Shinichi Toyooka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shinichi Toyooka has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Hideo Gobara
Division of Medical Informatics, Okayama University Hospital, Okayama, Japan
5 shared publications - Hiroyasu Fujiwara
Okayama University Medical School
5 shared publications - Susumu Kanazawa
Department of Radiology, Okayama University Medical School, 2-5-1 Shikata-cho kita-ku, Okayama, 700-8558, Japan
5 shared publications - Takao Hiraki
Department of Radiology, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama, Japan
5 shared publications - Toshihiro Iguchi
Department of Radiological Technology, Faculty of Health Sciences, Okayama University, Okayama, Japan
5 shared publications - Yusuke Matsui
Okayama University Medical School
3 shared publications
Latest Publications
- 1 October 2018
- Published by Elsevier in Diagnostic and Interventional Imaging
- Vol. 99 (10) , 591-597
Short hookwire placement under imaging guidance before thoracic surgery: A review
- 1 October 2018
- Published by Elsevier in Diagnostic and Interventional Imaging
- Vol. 99 (10) , 591-597
Short hookwire placement under imaging guidance before thoracic surgery: A review
- 1 July 2017
- Published by Elsevier in Diagnostic and Interventional Imaging
- Vol. 98 (7-8) , 535-541
Radiofrequency ablation of pulmonary tumors near the diaphragm
- 1 July 2017
- Published by Elsevier in Diagnostic and Interventional Imaging
- Vol. 98 (7-8) , 535-541
Radiofrequency ablation of pulmonary tumors near the diaphragm
- 3 December 2014
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 38 (4) , 971-976
Simultaneous Multiple Preoperative Localizations of Small Pulmonary Lesions Using a Short Hook Wire and Suture System
The aim of the study was to retrospectively evaluate simultaneous multiple hook wire placement outcomes before video-assisted thoracoscopic surgery (VATS). Thirty-eight procedures were performed on 35 patients (13 men and 22 women; mean age, 59.9 years) with 80 lung lesions (mean diameter 7.9 mm) who underwent simultaneous multiple hook wire placements for preoperative localizations. The primary endpoints were technical success, complications, procedure duration, and VATS outcome; secondary endpoints included comparisons between technical success rates, complication rates, and procedure durations of the 238 single-placement procedures performed. Complications were also evaluated. In 35 procedures including 74 lesions, multiple hook wire placements were technically successful; in the remaining three procedures, the second target placement was aborted because of massive pneumothorax after the first placement. Although complications occurred in 34 procedures, no grade 3 or above adverse event was observed. The mean procedure duration was 36.4 ± 11.8 min. Three hook wires dislodged during patient transport to the surgical suite. Seventy-four successfully marked lesions were resected. Six lesions without hook wires were successfully resected after detection by palpation with an additional mini-thoracotomy or using subtle pleural changes as a guide. The complication rates and procedure durations of multiple-placement procedures were significantly higher (P = 0.04) and longer (P < 0.001) than those in the single-placement group, respectively, while the technical success rate was not significantly different (P = 0.051). Simultaneous multiple hook wire placements before VATS were clinically feasible, but increased the complication rate and lengthened the procedure time.
- 3 December 2014
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 38 (4) , 971-976
Simultaneous Multiple Preoperative Localizations of Small Pulmonary Lesions Using a Short Hook Wire and Suture System
The aim of the study was to retrospectively evaluate simultaneous multiple hook wire placement outcomes before video-assisted thoracoscopic surgery (VATS). Thirty-eight procedures were performed on 35 patients (13 men and 22 women; mean age, 59.9 years) with 80 lung lesions (mean diameter 7.9 mm) who underwent simultaneous multiple hook wire placements for preoperative localizations. The primary endpoints were technical success, complications, procedure duration, and VATS outcome; secondary endpoints included comparisons between technical success rates, complication rates, and procedure durations of the 238 single-placement procedures performed. Complications were also evaluated. In 35 procedures including 74 lesions, multiple hook wire placements were technically successful; in the remaining three procedures, the second target placement was aborted because of massive pneumothorax after the first placement. Although complications occurred in 34 procedures, no grade 3 or above adverse event was observed. The mean procedure duration was 36.4 ± 11.8 min. Three hook wires dislodged during patient transport to the surgical suite. Seventy-four successfully marked lesions were resected. Six lesions without hook wires were successfully resected after detection by palpation with an additional mini-thoracotomy or using subtle pleural changes as a guide. The complication rates and procedure durations of multiple-placement procedures were significantly higher (P = 0.04) and longer (P < 0.001) than those in the single-placement group, respectively, while the technical success rate was not significantly different (P = 0.051). Simultaneous multiple hook wire placements before VATS were clinically feasible, but increased the complication rate and lengthened the procedure time.
- 18 June 2014
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 38 (2) , 409-415
Percutaneous Radiofrequency Ablation of Lung Cancer Presenting as Ground-Glass Opacity
We retrospectively evaluated the outcomes of lung cancer patients presenting with ground-glass opacity (GGO) who received radiofrequency ablation (RFA). Sixteen patients (5 men and 11 women; mean age, 72.6 years) with 17 lung cancer lesions showing GGO (mean long axis diameter, 1.6 cm) underwent a total of 20 percutaneous computed tomography (CT) fluoroscopy-guided RFA sessions, including three repeated sessions for local progression. Lung cancer with GGO was defined as a histologically confirmed malignant pulmonary lesion with a GGO component accounting for >50 % of the lesion on high-resolution CT. Procedure outcomes were evaluated. There were no major complications. Pneumothorax occurred in 15 of 20 treatment sessions: 14 were asymptomatic, and 1 required chest tube placement but resolved satisfactorily within 48 h. Minor pulmonary hemorrhage occurred in two and mild pneumonitis in one. The median tumor follow-up period was 61.5 (range 6.1–96.6) months. The effectiveness rates of the primary and secondary techniques were 100 and 100 % at 1 year, 93.3 and 100 % at 2 years, and 78.3 and 92.3 % at 3 years, respectively. The median patient follow-up period was 65.6 (range 6.1–96.6) months. One patient died owing to recurrent other cancer 11.7 months after RFA, whereas the other 15 remained alive. Overall survival and disease-specific survival rates were 93.3 and 100 % at 1 year and 93.3 and 100 % at 5 years, respectively. RFA for lung cancer with GGO was safe and effective, and resulted in promising survival rates.
- 18 June 2014
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 38 (2) , 409-415
Percutaneous Radiofrequency Ablation of Lung Cancer Presenting as Ground-Glass Opacity
We retrospectively evaluated the outcomes of lung cancer patients presenting with ground-glass opacity (GGO) who received radiofrequency ablation (RFA). Sixteen patients (5 men and 11 women; mean age, 72.6 years) with 17 lung cancer lesions showing GGO (mean long axis diameter, 1.6 cm) underwent a total of 20 percutaneous computed tomography (CT) fluoroscopy-guided RFA sessions, including three repeated sessions for local progression. Lung cancer with GGO was defined as a histologically confirmed malignant pulmonary lesion with a GGO component accounting for >50 % of the lesion on high-resolution CT. Procedure outcomes were evaluated. There were no major complications. Pneumothorax occurred in 15 of 20 treatment sessions: 14 were asymptomatic, and 1 required chest tube placement but resolved satisfactorily within 48 h. Minor pulmonary hemorrhage occurred in two and mild pneumonitis in one. The median tumor follow-up period was 61.5 (range 6.1–96.6) months. The effectiveness rates of the primary and secondary techniques were 100 and 100 % at 1 year, 93.3 and 100 % at 2 years, and 78.3 and 92.3 % at 3 years, respectively. The median patient follow-up period was 65.6 (range 6.1–96.6) months. One patient died owing to recurrent other cancer 11.7 months after RFA, whereas the other 15 remained alive. Overall survival and disease-specific survival rates were 93.3 and 100 % at 1 year and 93.3 and 100 % at 5 years, respectively. RFA for lung cancer with GGO was safe and effective, and resulted in promising survival rates.
- 20 February 2014
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 38 (1) , 222-226
Transfissural Route Used for Preoperative Localization of Small Pulmonary Lesions with a Short Hook Wire and Suture System
We retrospectively evaluated the results of the transfissural route for preoperative localization with a short hook wire and suture system for video-assisted thoracoscopic surgery (VATS). Eleven patients with 11 tumors underwent CT-guided transfissural placement of a hook wire before VATS. This route was selected for all patients, because the distance between the tumor and interlobar fissure was much shorter than the required distance traversed using the conventional approach. Complications were evaluated using the National Cancer Institute Common Terminology Criteria for Adverse Events Version 4.0. The hook wire was successfully placed using the transfissural route in all but one case. Of these ten successful placements, two tumors needed a second puncture for optimal placement, because the CT scan showed that the first hook wire was not properly placed in the lung. In one patient, we did not attempt replacement after the first placement was incorrect. In ten successful procedures, the mean distance traversed in the parenchyma of the unaffected lung lobe was 27.9 mm. The distance between the pleura and placed hook wire was significantly shorter than the estimated distance between the pleura and hook wire using the conventional route (mean 16.3 vs. 40.9 mm; P = 0.0002). Grade 1 adverse events occurred (11 pneumothoraxes and 4 pulmonary hemorrhages). No grade 2 or higher adverse event was observed. The transfissural route used for preoperative localization before VATS is useful for selected patients because this route may allow for more limited lung parenchyma resection.
- 20 February 2014
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 38 (1) , 222-226
Transfissural Route Used for Preoperative Localization of Small Pulmonary Lesions with a Short Hook Wire and Suture System
We retrospectively evaluated the results of the transfissural route for preoperative localization with a short hook wire and suture system for video-assisted thoracoscopic surgery (VATS). Eleven patients with 11 tumors underwent CT-guided transfissural placement of a hook wire before VATS. This route was selected for all patients, because the distance between the tumor and interlobar fissure was much shorter than the required distance traversed using the conventional approach. Complications were evaluated using the National Cancer Institute Common Terminology Criteria for Adverse Events Version 4.0. The hook wire was successfully placed using the transfissural route in all but one case. Of these ten successful placements, two tumors needed a second puncture for optimal placement, because the CT scan showed that the first hook wire was not properly placed in the lung. In one patient, we did not attempt replacement after the first placement was incorrect. In ten successful procedures, the mean distance traversed in the parenchyma of the unaffected lung lobe was 27.9 mm. The distance between the pleura and placed hook wire was significantly shorter than the estimated distance between the pleura and hook wire using the conventional route (mean 16.3 vs. 40.9 mm; P = 0.0002). Grade 1 adverse events occurred (11 pneumothoraxes and 4 pulmonary hemorrhages). No grade 2 or higher adverse event was observed. The transfissural route used for preoperative localization before VATS is useful for selected patients because this route may allow for more limited lung parenchyma resection.