GGGuido Germano

Guido Germano

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Guido Germano has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Gated SPECT MPI Processing and Quantitation

    by Piotr J. Slomka, Guido Germano, Daniel S. Berman

    Gated MPS provides an accurate and reproducible method for measuring myocardial perfusion at stress and rest as well as LVEF, EDV, ESV and diastolic function. It also provides a means of assessing regional wall motion abnormality, either at rest or post-stress. These functions and perfusion measurements obtained from gated MPS complement each other in CAD diagnosis as well as risk stratification. This chapter presents a comprehensive review of techniques used in gated SPECT processing to quantify function and perfusion, including the latest techniques and developments.


  • Advances in Nuclear Cardiac Instrumentation with a View Towards Reduced Radiation Exposure

    by Piotr J. Slomka, Damini Dey, W. Lane Duvall, Milena J. Henzlova, Daniel S. Berman, Guido Germano

    Recent advances in nuclear cardiology instrumentation have enabled myocardial perfusion imaging (MPI) with improved image quality and faster scan times. These developments also can be exploited to reduce the effective radiation dose to the patient. In this review, we discuss these technologies including new single photon emission computed tomography (SPECT) and positron emission tomography (PET) scanners, as well as novel reconstruction software with regard to their potential for the reduction of the patient radiation dose. New advances in nuclear cardiology instrumentation will allow routine rest/stress MPI imaging with low radiation doses (<5 mSv) and fast imaging times, even by the software-only solutions. It is possible to further reduce the MPI radiation dose to less than 2 to 3 mSv range with standard acquisition times. PET perfusion imaging also can be performed with very low doses especially by the three-dimensional scanners allowing hybrid PET/computed tomographic angiography (CTA) imaging with low overall dose. In addition, stress-only protocols can be utilized to further reduce the radiation dose and the overall test time.


  • Tracking a therapeutic response: How reliable are serial measurements of LV perfusion and function?

    by Guido Germano, Paul B. Kavanagh, Piotr J. Slomka, Daniel S. Berman


    • 1 July 2009
      • Vol. 21  (7) , 352-8

    Comparative roles of cardiac CT and nuclear cardiology in assessment of the patient with suspected coronary artery disease.

    by Daniel S Berman, Aiden Abidov, Rory Hachamovitch, James K Min, Piotr J Slomka, Guido Germano, Leslee J Shaw


  • Open Access

    Myocardial wall thickening from gated Magnetic Resonance images using Laplace’s equation

    by M. Prasad, A. Ramesh, P. Kavanagh, J. Gerlach, G. Germano, D. S. Berman, P. J. Slomka

    The aim of our work is to present a robust 3D automated method for measuring regional myocardial thickening using cardiac magnetic resonance imaging (MRI) based on Laplace’s equation. Multiple slices of the myocardium in short-axis orientation at end-diastolic and end-systolic phases were considered for this analysis. Automatically assigned 3D epicardial and endocardial boundaries were fitted to short-axis and long axis slices corrected for breathold related misregistration, and final boundaries were edited by a cardiologist if required. Myocardial thickness was quantified at the two cardiac phases by computing the distances between the myocardial boundaries over the entire volume using Laplace’s equation. The distance between the surfaces was found by computing normalized gradients that form a vector field. The vector fields represent tangent vectors along field lines connecting both boundaries. 3D thickening measurements were transformed into polar map representation and 17-segment model (American Heart Association) regional thickening values were derived. The thickening results were then compared with standard 17-segment 6-point visual scoring of wall motion/wall thickening (0=normal; 5=greatest abnormality) performed by a consensus of two experienced imaging cardiologists. Preliminary results on eight subjects indicated a strong negative correlation (r=−0.8, p<0.0001) between the average thickening obtained using Laplace and the summed segmental visual scores. Additionally, quantitative ejection fraction measurements also correlated well with average thickening scores (r=0.72, p<0.0001). For segmental analysis, we obtained an overall correlation of −0.55 (p<0.0001) with higher agreement along the mid and apical regions (r=−0.6). In conclusion 3D Laplace transform can be used to quantify myocardial thickening in 3D.


  • Feature-based non-rigid volume registration of serial coronary CT angiography

    by Jonghye Woo, Byung-Woo Hong, Damini Dey, Victor Cheng, Amit Ramesh, Ganesh Sundaramoorthi, C.-C. Jay Kuo, Daniel S. Berman, Guido Germano, Piotr J. Slomka

    Coronary CT angiography (CTA) with multi-slice helical scanners is becoming the integral part of major diagnostic pathways for coronary artery disease. In addition, coronary CTA has demonstrated substantial potential in quantitative coronary plaque characterization. If serial comparisons of plaque progression or regression are to be made, accurate 3D volume registration of these volumes would be particularly useful. In this work, we propose a coronary CTA volume registration of the paired coronary CTA scans using feature-based non-rigid volume registration. We achieve this with a combined registration strategy, which uses the global rigid registration as an initialization, followed by local registration using non-rigid volume registration with a volume preserving constraint. We exploit the extracted coronary trees to help localize and emphasize the region of interest as unnecessary regions hinder registration process, which results in wrong registration result. The extracted binary masks of each coronary tree may not be the same due to initial segmentation errors, which could lead to subsequent bias in the registration process. Therefore we utilize a blur mask which is generated by convolving the Gaussian function with the binary coronary tree mask to include the neighboring vessel region into account. A volume preserving constraint is imposed so that the total volume of the binary mask before and after co-registration remains constant. To validate the proposed method, we perform experiments with data from 3 patients with available serial CT scans (6 scans in total) and measure the distance of anatomical landmarks between the registered serial scans of the same patient.

  • Stress Testing and Imaging Protocols

    by Sean W. Hayes, Daniel S. Berman, Guido Germano


    • 1 July 2006
      • Vol. 47  (7) , 1107-18

    Roles of nuclear cardiology, cardiac computed tomography, and cardiac magnetic resonance: Noninvasive risk stratification and a conceptual framework for the selection of noninvasive imaging tests in patients with known or suspected coronary artery disease.

    by Daniel S Berman, Rory Hachamovitch, Leslee J Shaw, John D Friedman, Sean W Hayes, Louise E J Thomson, David S Fieno, Guido Germano, Nathan D Wong, Xingping Kang, et al.

    This review deals with noninvasive imaging for risk stratification and with a conceptual approach to the selection of noninvasive tests in patients with suspected or known chronic coronary artery disease (CAD). Already widely acknowledged with SPECT, there is an increasing body of literature data demonstrating that CT coronary calcium assessment is also of prognostic value. The amount of coronary atherosclerosis, as can be extrapolated from CT coronary calcium score, has been shown to be highly predictive of cardiac events. The principal difference between myocardial perfusion SPECT (MPS) and CT coronary calcium for prognostic application appears to be that the former is an excellent tool for assessing short-term risk, thus effectively guiding decisions regarding revascularization. In contrast, the atherosclerosis imaging methods are likely to provide greater long-term risk assessment and, thus, are more useful in determination of the need for aggressive medical prevention measures. Although the more recent development of CT coronary angiography is promising for diagnosis, there has been no information to date regarding the prognostic value of the CT angiographic data. Similarly, cardiac MRI has not yet been adequately studied for its prognostic content. The selection of the most appropriate test for a given patient depends on the specific question being asked. In patients with a very low likelihood of CAD, no imaging test may be required. In screening the remaining asymptomatic patients, atherosclerosis imaging may be beneficial. In symptomatic patients, MPS, CT coronary angiography, and cardiac MRI play important roles. We consider it likely that, with an increased emphasis on prevention and a concomitant aging of the population, many forms of noninvasive cardiac imaging will continue to grow, with nuclear cardiology continuing to grow.


    • 1 December 2004
      • Vol. 45  (12) , 1978-80

    Quantification of serial changes in myocardial perfusion.

    by Piotr J Slomka, Daniel S Berman, Guido Germano


    • 1 December 2004
      • Vol. 45  (12) , 1999-2007

    Integration of automatically measured transient ischemic dilation ratio into interpretation of adenosine stress myocardial perfusion SPECT for detection of severe and extensive CAD.

    by Aiden Abidov, Jeroen J Bax, Sean W Hayes, Ishac Cohen, Hidetaka Nishina, Shunichi Yoda, Xingping Kang, Fatma Aboul-Enein, James Gerlach, John D Friedman, et al.

    The aim of our study was to derive and to validate the normal threshold for an automatically measured left ventricular transient ischemic dilation (TID) ratio in patients referred for adenosine stress myocardial perfusion SPECT (MPS) and to assess the value of integrating TID in detecting severe and extensive coronary artery disease (CAD). Normal limits for the TID ratio were derived using dual-isotope MPS data from 38 patients with a low ( or =90% stenosis) in the proximal left anterior descending artery or in 2 or more coronary arteries, 64 (36%) had no significant CAD ( 1.36). Abnormal TID ratio using this threshold demonstrated high sensitivity and specificity for severe and extensive CAD (71% and 86%, respectively), and similar sensitivity and specificity were observed in the prospective validation group (73% and 88%, respectively). In the combined pilot and validation groups, the absence of both abnormal TID ratio and abnormal perfusion was highly specific for the absence of severe and extensive CAD; only one (1.3%) of 79 patients with severe and extensive CAD had neither of these abnormal findings on adenosine MPS. In patients with both abnormal TID ratio and abnormal perfusion, 55 of 84 (65%) had severe and extensive CAD. When patients had one but not both of these findings, 26 of 193 (13%) had severe and extensive CAD. The automatically measured TID ratio is a useful clinical marker that is sensitive and highly specific for identification of severe and extensive CAD in patients undergoing adenosine MPS. Integration of abnormal TID ratio into the dual-isotope MPS image interpretation algorithm improves the identification of severe and extensive CAD in adenosine MPS.