ASAsheesh Kumar Singh

Asheesh Kumar Singh

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Asheesh Kumar Singh has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Approximated fuzzy logic controlled shunt active power filter for improved power quality

    by Rambir Singh, Asheesh K. Singh, Rakesh K. Arya

    Shunt active power filters have been widely used for power quality improvement. With the advancement in artificial intelligence techniques, the applications of fuzzy logic‐based control systems have increased manifolds. This paper proposes a reduced rule fuzzy logic controller (FLC) in the voltage control loop of a shunt active power filter (APF), which is approximating a conventional large rule FLC. The difference between the controlled outputs of two controllers is compensated by proposed compensating factors. The dynamic response and harmonic compensation performance of proposed 4‐rule approximated fuzzy logic controller (AFLC) is compared with 25‐rule FLC. A three‐phase shunt APF is used for harmonic and reactive power compensation. The proposed scheme is tested with randomly varying single and multiple non‐linear loads. The simulation results presented under transient and steady‐state conditions confirm that the proposed 4‐rule AFLC efficiently approximates the 25‐rule FLC. The proposed control methodology takes less computational time and computational memory as the numbers of rules are reduced significantly.


  • Some Observations on Definitions of Voltage Unbalance

    by Asheesh K. Singh, G. K. Singh, R. Mitra

    In this paper an analysis of five different definitions of voltage unbalance developed by various power communities (CIGRE, NEMA, IEEE, and IEC) is presented, in order to understand their performance and difference among them. The purpose of this work is to analyze and quantify the voltage unbalance, so that these results may become useful to minimize the harmful effects of voltage unbalance. To quantify the voltage unbalance, five existing voltage unbalance definitions are calculated and their numerical values are used in analyzing the behavior of these definitions for the unit change in their magnitude and angle of voltage phasors.


  • Some Observations on Multiplicity and Operating/Processing Modes of PC Loads with UPS

    by A.K. Singh, G.K. Singh, R. Mitra

    Presently computer loads and systems are extensively used almost in every field of daily life, where computers have to play very important and decisive role like healthcare, banking, safety systems etc. These critical facilities rely on uninterruptible power supply (UPS) to maintain a continuous supply of power, during power failure and to provide reliable service. The UPS supplies the mean power to PC load connected to it, but this combination of LIPS and PC load works as a harmonic source. This paper reports some experimental measurement results about harmonic currents generated by single and multiple personal computer (PC) loads connected with UPS, as in most practical conditions the UPS is found connected to PC load. Furthermore, to investigate the impact of UPS connected with PC load, a comparative study is also presented, where measurements are taken under two different conditions, i.e. PC load without UPS and with UPS. Two processing modes are investigated, i.e. idle mode, and hard disc drive (HDD) processing mode. The measurements taken for these two processing modes are combined with two different conditions of monitor status: with monitor power ON and with monitor power OFF. Parameters considered for investigation are mis load current, its harmonic distortion, power consumption and harmonic spectrum of load current. Attenuation of harmonic components due to multiplicity of PC load is also studied.

  • Evaluation of Harmonic Distortion under Unbalanced Supply Conditions

    by Asheesh Kumar Singh, G. K. Singh, R. Mitra

    This paper presents a detailed study on the effect of power system voltage unbalance on the harmonics injected by a ac-dc rectifier load. This study gives an insight about the role of sequence voltage components in voltage unbalance analysis. The simulations are carried out in time domain and the frequency spectra of the distorted waveform (input and output) are obtained using fast Fourier transform (FFT). The variation of different characteristic and non-characteristic harmonics with the degree of unbalance is also investigated. A full understanding of sensitivity of the current harmonic components to different unbalance voltage operating conditions is also obtained. A new terminology named as phase total harmonic distortion unbalance factor (PTHDUF) is introduced.