Ming Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ming Yang has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Hidekazu Yoshikawa
Foundational Science on Nuclear Safety and Simulation Laboratory, College of Nuclear Science and Technology, Harbin Engineering University, Harbin, China
5 shared publications- Zhanguo Ma
Foundational Science on Nuclear Safety and Simulation Laboratory, College of Nuclear Science and Technology, Harbin Engineering University, Harbin, China
3 shared publications - Gang Liu
School of Electric Power Engineering, South China University of Technology, Guangzhou 510640, China
2 shared publications - Hidekazu Yoshikawa
Symbio Community Forum, Kyoto, Japan
2 shared publications Amjad Nawaz
Foundational Science on Nuclear Safety and Simulation Laboratory, College of Nuclear Science and Technology, Harbin Engineering University, Harbin, China
1 shared publication- Amjad Nawaz
College of Nuclear Science and Technology, Harbin Engineering University, Harbin, China
1 shared publication
Latest Publications
- Open Access
Influence of Combined Electrothermal Aging on Dielectric and Thermal Properties of HVAC XLPE Cable
To explore the influence of electrothermal aging on the properties of HVAC XLPE cable during its normal operation, two circuits of 110 kV XLPE cable were subjected to a combined electrothermal accelerated aging test for 180 days. The test voltage was set at 95 kV, and the test temperature was set at 90 °C. The constant temperature aging mode was adopted for one circuit, and the periodic thermal cycle aging mode was adopted for the other circuit. The dielectric property of the cable was diagnosed with dielectric spectroscopy measurement, and the thermal property was diagnosed with thermal parameters (thermal capacity and thermal resistance) measurement. Combined with Fourier infrared spectroscopy (FTIR) and differential scanning calorimetry (DSC) measurements, morphological changes in the insulation under different electrothermal aging modes were analyzed to construct the correlation with the dielectric and thermal properties. The results show that the short-term electrothermal constant temperature aging mode effectively enhances the dielectric and thermal properties of the cable by modifying spherulite morphology and migrating polar compounds; the short-term electrothermal cycle aging mode also enhances the thermal properties of the cable due to the drop in small polar compounds. However, different distributions of polar compounds and crystal interfaces in the insulation lead to extreme distortion in the electric field distribution.
Open AccessInfluence of Combined Electrothermal Aging on Dielectric and Thermal Properties of HVAC XLPE Cable
To explore the influence of electrothermal aging on the properties of HVAC XLPE cable during its normal operation, two circuits of 110 kV XLPE cable were subjected to a combined electrothermal accelerated aging test for 180 days. The test voltage was set at 95 kV, and the test temperature was set at 90 °C. The constant temperature aging mode was adopted for one circuit, and the periodic thermal cycle aging mode was adopted for the other circuit. The dielectric property of the cable was diagnosed with dielectric spectroscopy measurement, and the thermal property was diagnosed with thermal parameters (thermal capacity and thermal resistance) measurement. Combined with Fourier infrared spectroscopy (FTIR) and differential scanning calorimetry (DSC) measurements, morphological changes in the insulation under different electrothermal aging modes were analyzed to construct the correlation with the dielectric and thermal properties. The results show that the short-term electrothermal constant temperature aging mode effectively enhances the dielectric and thermal properties of the cable by modifying spherulite morphology and migrating polar compounds; the short-term electrothermal cycle aging mode also enhances the thermal properties of the cable due to the drop in small polar compounds. However, different distributions of polar compounds and crystal interfaces in the insulation lead to extreme distortion in the electric field distribution.
- Open Access
- 10 December 2022
- Published by Wiley
Influence of Combined Electrothermal Aging on Dielectric and Thermal Properties of HVAC XLPE Cable
To explore the influence of electrothermal aging on the properties of HVAC XLPE cable during its actual operation, two circuits of 110 kV XLPE cable were subjected to a combined electrothermal accelerated aging test for 180 days. The test voltage was set at 95 kV and the test temperature was set at 90 ℃. One circuit of cable adopted constant temperature aging mode and the other circuit adopted periodic thermal cycle aging mode. The dielectric property of the cable is diagnosed by dielectric spectroscopy measurement, and the thermal property is diagnosed by thermal parameters measurement. Combined with Fourier infrared spectroscopy (FTIR) and differential scanning calorimetry (DSC) measurements, morphological changes of the insulation under different electrothermal aging modes are analyzed to construct the correlation with the dielectric and thermal properties. The results show that short-term electrothermal constant temperature aging mode effectively enhances the dielectric and thermal properties of the cable by modifying spherulites’ morphology and migrating small polar compounds; short-term electrothermal cycle aging mode also enhances the thermal properties of the cable due to the drop in small polar compounds. However, different distributions of small polar compounds and crystal interfaces in the insulation lead to extreme distortion in electric field distribution.
- 10 December 2022
- Published by Wiley
Open AccessInfluence of Combined Electrothermal Aging on Dielectric and Thermal Properties of HVAC XLPE Cable
To explore the influence of electrothermal aging on the properties of HVAC XLPE cable during its actual operation, two circuits of 110 kV XLPE cable were subjected to a combined electrothermal accelerated aging test for 180 days. The test voltage was set at 95 kV and the test temperature was set at 90 ℃. One circuit of cable adopted constant temperature aging mode and the other circuit adopted periodic thermal cycle aging mode. The dielectric property of the cable is diagnosed by dielectric spectroscopy measurement, and the thermal property is diagnosed by thermal parameters measurement. Combined with Fourier infrared spectroscopy (FTIR) and differential scanning calorimetry (DSC) measurements, morphological changes of the insulation under different electrothermal aging modes are analyzed to construct the correlation with the dielectric and thermal properties. The results show that short-term electrothermal constant temperature aging mode effectively enhances the dielectric and thermal properties of the cable by modifying spherulites’ morphology and migrating small polar compounds; short-term electrothermal cycle aging mode also enhances the thermal properties of the cable due to the drop in small polar compounds. However, different distributions of small polar compounds and crystal interfaces in the insulation lead to extreme distortion in electric field distribution.
- 11 October 2018
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 51 (24) , 1364-1367
Integrated Defense-in Depth (DiD) Risk Analysis System for Safety Operation of Nuclear Power Plants
- 11 October 2018
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 51 (24) , 1364-1367
Integrated Defense-in Depth (DiD) Risk Analysis System for Safety Operation of Nuclear Power Plants
- 26 December 2017
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 55 (5) , 516-529
A human–machine interaction design and evaluation method by combination of scenario simulation and knowledge base
A method of designing and evaluating HMI (human–machine interaction) is proposed for the design in supervisory control of fully digitalized I&C (instrumentation and control) and digitalized human–machine interface system, which is a large-scale complex system in the NPPs (nuclear power plants). The proposed method consists of plant accident scenario simulation, knowledge base establishment, and interaction simulation. The plant accident scenario simulation is to analyze the plant behavior and system sequences under the predefined conditions; the knowledge base is modeled based on the simulation results as human and machine roles; and the interaction simulation is to simulate the interactions such as between operator and plant, operator and technical advisor. The proposed method utilizes the object-oriented software named plant DiD (defense-in-depth) risk monitor with the combination of accident simulation by an advanced nuclear safety analysis code such as RELAP5/MOD4. The practical developments for the details are demonstrated using an example practice for the SBLOCA (small break loss of coolant accident) case of passive safety PWR (pressurized water reactor) AP1000.
- 26 December 2017
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 55 (5) , 516-529
A human–machine interaction design and evaluation method by combination of scenario simulation and knowledge base
A method of designing and evaluating HMI (human–machine interaction) is proposed for the design in supervisory control of fully digitalized I&C (instrumentation and control) and digitalized human–machine interface system, which is a large-scale complex system in the NPPs (nuclear power plants). The proposed method consists of plant accident scenario simulation, knowledge base establishment, and interaction simulation. The plant accident scenario simulation is to analyze the plant behavior and system sequences under the predefined conditions; the knowledge base is modeled based on the simulation results as human and machine roles; and the interaction simulation is to simulate the interactions such as between operator and plant, operator and technical advisor. The proposed method utilizes the object-oriented software named plant DiD (defense-in-depth) risk monitor with the combination of accident simulation by an advanced nuclear safety analysis code such as RELAP5/MOD4. The practical developments for the details are demonstrated using an example practice for the SBLOCA (small break loss of coolant accident) case of passive safety PWR (pressurized water reactor) AP1000.
- 1 March 2017
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 54 (5) , 539-551
Reliability model of the digital reactor protection system considering the repair time and common cause failure
Reliability of the digital reactor protection system (RPS) is intensively researched as it is designed and installed to ensure the safety and economy which can be measured respectively by the probability of failure on demand (PFD) and probability of spurious trip (PST). Meanwhile, by analyzing the failure modes of the digital RPS, the failure on demand and spurious trip are the two main modes that should be evaluated for the reliability of digital RPS. Therefore, this paper develops the PFD and PST calculation formulas considering the module repair time as the repair takes some time, and during the repair duration, the digital system is operated in the degraded configuration and the common cause failure (CCF) which would severely impact the system in the event of occurrence. Considering the failure phenomenon of the digital RPS, the binomial failure rate (BFR) model is adopted for CCF. And the fault-tolerance techniques and their fault coverage are considered when calculating the PFD and PST. The quantitative results show that, in the example, CCF dominates the PFD while CCF is one of the major factors that result in PST but the main contributor is the independent failure. Also it can be concluded that the discovery time for the undetected failures dominates the PFD and PST when it costs long time to discover the failures even though the uncovered failures are very few. Thus, the failures should be covered by the fault-tolerance techniques as much as possible when designing the digital RPS.
- 1 March 2017
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 54 (5) , 539-551
Reliability model of the digital reactor protection system considering the repair time and common cause failure
Reliability of the digital reactor protection system (RPS) is intensively researched as it is designed and installed to ensure the safety and economy which can be measured respectively by the probability of failure on demand (PFD) and probability of spurious trip (PST). Meanwhile, by analyzing the failure modes of the digital RPS, the failure on demand and spurious trip are the two main modes that should be evaluated for the reliability of digital RPS. Therefore, this paper develops the PFD and PST calculation formulas considering the module repair time as the repair takes some time, and during the repair duration, the digital system is operated in the degraded configuration and the common cause failure (CCF) which would severely impact the system in the event of occurrence. Considering the failure phenomenon of the digital RPS, the binomial failure rate (BFR) model is adopted for CCF. And the fault-tolerance techniques and their fault coverage are considered when calculating the PFD and PST. The quantitative results show that, in the example, CCF dominates the PFD while CCF is one of the major factors that result in PST but the main contributor is the independent failure. Also it can be concluded that the discovery time for the undetected failures dominates the PFD and PST when it costs long time to discover the failures even though the uncovered failures are very few. Thus, the failures should be covered by the fault-tolerance techniques as much as possible when designing the digital RPS.
- 23 February 2017
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 54 (5) , 552-568
Knowledge-based software design for Defense-in-Depth risk monitor system and application for AP1000
As part of the new risk monitor system, the software for the plant Defense-in-Depth (DiD) risk monitor system was designed based on the state-transition and finite-state machine, and then the knowledge-based software was developed by object-oriented method utilizing the Unified Modeling Language (UML). Currently, there are mainly two functions in the developed plant DiD risk monitor software that are knowledge-base editor which is used to model the system in a hierarchical manner and the interaction simulator that simulates the interactions between the different actors in the model. In this paper, a model for playing its behavior is called an Actor which is modeled at the top level. The passive safety AP1000 power plant was studied and the small-break loss-of-coolant accident (SBLOCA) design basis accident transient is modeled using the plant DiD risk monitor software. Furthermore, the simulation result is shown for the interactions between the actors which are defined in the plant DiD risk monitor system as PLANT actor, OPERATOR actor, and SUPERVISOR actor. This paper shows that it is feasible to model the nuclear power plant knowledge base using the software modeling technique. The software can make the large knowledge base for the nuclear power plant with small effort.
- 23 February 2017
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 54 (5) , 552-568
Knowledge-based software design for Defense-in-Depth risk monitor system and application for AP1000
As part of the new risk monitor system, the software for the plant Defense-in-Depth (DiD) risk monitor system was designed based on the state-transition and finite-state machine, and then the knowledge-based software was developed by object-oriented method utilizing the Unified Modeling Language (UML). Currently, there are mainly two functions in the developed plant DiD risk monitor software that are knowledge-base editor which is used to model the system in a hierarchical manner and the interaction simulator that simulates the interactions between the different actors in the model. In this paper, a model for playing its behavior is called an Actor which is modeled at the top level. The passive safety AP1000 power plant was studied and the small-break loss-of-coolant accident (SBLOCA) design basis accident transient is modeled using the plant DiD risk monitor software. Furthermore, the simulation result is shown for the interactions between the actors which are defined in the plant DiD risk monitor system as PLANT actor, OPERATOR actor, and SUPERVISOR actor. This paper shows that it is feasible to model the nuclear power plant knowledge base using the software modeling technique. The software can make the large knowledge base for the nuclear power plant with small effort.
- 29 March 2016
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 53 (11) , 1794-1808
Modification of thermal hydraulic code, THEATRe, with fuel rod behavior models and its application to reactivity-initiated accident (RIA)
During reactor operation, many complex changes occur in fuel rod which affects its thermal, mechanical and material properties. These changes also affect the reactor response to the transient and accident situations. Realistic simulation of fuel rod behavior under transients such as reactivity-initiated accident (RIA) is of great significance. In this study, thermal hydraulic analysis code THEATRe (Thermal Hydraulic Engineering Analysis Tool in Real-time) has been modified by addition of fuel rod behavior models for dynamic simulation of nuclear reactor. Transient changes in gas-gap parameters were taken into account by modeling the gas-gap behavior. Thermo-mechanical behavior of fuel rod is modeled to take into account the thermal, elastic and plastic deformation. To simulate RIA, point reactor kinetics model is also incorporated in the THEATRe code. To demonstrate the transient fuel rod behavior, AP1000 reactor is modeled and three hypothetical RIA cases are simulated. The RIA is considered at three different reactor power levels, i.e. 100, 50 and 1% of nominal power. The investigated parameters are fuel temperature, cladding stress and strain, fuel and cladding thermal conductivity and heat transfer coefficient in gas-gap. Modified code calculates the fuel rod temperatures according to updated fuel, clad and gas-gap parameters at the onset of steady-state operation and during the transient. The modified code provides lower steady-state fuel temperature as compared to the original code. Stress and strain analyses indicate that the hoop and radial strain is higher at high power locations of the fuel rod; therefore, gap closure process will initially occur in the central portion of the fuel rod and it should be given more emphasis in the safety analysis of the fuel rod and nuclear reactor during accidents and transients.
- 29 March 2016
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 53 (11) , 1794-1808
Modification of thermal hydraulic code, THEATRe, with fuel rod behavior models and its application to reactivity-initiated accident (RIA)
During reactor operation, many complex changes occur in fuel rod which affects its thermal, mechanical and material properties. These changes also affect the reactor response to the transient and accident situations. Realistic simulation of fuel rod behavior under transients such as reactivity-initiated accident (RIA) is of great significance. In this study, thermal hydraulic analysis code THEATRe (Thermal Hydraulic Engineering Analysis Tool in Real-time) has been modified by addition of fuel rod behavior models for dynamic simulation of nuclear reactor. Transient changes in gas-gap parameters were taken into account by modeling the gas-gap behavior. Thermo-mechanical behavior of fuel rod is modeled to take into account the thermal, elastic and plastic deformation. To simulate RIA, point reactor kinetics model is also incorporated in the THEATRe code. To demonstrate the transient fuel rod behavior, AP1000 reactor is modeled and three hypothetical RIA cases are simulated. The RIA is considered at three different reactor power levels, i.e. 100, 50 and 1% of nominal power. The investigated parameters are fuel temperature, cladding stress and strain, fuel and cladding thermal conductivity and heat transfer coefficient in gas-gap. Modified code calculates the fuel rod temperatures according to updated fuel, clad and gas-gap parameters at the onset of steady-state operation and during the transient. The modified code provides lower steady-state fuel temperature as compared to the original code. Stress and strain analyses indicate that the hoop and radial strain is higher at high power locations of the fuel rod; therefore, gap closure process will initially occur in the central portion of the fuel rod and it should be given more emphasis in the safety analysis of the fuel rod and nuclear reactor during accidents and transients.
- 23 August 2014
- Published by Elsevier in Nuclear Engineering and Design
- Vol. 278, 255-267
Development of a risk monitoring system for nuclear power plants based on GO-FLOW methodology
- 23 August 2014
- Published by Elsevier in Nuclear Engineering and Design
- Vol. 278, 255-267
Development of a risk monitoring system for nuclear power plants based on GO-FLOW methodology
- Open Access
- 5 February 2014
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 51 (4) , 526-542
Quantitative dynamic reliability evaluation of AP1000 passive safety systems by using FMEA and GO-FLOW methodology
The passive safety systems utilized in advanced pressurized water reactor (PWR) design such as AP1000 should be more reliable than that of active safety systems of conventional PWR by less possible opportunities of hardware failures and human errors (less human intervention). The objectives of present study are to evaluate the dynamic reliability of AP1000 plant in order to check the effectiveness of passive safety systems by comparing the reliability-related issues with that of active safety systems in the event of the big accidents. How should the dynamic reliability of passive safety systems properly evaluated? And then what will be the comparison of reliability results of AP1000 passive safety systems with the active safety systems of conventional PWR. For this purpose, a single loop model of AP1000 passive core cooling system (PXS) and passive containment cooling system (PCCS) are assumed separately for quantitative reliability evaluation. The transient behaviors of these passive safety systems are taken under the large break loss-of-coolant accident in the cold leg. The analysis is made by utilizing the qualitative method failure mode and effect analysis in order to identify the potential failure mode and success-oriented reliability analysis tool called GO-FLOW for quantitative reliability evaluation. The GO-FLOW analysis has been conducted separately for PXS and PCCS systems under the same accident. The analysis results show that reliability of AP1000 passive safety systems (PXS and PCCS) is increased due to redundancies and diversity of passive safety subsystems and components, and four stages automatic depressurization system is the key subsystem for successful actuation of PXS and PCCS system. The reliability results of PCCS system of AP1000 are more reliable than that of the containment spray system of conventional PWR. And also GO-FLOW method can be utilized for reliability evaluation of passive safety systems.
- 5 February 2014
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 51 (4) , 526-542
Open AccessQuantitative dynamic reliability evaluation of AP1000 passive safety systems by using FMEA and GO-FLOW methodology
The passive safety systems utilized in advanced pressurized water reactor (PWR) design such as AP1000 should be more reliable than that of active safety systems of conventional PWR by less possible opportunities of hardware failures and human errors (less human intervention). The objectives of present study are to evaluate the dynamic reliability of AP1000 plant in order to check the effectiveness of passive safety systems by comparing the reliability-related issues with that of active safety systems in the event of the big accidents. How should the dynamic reliability of passive safety systems properly evaluated? And then what will be the comparison of reliability results of AP1000 passive safety systems with the active safety systems of conventional PWR. For this purpose, a single loop model of AP1000 passive core cooling system (PXS) and passive containment cooling system (PCCS) are assumed separately for quantitative reliability evaluation. The transient behaviors of these passive safety systems are taken under the large break loss-of-coolant accident in the cold leg. The analysis is made by utilizing the qualitative method failure mode and effect analysis in order to identify the potential failure mode and success-oriented reliability analysis tool called GO-FLOW for quantitative reliability evaluation. The GO-FLOW analysis has been conducted separately for PXS and PCCS systems under the same accident. The analysis results show that reliability of AP1000 passive safety systems (PXS and PCCS) is increased due to redundancies and diversity of passive safety subsystems and components, and four stages automatic depressurization system is the key subsystem for successful actuation of PXS and PCCS system. The reliability results of PCCS system of AP1000 are more reliable than that of the containment spray system of conventional PWR. And also GO-FLOW method can be utilized for reliability evaluation of passive safety systems.