J. -M. Buzelin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
J. -M. Buzelin has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
L Le Normand
8 shared publications- Pascal Glemain
Clinique Urologique, Hôtel-Dieu, Nantes, France
7 shared publications - Georges Karam
Clinique Urologique, CHU Hôtel-Dieu, Nantes, France
4 shared publications J P Cordonnier
4 shared publicationsB Guillonneau
2 shared publicationsJ Auvigne
2 shared publications
Latest Publications
- 1 January 2011
- Published by Springer Nature
- p. 31-40
La physiologie du bas appareil urinaire de l’homme
- 1 January 2011
- Published by Springer Nature
- p. 31-40
La physiologie du bas appareil urinaire de l’homme
- 1 February 2001
- Vol. 11 (1) , 127-31
[Accuracy of pressure measurements obtained with a new rectal balloon catheter].
The accuracy of measurements performed by a balloon catheter used to record abdominal pressure during urodynamic investigations was verified on a test bench. To study the accuracy and precision of the pressure measurements obtained with a new rectal balloon catheter (ref. 95018 Laboratoires Vermed), designed to record abdominal pressure during urodynamic assessments. The clinical value of this catheter, using air for pressure transmission, is its simplicity, as there is no contamination of the perfusion circuit or transducer, no purging of the circuit, and artefacts related to movements of the tubing are eliminated. The catheter was placed in a pressure chamber fitted with a precise, calibrated regulation system allowing programmed pressure variations from 10 to 150 cmH2O. Pressures recorded by the test catheter were compared to reference pressures applied to the chamber. The frequency of acquisition of pressure measurements was 100 Hertz and the resolution was 10 Hertz. This model was used to study the accuracy of pressure measurements and the response times of the catheter. Measurements were performed with a volume of 2 ml of air introduced into the catheter (volume recommended by the manufacturer), and the optimal volume was investigated by inflating the catheter until the best result was obtained. The evaluation was based on calculation of the mean difference observed between the two measurements and the scatter of the differences observed. When the catheter was filled with 2 ml of air, pressures measured by the catheter were overestimated an average of 1.1 cmH2O (standard deviation = 1), and 95% of the differences between the two measurements were within +/- 2.15 cmH2O. The optimal air volume was found to be 1.5 ml. With this air volume, no significant difference was observed between the two measurements. The mean observed difference was 0.2 cmH2O (SD = 1.2), which means that 95% of the differences were situated within the range of +/- 2.35 cmH2O. The pressure recording method with this new catheter is validated in terms of physical parameters.
- 1 February 2001
- Vol. 11 (1) , 127-31
[Accuracy of pressure measurements obtained with a new rectal balloon catheter].
The accuracy of measurements performed by a balloon catheter used to record abdominal pressure during urodynamic investigations was verified on a test bench. To study the accuracy and precision of the pressure measurements obtained with a new rectal balloon catheter (ref. 95018 Laboratoires Vermed), designed to record abdominal pressure during urodynamic assessments. The clinical value of this catheter, using air for pressure transmission, is its simplicity, as there is no contamination of the perfusion circuit or transducer, no purging of the circuit, and artefacts related to movements of the tubing are eliminated. The catheter was placed in a pressure chamber fitted with a precise, calibrated regulation system allowing programmed pressure variations from 10 to 150 cmH2O. Pressures recorded by the test catheter were compared to reference pressures applied to the chamber. The frequency of acquisition of pressure measurements was 100 Hertz and the resolution was 10 Hertz. This model was used to study the accuracy of pressure measurements and the response times of the catheter. Measurements were performed with a volume of 2 ml of air introduced into the catheter (volume recommended by the manufacturer), and the optimal volume was investigated by inflating the catheter until the best result was obtained. The evaluation was based on calculation of the mean difference observed between the two measurements and the scatter of the differences observed. When the catheter was filled with 2 ml of air, pressures measured by the catheter were overestimated an average of 1.1 cmH2O (standard deviation = 1), and 95% of the differences between the two measurements were within +/- 2.15 cmH2O. The optimal air volume was found to be 1.5 ml. With this air volume, no significant difference was observed between the two measurements. The mean observed difference was 0.2 cmH2O (SD = 1.2), which means that 95% of the differences were situated within the range of +/- 2.35 cmH2O. The pressure recording method with this new catheter is validated in terms of physical parameters.
- 1 December 1997
- Vol. 7 (6) , 948-52
[Outcome of nephrogenic metaplasia of the bladder in kidney transplant recipients].
To evaluate the risk of recurrence and malignant degeneration of vesical nephrogenic metaplasia in renal transplant recipients. Fourteen patients with known nephrogenic metaplasia were systematically followed. Vesical biopsies were performed with a resector, stained with eosin haemalun saffron, analysed and compared to initial results. Labelling by anti-EBV and anti-CMV monoclonal antibodies was performed in 5 cases of intense inflammatory reactions. All patients were males, with a median age of 39 years. Nephrogenic metaplasia had been diagnosed 7 to 80 months after renal transplantation (median = 37.8). Twelve patients were reviewed 5 to 116 months after the initial diagnosis (median = 52). Relapse was observed in 83% of cases, but without any malignant degeneration. Nephrogenic metaplasia is therefore a benign recurrent disease. The importance of the initial blood supply and fibrosis in the case of recurrence suggest a disorder of the blood supply, probably traumatic in origin. Only symptomatic patients are currently followed.
- 1 December 1997
- Vol. 7 (6) , 948-52
[Outcome of nephrogenic metaplasia of the bladder in kidney transplant recipients].
To evaluate the risk of recurrence and malignant degeneration of vesical nephrogenic metaplasia in renal transplant recipients. Fourteen patients with known nephrogenic metaplasia were systematically followed. Vesical biopsies were performed with a resector, stained with eosin haemalun saffron, analysed and compared to initial results. Labelling by anti-EBV and anti-CMV monoclonal antibodies was performed in 5 cases of intense inflammatory reactions. All patients were males, with a median age of 39 years. Nephrogenic metaplasia had been diagnosed 7 to 80 months after renal transplantation (median = 37.8). Twelve patients were reviewed 5 to 116 months after the initial diagnosis (median = 52). Relapse was observed in 83% of cases, but without any malignant degeneration. Nephrogenic metaplasia is therefore a benign recurrent disease. The importance of the initial blood supply and fibrosis in the case of recurrence suggest a disorder of the blood supply, probably traumatic in origin. Only symptomatic patients are currently followed.
- 1 December 1996
- Vol. 6 (6) , 891-900
[Instantaneous pressure/flow ratio for non-permanent flows. Impact on the assessment of urethral resistance].
To verify the validity of the hypothesis of the almost continuous flow necessary for evaluation of instantaneous urethral resistance R by the pressure/flow relation R = P/Q2. An experimental device allowed investigation of the pressure/flow relation for discontinuous flow in a flexible tube. The tube was submitted to various collapsing pressures and opened under the effect of flow. The flow was discontinuous because of the variations of the proximal pressure or oscillations in the hydraulic diameter of the tube. These experiments showed that the approximation of continuous flow is justified within the limits of precision of the measuring methods used in urodynamics. The formula R = Q2 is therefore theoretically correct and validated by the experimentation. There is no hydrodynamic obstacle to the application of this formula to the calculation of instantaneous urethral resistance.
- 1 December 1996
- Vol. 6 (6) , 891-900
[Instantaneous pressure/flow ratio for non-permanent flows. Impact on the assessment of urethral resistance].
To verify the validity of the hypothesis of the almost continuous flow necessary for evaluation of instantaneous urethral resistance R by the pressure/flow relation R = P/Q2. An experimental device allowed investigation of the pressure/flow relation for discontinuous flow in a flexible tube. The tube was submitted to various collapsing pressures and opened under the effect of flow. The flow was discontinuous because of the variations of the proximal pressure or oscillations in the hydraulic diameter of the tube. These experiments showed that the approximation of continuous flow is justified within the limits of precision of the measuring methods used in urodynamics. The formula R = Q2 is therefore theoretically correct and validated by the experimentation. There is no hydrodynamic obstacle to the application of this formula to the calculation of instantaneous urethral resistance.
- 1 December 1993
- Vol. 3 (6) , 995
[Incidence of the form and caliber of urethral resistance. Evaluation for a normal masculine urethra and in cases of obstruction due to prostatic hypertrophy].
Certain forms of benign prostatic hypertrophy are associated with a reduction of the calibre of the prostatic urethra of the median lobe, a defect of infundibulisation of the bladder neck and a dilated appearance of the bulbar urethra. The objective of this study was to verify whether hydrodynamic arguments could be used to confirm the concept that defective infundibulisation of the bladder neck is directly responsible for an obstructive syndrome or via a reduction in the calibre of the bladder neck orifice. More generally, this study was designed to quantify the distribution of resistance to flow along the normal urethra and to define the role of cervicoprostatic and urethral deformities in the obstruction associated with benign prostatic hypertrophy. Urodynamic studies are unable to answer this question, as the instantaneous urethral resistance is evaluated globally by the Pressure-Flow relation. The authors performed morphological analysis to divide the urethra into simple hydraulic segments for which the corresponding pressure drop coefficients were calculated. These coefficients constitute an approach to segmental resistance to flow and can be used to quantify changes in shape observed on voiding urethrography or ultrasonography. Digital analysis of voiding urethrographies showed that, under normal conditions, urethral resistance was regularly distributed along the urethra and essentially depended on friction of the urethral wall. In the case of benign prostatic hypertrophy, even with a median lobe, the increase in the pressure drop coefficients was due to a reduction in the calibre of the bladder neck orifice and prostatic urethra. Cervical deformities appeared to be minimally obstructive, according to urodynamic parameters, if they were not associated with a reduction in the calibre of the bladder neck orifice.
- 1 December 1993
- Vol. 3 (6) , 995
[Incidence of the form and caliber of urethral resistance. Evaluation for a normal masculine urethra and in cases of obstruction due to prostatic hypertrophy].
Certain forms of benign prostatic hypertrophy are associated with a reduction of the calibre of the prostatic urethra of the median lobe, a defect of infundibulisation of the bladder neck and a dilated appearance of the bulbar urethra. The objective of this study was to verify whether hydrodynamic arguments could be used to confirm the concept that defective infundibulisation of the bladder neck is directly responsible for an obstructive syndrome or via a reduction in the calibre of the bladder neck orifice. More generally, this study was designed to quantify the distribution of resistance to flow along the normal urethra and to define the role of cervicoprostatic and urethral deformities in the obstruction associated with benign prostatic hypertrophy. Urodynamic studies are unable to answer this question, as the instantaneous urethral resistance is evaluated globally by the Pressure-Flow relation. The authors performed morphological analysis to divide the urethra into simple hydraulic segments for which the corresponding pressure drop coefficients were calculated. These coefficients constitute an approach to segmental resistance to flow and can be used to quantify changes in shape observed on voiding urethrography or ultrasonography. Digital analysis of voiding urethrographies showed that, under normal conditions, urethral resistance was regularly distributed along the urethra and essentially depended on friction of the urethral wall. In the case of benign prostatic hypertrophy, even with a median lobe, the increase in the pressure drop coefficients was due to a reduction in the calibre of the bladder neck orifice and prostatic urethra. Cervical deformities appeared to be minimally obstructive, according to urodynamic parameters, if they were not associated with a reduction in the calibre of the bladder neck orifice.
- 1 August 1993
- Vol. 3 (4) , 644-57
[Instantaneous pressure-flow relations in a continuous flow in a collapsible tube: impact on the evaluation of urethral resistance].
The urethra is a collapsed tube in the absence of micturition. Consequently, the evaluation of instantaneous urethral resistance by the pressure/flow relation (R = P/Q2) derived from Bernoulli's equation has been criticised for not taking into account the opening pressure or at least the fact that flow must maintain patency of the urethra during voiding. The objective of this study was to determine whether such a criticism is justified in terms of fluid mechanics. A study of the pressure/flow relation was performed in a soft tube, collapsed by various peritubular pressures, which subsequently opened in response to flow. Experiments demonstrated that the pressure/flow relation, the instantaneous resistance to flow and the pressure drop were identical when the tube reached the same calibre, despite different peritubular pressures. The same pressure therefore propels the flow and maintains the patency of the tube. Consequently, it would be unreasonable to expect to improve the evaluation of instantaneous urethral resistance by subtracting an opening pressure from the maximal bladder pressure. The formula R = P/Q2 is valid, experimentally, and complies with the principles of fluid mechanics. In theory and in practice, it constitutes a good method of evaluation of instantaneous resistance.
- 1 August 1993
- Vol. 3 (4) , 644-57
[Instantaneous pressure-flow relations in a continuous flow in a collapsible tube: impact on the evaluation of urethral resistance].
The urethra is a collapsed tube in the absence of micturition. Consequently, the evaluation of instantaneous urethral resistance by the pressure/flow relation (R = P/Q2) derived from Bernoulli's equation has been criticised for not taking into account the opening pressure or at least the fact that flow must maintain patency of the urethra during voiding. The objective of this study was to determine whether such a criticism is justified in terms of fluid mechanics. A study of the pressure/flow relation was performed in a soft tube, collapsed by various peritubular pressures, which subsequently opened in response to flow. Experiments demonstrated that the pressure/flow relation, the instantaneous resistance to flow and the pressure drop were identical when the tube reached the same calibre, despite different peritubular pressures. The same pressure therefore propels the flow and maintains the patency of the tube. Consequently, it would be unreasonable to expect to improve the evaluation of instantaneous urethral resistance by subtracting an opening pressure from the maximal bladder pressure. The formula R = P/Q2 is valid, experimentally, and complies with the principles of fluid mechanics. In theory and in practice, it constitutes a good method of evaluation of instantaneous resistance.
- 1 June 1992
- Vol. 2 (3) , 363-71
[Multifactorial urodynamic study of 115 patients with dysuria and benign prostatic hypertrophy].
Discriminant analyses based on preoperative urodynamic parameters have proved inaccurate in predicting functional results after prostatectomy. To investigate the cause of this failure, we studied a group of 115 patients consecutively referred for prostatism and selected for prostatic surgery only on clinical criteria and flow rate. A preoperative urodynamic work-up was performed, including cystometry and urethrometry. The patients were reexamined 2 months postoperatively and underwent control uroflowmetry. All preoperative urodynamic data were computed simultaneously using principal component analysis and canonical discriminant analysis. The significance of the diagrams obtained with these multifactorial analyses was more closely examined than in previous studies. The results of classification by the discriminant function demonstrating the best combination of preoperative urodynamic variables resulted in 44% of patients being correctly rated. Examination of the diagrams showed that the major cause of failure in previous studies was the great variety of urodynamic conditions in men with prostatism, which indicates a need for multifactorial interpretation of the results of urodynamic explorations.
- 1 June 1992
- Vol. 2 (3) , 363-71
[Multifactorial urodynamic study of 115 patients with dysuria and benign prostatic hypertrophy].
Discriminant analyses based on preoperative urodynamic parameters have proved inaccurate in predicting functional results after prostatectomy. To investigate the cause of this failure, we studied a group of 115 patients consecutively referred for prostatism and selected for prostatic surgery only on clinical criteria and flow rate. A preoperative urodynamic work-up was performed, including cystometry and urethrometry. The patients were reexamined 2 months postoperatively and underwent control uroflowmetry. All preoperative urodynamic data were computed simultaneously using principal component analysis and canonical discriminant analysis. The significance of the diagrams obtained with these multifactorial analyses was more closely examined than in previous studies. The results of classification by the discriminant function demonstrating the best combination of preoperative urodynamic variables resulted in 44% of patients being correctly rated. Examination of the diagrams showed that the major cause of failure in previous studies was the great variety of urodynamic conditions in men with prostatism, which indicates a need for multifactorial interpretation of the results of urodynamic explorations.
- 1 August 1991
- Vol. 1 (4) , 611-736
[Physiology and functional exploration of the upper urinary tract].
- 1 August 1991
- Vol. 1 (4) , 611-736
[Physiology and functional exploration of the upper urinary tract].
- 1 February 1991
- Vol. 1 (1) , 44-5, 48
[Bibliography of a year in urodynamics and neuro-urology].
- 1 January 1990
- Vol. 24 (2) , 157-60
[Post-traumatic stenosis of the membranous urethra].
Secondary urethral stricture is the most serious complication of traumatic rupture of the membranous urethra, directly related to the treatment of the rupture. In a series of 45 patients treated for urethral rupture with a minimal follow-up of 5 years, 30 developed stricture (66%). An urethral guide, inserted in 31 cases, was responsible for the stricture in 26 of these cases (84%). This stricture developed rapidly (average of 7.4 months), whether the initial rupture was complete or incomplete and was longer (average of 35 mm) in the case of complete rupture. End-to-end urethrorraphy performed between the 15th and 35th day in 14 patients was complicated by 4 secondary strictures (28%). The treatment of the stricture depended on the initial treatment of the rupture and the radiological length of the stricture. In the case of stricture secondary to an urethral guide, end-to-end urethrorraphy for a stricture less than or equal to 40 mm (12 cases) and 2 stage urethroplasty for a stricture greater than 40 mm (4 cases) achieved a good result in 68.8% of cases. The strictures secondary to end-to-end urethrorraphy (4 cases) were treated by direct vision urethrotomy (3 cases) with 100% of immediate good results and by urethral telescoping (1 case) complicated stress urinary incontinence.
- 1 January 1990
- Vol. 24 (2) , 157-60
[Post-traumatic stenosis of the membranous urethra].
Secondary urethral stricture is the most serious complication of traumatic rupture of the membranous urethra, directly related to the treatment of the rupture. In a series of 45 patients treated for urethral rupture with a minimal follow-up of 5 years, 30 developed stricture (66%). An urethral guide, inserted in 31 cases, was responsible for the stricture in 26 of these cases (84%). This stricture developed rapidly (average of 7.4 months), whether the initial rupture was complete or incomplete and was longer (average of 35 mm) in the case of complete rupture. End-to-end urethrorraphy performed between the 15th and 35th day in 14 patients was complicated by 4 secondary strictures (28%). The treatment of the stricture depended on the initial treatment of the rupture and the radiological length of the stricture. In the case of stricture secondary to an urethral guide, end-to-end urethrorraphy for a stricture less than or equal to 40 mm (12 cases) and 2 stage urethroplasty for a stricture greater than 40 mm (4 cases) achieved a good result in 68.8% of cases. The strictures secondary to end-to-end urethrorraphy (4 cases) were treated by direct vision urethrotomy (3 cases) with 100% of immediate good results and by urethral telescoping (1 case) complicated stress urinary incontinence.