Zhangyuan Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zhangyuan Wang has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Xudong Zhao
Centre for Sustainable Energy Technologies, University of Hull, HU6 7RX, UK
10 shared publications - Wansheng Yang
School of Civil and Transportation Engineering, Guangdong University of Technology, Guangzhou 510006, China
5 shared publications Fucheng Chen
School of Civil and Transportation Engineering, Guangdong University of Technology, 100 Waihuan Xi Road, Higher Education Mega Centre, Guangzhou 510006, Guangdong Province, P.R. China
3 shared publicationsJinwei Xiang
School of Civil and Transportation Engineering, Guangdong University of Technology, Guangdong, P.R. China
2 shared publicationsLiang Luo
School of Civil and Transportation Engineering, Guangdong University of Technology, Guangzhou P.R. China
2 shared publicationsSamson Shittu
Centre for Sustainable Energy Technologies, University of Hull, Hull, UK
2 shared publications
Latest Publications
- 29 March 2023
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 21 (2) , 399-412
Numerical and experimental investigation of a novel liquid upper-feeding micro-channel flat loop thermosyphon cooling and heat recovery system
A novel liquid upper-feeding micro-channel flat loop thermosyphon (LUF-MCFLTS) system was developed, to eliminate the drying phenomenon of the upper surface in the traditional LTS and provide a highly efficient solution for DC cooling and heat recovery. The effects of cooling capacity (cooling water flow rate and temperature), heat load, and filling ratio on the heat transfer performance of the LUF-MCFLTS system are investigated experimentally. The results indicated that with the increase in cooling water flow, the decrease in cooling water temperature, and the increase in heat load, the heat transfer performance of the LUF-MCFLTS system was better. Under a heat load of 500 W, a cooling water flow rate of 600 L/h, and a cooling water temperature of 15°C, the heat recovery efficiency could reach 86.28%. Compared with the MCFTS and MCFLTS systems in literature, the recovery efficiency of the LUF-MCFLTS system could be increased by 31.6% and 2.64%, respectively. In addition, an effective numerical model to predict the heat recovery efficiency of the LUF-MCFLTS system with the experimental data in the 2.07% error band has been established. This work provides a new idea and theoretical basis for the design of DC cooling and heat recovery system.
- 29 March 2023
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 21 (2) , 399-412
Numerical and experimental investigation of a novel liquid upper-feeding micro-channel flat loop thermosyphon cooling and heat recovery system
A novel liquid upper-feeding micro-channel flat loop thermosyphon (LUF-MCFLTS) system was developed, to eliminate the drying phenomenon of the upper surface in the traditional LTS and provide a highly efficient solution for DC cooling and heat recovery. The effects of cooling capacity (cooling water flow rate and temperature), heat load, and filling ratio on the heat transfer performance of the LUF-MCFLTS system are investigated experimentally. The results indicated that with the increase in cooling water flow, the decrease in cooling water temperature, and the increase in heat load, the heat transfer performance of the LUF-MCFLTS system was better. Under a heat load of 500 W, a cooling water flow rate of 600 L/h, and a cooling water temperature of 15°C, the heat recovery efficiency could reach 86.28%. Compared with the MCFTS and MCFLTS systems in literature, the recovery efficiency of the LUF-MCFLTS system could be increased by 31.6% and 2.64%, respectively. In addition, an effective numerical model to predict the heat recovery efficiency of the LUF-MCFLTS system with the experimental data in the 2.07% error band has been established. This work provides a new idea and theoretical basis for the design of DC cooling and heat recovery system.
- 31 October 2021
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 19 (12) , 1318-1332
Experimental investigation of a novel micro-channel flat loop heat pipe (MC-FLHP) for data center cooling and heat recovery
In this paper, a novel micro-channel flat loop heat pipe (MC-FLHP) for data center cooling and heat recovery is proposed, which has the following novelties and distinguished advantages, i.e., a tightly attached flat heat pipes array with IT server thus reaching a ‘server level’ cooling for data center, several pre-set micro-grooves which increases the convective heat transfer coefficient, and a separated evaporator-condenser which greatly improves the flexibility of the system’s installation. The proposed system with R134a (filling ratio of 30%) as the working fluid is designed, constructed and tested, and the testing results are used to evaluate its thermal recovery efficiency and its impact factors, i.e., simulated heat load, cooling water inlet temperature and height difference between the evaporator and condenser. Under the range of test conditions (e.g., simulated heat load from 500 W to 3000 W, cooling water inlet temperature from 15°C to 24°C, height difference from 0.6 m to 1.0 m), the overall thermal recovery efficiency is in the range 57.34% to 84.52%. It is found that under the specific operational conditions with the simulated heat load of 500 W, cooling water inlet temperature of 15°C, and height difference between the evaporator and the condenser of 0.8 m, a peak thermal recovery efficiency of 84.52% is achieved. This study can help achieve the global goals of green and sustainable data center, and also save data center energy consumption and thus operational costs.
- 31 October 2021
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 19 (12) , 1318-1332
Experimental investigation of a novel micro-channel flat loop heat pipe (MC-FLHP) for data center cooling and heat recovery
In this paper, a novel micro-channel flat loop heat pipe (MC-FLHP) for data center cooling and heat recovery is proposed, which has the following novelties and distinguished advantages, i.e., a tightly attached flat heat pipes array with IT server thus reaching a ‘server level’ cooling for data center, several pre-set micro-grooves which increases the convective heat transfer coefficient, and a separated evaporator-condenser which greatly improves the flexibility of the system’s installation. The proposed system with R134a (filling ratio of 30%) as the working fluid is designed, constructed and tested, and the testing results are used to evaluate its thermal recovery efficiency and its impact factors, i.e., simulated heat load, cooling water inlet temperature and height difference between the evaporator and condenser. Under the range of test conditions (e.g., simulated heat load from 500 W to 3000 W, cooling water inlet temperature from 15°C to 24°C, height difference from 0.6 m to 1.0 m), the overall thermal recovery efficiency is in the range 57.34% to 84.52%. It is found that under the specific operational conditions with the simulated heat load of 500 W, cooling water inlet temperature of 15°C, and height difference between the evaporator and the condenser of 0.8 m, a peak thermal recovery efficiency of 84.52% is achieved. This study can help achieve the global goals of green and sustainable data center, and also save data center energy consumption and thus operational costs.
- Open Access
- 18 June 2020
- Published by Oxford University Press (OUP) in International Journal of Low-Carbon Technologies
- Vol. 16 (1) , 98-113
Performance investigation of a micro-channel flat separated loop heat pipe system for data centre cooling
- 18 June 2020
- Published by Oxford University Press (OUP) in International Journal of Low-Carbon Technologies
- Vol. 16 (1) , 98-113
Open AccessPerformance investigation of a micro-channel flat separated loop heat pipe system for data centre cooling
- Open Access
Investigation on the Solar Absorption Property of the Nanoporous Alumina Sheet for Solar Application
In order to improve the absorption performance of the aluminum sheet for solar application, the nanoporous alumina sheets with the pore diameters of 30 nm and 400 nm were prepared by the anodic oxidation method. The absorption properties of the nanoporous alumina sheets under different solar radiation intensity were studied and compared with the conventional polished aluminum sheet. The results showed that the average absorptivity of the aluminum sheets decreased with the increase of the radiation intensity. When the radiation intensity was 100 W/m2, the nanoporous alumina sheet with the 30 nm pore diameter had the highest average solar absorptivity of 0.39, which was 18% higher than that of the nanoporous alumina sheet with 400 nm pore diameter, and 50% higher than that of the polished aluminum sheet. The maximum instantaneous absorption efficiency of the nanoporous alumina sheet with 30 nm pore diameter was found at 0.92 when the radiation intensity was 100 W/m2. The testing results indicated that the nanoporous alumina sheet with the 30 nm pore diameter performed the best compared with the other two aluminum sheets. By error propagation analysis, the relative error of the average amount of heat absorption and the average absorptivity were acceptable.
Open AccessInvestigation on the Solar Absorption Property of the Nanoporous Alumina Sheet for Solar Application
In order to improve the absorption performance of the aluminum sheet for solar application, the nanoporous alumina sheets with the pore diameters of 30 nm and 400 nm were prepared by the anodic oxidation method. The absorption properties of the nanoporous alumina sheets under different solar radiation intensity were studied and compared with the conventional polished aluminum sheet. The results showed that the average absorptivity of the aluminum sheets decreased with the increase of the radiation intensity. When the radiation intensity was 100 W/m2, the nanoporous alumina sheet with the 30 nm pore diameter had the highest average solar absorptivity of 0.39, which was 18% higher than that of the nanoporous alumina sheet with 400 nm pore diameter, and 50% higher than that of the polished aluminum sheet. The maximum instantaneous absorption efficiency of the nanoporous alumina sheet with 30 nm pore diameter was found at 0.92 when the radiation intensity was 100 W/m2. The testing results indicated that the nanoporous alumina sheet with the 30 nm pore diameter performed the best compared with the other two aluminum sheets. By error propagation analysis, the relative error of the average amount of heat absorption and the average absorptivity were acceptable.
- 9 July 2019
- Published by Springer Nature
- p. 79-100
Heat Pipe and Loop Heat Pipe Technologies and Their Applications in Solar Systems
- 9 July 2019
- Published by Springer Nature
- p. 79-100
Heat Pipe and Loop Heat Pipe Technologies and Their Applications in Solar Systems
- Open Access
- 24 April 2019
- Published by IntechOpen
Study of a Novel Liquid-Vapour Separator-Incorporated Gravitational Loop Heat Pipe
The aim of this chapter is to report the study of a novel liquid-vapour separator-incorporated gravity-assisted loop heat pipe (GALHP). This involves a dedicated conceptual formation, thermo-fluid analyses, and computer modelling and experimental validation. The innovative feature of the new GALHP is the integration of a dedicated liquid vapour separator on top of the evaporator section, eliminating the potential entrainment between the heat pipe liquid and the steam stream, while addressing the inherent ‘dry-out’ problem exhibited in the traditional GALHP. Based on this recognised novelty, a dedicated steady-state thermal model covering the mass continuity, energy conservation and Darcy equations were established. Under the specifically defined operational condition, the proposed GALHP has more evenly distributed axial temperature profile. The effective thermal conductivity in the proposed GALHP was 29,968 W/C m. It is therefore concluded that the novel heat pipe could achieve a significantly enhanced heat transport effect. The results derived from this research enabled characterisation of the thermal performance of the proposed GALHP and validation of the developed computer simulation model. The research will enable design, optimisation and analysis of such a new GALHP, thus promoting its wide application and achieving efficient thermal management.
- 24 April 2019
- Published by IntechOpen
Open AccessStudy of a Novel Liquid-Vapour Separator-Incorporated Gravitational Loop Heat Pipe
The aim of this chapter is to report the study of a novel liquid-vapour separator-incorporated gravity-assisted loop heat pipe (GALHP). This involves a dedicated conceptual formation, thermo-fluid analyses, and computer modelling and experimental validation. The innovative feature of the new GALHP is the integration of a dedicated liquid vapour separator on top of the evaporator section, eliminating the potential entrainment between the heat pipe liquid and the steam stream, while addressing the inherent ‘dry-out’ problem exhibited in the traditional GALHP. Based on this recognised novelty, a dedicated steady-state thermal model covering the mass continuity, energy conservation and Darcy equations were established. Under the specifically defined operational condition, the proposed GALHP has more evenly distributed axial temperature profile. The effective thermal conductivity in the proposed GALHP was 29,968 W/C m. It is therefore concluded that the novel heat pipe could achieve a significantly enhanced heat transport effect. The results derived from this research enabled characterisation of the thermal performance of the proposed GALHP and validation of the developed computer simulation model. The research will enable design, optimisation and analysis of such a new GALHP, thus promoting its wide application and achieving efficient thermal management.
- Open Access
Study on Dehumidification Performance of a Multi-Stage Internal Cooling Solid Desiccant Adsorption Packed Bed
In this paper, the solid desiccant adsorption packed bed with a three-stage internal cooling (ICSPB) has been proposed to improve the dehumidification efficiency and make a comparison with that of non-internal cooling. To investigate the performance of the ICSPB, the dehumidification capacity, dehumidification efficiency, water content of solid desiccant, moisture ratio of solid desiccant, temperature of solid desiccant and inlet and outlet air temperature difference were discussed in different conditions of inlet air and supplying water temperature. It was found that the dehumidification performance of the bed with internal cooling could be improved greatly in the low temperature and low humidity conditions, while in the high temperature and humid, the improvement was not obvious. With internal cooling, the dehumidification efficiency and the water content of the solid desiccant could be improved 59.69% and 110.7%, respectively, and the temperature of solid desiccant could be reduced 2.2 °C when the ICSPB operated at the inlet air temperature of 20 °C, inlet humidity of 55%, and water temperature of 14 °C. Moreover, the dehumidification performance at each stage of ICSPB was studied. It was found that, the first stage played the most important role in the dehumidification process. In addition, the calculation models that can be used to predict the moisture ratio and the temperature of solid desiccant were established on the test results.
Open AccessStudy on Dehumidification Performance of a Multi-Stage Internal Cooling Solid Desiccant Adsorption Packed Bed
In this paper, the solid desiccant adsorption packed bed with a three-stage internal cooling (ICSPB) has been proposed to improve the dehumidification efficiency and make a comparison with that of non-internal cooling. To investigate the performance of the ICSPB, the dehumidification capacity, dehumidification efficiency, water content of solid desiccant, moisture ratio of solid desiccant, temperature of solid desiccant and inlet and outlet air temperature difference were discussed in different conditions of inlet air and supplying water temperature. It was found that the dehumidification performance of the bed with internal cooling could be improved greatly in the low temperature and low humidity conditions, while in the high temperature and humid, the improvement was not obvious. With internal cooling, the dehumidification efficiency and the water content of the solid desiccant could be improved 59.69% and 110.7%, respectively, and the temperature of solid desiccant could be reduced 2.2 °C when the ICSPB operated at the inlet air temperature of 20 °C, inlet humidity of 55%, and water temperature of 14 °C. Moreover, the dehumidification performance at each stage of ICSPB was studied. It was found that, the first stage played the most important role in the dehumidification process. In addition, the calculation models that can be used to predict the moisture ratio and the temperature of solid desiccant were established on the test results.
- Open Access
- 17 January 2018
- Published by SAGE Publications in Building Services Engineering Research & Technology
- Vol. 39 (5) , 540-556
Experimental investigation of the novel BIPV/T system employing micro-channel flat-plate heat pipes
In this paper, the micro-channel flat-plate heat pipes-based BIPV/T system has been proposed, which is expected to have the characteristics, e.g. reduced contact thermal resistance, enhanced heat transfer area, improved heat transfer efficiency and building integration. The proposed system was constructed at the laboratory of Guangdong University of Technology (China) to study its performance. The temperatures of the glass cover, PV panel, micro-channel flat-plate heat pipes, and tank water were measured, as well as the ambient temperature. The thermal and electrical efficiency was also calculated for the system operated under the conditions with different simulated radiations and water flow rates. It was found that the proposed system can achieve the maximum average overall efficiency of 50.4% (thermal efficiency of 45.9% and electrical efficiency of 4.5%) for the simulated radiation of 300 W/m 2 and water flow rate of 600 L/h. By comparing the proposed system with the two previous systems employing the conventional heat pipes, the thermal efficiency of the proposed system was clearly improved. The research will develop an innovative BIPV/T technology possessing high thermal conduction capability and high thermal efficiency compared with the conventional BIPV/T system, and helps realise the global targets of reducing carbon emission and saving primary energy in buildings. Practical application: This novel BIPV/T employing micro-channel flat-plate heat pipes will be potentially used in buildings to provide amount of electricity and thermal energy. The generated electricity will be used by the residents for electrical devices, and the thermal energy can be used for hot water, even for space heating and cooling.
- 17 January 2018
- Published by SAGE Publications in Building Services Engineering Research & Technology
- Vol. 39 (5) , 540-556
Open AccessExperimental investigation of the novel BIPV/T system employing micro-channel flat-plate heat pipes
In this paper, the micro-channel flat-plate heat pipes-based BIPV/T system has been proposed, which is expected to have the characteristics, e.g. reduced contact thermal resistance, enhanced heat transfer area, improved heat transfer efficiency and building integration. The proposed system was constructed at the laboratory of Guangdong University of Technology (China) to study its performance. The temperatures of the glass cover, PV panel, micro-channel flat-plate heat pipes, and tank water were measured, as well as the ambient temperature. The thermal and electrical efficiency was also calculated for the system operated under the conditions with different simulated radiations and water flow rates. It was found that the proposed system can achieve the maximum average overall efficiency of 50.4% (thermal efficiency of 45.9% and electrical efficiency of 4.5%) for the simulated radiation of 300 W/m 2 and water flow rate of 600 L/h. By comparing the proposed system with the two previous systems employing the conventional heat pipes, the thermal efficiency of the proposed system was clearly improved. The research will develop an innovative BIPV/T technology possessing high thermal conduction capability and high thermal efficiency compared with the conventional BIPV/T system, and helps realise the global targets of reducing carbon emission and saving primary energy in buildings. Practical application: This novel BIPV/T employing micro-channel flat-plate heat pipes will be potentially used in buildings to provide amount of electricity and thermal energy. The generated electricity will be used by the residents for electrical devices, and the thermal energy can be used for hot water, even for space heating and cooling.
- Open Access
Performance Investigation of the Novel Solar-Powered Dehumidification Window for Residential Buildings
In this paper, a solar-powered dehumidification window (SPDW), combining a conventional double-glazed building window with a solid desiccant packed bed and a photovoltaic panel, has been proposed to dehumidify the air supplied to a residential building in an energy-saving way. The solid desiccant packed bed was installed between the double layers of the residential window to achieve the compact building-integrated window-dehumidifying system that could be regenerated by solar energy, and the photovoltaic panel was used to compensate the electricity for the operation of the fans to supply the air to the building. To investigate the dehumidification and regeneration performance of the SPDW, the transient moisture removal, dehumidification efficiency, temperature difference between the building inlet and outlet air, heat transfer characteristics, desiccant temperature, regeneration rate, and the power of the fans and the photovoltaic panel were analysed for different inlet air conditions and simulated solar radiation. It was found that, for the system operated under an inlet air temperature of 19.2 °C and a relative humidity of 86.1% during the dehumidification process, the system performed with a maximum transient moisture removal of 7.1 g/kg, a maximum dehumidification efficiency of 58.60%, a maximum temperature difference between the inlet and outlet air of 10.7 °C, and a maximum released adsorption heat absorbed by the dehumidified air of 89.66%. In the regeneration process, the system performed with a maximum desiccant temperature of 35.3 °C, a maximum regeneration rate of 153 g/h, and a maximum power of the photovoltaic panels of 39.83 W under the simulated solar radiation of 900 W/m2. The results from the established semi-empirical model agreed well with the testing results, and the model could be used to predict the water content ratio of the desiccant modules during the dehumidification process under different conditions, which will be helpful in the analysis and application of the SPDW in the future.
Open AccessPerformance Investigation of the Novel Solar-Powered Dehumidification Window for Residential Buildings
In this paper, a solar-powered dehumidification window (SPDW), combining a conventional double-glazed building window with a solid desiccant packed bed and a photovoltaic panel, has been proposed to dehumidify the air supplied to a residential building in an energy-saving way. The solid desiccant packed bed was installed between the double layers of the residential window to achieve the compact building-integrated window-dehumidifying system that could be regenerated by solar energy, and the photovoltaic panel was used to compensate the electricity for the operation of the fans to supply the air to the building. To investigate the dehumidification and regeneration performance of the SPDW, the transient moisture removal, dehumidification efficiency, temperature difference between the building inlet and outlet air, heat transfer characteristics, desiccant temperature, regeneration rate, and the power of the fans and the photovoltaic panel were analysed for different inlet air conditions and simulated solar radiation. It was found that, for the system operated under an inlet air temperature of 19.2 °C and a relative humidity of 86.1% during the dehumidification process, the system performed with a maximum transient moisture removal of 7.1 g/kg, a maximum dehumidification efficiency of 58.60%, a maximum temperature difference between the inlet and outlet air of 10.7 °C, and a maximum released adsorption heat absorbed by the dehumidified air of 89.66%. In the regeneration process, the system performed with a maximum desiccant temperature of 35.3 °C, a maximum regeneration rate of 153 g/h, and a maximum power of the photovoltaic panels of 39.83 W under the simulated solar radiation of 900 W/m2. The results from the established semi-empirical model agreed well with the testing results, and the model could be used to predict the water content ratio of the desiccant modules during the dehumidification process under different conditions, which will be helpful in the analysis and application of the SPDW in the future.
- Open Access
Performance Study of a Novel Solar Solid Dehumidification/Regeneration Bed for Use in Buildings Air Conditioning Systems
In this paper, a novel solar solid dehumidification/regeneration bed has been proposed, and its three regeneration methods, i.e., simulated solar radiation regeneration, microwave regeneration, and combined regeneration of the microwave and simulated solar radiation, were experimentally investigated and compared, as well as the dehumidification performance. The degree of regeneration of the proposed system under the regeneration method combining both microwave irradiation and simulated solar radiation could reach 77.7%, which was 3.77 times higher than that of the system under the simulated solar regeneration method and 1.05 times higher than that of the system under the microwave regeneration. The maximum energy efficiency of the proposed system under the combined regeneration method was 21.7%, while it was only 19.4% for the system under microwave regeneration. All these proved that the combined regeneration method of the simulated solar and microwave radiation not only improved the regeneration efficiency of the system, but also enhanced the energy efficiency. For the dehumidification performance, the maximum transient moisture removal was 14.1 g/kg, the maximum dehumidification efficiency was 68.0% and the maximum speed of dehumidification was 0.294 g/(kg·s) when the inlet air temperature was at 26.09 °C and the air relative humidity was at 89.23%. By comparing the testing results with the semi-empirical results from the Page model, it was indicated that the Page model can predict the regeneration characteristics of the novel solar solid dehumidification/regeneration bed under the combined method of microwave and simulated solar regeneration. The results of this research should prove useful to researchers and engineers to exploit the potential of solar technologies in buildings worldwide.
Open AccessPerformance Study of a Novel Solar Solid Dehumidification/Regeneration Bed for Use in Buildings Air Conditioning Systems
In this paper, a novel solar solid dehumidification/regeneration bed has been proposed, and its three regeneration methods, i.e., simulated solar radiation regeneration, microwave regeneration, and combined regeneration of the microwave and simulated solar radiation, were experimentally investigated and compared, as well as the dehumidification performance. The degree of regeneration of the proposed system under the regeneration method combining both microwave irradiation and simulated solar radiation could reach 77.7%, which was 3.77 times higher than that of the system under the simulated solar regeneration method and 1.05 times higher than that of the system under the microwave regeneration. The maximum energy efficiency of the proposed system under the combined regeneration method was 21.7%, while it was only 19.4% for the system under microwave regeneration. All these proved that the combined regeneration method of the simulated solar and microwave radiation not only improved the regeneration efficiency of the system, but also enhanced the energy efficiency. For the dehumidification performance, the maximum transient moisture removal was 14.1 g/kg, the maximum dehumidification efficiency was 68.0% and the maximum speed of dehumidification was 0.294 g/(kg·s) when the inlet air temperature was at 26.09 °C and the air relative humidity was at 89.23%. By comparing the testing results with the semi-empirical results from the Page model, it was indicated that the Page model can predict the regeneration characteristics of the novel solar solid dehumidification/regeneration bed under the combined method of microwave and simulated solar regeneration. The results of this research should prove useful to researchers and engineers to exploit the potential of solar technologies in buildings worldwide.