Lanqun Mao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Lanqun Mao has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Fang Xub
1 shared publicationHuiping Tu
Department of Chemistry, East China Normal University, Shanghai 200062, P.R. China
1 shared publicationKatsunobu Yamamoto
Department of Electronic Chemistry, Interdisciplinary Graduate School of Science and Engineering, Tokyo Institute of Technology, 4259 Nagatsuta, Midori-ku, Yokohama 226-8502, Japan, Department of Research and Development, BioelectroAnalytical Science Inc., 1-36-6 Oshiage, Sumida-ku, Tokyo 131-0045, Japan, and Laboratory of Molecular Recognition, Graduate School of Integrated Science, Yokohama City University, 22-2 Seto, Kanazawa-ku,Yokohama 236-0027, Japan
1 shared publication- Litong Jin
Department of Chemistry, East China Normal University, Shanghai 200062, China
1 shared publication Litong Jinb
1 shared publicationPeter G. Osborne
Department of Electronic Chemistry, Interdisciplinary Graduate School of Science and Engineering, Tokyo Institute of Technology, 4259 Nagatsuta, Midori-ku, Yokohama 226-8502, Japan, Department of Research and Development, BioelectroAnalytical Science Inc., 1-36-6 Oshiage, Sumida-ku, Tokyo 131-0045, Japan, and Laboratory of Molecular Recognition, Graduate School of Integrated Science, Yokohama City University, 22-2 Seto, Kanazawa-ku,Yokohama 236-0027, Japan
1 shared publication
Latest Publications
- 25 June 2002
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 74 (15) , 3684-3689
Continuous On-Line Measurement of Cerebral Hydrogen Peroxide Using Enzyme-Modified Ring−Disk Plastic Carbon Film Electrode
An amperometric method suitable for the continuous on-line measurement of cerebral hydrogen peroxide from a microdialysate has been successfully performed for the first time by using an enzyme-modified ring−disk plastic carbon film electrode (PCFE) in a thin-layer radial flow cell. PCFE consists of a ring electrode modified with horseradish peroxidase to detect H2O2 at 0.0 V (vs Ag/AgCl) and a disk electrode coated with ascorbate oxidase (AOx) to preoxidize ascorbic acid (AA) and thus suppress interference via direct oxidation. Analytes in solution (brain dialysates or standards) are mixed on-line with a phosphate-buffered solution containing dissolved oxygen and chelating agent, EDTA. The buffered solution is used to provide the O2 necessary for the AOx catalytic reaction, stabilize the changes in dialysate pH that are associated with the in vivo formation of H2O2, and remove heavy metal ion impurities and thus suppress reactions between AA and H2O2. This procedure enables trace levels of H2O2 to be readily monitored, virtually interference-free from physiological levels of AA, uric acid, electroactive neurotransmitters and their principle metabolites, in a continuous-flow system.
- 25 June 2002
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 74 (15) , 3684-3689
Continuous On-Line Measurement of Cerebral Hydrogen Peroxide Using Enzyme-Modified Ring−Disk Plastic Carbon Film Electrode
An amperometric method suitable for the continuous on-line measurement of cerebral hydrogen peroxide from a microdialysate has been successfully performed for the first time by using an enzyme-modified ring−disk plastic carbon film electrode (PCFE) in a thin-layer radial flow cell. PCFE consists of a ring electrode modified with horseradish peroxidase to detect H2O2 at 0.0 V (vs Ag/AgCl) and a disk electrode coated with ascorbate oxidase (AOx) to preoxidize ascorbic acid (AA) and thus suppress interference via direct oxidation. Analytes in solution (brain dialysates or standards) are mixed on-line with a phosphate-buffered solution containing dissolved oxygen and chelating agent, EDTA. The buffered solution is used to provide the O2 necessary for the AOx catalytic reaction, stabilize the changes in dialysate pH that are associated with the in vivo formation of H2O2, and remove heavy metal ion impurities and thus suppress reactions between AA and H2O2. This procedure enables trace levels of H2O2 to be readily monitored, virtually interference-free from physiological levels of AA, uric acid, electroactive neurotransmitters and their principle metabolites, in a continuous-flow system.
- 1 May 2001
- Published by Elsevier in Analytical Biochemistry
- Vol. 292 (1) , 94-101
Miniaturized Amperometric Biosensor Based on Xanthine Oxidase for Monitoring Hypoxanthine in Cell Culture Media
- 1 May 2001
- Published by Elsevier in Analytical Biochemistry
- Vol. 292 (1) , 94-101
Miniaturized Amperometric Biosensor Based on Xanthine Oxidase for Monitoring Hypoxanthine in Cell Culture Media
- 1 January 1999
- Published by Wiley in Electroanalysis
- Vol. 11 (1) , 70-74
A Novel Electrochemical Microsensor for Nitric Oxide Based on Electropolymerized Film ofo-Aminobenzaldehyde-ethylene-diamine Nickel
- 1 January 1999
- Published by Wiley in Electroanalysis
- Vol. 11 (1) , 70-74
A Novel Electrochemical Microsensor for Nitric Oxide Based on Electropolymerized Film ofo-Aminobenzaldehyde-ethylene-diamine Nickel