RMR. Mitra

R. Mitra

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


R. Mitra has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Design of Type-2 Fuzzy Controller based on LQR Mapped Fusion Function

    by Abhishek Kumar, Sudeep Sharma, R. Mitra

    Rule number explosion‖ in fuzzy controller and-uncertainty‖ in the model are two main issues in the design of fuzzy control systems. To overcome these problems, we have applied a method in which a linear sensory fusion function has been used to reduce the number of dimensions of fuzzy controller's inputs and simultaneously use the features of LQR control. Since, in type-2 fuzzy control, the degree of fuzziness increased and it can better handle the uncertainty in the model compared to conventional fuzzy, so the method of sensory fusion with type-2 fuzzy control scheme has been combined to make the controller more robust w.r.t. the parameter variation, perturbation and uncertainty in the model. Performance criteria like IAE, ISE and ITAE have been used to compare the control performance obtained from conventional fuzzy and type-2 fuzzy controller.


  • Some Observations on Definitions of Voltage Unbalance

    by Asheesh K. Singh, G. K. Singh, R. Mitra

    In this paper an analysis of five different definitions of voltage unbalance developed by various power communities (CIGRE, NEMA, IEEE, and IEC) is presented, in order to understand their performance and difference among them. The purpose of this work is to analyze and quantify the voltage unbalance, so that these results may become useful to minimize the harmful effects of voltage unbalance. To quantify the voltage unbalance, five existing voltage unbalance definitions are calculated and their numerical values are used in analyzing the behavior of these definitions for the unit change in their magnitude and angle of voltage phasors.


  • Some Observations on Multiplicity and Operating/Processing Modes of PC Loads with UPS

    by A.K. Singh, G.K. Singh, R. Mitra

    Presently computer loads and systems are extensively used almost in every field of daily life, where computers have to play very important and decisive role like healthcare, banking, safety systems etc. These critical facilities rely on uninterruptible power supply (UPS) to maintain a continuous supply of power, during power failure and to provide reliable service. The UPS supplies the mean power to PC load connected to it, but this combination of LIPS and PC load works as a harmonic source. This paper reports some experimental measurement results about harmonic currents generated by single and multiple personal computer (PC) loads connected with UPS, as in most practical conditions the UPS is found connected to PC load. Furthermore, to investigate the impact of UPS connected with PC load, a comparative study is also presented, where measurements are taken under two different conditions, i.e. PC load without UPS and with UPS. Two processing modes are investigated, i.e. idle mode, and hard disc drive (HDD) processing mode. The measurements taken for these two processing modes are combined with two different conditions of monitor status: with monitor power ON and with monitor power OFF. Parameters considered for investigation are mis load current, its harmonic distortion, power consumption and harmonic spectrum of load current. Attenuation of harmonic components due to multiplicity of PC load is also studied.

  • Impact of Source Voltage Unbalance on AC-DC Rectifier Performance

    by Asheesh Kumar Singh, G. K. Singh, R. Mitra

    This paper presents a comprehensive study about the impact of source voltage unbalance on the performance of a three-phase ac-dc rectifier along with the harmonics injected by the rectifier load. The variation of different characteristic and non-characteristic harmonics with the degree of unbalance is investigated. The study also includes the effect of source voltage unbalance on harmonic distortion of different input and output characteristics of the rectifier. Since, the voltage sequence components play an important role in describing a more clear view of degree of voltage unbalance, an attempt has been made to identify the impact of sequence voltage components on total harmonic distortion and individual harmonic components in different phases. A full understanding of sensitivity of the current harmonic components to different unbalance voltage operating conditions is also obtained. To describe the unbalance in total harmonic distortion of current (THDI) in three different phases, a new term "phase total harmonic distortion unbalance factor" (PTHDUF) is introduced. It was found that PTHDUF is proportional to the degree of unbalance/voltage unbalance factor (VUF).


  • A Robust Scheme for Tuning of Fuzzy PI Type Controller

    by Seema Chopra, R. Mitra, Vijay Kumar

    In this paper, a simple and effective scheme for tuning of fuzzy PI (proportional-integral) controller based on fuzzy logic is proposed. Here the input scaling factors are tuned online by gain updating factors whose values are determined by rule base with the error and change in error as inputs according to the required controlled process. The performance comparison of conventional fuzzy logic controller with auto tuned fuzzy PI type controllers has been done in terms of several performance measures such as peak overshoot, settling time and rise time and integral square error (ISE). In addition to the responses due to step set-point change, a random noise is also added in some systems. Simulation results show the effectiveness and robustness of the proposed tuning mechanism. Furthermore, a clustering method is used to reduce the fuzzy inference rules of the three fuzzy reasoning blocks which reduces the computational time and memory. The clustering based fuzzy logic controllers is compared with those of conventional fuzzy logic controllers in both cases (with and without tuning). A simulation analysis of a wide range of linear and nonlinear processes is carried out and comparison of results shows computational time and memory is reduced to a great extent


  • Evaluation of Harmonic Distortion under Unbalanced Supply Conditions

    by Asheesh Kumar Singh, G. K. Singh, R. Mitra

    This paper presents a detailed study on the effect of power system voltage unbalance on the harmonics injected by a ac-dc rectifier load. This study gives an insight about the role of sequence voltage components in voltage unbalance analysis. The simulations are carried out in time domain and the frequency spectra of the distorted waveform (input and output) are obtained using fast Fourier transform (FFT). The variation of different characteristic and non-characteristic harmonics with the degree of unbalance is also investigated. A full understanding of sensitivity of the current harmonic components to different unbalance voltage operating conditions is also obtained. A new terminology named as phase total harmonic distortion unbalance factor (PTHDUF) is introduced.