Doris Franke
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Doris Franke has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Alexandros Rahn
Department of Pediatric Pulmonology, Allergology and Neonatology, Hannover Medical School, Hannover, Germany
3 shared publications - Thomas Müller
Department of Pediatric Pulmonology, Allergology and Neonatology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany
3 shared publications - Aikaterini Ntoulia
Department of Radiology, Children’s Hospital of Philadelphia, Philadelphia, USA
2 shared publications - Diane Miriam Renz
Department of Pediatric Radiology, Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany
2 shared publications Hans-Joachim Mentzel
Sektion Kinderradiologie, Institut für Diagnostische und Interventionelle Radiologie, Universitätsklinikum Jena, Jena, Deutschland
2 shared publications- Jochen H. H. Ehrich
Children’s Hospital, Hannover Medical School, 30625 Hannover, Germany
2 shared publications
Latest Publications
- Open Access
- 28 October 2026
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 185 (11) , 898
Organ size in small infants (The OSSI Study): are sonographic reference intervals applicable in preterm infants small for gestational age?
Sonographic reference intervals for liver, spleen, and kidney size in preterm infants below 40 cm body length were recently established in an appropriately grown (AGA) neonatal cohort. Whether these intervals apply to infants born small for gestational age (SGA) remains unexamined. In this cross-sectional study, 20 preterm SGA infants below 40 cm body length (mean gestational age 29 1 / 7 weeks, median birth weight 695 g) underwent standardized abdominal ultrasound, measuring craniocaudal liver length in three planes, splenic length, and renal volume. Measurements were compared with published reference intervals, and z-scores assessed systematic deviation. Weight and length at examination were comparable between the SGA and AGA cohorts. The mean z-score was significantly below zero only for liver length in the midclavicular line (− 0.79, p = 0.014). The proportion of infants outside the reference interval exceeded the expected 5% for liver length in the midclavicular line (25%, p = 0.003) and anterior axillary line (20%, p = 0.016) and for spleen length (20%, p = 0.016), but rested on 4 to 5 infants each, and several values lay within 1 mm of the limit. Kidney measurements did not differ from the reference. Organ size correlated most strongly with body weight, and the deviations persisted at equal weight (post hoc). Conclusion : Abdominal organ dimensions in SGA preterm infants frequently fall outside AGA-derived reference intervals, particularly for liver and spleen size, suggesting that these intervals cannot be reliably applied to this population. Prospective studies establishing reference values for SGA infants are warranted. What is Known: • Sonographic reference intervals for abdominal organ size in preterm infants below 40 cm exist only for appropriately grown (AGA) infants; their applicability to infants small for gestational age (SGA) has not been examined . What is New: • In 20 preterm SGA infants, the mean z-score for liver length (midclavicular line) was below the AGA reference, and liver and spleen lengths fell outside the intervals more often than the expected 5% (exploratory) . • AGA intervals should not be assumed to apply to SGA infants .
- 28 October 2026
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 185 (11) , 898
Open AccessOrgan size in small infants (The OSSI Study): are sonographic reference intervals applicable in preterm infants small for gestational age?
Sonographic reference intervals for liver, spleen, and kidney size in preterm infants below 40 cm body length were recently established in an appropriately grown (AGA) neonatal cohort. Whether these intervals apply to infants born small for gestational age (SGA) remains unexamined. In this cross-sectional study, 20 preterm SGA infants below 40 cm body length (mean gestational age 29 1 / 7 weeks, median birth weight 695 g) underwent standardized abdominal ultrasound, measuring craniocaudal liver length in three planes, splenic length, and renal volume. Measurements were compared with published reference intervals, and z-scores assessed systematic deviation. Weight and length at examination were comparable between the SGA and AGA cohorts. The mean z-score was significantly below zero only for liver length in the midclavicular line (− 0.79, p = 0.014). The proportion of infants outside the reference interval exceeded the expected 5% for liver length in the midclavicular line (25%, p = 0.003) and anterior axillary line (20%, p = 0.016) and for spleen length (20%, p = 0.016), but rested on 4 to 5 infants each, and several values lay within 1 mm of the limit. Kidney measurements did not differ from the reference. Organ size correlated most strongly with body weight, and the deviations persisted at equal weight (post hoc). Conclusion : Abdominal organ dimensions in SGA preterm infants frequently fall outside AGA-derived reference intervals, particularly for liver and spleen size, suggesting that these intervals cannot be reliably applied to this population. Prospective studies establishing reference values for SGA infants are warranted. What is Known: • Sonographic reference intervals for abdominal organ size in preterm infants below 40 cm exist only for appropriately grown (AGA) infants; their applicability to infants small for gestational age (SGA) has not been examined . What is New: • In 20 preterm SGA infants, the mean z-score for liver length (midclavicular line) was below the AGA reference, and liver and spleen lengths fell outside the intervals more often than the expected 5% (exploratory) . • AGA intervals should not be assumed to apply to SGA infants .
- Open Access
- 30 June 2026
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 185 (7)
Bubbles in the barely born—contrast-enhanced ultrasound in neonates: a single-center experience
To assess clinical value, safety, and applicability of contrast-enhanced ultrasound (CEUS) in neonates, focusing on bedside use in intensive care. This retrospective single-center study included 23 neonates undergoing intravenous CEUS between 2010 and 2024, including seven preterm infants. The liver ( n = 18) was the most frequently examined organ, followed by kidneys ( n = 2), brain ( n = 2), and adrenals ( n = 1). Findings were compared with MRI ( n = 10), CT ( n = 3), or biopsy ( n = 8), when available. In nine cases, CEUS findings were consistent with clinical course and treatment response only, without an independent reference standard. Among the 14 cases with available reference diagnostics, CEUS established the diagnosis first in ten (71.4%); histological confirmation was available in eight cases, with concordance in five (62.5%). 13 examinations (56.5%) were performed for bedside problem-solving in the neonatal intensive care unit, and no adverse events were observed. Conclusion : CEUS provided clinically relevant diagnostic information in neonates, including preterm and critically ill infants and was well tolerated. CEUS was particularly valuable in hepatic vascular tumors, where it could provide a definite diagnosis, enabled hemodynamic assessment, supported treatment decisions, and aided identification of potentially life-threatening complications. Bedside use enabled timely diagnosis without sedation, intubation, or patient transport, thereby supporting minimal handling. In selected cases, CEUS may reduce the need for cross-sectional imaging. Despite off-label use, our findings suggest a beneficial role for CEUS in neonatal imaging, predominantly for hepatic indications. What is Known: • Contrast-enhanced ultrasound (CEUS) is a radiation-free, bedside-compatible imaging technique with an established safety profile in pediatric patients. • Neonatal CEUS experience is limited to small case series, predominantly reporting cerebral applications. What is New: • CEUS was feasible and well tolerated in neonates including preterm infants, with no adverse events in 23 examinations. • CEUS yielded clinically relevant diagnostic information across a range of indications, primarily hepatic, encompassing both focal lesions and perfusion assessment, supporting clinical decision-making in neonatal care.
- 30 June 2026
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 185 (7)
Open AccessBubbles in the barely born—contrast-enhanced ultrasound in neonates: a single-center experience
To assess clinical value, safety, and applicability of contrast-enhanced ultrasound (CEUS) in neonates, focusing on bedside use in intensive care. This retrospective single-center study included 23 neonates undergoing intravenous CEUS between 2010 and 2024, including seven preterm infants. The liver ( n = 18) was the most frequently examined organ, followed by kidneys ( n = 2), brain ( n = 2), and adrenals ( n = 1). Findings were compared with MRI ( n = 10), CT ( n = 3), or biopsy ( n = 8), when available. In nine cases, CEUS findings were consistent with clinical course and treatment response only, without an independent reference standard. Among the 14 cases with available reference diagnostics, CEUS established the diagnosis first in ten (71.4%); histological confirmation was available in eight cases, with concordance in five (62.5%). 13 examinations (56.5%) were performed for bedside problem-solving in the neonatal intensive care unit, and no adverse events were observed. Conclusion : CEUS provided clinically relevant diagnostic information in neonates, including preterm and critically ill infants and was well tolerated. CEUS was particularly valuable in hepatic vascular tumors, where it could provide a definite diagnosis, enabled hemodynamic assessment, supported treatment decisions, and aided identification of potentially life-threatening complications. Bedside use enabled timely diagnosis without sedation, intubation, or patient transport, thereby supporting minimal handling. In selected cases, CEUS may reduce the need for cross-sectional imaging. Despite off-label use, our findings suggest a beneficial role for CEUS in neonatal imaging, predominantly for hepatic indications. What is Known: • Contrast-enhanced ultrasound (CEUS) is a radiation-free, bedside-compatible imaging technique with an established safety profile in pediatric patients. • Neonatal CEUS experience is limited to small case series, predominantly reporting cerebral applications. What is New: • CEUS was feasible and well tolerated in neonates including preterm infants, with no adverse events in 23 examinations. • CEUS yielded clinically relevant diagnostic information across a range of indications, primarily hepatic, encompassing both focal lesions and perfusion assessment, supporting clinical decision-making in neonatal care.
- Open Access
- 28 May 2026
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 185 (6)
Organ size in small infants (The OSSI Study): establishing sonographic reference intervals for abdominal organs in preterm infants
Accurate ultrasound assessment of abdominal organ size in preterm infants is essential for evaluating growth and detecting abnormalities. However, standardized reference intervals for liver, spleen, and kidney dimensions in preterms below 40 cm body length are lacking. This study aimed to establish reference intervals for these organs. 57 eutrophic preterm infants with a body length below 40 cm (gestational age: 23 4 / 7 —31 5 / 7 weeks; birth length: 29—39.5 cm) were prospectively examined using a standardized ultrasound protocol recommended by the German Society for Ultrasound in Medicine (DEGUM). Craniocaudal liver length, spleen length, and renal volume were measured and correlated with corrected gestational age, body weight, and body length. Reference intervals were calculated from log-transformed data with 95% confidence intervals for reference limits. Portal vein peak velocity before feeding and presence of a patent ductus venosus (PDV) were additionally assessed. Organ dimensions correlated most closely with body weight, followed by body length and corrected gestational age, with renal volume showing the highest correlations overall. Reference intervals for liver, spleen, and renal size showed tight 95% confidence intervals. Portal vein peak velocity ranged from 9—29 cm/s. A PDV was present in 56%; these infants were younger at examination (10.9 vs. 17 days, p = 0.01). Conclusion : This study provides clinically relevant ultrasound reference intervals for abdominal organs in small preterm infants. These measurements may help distinguish physiological from pathological findings and guide clinical decision-making in neonatal care. What is Known: • Ultrasound is the preferred imaging modality for abdominal organ assessment in preterm infants, but standardized sonographic reference intervals for infants with a body length below 40 cm are lacking. What is New: • This study provides the first standardized sonographic reference intervals for liver length, splenic length, and renal volume in preterm infants below 40 cm body length, using a prospective, reproducible protocol aligned with DEGUM recommendations. • Organ size correlated most strongly with body weight, followed by body length and corrected gestational age, with renal volume showing the highest overall correlations across all parameters.
- 28 May 2026
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 185 (6)
Open AccessOrgan size in small infants (The OSSI Study): establishing sonographic reference intervals for abdominal organs in preterm infants
Accurate ultrasound assessment of abdominal organ size in preterm infants is essential for evaluating growth and detecting abnormalities. However, standardized reference intervals for liver, spleen, and kidney dimensions in preterms below 40 cm body length are lacking. This study aimed to establish reference intervals for these organs. 57 eutrophic preterm infants with a body length below 40 cm (gestational age: 23 4 / 7 —31 5 / 7 weeks; birth length: 29—39.5 cm) were prospectively examined using a standardized ultrasound protocol recommended by the German Society for Ultrasound in Medicine (DEGUM). Craniocaudal liver length, spleen length, and renal volume were measured and correlated with corrected gestational age, body weight, and body length. Reference intervals were calculated from log-transformed data with 95% confidence intervals for reference limits. Portal vein peak velocity before feeding and presence of a patent ductus venosus (PDV) were additionally assessed. Organ dimensions correlated most closely with body weight, followed by body length and corrected gestational age, with renal volume showing the highest correlations overall. Reference intervals for liver, spleen, and renal size showed tight 95% confidence intervals. Portal vein peak velocity ranged from 9—29 cm/s. A PDV was present in 56%; these infants were younger at examination (10.9 vs. 17 days, p = 0.01). Conclusion : This study provides clinically relevant ultrasound reference intervals for abdominal organs in small preterm infants. These measurements may help distinguish physiological from pathological findings and guide clinical decision-making in neonatal care. What is Known: • Ultrasound is the preferred imaging modality for abdominal organ assessment in preterm infants, but standardized sonographic reference intervals for infants with a body length below 40 cm are lacking. What is New: • This study provides the first standardized sonographic reference intervals for liver length, splenic length, and renal volume in preterm infants below 40 cm body length, using a prospective, reproducible protocol aligned with DEGUM recommendations. • Organ size correlated most strongly with body weight, followed by body length and corrected gestational age, with renal volume showing the highest overall correlations across all parameters.
- 5 January 2024
- Published by Springer Nature in Die Radiologie
- Vol. 64 (1) , 45-53
Bildgebung nach Nierentransplantation im Kindes- und Jugendalter
- 5 January 2024
- Published by Springer Nature in Die Radiologie
- Vol. 64 (1) , 45-53
Bildgebung nach Nierentransplantation im Kindes- und Jugendalter
- Open Access
- 3 September 2021
- Published by Springer Nature in Pediatric Nephrology
- Vol. 37 (7) , 1511-1522
The diagnostic value of Doppler ultrasonography after pediatric kidney transplantation
Ultrasonography (US) plays a major diagnostic role in the pre- and post-transplant evaluation of recipient and donor. In most cases, US remains the only necessary imaging modality. After pediatric kidney transplantation, US can ensure immediate bedside diagnosis of vessel patency and possible postoperative non-vascular complications. Criteria for US diagnosis of kidney vessel thrombosis and stenosis in the transplant will be presented. Non-vascular complications after kidney transplantation include hydronephrosis, hematoma, lymphocele, and abscess. US can detect suggestive, but nevertheless non-specific, acute signs (sudden increase in volume and elevated resistive index), and chronic rejection, which therefore remains a histological diagnosis. US is of little or no help in detection of tubular necrosis or drug toxicity, but it can exclude other differential diagnoses. This educational review provides a practical and systematic approach to a multimodal US investigation of the kidney transplant. It includes a short overview on possible indications for contrast-enhanced ultrasonography (CEUS) in children after kidney transplantation.
- 3 September 2021
- Published by Springer Nature in Pediatric Nephrology
- Vol. 37 (7) , 1511-1522
Open AccessThe diagnostic value of Doppler ultrasonography after pediatric kidney transplantation
Ultrasonography (US) plays a major diagnostic role in the pre- and post-transplant evaluation of recipient and donor. In most cases, US remains the only necessary imaging modality. After pediatric kidney transplantation, US can ensure immediate bedside diagnosis of vessel patency and possible postoperative non-vascular complications. Criteria for US diagnosis of kidney vessel thrombosis and stenosis in the transplant will be presented. Non-vascular complications after kidney transplantation include hydronephrosis, hematoma, lymphocele, and abscess. US can detect suggestive, but nevertheless non-specific, acute signs (sudden increase in volume and elevated resistive index), and chronic rejection, which therefore remains a histological diagnosis. US is of little or no help in detection of tubular necrosis or drug toxicity, but it can exclude other differential diagnoses. This educational review provides a practical and systematic approach to a multimodal US investigation of the kidney transplant. It includes a short overview on possible indications for contrast-enhanced ultrasonography (CEUS) in children after kidney transplantation.
- 24 August 2021
- Published by Springer Nature in Pediatric Radiology
- Vol. 51 (12) , 2229-2252
Contrast-enhanced ultrasound of the spleen, pancreas and gallbladder in children
Gray-scale and color/power Doppler ultrasound (US) are the first-line imaging modalities to evaluate the spleen, gallbladder and pancreas in children. The increasing use of contrast-enhanced ultrasound (CEUS) as a reliable and safe method to evaluate liver lesions in the pediatric population promises potential for imaging other internal organs. Although CEUS applications of the spleen, gallbladder and pancreas have been well described in adults, they have not been fully explored in children. In this manuscript, we present an overview of the applications of CEUS for normal variants and diseases affecting the spleen, gallbladder and pancreas. We highlight a variety of cases as examples of how CEUS can serve in the diagnosis and follow-up for such diseases in children. Our discussion includes specific examination techniques; presentation of the main imaging findings in various benign and malignant lesions of the spleen, gallbladder and pancreas in children; and acknowledgment of the limitations of CEUS for these organs.
- 24 August 2021
- Published by Springer Nature in Pediatric Radiology
- Vol. 51 (12) , 2229-2252
Contrast-enhanced ultrasound of the spleen, pancreas and gallbladder in children
Gray-scale and color/power Doppler ultrasound (US) are the first-line imaging modalities to evaluate the spleen, gallbladder and pancreas in children. The increasing use of contrast-enhanced ultrasound (CEUS) as a reliable and safe method to evaluate liver lesions in the pediatric population promises potential for imaging other internal organs. Although CEUS applications of the spleen, gallbladder and pancreas have been well described in adults, they have not been fully explored in children. In this manuscript, we present an overview of the applications of CEUS for normal variants and diseases affecting the spleen, gallbladder and pancreas. We highlight a variety of cases as examples of how CEUS can serve in the diagnosis and follow-up for such diseases in children. Our discussion includes specific examination techniques; presentation of the main imaging findings in various benign and malignant lesions of the spleen, gallbladder and pancreas in children; and acknowledgment of the limitations of CEUS for these organs.
- 12 May 2021
- Published by Springer Nature in Pediatric Radiology
- Vol. 51 (12) , 2284-2302
Contrast-enhanced ultrasound of transplant organs — liver and kidney — in children
Ultrasound (US) is the first-line imaging tool for evaluating liver and kidney transplants during and after the surgical procedures. In most patients after organ transplantation, gray-scale US coupled with color/power and spectral Doppler techniques is used to evaluate the transplant organs, assess the patency of vascular structures, and identify potential complications. In technically difficult or inconclusive cases, however, contrast-enhanced ultrasound (CEUS) can provide prompt and accurate diagnostic information that is essential for management decisions. CEUS is indicated to evaluate for vascular complications including vascular stenosis or thrombosis, active bleeding, pseudoaneurysms and arteriovenous fistulas. Parenchymal indications for CEUS include evaluation for perfusion defects and focal inflammatory and non-inflammatory lesions. When transplant rejection is suspected, CEUS can assist with prompt intervention by excluding potential underlying causes for organ dysfunction. Intracavitary CEUS applications can evaluate the biliary tract of a liver transplant (e.g., for biliary strictures, bile leak or intraductal stones) or the urinary tract of a renal transplant (e.g., for urinary obstruction, urine leak or vesicoureteral reflux) as well as the position and patency of hepatic, biliary and renal drains and catheters. The aim of this review is to present current experience regarding the use of CEUS to evaluate liver and renal transplants, focusing on the examination technique and interpretation of the main imaging findings, predominantly those related to vascular complications.
- 12 May 2021
- Published by Springer Nature in Pediatric Radiology
- Vol. 51 (12) , 2284-2302
Contrast-enhanced ultrasound of transplant organs — liver and kidney — in children
Ultrasound (US) is the first-line imaging tool for evaluating liver and kidney transplants during and after the surgical procedures. In most patients after organ transplantation, gray-scale US coupled with color/power and spectral Doppler techniques is used to evaluate the transplant organs, assess the patency of vascular structures, and identify potential complications. In technically difficult or inconclusive cases, however, contrast-enhanced ultrasound (CEUS) can provide prompt and accurate diagnostic information that is essential for management decisions. CEUS is indicated to evaluate for vascular complications including vascular stenosis or thrombosis, active bleeding, pseudoaneurysms and arteriovenous fistulas. Parenchymal indications for CEUS include evaluation for perfusion defects and focal inflammatory and non-inflammatory lesions. When transplant rejection is suspected, CEUS can assist with prompt intervention by excluding potential underlying causes for organ dysfunction. Intracavitary CEUS applications can evaluate the biliary tract of a liver transplant (e.g., for biliary strictures, bile leak or intraductal stones) or the urinary tract of a renal transplant (e.g., for urinary obstruction, urine leak or vesicoureteral reflux) as well as the position and patency of hepatic, biliary and renal drains and catheters. The aim of this review is to present current experience regarding the use of CEUS to evaluate liver and renal transplants, focusing on the examination technique and interpretation of the main imaging findings, predominantly those related to vascular complications.
- 19 February 2014
- Published by Springer Nature
- p. 415-432
Doppler Sonography of the Pancreas
- 19 February 2014
- Published by Springer Nature
- p. 311-377
Doppler Sonography of the Liver in Infants and Children
- 19 February 2014
- Published by Springer Nature
- p. 311-377
Doppler Sonography of the Liver in Infants and Children