Xingping Kang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Xingping Kang has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Daniel S. Berman
Cedars-Sinai Medical Center, Los Angeles, CA (D.S.B.).
5 shared publications - John D. Friedman5 shared publications
- Sean W. Hayes
Department of Imaging, Division of Nuclear Medicine, Cedars-Sinai Medical Center, Los Angeles, California 90048, USA
5 shared publications - Guido Germano
Cedars-Sinai Medical Ctr. (United States)
4 shared publications Hidetaka Nishina
3 shared publicationsRory Hachamovitch
3 shared publications
Latest Publications
- 1 July 2006
- Vol. 47 (7) , 1107-18
Roles of nuclear cardiology, cardiac computed tomography, and cardiac magnetic resonance: Noninvasive risk stratification and a conceptual framework for the selection of noninvasive imaging tests in patients with known or suspected coronary artery disease.
This review deals with noninvasive imaging for risk stratification and with a conceptual approach to the selection of noninvasive tests in patients with suspected or known chronic coronary artery disease (CAD). Already widely acknowledged with SPECT, there is an increasing body of literature data demonstrating that CT coronary calcium assessment is also of prognostic value. The amount of coronary atherosclerosis, as can be extrapolated from CT coronary calcium score, has been shown to be highly predictive of cardiac events. The principal difference between myocardial perfusion SPECT (MPS) and CT coronary calcium for prognostic application appears to be that the former is an excellent tool for assessing short-term risk, thus effectively guiding decisions regarding revascularization. In contrast, the atherosclerosis imaging methods are likely to provide greater long-term risk assessment and, thus, are more useful in determination of the need for aggressive medical prevention measures. Although the more recent development of CT coronary angiography is promising for diagnosis, there has been no information to date regarding the prognostic value of the CT angiographic data. Similarly, cardiac MRI has not yet been adequately studied for its prognostic content. The selection of the most appropriate test for a given patient depends on the specific question being asked. In patients with a very low likelihood of CAD, no imaging test may be required. In screening the remaining asymptomatic patients, atherosclerosis imaging may be beneficial. In symptomatic patients, MPS, CT coronary angiography, and cardiac MRI play important roles. We consider it likely that, with an increased emphasis on prevention and a concomitant aging of the population, many forms of noninvasive cardiac imaging will continue to grow, with nuclear cardiology continuing to grow.
- 1 July 2006
- Vol. 47 (7) , 1107-18
Roles of nuclear cardiology, cardiac computed tomography, and cardiac magnetic resonance: Noninvasive risk stratification and a conceptual framework for the selection of noninvasive imaging tests in patients with known or suspected coronary artery disease.
This review deals with noninvasive imaging for risk stratification and with a conceptual approach to the selection of noninvasive tests in patients with suspected or known chronic coronary artery disease (CAD). Already widely acknowledged with SPECT, there is an increasing body of literature data demonstrating that CT coronary calcium assessment is also of prognostic value. The amount of coronary atherosclerosis, as can be extrapolated from CT coronary calcium score, has been shown to be highly predictive of cardiac events. The principal difference between myocardial perfusion SPECT (MPS) and CT coronary calcium for prognostic application appears to be that the former is an excellent tool for assessing short-term risk, thus effectively guiding decisions regarding revascularization. In contrast, the atherosclerosis imaging methods are likely to provide greater long-term risk assessment and, thus, are more useful in determination of the need for aggressive medical prevention measures. Although the more recent development of CT coronary angiography is promising for diagnosis, there has been no information to date regarding the prognostic value of the CT angiographic data. Similarly, cardiac MRI has not yet been adequately studied for its prognostic content. The selection of the most appropriate test for a given patient depends on the specific question being asked. In patients with a very low likelihood of CAD, no imaging test may be required. In screening the remaining asymptomatic patients, atherosclerosis imaging may be beneficial. In symptomatic patients, MPS, CT coronary angiography, and cardiac MRI play important roles. We consider it likely that, with an increased emphasis on prevention and a concomitant aging of the population, many forms of noninvasive cardiac imaging will continue to grow, with nuclear cardiology continuing to grow.
- 1 December 2004
- Vol. 45 (12) , 1999-2007
Integration of automatically measured transient ischemic dilation ratio into interpretation of adenosine stress myocardial perfusion SPECT for detection of severe and extensive CAD.
The aim of our study was to derive and to validate the normal threshold for an automatically measured left ventricular transient ischemic dilation (TID) ratio in patients referred for adenosine stress myocardial perfusion SPECT (MPS) and to assess the value of integrating TID in detecting severe and extensive coronary artery disease (CAD). Normal limits for the TID ratio were derived using dual-isotope MPS data from 38 patients with a low ( or =90% stenosis) in the proximal left anterior descending artery or in 2 or more coronary arteries, 64 (36%) had no significant CAD ( 1.36). Abnormal TID ratio using this threshold demonstrated high sensitivity and specificity for severe and extensive CAD (71% and 86%, respectively), and similar sensitivity and specificity were observed in the prospective validation group (73% and 88%, respectively). In the combined pilot and validation groups, the absence of both abnormal TID ratio and abnormal perfusion was highly specific for the absence of severe and extensive CAD; only one (1.3%) of 79 patients with severe and extensive CAD had neither of these abnormal findings on adenosine MPS. In patients with both abnormal TID ratio and abnormal perfusion, 55 of 84 (65%) had severe and extensive CAD. When patients had one but not both of these findings, 26 of 193 (13%) had severe and extensive CAD. The automatically measured TID ratio is a useful clinical marker that is sensitive and highly specific for identification of severe and extensive CAD in patients undergoing adenosine MPS. Integration of abnormal TID ratio into the dual-isotope MPS image interpretation algorithm improves the identification of severe and extensive CAD in adenosine MPS.
- 1 December 2004
- Vol. 45 (12) , 1999-2007
Integration of automatically measured transient ischemic dilation ratio into interpretation of adenosine stress myocardial perfusion SPECT for detection of severe and extensive CAD.
The aim of our study was to derive and to validate the normal threshold for an automatically measured left ventricular transient ischemic dilation (TID) ratio in patients referred for adenosine stress myocardial perfusion SPECT (MPS) and to assess the value of integrating TID in detecting severe and extensive coronary artery disease (CAD). Normal limits for the TID ratio were derived using dual-isotope MPS data from 38 patients with a low ( or =90% stenosis) in the proximal left anterior descending artery or in 2 or more coronary arteries, 64 (36%) had no significant CAD ( 1.36). Abnormal TID ratio using this threshold demonstrated high sensitivity and specificity for severe and extensive CAD (71% and 86%, respectively), and similar sensitivity and specificity were observed in the prospective validation group (73% and 88%, respectively). In the combined pilot and validation groups, the absence of both abnormal TID ratio and abnormal perfusion was highly specific for the absence of severe and extensive CAD; only one (1.3%) of 79 patients with severe and extensive CAD had neither of these abnormal findings on adenosine MPS. In patients with both abnormal TID ratio and abnormal perfusion, 55 of 84 (65%) had severe and extensive CAD. When patients had one but not both of these findings, 26 of 193 (13%) had severe and extensive CAD. The automatically measured TID ratio is a useful clinical marker that is sensitive and highly specific for identification of severe and extensive CAD in patients undergoing adenosine MPS. Integration of abnormal TID ratio into the dual-isotope MPS image interpretation algorithm improves the identification of severe and extensive CAD in adenosine MPS.
- 1 July 2004
- Vol. 45 (7) , 1128-34
"Motion-frozen" display and quantification of myocardial perfusion.
Gated myocadial perfusion SPECT (MPS) incorporates functional and perfusion information of the left ventricle (LV). To improve the image quality and accuracy of gated MPS we propose to eliminate the influence of cardiac LV motion in the display and quantification by a novel "motion-frozen" (MF) technique. Three-dimensional LV contours were identified on images of the individual time phases. Three-dimensional phase-to-phase motion vectors were derived by sampling of the epi- and endocardial surfaces. A nonlinear image warping (thin-plate spline) was applied to warp all image phases to fit the end-diastolic (ED) phase. Warped images were created to provide the LV image in the ED phase but containing counts from an arbitrary number of time intervals. MF quantification has been performed using the same phase-to-phase motion vectors. MF normal perfusion limits were created from (99m)Tc sestamibi gated MPS studies of 40 females and 40 males with low likelihood ( or = 70% by the MF method was 0.92 +/- 0.04 versus 0.89 +/- 0.04 by standard quantification (P = not significant). The computation time for automated MF quantification and warping was <25 s for each case. We have developed a novel technique for display and quantification of gated myocardial perfusion images, which retrospectively eliminates blur due to cardiac motion. Such processing of gated MPS appears to improve the effective resolution of images. Initial evaluation indicates that it may improve the accuracy of gated MPS in detection of coronary artery disease.
- 1 July 2004
- Vol. 45 (7) , 1128-34
"Motion-frozen" display and quantification of myocardial perfusion.
Gated myocadial perfusion SPECT (MPS) incorporates functional and perfusion information of the left ventricle (LV). To improve the image quality and accuracy of gated MPS we propose to eliminate the influence of cardiac LV motion in the display and quantification by a novel "motion-frozen" (MF) technique. Three-dimensional LV contours were identified on images of the individual time phases. Three-dimensional phase-to-phase motion vectors were derived by sampling of the epi- and endocardial surfaces. A nonlinear image warping (thin-plate spline) was applied to warp all image phases to fit the end-diastolic (ED) phase. Warped images were created to provide the LV image in the ED phase but containing counts from an arbitrary number of time intervals. MF quantification has been performed using the same phase-to-phase motion vectors. MF normal perfusion limits were created from (99m)Tc sestamibi gated MPS studies of 40 females and 40 males with low likelihood ( or = 70% by the MF method was 0.92 +/- 0.04 versus 0.89 +/- 0.04 by standard quantification (P = not significant). The computation time for automated MF quantification and warping was <25 s for each case. We have developed a novel technique for display and quantification of gated myocardial perfusion images, which retrospectively eliminates blur due to cardiac motion. Such processing of gated MPS appears to improve the effective resolution of images. Initial evaluation indicates that it may improve the accuracy of gated MPS in detection of coronary artery disease.
- 1 February 2004
- Vol. 45 (2) , 183-91
Automatic quantification of myocardial perfusion stress-rest change: a new measure of ischemia.
In myocardial perfusion SPECT (MPS), ischemia is typically quantified as the difference between stress and rest defect sizes obtained by separate comparisons with stress and rest normal limits. Such an approach is not optimal because images are not compared directly with each other and a complex set of stress and rest normal limits is required. We developed a fully automatic technique to quantify stress-rest change. We applied it to 204 patients whose SPECT images were acquired using a same-day dual-isotope (99m)Tc/(201)Tl protocol and on whom coronary angiography had been performed. A 10-parameter registration of rest and stress images was performed by an iterative search of best translational, rotational, scaling, and optimal stress-rest count normalization parameters. Identical stress-rest 3-dimensional left ventricle (LV) contours were automatically derived from stress images. Integrated deficit counts (normalized rest-stress) within the LV volume were derived from registered image pairs. A global measure of ischemia (ISCH) was calculated as the ratio of the total deficit stress LV counts to the total rest LV counts. Registration and derivation of quantitative measures were fully automatic. The average processing time was <40 s on a 2-GHz processor. When compared for prediction of stenosis, the area under the receiver operating characteristic curve (0.88 +/- 0.03) was significantly better for ISCH than that obtained by existing quantitative approaches, which use reference databases (0.80-0.82 +/- 0.03). The normalized stress-rest change could be visualized and localized directly on raw patient images using overlay display. Automatic stress-rest MPS image registration allows a direct estimation of ischemia from SPECT that does not require comparisons with normal limits.
- 1 February 2004
- Vol. 45 (2) , 183-91
Automatic quantification of myocardial perfusion stress-rest change: a new measure of ischemia.
In myocardial perfusion SPECT (MPS), ischemia is typically quantified as the difference between stress and rest defect sizes obtained by separate comparisons with stress and rest normal limits. Such an approach is not optimal because images are not compared directly with each other and a complex set of stress and rest normal limits is required. We developed a fully automatic technique to quantify stress-rest change. We applied it to 204 patients whose SPECT images were acquired using a same-day dual-isotope (99m)Tc/(201)Tl protocol and on whom coronary angiography had been performed. A 10-parameter registration of rest and stress images was performed by an iterative search of best translational, rotational, scaling, and optimal stress-rest count normalization parameters. Identical stress-rest 3-dimensional left ventricle (LV) contours were automatically derived from stress images. Integrated deficit counts (normalized rest-stress) within the LV volume were derived from registered image pairs. A global measure of ischemia (ISCH) was calculated as the ratio of the total deficit stress LV counts to the total rest LV counts. Registration and derivation of quantitative measures were fully automatic. The average processing time was <40 s on a 2-GHz processor. When compared for prediction of stenosis, the area under the receiver operating characteristic curve (0.88 +/- 0.03) was significantly better for ISCH than that obtained by existing quantitative approaches, which use reference databases (0.80-0.82 +/- 0.03). The normalized stress-rest change could be visualized and localized directly on raw patient images using overlay display. Automatic stress-rest MPS image registration allows a direct estimation of ischemia from SPECT that does not require comparisons with normal limits.
- 1 October 2003
- Vol. 44 (10) , 1633-40
Prognostic implications of combined prone and supine acquisitions in patients with equivocal or abnormal supine myocardial perfusion SPECT.
Although acquisition of (99m)Tc-sestamibi myocardial perfusion SPECT (MPS) with the patient in the prone position is commonly used to minimize attenuation artifacts, the impact of combined prone and supine imaging on the prognostic evaluation of coronary artery disease (CAD) has not been determined. The prognostic implications of MPS obtained in both prone and supine positions in patients with perfusion defects on supine MPS were evaluated. We studied 3,834 patients who were monitored for 24.2 +/- 6.0 mo after rest (201)Tl/stress (99m)Tc-sestamibi MPS acquired during 1994-1995, when prone acquisition was performed only in patients with inferior wall perfusion defects that might represent attenuation or motion artifact. During follow-up, there were 132 hard events (cardiac death or myocardial infarction) and 375 total events (hard events or late myocardial revascularization). Overall, patients who underwent prone and supine acquisitions had similar characteristics to those who underwent supine-only imaging, with the exception of being more commonly male. In multivariable analysis, there were similar independent predictors for hard events and total events; the type of acquisition (prone and supine or supine-only) was not a significant predictor of either of these outcome events. After risk adjustment, the predicted event rates were nearly identical for patients undergoing prone and supine compared with supine-only studies. Both observed and predicted hard event rates of patients with normal prone and supine versus supine-only imaging were very low (observed, 0.7%/y and 0.5%/y, respectively; predicted, 1.5% over 24 mo for both). There was no reduction in the higher rates of events associated with abnormal scan results with the combination of prone and supine imaging. Patients with inferior wall defects on supine MPS that are not present on prone MPS have a low risk of subsequent cardiac events, similar to that of patients with normal supine-only studies.
- 1 October 2003
- Vol. 44 (10) , 1633-40
Prognostic implications of combined prone and supine acquisitions in patients with equivocal or abnormal supine myocardial perfusion SPECT.
Although acquisition of (99m)Tc-sestamibi myocardial perfusion SPECT (MPS) with the patient in the prone position is commonly used to minimize attenuation artifacts, the impact of combined prone and supine imaging on the prognostic evaluation of coronary artery disease (CAD) has not been determined. The prognostic implications of MPS obtained in both prone and supine positions in patients with perfusion defects on supine MPS were evaluated. We studied 3,834 patients who were monitored for 24.2 +/- 6.0 mo after rest (201)Tl/stress (99m)Tc-sestamibi MPS acquired during 1994-1995, when prone acquisition was performed only in patients with inferior wall perfusion defects that might represent attenuation or motion artifact. During follow-up, there were 132 hard events (cardiac death or myocardial infarction) and 375 total events (hard events or late myocardial revascularization). Overall, patients who underwent prone and supine acquisitions had similar characteristics to those who underwent supine-only imaging, with the exception of being more commonly male. In multivariable analysis, there were similar independent predictors for hard events and total events; the type of acquisition (prone and supine or supine-only) was not a significant predictor of either of these outcome events. After risk adjustment, the predicted event rates were nearly identical for patients undergoing prone and supine compared with supine-only studies. Both observed and predicted hard event rates of patients with normal prone and supine versus supine-only imaging were very low (observed, 0.7%/y and 0.5%/y, respectively; predicted, 1.5% over 24 mo for both). There was no reduction in the higher rates of events associated with abnormal scan results with the combination of prone and supine imaging. Patients with inferior wall defects on supine MPS that are not present on prone MPS have a low risk of subsequent cardiac events, similar to that of patients with normal supine-only studies.