Alexandros Rahn
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Alexandros Rahn has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Thomas Müller
Department of Pediatric Pulmonology, Allergology and Neonatology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany
5 shared publications Bettina Bohnhorst
Department of Pediatric Pulmonology, Allergology and Neonatology, Hannover Medical School, Hannover, Germany
4 shared publicationsDoris Franke
Hannover Medical School
4 shared publications- Sabine Pirr
Department of Pediatric Pneumology, Allergology and Neonatology, Hannover Medical School, Hannover, Germany
4 shared publications - Corinna Peter
Department of Pediatric Pulmonology, Allergology and Neonatology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany
3 shared publications - Doris Franke
Department of Pediatric Kidney, Liver and Metabolic Diseases, Hannover Medical School, Hannover, Germany
3 shared publications
Latest Publications
- Open Access
- 28 October 2026
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 185 (11) , 898
Organ size in small infants (The OSSI Study): are sonographic reference intervals applicable in preterm infants small for gestational age?
Sonographic reference intervals for liver, spleen, and kidney size in preterm infants below 40 cm body length were recently established in an appropriately grown (AGA) neonatal cohort. Whether these intervals apply to infants born small for gestational age (SGA) remains unexamined. In this cross-sectional study, 20 preterm SGA infants below 40 cm body length (mean gestational age 29 1 / 7 weeks, median birth weight 695 g) underwent standardized abdominal ultrasound, measuring craniocaudal liver length in three planes, splenic length, and renal volume. Measurements were compared with published reference intervals, and z-scores assessed systematic deviation. Weight and length at examination were comparable between the SGA and AGA cohorts. The mean z-score was significantly below zero only for liver length in the midclavicular line (− 0.79, p = 0.014). The proportion of infants outside the reference interval exceeded the expected 5% for liver length in the midclavicular line (25%, p = 0.003) and anterior axillary line (20%, p = 0.016) and for spleen length (20%, p = 0.016), but rested on 4 to 5 infants each, and several values lay within 1 mm of the limit. Kidney measurements did not differ from the reference. Organ size correlated most strongly with body weight, and the deviations persisted at equal weight (post hoc). Conclusion : Abdominal organ dimensions in SGA preterm infants frequently fall outside AGA-derived reference intervals, particularly for liver and spleen size, suggesting that these intervals cannot be reliably applied to this population. Prospective studies establishing reference values for SGA infants are warranted. What is Known: • Sonographic reference intervals for abdominal organ size in preterm infants below 40 cm exist only for appropriately grown (AGA) infants; their applicability to infants small for gestational age (SGA) has not been examined . What is New: • In 20 preterm SGA infants, the mean z-score for liver length (midclavicular line) was below the AGA reference, and liver and spleen lengths fell outside the intervals more often than the expected 5% (exploratory) . • AGA intervals should not be assumed to apply to SGA infants .
- 28 October 2026
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 185 (11) , 898
Open AccessOrgan size in small infants (The OSSI Study): are sonographic reference intervals applicable in preterm infants small for gestational age?
Sonographic reference intervals for liver, spleen, and kidney size in preterm infants below 40 cm body length were recently established in an appropriately grown (AGA) neonatal cohort. Whether these intervals apply to infants born small for gestational age (SGA) remains unexamined. In this cross-sectional study, 20 preterm SGA infants below 40 cm body length (mean gestational age 29 1 / 7 weeks, median birth weight 695 g) underwent standardized abdominal ultrasound, measuring craniocaudal liver length in three planes, splenic length, and renal volume. Measurements were compared with published reference intervals, and z-scores assessed systematic deviation. Weight and length at examination were comparable between the SGA and AGA cohorts. The mean z-score was significantly below zero only for liver length in the midclavicular line (− 0.79, p = 0.014). The proportion of infants outside the reference interval exceeded the expected 5% for liver length in the midclavicular line (25%, p = 0.003) and anterior axillary line (20%, p = 0.016) and for spleen length (20%, p = 0.016), but rested on 4 to 5 infants each, and several values lay within 1 mm of the limit. Kidney measurements did not differ from the reference. Organ size correlated most strongly with body weight, and the deviations persisted at equal weight (post hoc). Conclusion : Abdominal organ dimensions in SGA preterm infants frequently fall outside AGA-derived reference intervals, particularly for liver and spleen size, suggesting that these intervals cannot be reliably applied to this population. Prospective studies establishing reference values for SGA infants are warranted. What is Known: • Sonographic reference intervals for abdominal organ size in preterm infants below 40 cm exist only for appropriately grown (AGA) infants; their applicability to infants small for gestational age (SGA) has not been examined . What is New: • In 20 preterm SGA infants, the mean z-score for liver length (midclavicular line) was below the AGA reference, and liver and spleen lengths fell outside the intervals more often than the expected 5% (exploratory) . • AGA intervals should not be assumed to apply to SGA infants .
- Open Access
- 30 June 2026
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 185 (7)
Bubbles in the barely born—contrast-enhanced ultrasound in neonates: a single-center experience
To assess clinical value, safety, and applicability of contrast-enhanced ultrasound (CEUS) in neonates, focusing on bedside use in intensive care. This retrospective single-center study included 23 neonates undergoing intravenous CEUS between 2010 and 2024, including seven preterm infants. The liver ( n = 18) was the most frequently examined organ, followed by kidneys ( n = 2), brain ( n = 2), and adrenals ( n = 1). Findings were compared with MRI ( n = 10), CT ( n = 3), or biopsy ( n = 8), when available. In nine cases, CEUS findings were consistent with clinical course and treatment response only, without an independent reference standard. Among the 14 cases with available reference diagnostics, CEUS established the diagnosis first in ten (71.4%); histological confirmation was available in eight cases, with concordance in five (62.5%). 13 examinations (56.5%) were performed for bedside problem-solving in the neonatal intensive care unit, and no adverse events were observed. Conclusion : CEUS provided clinically relevant diagnostic information in neonates, including preterm and critically ill infants and was well tolerated. CEUS was particularly valuable in hepatic vascular tumors, where it could provide a definite diagnosis, enabled hemodynamic assessment, supported treatment decisions, and aided identification of potentially life-threatening complications. Bedside use enabled timely diagnosis without sedation, intubation, or patient transport, thereby supporting minimal handling. In selected cases, CEUS may reduce the need for cross-sectional imaging. Despite off-label use, our findings suggest a beneficial role for CEUS in neonatal imaging, predominantly for hepatic indications. What is Known: • Contrast-enhanced ultrasound (CEUS) is a radiation-free, bedside-compatible imaging technique with an established safety profile in pediatric patients. • Neonatal CEUS experience is limited to small case series, predominantly reporting cerebral applications. What is New: • CEUS was feasible and well tolerated in neonates including preterm infants, with no adverse events in 23 examinations. • CEUS yielded clinically relevant diagnostic information across a range of indications, primarily hepatic, encompassing both focal lesions and perfusion assessment, supporting clinical decision-making in neonatal care.
- 30 June 2026
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 185 (7)
Open AccessBubbles in the barely born—contrast-enhanced ultrasound in neonates: a single-center experience
To assess clinical value, safety, and applicability of contrast-enhanced ultrasound (CEUS) in neonates, focusing on bedside use in intensive care. This retrospective single-center study included 23 neonates undergoing intravenous CEUS between 2010 and 2024, including seven preterm infants. The liver ( n = 18) was the most frequently examined organ, followed by kidneys ( n = 2), brain ( n = 2), and adrenals ( n = 1). Findings were compared with MRI ( n = 10), CT ( n = 3), or biopsy ( n = 8), when available. In nine cases, CEUS findings were consistent with clinical course and treatment response only, without an independent reference standard. Among the 14 cases with available reference diagnostics, CEUS established the diagnosis first in ten (71.4%); histological confirmation was available in eight cases, with concordance in five (62.5%). 13 examinations (56.5%) were performed for bedside problem-solving in the neonatal intensive care unit, and no adverse events were observed. Conclusion : CEUS provided clinically relevant diagnostic information in neonates, including preterm and critically ill infants and was well tolerated. CEUS was particularly valuable in hepatic vascular tumors, where it could provide a definite diagnosis, enabled hemodynamic assessment, supported treatment decisions, and aided identification of potentially life-threatening complications. Bedside use enabled timely diagnosis without sedation, intubation, or patient transport, thereby supporting minimal handling. In selected cases, CEUS may reduce the need for cross-sectional imaging. Despite off-label use, our findings suggest a beneficial role for CEUS in neonatal imaging, predominantly for hepatic indications. What is Known: • Contrast-enhanced ultrasound (CEUS) is a radiation-free, bedside-compatible imaging technique with an established safety profile in pediatric patients. • Neonatal CEUS experience is limited to small case series, predominantly reporting cerebral applications. What is New: • CEUS was feasible and well tolerated in neonates including preterm infants, with no adverse events in 23 examinations. • CEUS yielded clinically relevant diagnostic information across a range of indications, primarily hepatic, encompassing both focal lesions and perfusion assessment, supporting clinical decision-making in neonatal care.
- Open Access
- 28 May 2026
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 185 (6)
Organ size in small infants (The OSSI Study): establishing sonographic reference intervals for abdominal organs in preterm infants
Accurate ultrasound assessment of abdominal organ size in preterm infants is essential for evaluating growth and detecting abnormalities. However, standardized reference intervals for liver, spleen, and kidney dimensions in preterms below 40 cm body length are lacking. This study aimed to establish reference intervals for these organs. 57 eutrophic preterm infants with a body length below 40 cm (gestational age: 23 4 / 7 —31 5 / 7 weeks; birth length: 29—39.5 cm) were prospectively examined using a standardized ultrasound protocol recommended by the German Society for Ultrasound in Medicine (DEGUM). Craniocaudal liver length, spleen length, and renal volume were measured and correlated with corrected gestational age, body weight, and body length. Reference intervals were calculated from log-transformed data with 95% confidence intervals for reference limits. Portal vein peak velocity before feeding and presence of a patent ductus venosus (PDV) were additionally assessed. Organ dimensions correlated most closely with body weight, followed by body length and corrected gestational age, with renal volume showing the highest correlations overall. Reference intervals for liver, spleen, and renal size showed tight 95% confidence intervals. Portal vein peak velocity ranged from 9—29 cm/s. A PDV was present in 56%; these infants were younger at examination (10.9 vs. 17 days, p = 0.01). Conclusion : This study provides clinically relevant ultrasound reference intervals for abdominal organs in small preterm infants. These measurements may help distinguish physiological from pathological findings and guide clinical decision-making in neonatal care. What is Known: • Ultrasound is the preferred imaging modality for abdominal organ assessment in preterm infants, but standardized sonographic reference intervals for infants with a body length below 40 cm are lacking. What is New: • This study provides the first standardized sonographic reference intervals for liver length, splenic length, and renal volume in preterm infants below 40 cm body length, using a prospective, reproducible protocol aligned with DEGUM recommendations. • Organ size correlated most strongly with body weight, followed by body length and corrected gestational age, with renal volume showing the highest overall correlations across all parameters.
- 28 May 2026
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 185 (6)
Open AccessOrgan size in small infants (The OSSI Study): establishing sonographic reference intervals for abdominal organs in preterm infants
Accurate ultrasound assessment of abdominal organ size in preterm infants is essential for evaluating growth and detecting abnormalities. However, standardized reference intervals for liver, spleen, and kidney dimensions in preterms below 40 cm body length are lacking. This study aimed to establish reference intervals for these organs. 57 eutrophic preterm infants with a body length below 40 cm (gestational age: 23 4 / 7 —31 5 / 7 weeks; birth length: 29—39.5 cm) were prospectively examined using a standardized ultrasound protocol recommended by the German Society for Ultrasound in Medicine (DEGUM). Craniocaudal liver length, spleen length, and renal volume were measured and correlated with corrected gestational age, body weight, and body length. Reference intervals were calculated from log-transformed data with 95% confidence intervals for reference limits. Portal vein peak velocity before feeding and presence of a patent ductus venosus (PDV) were additionally assessed. Organ dimensions correlated most closely with body weight, followed by body length and corrected gestational age, with renal volume showing the highest correlations overall. Reference intervals for liver, spleen, and renal size showed tight 95% confidence intervals. Portal vein peak velocity ranged from 9—29 cm/s. A PDV was present in 56%; these infants were younger at examination (10.9 vs. 17 days, p = 0.01). Conclusion : This study provides clinically relevant ultrasound reference intervals for abdominal organs in small preterm infants. These measurements may help distinguish physiological from pathological findings and guide clinical decision-making in neonatal care. What is Known: • Ultrasound is the preferred imaging modality for abdominal organ assessment in preterm infants, but standardized sonographic reference intervals for infants with a body length below 40 cm are lacking. What is New: • This study provides the first standardized sonographic reference intervals for liver length, splenic length, and renal volume in preterm infants below 40 cm body length, using a prospective, reproducible protocol aligned with DEGUM recommendations. • Organ size correlated most strongly with body weight, followed by body length and corrected gestational age, with renal volume showing the highest overall correlations across all parameters.
- Open Access
- 18 May 2026
- Published by Wiley in Acta Paediatrica
- Vol. 115 (9) , 1982-1990
Doxapram Exposure Was Not Associated With Adverse Neurodevelopmental Outcomes in Very Low Birth Weight Infants: A Monocentric Retrospective Cohort Study
Aim: Doxapram is used as an additional therapy for apnea of prematurity when standard treatments such as caffeine or continuous positive airway pressure are insufficient, but its impact on long‐term neurodevelopment remains uncertain. This study evaluated the association between Doxapram exposure and neurodevelopmental outcomes in very low birth weight infants (VLBWI), with a focus on potential dose‐dependent effects. Methods: In this monocentric retrospective cohort study, VLBWI with gestational age ≤ 32 weeks were included. Infants treated with Doxapram ( n = 140) were compared to untreated controls ( n = 280) matched by year of birth. Exposure was stratified by cumulative dose. The primary outcome was neurodevelopment at 24 months corrected age assessed by the mental development index or global development quotient (MDI/GDQ). Secondary outcomes included mortality, growth parameters and neurological outcomes. Multivariable logistic regression adjusted for confounders. Results: Neurodevelopment did not differ between groups (MDI/GDQ: 94.2 ± 21.2 vs. 97.7 ± 14.8; p = 0.1), nor did mortality (5.0% vs. 6.8%; p = 0.53). No dose‐dependent associations were observed. Secondary outcomes were comparable. Conclusions: Doxapram exposure was not associated with adverse neurodevelopmental outcomes in VLBWI within the investigated dosage range, although definitive conclusions on drug safety cannot be drawn from medium‐sized cohorts and confirmation in prospective randomised studies is required.
- 18 May 2026
- Published by Wiley in Acta Paediatrica
- Vol. 115 (9) , 1982-1990
Open AccessDoxapram Exposure Was Not Associated With Adverse Neurodevelopmental Outcomes in Very Low Birth Weight Infants: A Monocentric Retrospective Cohort Study
Aim: Doxapram is used as an additional therapy for apnea of prematurity when standard treatments such as caffeine or continuous positive airway pressure are insufficient, but its impact on long‐term neurodevelopment remains uncertain. This study evaluated the association between Doxapram exposure and neurodevelopmental outcomes in very low birth weight infants (VLBWI), with a focus on potential dose‐dependent effects. Methods: In this monocentric retrospective cohort study, VLBWI with gestational age ≤ 32 weeks were included. Infants treated with Doxapram ( n = 140) were compared to untreated controls ( n = 280) matched by year of birth. Exposure was stratified by cumulative dose. The primary outcome was neurodevelopment at 24 months corrected age assessed by the mental development index or global development quotient (MDI/GDQ). Secondary outcomes included mortality, growth parameters and neurological outcomes. Multivariable logistic regression adjusted for confounders. Results: Neurodevelopment did not differ between groups (MDI/GDQ: 94.2 ± 21.2 vs. 97.7 ± 14.8; p = 0.1), nor did mortality (5.0% vs. 6.8%; p = 0.53). No dose‐dependent associations were observed. Secondary outcomes were comparable. Conclusions: Doxapram exposure was not associated with adverse neurodevelopmental outcomes in VLBWI within the investigated dosage range, although definitive conclusions on drug safety cannot be drawn from medium‐sized cohorts and confirmation in prospective randomised studies is required.
- 23 April 2026
- Published by Wolters Kluwer Health in Journal of Perinatal & Neonatal Nursing
Perceptions of Psychological Safety Among Health Care Professionals in a Level III Neonatal Intensive Care Unit: An Interprofessional Survey
Purpose: To assess perceptions of psychological safety (PS) among nurses and physicians in a Level III neonatal intensive care unit (NICU) and its association with organizational factors and intention to leave. Background: PS supports teamwork, open communication, patient safety, and staff well-being, yet evidence from NICUs and its relevance for workforce retention remains limited. Methods: An exploratory cross-sectional survey was conducted between August and September 2025 in a Level III NICU of a German university hospital. Nurses and physicians completed an anonymous online, pretested questionnaire based on validated items. The questionnaire comprised 31 items assessing PS, teamwork, communication, workload, and error management, rated on a six-point Likert scale. Data were analyzed descriptively, including subgroup comparisons by profession, age, experience, and intention to leave. Results: Overall, 101 health care professionals participated (response rate 89%). Respondents described a respectful and supportive team climate with strong commitment to patient safety. However, challenges were identified in speaking up, conflict resolution, onboarding, and error communication. More than half reported stress-related impairment at work and consideration of leaving the profession within the past year. Physicians rated PS more positively than nurses, while participants with turnover intention reported substantially lower PS. Conclusion: PS in the NICU was perceived as positive, but vulnerabilities persist regarding communication, inclusivity, and error management culture. Lower PS was associated with intention to leave, underscoring its relevance for workforce retention. Implications for practice and research: Onboarding, inclusive leadership, feedback, and forums for discussing errors are recommended. Longitudinal studies should examine staff well-being and retention.
- 23 April 2026
- Published by Wolters Kluwer Health in Journal of Perinatal & Neonatal Nursing
Perceptions of Psychological Safety Among Health Care Professionals in a Level III Neonatal Intensive Care Unit: An Interprofessional Survey
Purpose: To assess perceptions of psychological safety (PS) among nurses and physicians in a Level III neonatal intensive care unit (NICU) and its association with organizational factors and intention to leave. Background: PS supports teamwork, open communication, patient safety, and staff well-being, yet evidence from NICUs and its relevance for workforce retention remains limited. Methods: An exploratory cross-sectional survey was conducted between August and September 2025 in a Level III NICU of a German university hospital. Nurses and physicians completed an anonymous online, pretested questionnaire based on validated items. The questionnaire comprised 31 items assessing PS, teamwork, communication, workload, and error management, rated on a six-point Likert scale. Data were analyzed descriptively, including subgroup comparisons by profession, age, experience, and intention to leave. Results: Overall, 101 health care professionals participated (response rate 89%). Respondents described a respectful and supportive team climate with strong commitment to patient safety. However, challenges were identified in speaking up, conflict resolution, onboarding, and error communication. More than half reported stress-related impairment at work and consideration of leaving the profession within the past year. Physicians rated PS more positively than nurses, while participants with turnover intention reported substantially lower PS. Conclusion: PS in the NICU was perceived as positive, but vulnerabilities persist regarding communication, inclusivity, and error management culture. Lower PS was associated with intention to leave, underscoring its relevance for workforce retention. Implications for practice and research: Onboarding, inclusive leadership, feedback, and forums for discussing errors are recommended. Longitudinal studies should examine staff well-being and retention.
- Open Access
- 10 February 2026
- Published by Springer Nature in BMC Pediatrics
- Vol. 26 (1)
Missing data, missed risks: complications and documentation gaps of central venous access devices in pediatric oncology
Background: Central venous access devices (CVADs) are essential in pediatric oncology but frequently associated with infections, thromboses, and dysfunction. Although structured surveillance may reduce complications, implementation is limited by fragmented documentation across clinical systems. Methods: We conducted a mixed-methods study combining a two-stage interdisciplinary electronic Delphi process with retrospective cohort analysis. Pediatric oncology patients diagnosed between 2020 and 2021 who received a CVAD at our university hospital were included. Data were manually extracted from three hospital information systems. Only the first CVAD per patient was analyzed ( n = 112). Results: Of 219 diagnosed patients, 112 met inclusion criteria, accounting for 126 CVADs. The eDelphi panel identified 30 core surveillance parameters, 23 retrievable from routine records. Complications occurred in 23.2%, most commonly infections leading to premature removal. Conclusions: Standardized electronic CVAD documentation could enhance surveillance, improve patient safety, and reduce manual data collection efforts.
- 10 February 2026
- Published by Springer Nature in BMC Pediatrics
- Vol. 26 (1)
Open AccessMissing data, missed risks: complications and documentation gaps of central venous access devices in pediatric oncology
Background: Central venous access devices (CVADs) are essential in pediatric oncology but frequently associated with infections, thromboses, and dysfunction. Although structured surveillance may reduce complications, implementation is limited by fragmented documentation across clinical systems. Methods: We conducted a mixed-methods study combining a two-stage interdisciplinary electronic Delphi process with retrospective cohort analysis. Pediatric oncology patients diagnosed between 2020 and 2021 who received a CVAD at our university hospital were included. Data were manually extracted from three hospital information systems. Only the first CVAD per patient was analyzed ( n = 112). Results: Of 219 diagnosed patients, 112 met inclusion criteria, accounting for 126 CVADs. The eDelphi panel identified 30 core surveillance parameters, 23 retrievable from routine records. Complications occurred in 23.2%, most commonly infections leading to premature removal. Conclusions: Standardized electronic CVAD documentation could enhance surveillance, improve patient safety, and reduce manual data collection efforts.
- Open Access
- 16 January 2026
- Published by Wiley in Pediatric Blood & Cancer
- Vol. 73 (4) , e70144
Psychological Safety Among Interprofessional Pediatric Oncology Teams in Germany: A Nationwide Survey
Background: Psychological safety (PS) is essential for teamwork, communication, and patient safety in complex healthcare environments. In pediatric oncology, interprofessional collaboration occurs under high emotional and organizational demands. Low PS may increase stress, burnout, and adverse events. To assess PS in pediatric oncology teams across Germany, a survey including items on communication, workload, and error management culture was conducted among members of the “Gesellschaft für Paediatrische Onkologie und Haematologie” (GPOH, Society for Pediatric Oncology and Hematology). Procedure: In October 2025, healthcare professionals from GPOH member institutions completed an online survey on PS. The 38‐item questionnaire addressed PS and related aspects like communication, teamwork, leadership, workload, error management, and team climate. Responses were rated on a six‐point Likert scale and analyzed descriptively and by subgroups. Results: A total of 273 professionals completed the survey (Cronbach's α = 0.89). Teams reported a respectful, safety‐oriented climate but noted challenges with workload, onboarding, and feedback. Only two‐thirds indicated that mistakes in patient care were discussed openly. Physicians reported more open communication and constructive problem handling, while nurses experienced greater stress and more dismissive behavior toward “different” colleagues. Leaders showed higher PS, whereas lower PS across all domains was observed among participants who had seriously considered changing their jobs. Job satisfaction closely correlated with PS, particularly with open communication, trust, and respect. Conclusions: The findings emphasize that PS is both essential and improvable in pediatric oncology teams; strengthening leadership, feedback, and interprofessional reflection may enhance staff well‐being, retention, and patient safety across this high‐stakes field.
- 16 January 2026
- Published by Wiley in Pediatric Blood & Cancer
- Vol. 73 (4) , e70144
Open AccessPsychological Safety Among Interprofessional Pediatric Oncology Teams in Germany: A Nationwide Survey
Background: Psychological safety (PS) is essential for teamwork, communication, and patient safety in complex healthcare environments. In pediatric oncology, interprofessional collaboration occurs under high emotional and organizational demands. Low PS may increase stress, burnout, and adverse events. To assess PS in pediatric oncology teams across Germany, a survey including items on communication, workload, and error management culture was conducted among members of the “Gesellschaft für Paediatrische Onkologie und Haematologie” (GPOH, Society for Pediatric Oncology and Hematology). Procedure: In October 2025, healthcare professionals from GPOH member institutions completed an online survey on PS. The 38‐item questionnaire addressed PS and related aspects like communication, teamwork, leadership, workload, error management, and team climate. Responses were rated on a six‐point Likert scale and analyzed descriptively and by subgroups. Results: A total of 273 professionals completed the survey (Cronbach's α = 0.89). Teams reported a respectful, safety‐oriented climate but noted challenges with workload, onboarding, and feedback. Only two‐thirds indicated that mistakes in patient care were discussed openly. Physicians reported more open communication and constructive problem handling, while nurses experienced greater stress and more dismissive behavior toward “different” colleagues. Leaders showed higher PS, whereas lower PS across all domains was observed among participants who had seriously considered changing their jobs. Job satisfaction closely correlated with PS, particularly with open communication, trust, and respect. Conclusions: The findings emphasize that PS is both essential and improvable in pediatric oncology teams; strengthening leadership, feedback, and interprofessional reflection may enhance staff well‐being, retention, and patient safety across this high‐stakes field.
- Open Access
- 7 January 2026
- Published by Springer Nature in Maternal Health, Neonatology and Perinatology
- Vol. 12 (1) , 1
Stuck in transition - admission to the neonatal intensive care unit after shoulder dystocia: analysis of risk factors and assessment of postnatal care
Background: This study aimed to assess frequency and causes of neonatal intensive care unit (NICU) admissions in neonates with shoulder dystocia (SD). Methods: A retrospective analysis of 116 SD cases at a tertiary perinatal center was performed (2007 – 2023). Maternal and neonatal parameters were evaluated in relation to NICU admission. Results: Seventeen neonates (14.7%) were admitted to the NICU. All showed respiratory distress; five required cardiopulmonary resuscitation, two of them received therapeutic hypothermia for hypoxic-ischemic encephalopathy. Compared to non-admitted infants, NICU neonates had significantly lower umbilical artery pH and base deficit, lower Apgar scores, and higher rate of birth injuries. They also had a significantly longer median head-to-body delivery interval (HBDI, 5.0 vs. 2.0 minutes, p < 0.0001). No neonatal deaths occurred before discharge. Conclusion: SD can lead to severe postnatal adaptation problems in newborns, requiring timely and structured interdisciplinary management. Our findings suggest that a HBDI of ≥ five minutes serve as a clinically applicable parameter to identify neonates at increased risk of NICU admission and appears to be associated with a higher likelihood of brachial plexus injury. Furthermore, greater fetal size, reflected by higher birth weight and body surface area, was related to the occurrence of birth injuries overall, underscoring the relevance of both extraction time and fetal dimensions for postnatal outcomes after SD.
- 7 January 2026
- Published by Springer Nature in Maternal Health, Neonatology and Perinatology
- Vol. 12 (1) , 1
Open AccessStuck in transition - admission to the neonatal intensive care unit after shoulder dystocia: analysis of risk factors and assessment of postnatal care
Background: This study aimed to assess frequency and causes of neonatal intensive care unit (NICU) admissions in neonates with shoulder dystocia (SD). Methods: A retrospective analysis of 116 SD cases at a tertiary perinatal center was performed (2007 – 2023). Maternal and neonatal parameters were evaluated in relation to NICU admission. Results: Seventeen neonates (14.7%) were admitted to the NICU. All showed respiratory distress; five required cardiopulmonary resuscitation, two of them received therapeutic hypothermia for hypoxic-ischemic encephalopathy. Compared to non-admitted infants, NICU neonates had significantly lower umbilical artery pH and base deficit, lower Apgar scores, and higher rate of birth injuries. They also had a significantly longer median head-to-body delivery interval (HBDI, 5.0 vs. 2.0 minutes, p < 0.0001). No neonatal deaths occurred before discharge. Conclusion: SD can lead to severe postnatal adaptation problems in newborns, requiring timely and structured interdisciplinary management. Our findings suggest that a HBDI of ≥ five minutes serve as a clinically applicable parameter to identify neonates at increased risk of NICU admission and appears to be associated with a higher likelihood of brachial plexus injury. Furthermore, greater fetal size, reflected by higher birth weight and body surface area, was related to the occurrence of birth injuries overall, underscoring the relevance of both extraction time and fetal dimensions for postnatal outcomes after SD.
- Open Access
- 25 September 2025
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 35 (10) , 2016-2023
Tiny clots, big choices: intervening on neonatal aortic thrombosis—a novel framework for clinical decision-making
Background: Neonatal aortic thrombosis, though rare, is a critical condition with high morbidity and mortality. Spontaneous thrombosis is uncommon, complicating diagnosis due to its similarity to aortic coarctation. Standard treatments include heparinisation and thrombolysis, but severe cases may require interventional or surgical thrombectomy. Aim: This case series examines interventional therapy in neonates with spontaneous aortic thrombosis, focusing on reduced systolic function or organ failure, and evaluates off-label thrombectomy devices. Method: Three neonates with spontaneous abdominal aortic thrombosis treated at Hannover Medical School between 2017 and 2023 were reviewed. Clinical presentation, diagnostics, treatments, and outcomes were analysed. Treatment involved therapeutic anticoagulation, systemic thrombolysis and interventional thrombectomy using off-label devices. A literature review on interventional thrombectomy in neonates was conducted. Results: The first neonate, with severe multi-organ failure, died after thrombectomy. The second recovered fully with systemic thrombolysis. The third, critically ill, recovered following successful thrombectomy and thrombolysis. Off-label use of the Amplatzer Vascular Plug II proved more effective than the Amplatzer Piccolo PDA Occluder for managing organised thrombus. A literature review identified seven cases of neonatal aortic thrombectomy using various devices, highlighting interventional thrombectomy as a promising treatment for neonates with cardiac decompensation or imminent organ failure. Conclusion: We propose a diagnostic approach for newborns with diminished or absent femoral pulses without structural heart or vascular disease. Interventional thrombectomy is a viable option for neonates with spontaneous aortic thrombosis in life-threatening situations involving decreased systolic function or organ failure. Further studies are needed to evaluate safety and long-term outcomes of catheter-based interventions.
- 25 September 2025
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 35 (10) , 2016-2023
Open AccessTiny clots, big choices: intervening on neonatal aortic thrombosis—a novel framework for clinical decision-making
Background: Neonatal aortic thrombosis, though rare, is a critical condition with high morbidity and mortality. Spontaneous thrombosis is uncommon, complicating diagnosis due to its similarity to aortic coarctation. Standard treatments include heparinisation and thrombolysis, but severe cases may require interventional or surgical thrombectomy. Aim: This case series examines interventional therapy in neonates with spontaneous aortic thrombosis, focusing on reduced systolic function or organ failure, and evaluates off-label thrombectomy devices. Method: Three neonates with spontaneous abdominal aortic thrombosis treated at Hannover Medical School between 2017 and 2023 were reviewed. Clinical presentation, diagnostics, treatments, and outcomes were analysed. Treatment involved therapeutic anticoagulation, systemic thrombolysis and interventional thrombectomy using off-label devices. A literature review on interventional thrombectomy in neonates was conducted. Results: The first neonate, with severe multi-organ failure, died after thrombectomy. The second recovered fully with systemic thrombolysis. The third, critically ill, recovered following successful thrombectomy and thrombolysis. Off-label use of the Amplatzer Vascular Plug II proved more effective than the Amplatzer Piccolo PDA Occluder for managing organised thrombus. A literature review identified seven cases of neonatal aortic thrombectomy using various devices, highlighting interventional thrombectomy as a promising treatment for neonates with cardiac decompensation or imminent organ failure. Conclusion: We propose a diagnostic approach for newborns with diminished or absent femoral pulses without structural heart or vascular disease. Interventional thrombectomy is a viable option for neonates with spontaneous aortic thrombosis in life-threatening situations involving decreased systolic function or organ failure. Further studies are needed to evaluate safety and long-term outcomes of catheter-based interventions.
- Open Access
- 1 August 2025
- Published by SAGE Publications in Journal of Neonatology
- Vol. 39 (6) , 538-546
Tiny Torsos, Tight Consensus: A Prospective Interobserver Study on Abdominal Ultrasound in Preterm Infants
Background: Accurate organ measurement is essential in neonatal ultrasound in order to guide clinical decisions. However, interobserver variability remains a challenge, especially in preterm infants, where small organ dimensions and technical limitations can affect reproducibility. Consistent agreement between examiners is crucial to ensure reliable and standardized assessments. This prospective observational study evaluates interobserver agreement in ultrasound measurements of the liver, kidney, and spleen in preterm infants. Methods: In this prospective observational study, a total of 74 ultrasound examinations were performed in 30 preterm infants, with seven infants being measured twice. The 37 paired assessments included independent measurements of the liver (midsternal line (MSL), midclavicular line (MCL), and anterior axillary line (AAL)), kidneys, and spleen by two experienced examiners. Statistical analyses included the Wilcoxon matched-pairs signed rank test, paired t -test, Pearson correlation coefficient (PCC), intraclass correlation coefficient (ICC), and Bland–Altman analysis. Results: No significant differences were found between examiners ( P > .05), except for the generally least reproducible liver length in the MCL. PCC and ICC values for all measurements exceeded 0.929, indicating excellent interobserver agreement. Conclusion: Ultrasound investigations remain a reliable and reproducible tool for organ size assessment in neonatal care, even in extremely low birth weight infants with tiny anatomical structures. The strong interobserver agreement emphasizes the importance of standardized measurement protocols and ultrasound training, ensuring consistency in clinical practice.
- 1 August 2025
- Published by SAGE Publications in Journal of Neonatology
- Vol. 39 (6) , 538-546
Open AccessTiny Torsos, Tight Consensus: A Prospective Interobserver Study on Abdominal Ultrasound in Preterm Infants
Background: Accurate organ measurement is essential in neonatal ultrasound in order to guide clinical decisions. However, interobserver variability remains a challenge, especially in preterm infants, where small organ dimensions and technical limitations can affect reproducibility. Consistent agreement between examiners is crucial to ensure reliable and standardized assessments. This prospective observational study evaluates interobserver agreement in ultrasound measurements of the liver, kidney, and spleen in preterm infants. Methods: In this prospective observational study, a total of 74 ultrasound examinations were performed in 30 preterm infants, with seven infants being measured twice. The 37 paired assessments included independent measurements of the liver (midsternal line (MSL), midclavicular line (MCL), and anterior axillary line (AAL)), kidneys, and spleen by two experienced examiners. Statistical analyses included the Wilcoxon matched-pairs signed rank test, paired t -test, Pearson correlation coefficient (PCC), intraclass correlation coefficient (ICC), and Bland–Altman analysis. Results: No significant differences were found between examiners ( P > .05), except for the generally least reproducible liver length in the MCL. PCC and ICC values for all measurements exceeded 0.929, indicating excellent interobserver agreement. Conclusion: Ultrasound investigations remain a reliable and reproducible tool for organ size assessment in neonatal care, even in extremely low birth weight infants with tiny anatomical structures. The strong interobserver agreement emphasizes the importance of standardized measurement protocols and ultrasound training, ensuring consistency in clinical practice.