Marcin Wierszycki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Marcin Wierszycki has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Krzysztof Szajek
Poznan University of Technology
4 shared publications - Tomasz Łodygowski
Institute of Powertrains and Aviation, Poznan University of Technology, Piotrowo 3, 61-139 Poznań, Poland
3 shared publications - Michał Nowak
Poznan University of Technology
1 shared publication - Rafał Zagalak
Foundation of University of Medical Sciences
1 shared publication Tomasz Topoliński
1 shared publication- Wiesław Hędzelek
Department of Prosthetic Dentistry, University of Medical Sciences of Poznan, Poland
1 shared publication
Latest Publications
- 1 January 2016
- Vol. 18 (1) , 103-13
Numerical verification of two-component dental implant in the context of fatigue life for various load cases.
Dental implant designing is a complex process which considers many limitations both biological and mechanical in nature. In earlier studies, a complete procedure for improvement of two-component dental implant was proposed. However, the optimization tasks carried out required assumption on representative load case, which raised doubts on optimality for the other load cases. This paper deals with verification of the optimal design in context of fatigue life and its main goal is to answer the question if the assumed load scenario (solely horizontal occlusal load) leads to the design which is also "safe" for oblique occlussal loads regardless the angle from an implant axis. The verification is carried out with series of finite element analyses for wide spectrum of physiologically justified loads. The design of experiment methodology with full factorial technique is utilized. All computations are done in Abaqus suite. The maximal Mises stress and normalized effective stress amplitude for various load cases are discussed and compared with the assumed "safe" limit (equivalent of fatigue life for 5e6 cycles). The obtained results proof that coronial-appical load component should be taken into consideration in the two component dental implant when fatigue life is optimized. However, its influence in the analyzed case is small and does not change the fact that the fatigue life improvement is observed for all components within whole range of analyzed loads.
- 1 January 2016
- Vol. 18 (1) , 103-13
Numerical verification of two-component dental implant in the context of fatigue life for various load cases.
Dental implant designing is a complex process which considers many limitations both biological and mechanical in nature. In earlier studies, a complete procedure for improvement of two-component dental implant was proposed. However, the optimization tasks carried out required assumption on representative load case, which raised doubts on optimality for the other load cases. This paper deals with verification of the optimal design in context of fatigue life and its main goal is to answer the question if the assumed load scenario (solely horizontal occlusal load) leads to the design which is also "safe" for oblique occlussal loads regardless the angle from an implant axis. The verification is carried out with series of finite element analyses for wide spectrum of physiologically justified loads. The design of experiment methodology with full factorial technique is utilized. All computations are done in Abaqus suite. The maximal Mises stress and normalized effective stress amplitude for various load cases are discussed and compared with the assumed "safe" limit (equivalent of fatigue life for 5e6 cycles). The obtained results proof that coronial-appical load component should be taken into consideration in the two component dental implant when fatigue life is optimized. However, its influence in the analyzed case is small and does not change the fact that the fatigue life improvement is observed for all components within whole range of analyzed loads.
- Open Access
- 20 February 2014
- Published by Springer Nature in Computational Mechanics
- Vol. 54 (2) , 287-298
A two-scale approach for trabecular bone microstructure modeling based on computational homogenization procedure
- 20 February 2014
- Published by Springer Nature in Computational Mechanics
- Vol. 54 (2) , 287-298
Open AccessA two-scale approach for trabecular bone microstructure modeling based on computational homogenization procedure
- 1 January 2010
- Published by Springer Nature
- p. 391-422
Tooth-Implant Life Cycle Design