "very strong" in hospital A and hospital B, respectively. Two radiologists with 13 and 24 years of experience scored the image quality of the lung parenchyma and the mediastinum on a 5-point scale. The patients' effective diameter, the delivered CT dose index volume, and dose-length products were recorded. Results: A total of 410 patients were included. The average body mass index was 24.0 kg/m2 in hospital A and 24.8 kg/m2 in hospital B. There was no significant difference between hospitals with respect to age, sex ratio, weight, height, body mass index, effective diameters, and image quality scores for each radiologist (P ranging from 0.050 to 1.000). The mean CT dose index volume for the entire population was 2.0mGy and was significantly lower in hospital B with the "very strong" AEC curve as compared with hospital A (-11%, P=0.001). The mean dose-length product delivered in this 70 kg-weight population was 68mGycm, corresponding to an effective dose of 0.95 mSv. Conclusion: Changing the AEC strength curve from "average" to "very strong" for slim patients maintains image quality and reduces the radiation dose to <1mSv in routine chest CT examinations reconstructed with filtered back-projection techniques.SCOPUS: ar.jinfo:eu-repo/semantics/publishe
- 1 January 2016
- Published by Wolters Kluwer Health in Journal of Thoracic Imaging
- Vol. 31 (1) , 23-28
Chest Computed Tomography Radiation Dose Optimization
Purpose: The aim of the study was to compare radiation dose and image quality between the "average" and the "very strong" automatic exposure control (AEC) strength curves. Materials and Methods: Images reconstructed with filtered backprojection techniques and radiation dose data of unenhanced helical chest computed tomography (CT) examinations obtained at 2 hospitals (hospital A, hospital B) using the same scanner devices and acquisition protocols but different AEC strength curves were evaluated over a 3-month period. The selected AEC strength curve applied to "slim" patients (diameter <32cm estimated from the attenuation automatically measured on the topogram) was "average" and "very strong" in hospital A and hospital B, respectively. Two radiologists with 13 and 24 years of experience scored the image quality of the lung parenchyma and the mediastinum on a 5-point scale. The patients' effective diameter, the delivered CT dose index volume, and dose-length products were recorded. Results: A total of 410 patients were included. The average body mass index was 24.0 kg/m2 in hospital A and 24.8 kg/m2 in hospital B. There was no significant difference between hospitals with respect to age, sex ratio, weight, height, body mass index, effective diameters, and image quality scores for each radiologist (P ranging from 0.050 to 1.000). The mean CT dose index volume for the entire population was 2.0mGy and was significantly lower in hospital B with the "very strong" AEC curve as compared with hospital A (-11%, P=0.001). The mean dose-length product delivered in this 70 kg-weight population was 68mGycm, corresponding to an effective dose of 0.95 mSv. Conclusion: Changing the AEC strength curve from "average" to "very strong" for slim patients maintains image quality and reduces the radiation dose to <1mSv in routine chest CT examinations reconstructed with filtered back-projection techniques.SCOPUS: ar.jinfo:eu-repo/semantics/publishe
- 1 January 2011
- Published by Springer Nature
- p. 317-337
Dose Optimization and Reduction in MDCT of the Abdomen
- 1 January 2011
- Published by Springer Nature
- p. 317-337
Dose Optimization and Reduction in MDCT of the Abdomen
- 1 January 2011
- Published by Springer Nature
- p. 307-315
Dose Reduction and Optimization in Computed Tomography of the Chest
- 1 January 2011
- Published by Springer Nature
- p. 307-315
Dose Reduction and Optimization in Computed Tomography of the Chest
- 1 August 2003
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 181 (2) , 331-334
Dose Reduction in Multidetector CT Using Attenuation-Based Online Tube Current Modulation
OBJECTIVE. This study was designed to quantify the radiation dose saved by attenuation-based online tube current modulation applied to multidetector CT (MDCT) of the adult trunk as a function of effective milliampere-second (mAs) presets, sex, and body habitus. SUBJECTS AND METHODS. One hundred twenty patients underwent MDCT of the trunk (60 thoracic, 60 abdominal) with an attenuation-based online tube current modulation. Consecutive acquisitions at standard and two lower effective mAs presets were obtained in each patient. Mean percentage effective mAs reductions were compared for each effective mAs preset, taking into account sex and body mass index. RESULTS. Mean effective mAs reduction was 16.9% and 20.0% for the chest and the abdomen, respectively. Mean percentage effective mAs reductions were found to be significantly different for sex (chest, p = 0.003; abdomen, p = 0.002) but not significantly different for the different effective mAs presets or body mass index. CONCLUSION. Attenuation-based online tube current modulation used with MDCT should be considered as a secondary tool of radiation dose reduction because it saves as much as 20% of the radiation dose on the adult trunk, regardless of initial mAs preset. However, initial decreases of mAs presets by the physician should be considered the primary tool for radiation dose reduction.
- 1 August 2003
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 181 (2) , 331-334
Dose Reduction in Multidetector CT Using Attenuation-Based Online Tube Current Modulation
OBJECTIVE. This study was designed to quantify the radiation dose saved by attenuation-based online tube current modulation applied to multidetector CT (MDCT) of the adult trunk as a function of effective milliampere-second (mAs) presets, sex, and body habitus. SUBJECTS AND METHODS. One hundred twenty patients underwent MDCT of the trunk (60 thoracic, 60 abdominal) with an attenuation-based online tube current modulation. Consecutive acquisitions at standard and two lower effective mAs presets were obtained in each patient. Mean percentage effective mAs reductions were compared for each effective mAs preset, taking into account sex and body mass index. RESULTS. Mean effective mAs reduction was 16.9% and 20.0% for the chest and the abdomen, respectively. Mean percentage effective mAs reductions were found to be significantly different for sex (chest, p = 0.003; abdomen, p = 0.002) but not significantly different for the different effective mAs presets or body mass index. CONCLUSION. Attenuation-based online tube current modulation used with MDCT should be considered as a secondary tool of radiation dose reduction because it saves as much as 20% of the radiation dose on the adult trunk, regardless of initial mAs preset. However, initial decreases of mAs presets by the physician should be considered the primary tool for radiation dose reduction.