XZXiaofeng Zhu

Xiaofeng Zhu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Xiaofeng Zhu has a total of 25 co-authors. Here are the top co-authors by number of shared publications:

  • Taoran Li

    Department of Radiation Oncology, Perelman School of Medicine of the University of Pennsylvania, Perelman Center for Advanced Medicine, Philadelphia, Pennsylvania

    2 shared publications
  • Timothy Cullip

    Department of Radiation Oncology, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27514

    2 shared publications
  • Andrew Zhuang Wang

    Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, USA

    1 shared publication
  • Charles A. Enke

    Department of Radiation Oncology, University of Nebraska Medical Center, Omaha, Nebraska 68154

    1 shared publication
  • Dandan Zheng

    Department of Radiation Oncology, University of Rochester, Rochester, NY 14642, USA

    1 shared publication
  • Danthai Thongphiew

    Department of Radiation Oncology, Brody School of Medicine, East Carolina University, Greenville, North Carolina 27834

    1 shared publication

Latest Publications

  • Technical Note: Fabricating Cerrobend grids with 3D printing for spatially modulated radiation therapy: A feasibility study

    by Xiaofeng Zhu, Joseph Driewer, Sicong Li, Vivek Verma, Yu Lei, Mutian Zhang, Qinghui Zhang, Dandan Zheng, Timothy Cullip, Sha X. Chang, et al.

    Purpose: Grid therapy has promising applications in the radiation treatment of large tumors. However, research and applications of grid therapy are limited by the accessibility of the specialized blocks that produce the grid of pencil‐like radiation beams. In this study, a Cerrobend grid block was fabricated using the 3D printing technique. Methods: A grid block mold was designed with flared tubes which follow the divergence of the beam. The mold was 3D printed using a resin with the working temperature below 230 °C. The melted Cerrobend liquid at 120 °C was cast into the resin mold to yield a block with a thickness of 7.4 cm. At the isocenter plane, the grid had a hexagonal pattern, with each pencil beam diameter of 1.4 cm; the distance between the beam centers was 2.1 cm. Results: The dosimetric properties of the grid block were studied using small field dosimeters: a pinpoint ionization chamber and a stereotactic diode. For a 6 MV photon beam, its valley‐to‐peak ratio was 20% at dmax and 30% at 10 cm depth; the output factor was 84.9% at dmax and 65.1% at 10 cm depth. Conclusions: This study demonstrates that it is feasible to implement 3D printing technique in applying grid therapy in clinic.


  • Open Access

    Direct aperture optimization using an inverse form of back‐projection

    by Xiaofeng Zhu, Timothy Cullip, Gregg Tracton, Xiaoli Tang, Jun Lian, John Dooley, Sha X Chang

    Direct aperture optimization (DAO) has been used to produce high dosimetric quality intensity-modulated radiotherapy (IMRT) treatment plans with fast treatment delivery by directly modeling the multileaf collimator segment shapes and weights. To improve plan quality and reduce treatment time for our in-house treatment planning system, we implemented a new DAO approach without using a global objective function (GFO). An index concept is introduced as an inverse form of back-projection used in the CT multiplicative algebraic reconstruction technique (MART). The index, introduced for IMRT optimization in this work, is analogous to the multiplicand in MART. The index is defined as the ratio of the optima over the current. It is assigned to each voxel and beamlet to optimize the fluence map. The indices for beamlets and segments are used to optimize multileaf collimator (MLC) segment shapes and segment weights, respectively. Preliminary data show that without sacrificing dosimetric quality, the implementation of the DAO reduced average IMRT treatment time from 13 min to 8 min for the prostate, and from 15 min to 9 min for the head and neck using our in-house treatment planning system PlanUNC. The DAO approach has also shown promise in optimizing rotational IMRT with burst mode in a head and neck test case. PACS number: 87.55.D-


  • Top Cited Papers

    A planning quality evaluation tool for prostate adaptive IMRT based on machine learning

    by Xiaofeng Zhu, Yaorong Ge, Taoran Li, Danthai Thongphiew, Fang‐Fang Yin, Q Jackie Wu

    Purpose: To ensure plan quality for adaptive IMRT of the prostate, we developed a quantitative evaluation tool using a machine learning approach. This tool generates dose volume histograms (DVHs) of organs‐at‐risk (OARs) based on prior plans as a reference, to be compared with the adaptive plan derived from fluence map deformation.Methods: Under the same configuration using seven‐field 15 MV photon beams, DVHs of OARs (bladder and rectum) were estimated based on anatomical information of the patient and a model learned from a database of high quality prior plans. In this study, the anatomical information was characterized by the organ volumes and distance‐to‐target histogram (DTH). The database consists of 198 high quality prostate plans and was validated with 14 cases outside the training pool. Principal component analysis (PCA) was applied to DVHs and DTHs to quantify their salient features. Then, support vector regression (SVR) was implemented to establish the correlation between the features of the DVH and the anatomical information.Results: DVH/DTH curves could be characterized sufficiently just using only two or three truncated principal components, thus, patient anatomical information was quantified with reduced numbers of variables. The evaluation of the model using the test data set demonstrated its accuracy in prediction and effectiveness in improving ART planning quality.Conclusions: An adaptive IMRT plan quality evaluation tool based on machine learning has been developed, which estimates OAR sparing and provides reference in evaluating ART.