James A. Tanyi
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
James A. Tanyi has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Bill J. Salter
1 shared publication- Bill J. Salter
Department of Radiation Oncology, University of Utah, Salt Lake City, Utah
1 shared publication - Jack L. Lancaster
Research Imaging Center, University of Texas Health Science Center at San Antonio
1 shared publication Martin Fuss
1 shared publication- Martin Fuss
Department of Radiation Medicine, Oregon Health & Science University, Portland, OR, USA
1 shared publication - Shane Paul Krafft
Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, TX, 77030, USA
1 shared publication
Latest Publications
- 11 December 2007
- Published by Wiley in Medical Physics
- Vol. 35 (1) , 39-47
MOSFET sensitivity dependence on integrated dose from high‐energy photon beams
The ability of a commercially available dual bias, dual MOSFET dosimetry system to measure therapeutic doses reproducibly throughout its vendor‐defined dose‐based lifetime has been evaluated by characterizing its sensitivity variation to integrated/cumulative doses from high‐energy (6 and 15 MV) photon radiotherapy beams. The variation of sensitivity as a function of total integrated dose was studied for three different dose‐per‐fraction levels; namely, 50, 200, and 1200 cGy/fraction. In standard sensitivity mode (i.e., measurements involving dose‐per‐fraction levels ), the response of the MOSFET system to identical irradiations increased with integrated dose for both energies investigated. Dose measurement reproducibility for the low (i.e., 50 cGy) dose fractions was within (if the system was calibrated before each in‐phantom measurement) and [if the system was calibrated prior to first use, with no intermediate calibration(s)]. Similarly, dose measurement reproducibility was between and for the conventional (i.e., 200 cGy) dose fractions and between and for escalated (i.e., 1200 cGy) dose fractions. The results of this study suggest that, due to the progressively increasing sensitivity resulting from the dual‐MOSFET design, frequent calibrations are required to achieve measurement accuracy of (within one standard deviation).
- 11 December 2007
- Published by Wiley in Medical Physics
- Vol. 35 (1) , 39-47
MOSFET sensitivity dependence on integrated dose from high‐energy photon beams
The ability of a commercially available dual bias, dual MOSFET dosimetry system to measure therapeutic doses reproducibly throughout its vendor‐defined dose‐based lifetime has been evaluated by characterizing its sensitivity variation to integrated/cumulative doses from high‐energy (6 and 15 MV) photon radiotherapy beams. The variation of sensitivity as a function of total integrated dose was studied for three different dose‐per‐fraction levels; namely, 50, 200, and 1200 cGy/fraction. In standard sensitivity mode (i.e., measurements involving dose‐per‐fraction levels ), the response of the MOSFET system to identical irradiations increased with integrated dose for both energies investigated. Dose measurement reproducibility for the low (i.e., 50 cGy) dose fractions was within (if the system was calibrated before each in‐phantom measurement) and [if the system was calibrated prior to first use, with no intermediate calibration(s)]. Similarly, dose measurement reproducibility was between and for the conventional (i.e., 200 cGy) dose fractions and between and for escalated (i.e., 1200 cGy) dose fractions. The results of this study suggest that, due to the progressively increasing sensitivity resulting from the dual‐MOSFET design, frequent calibrations are required to achieve measurement accuracy of (within one standard deviation).
- Open Access
- 1 December 2007
- Published by Springer Nature in Radiation Oncology
- Vol. 2 (1) , 10
Phantom investigation of 3D motion-dependent volume aliasing during CT simulation for radiation therapy planning
Purpose To quantify volumetric and positional aliasing during non-gated fast- and slow-scan acquisition CT in the presence of 3D target motion. Methods Single-slice fast, single-slice slow, and multi-slice fast scan helical CTs were acquired of dynamic spherical targets (1 and 3.15 cm in diameter), embedded in an anthropomorphic phantom. 3D target motions typical of clinically observed tumor motion parameters were investigated. Motion excursions included ± 5, ± 10, and ± 15 mm displacements in the S-I direction synchronized with constant displacements of ± 5 and ± 2 mm in the A-P and lateral directions, respectively. For each target, scan technique, and motion excursion, eight different initial motion-to-scan phase relationships were investigated. Results An anticipated general trend of target volume overestimation was observed. The mean percentage overestimation of the true physical target volume typically increased with target motion amplitude and decreasing target diameter. Slow-scan percentage overestimations were larger, and better approximated the time-averaged motion envelope, as opposed to fast-scans. Motion induced centroid misrepresentation was greater in the S-I direction for fast-scan techniques, and transaxial direction for the slow-scan technique. Overestimation is fairly uniform for slice widths < 5 mm, beyond which there is gross overestimation. Conclusion Non-gated CT imaging of targets describing clinically relevant, 3D motion results in aliased overestimation of the target volume and misrepresentation of centroid location, with little or no correlation between the physical target geometry and the CT-generated target geometry. Slow-scan techniques are a practical method for characterizing time-averaged target position. Fast-scan techniques provide a more reliable, albeit still distorted, target margin.
- 1 December 2007
- Published by Springer Nature in Radiation Oncology
- Vol. 2 (1) , 10
Open AccessPhantom investigation of 3D motion-dependent volume aliasing during CT simulation for radiation therapy planning
Purpose To quantify volumetric and positional aliasing during non-gated fast- and slow-scan acquisition CT in the presence of 3D target motion. Methods Single-slice fast, single-slice slow, and multi-slice fast scan helical CTs were acquired of dynamic spherical targets (1 and 3.15 cm in diameter), embedded in an anthropomorphic phantom. 3D target motions typical of clinically observed tumor motion parameters were investigated. Motion excursions included ± 5, ± 10, and ± 15 mm displacements in the S-I direction synchronized with constant displacements of ± 5 and ± 2 mm in the A-P and lateral directions, respectively. For each target, scan technique, and motion excursion, eight different initial motion-to-scan phase relationships were investigated. Results An anticipated general trend of target volume overestimation was observed. The mean percentage overestimation of the true physical target volume typically increased with target motion amplitude and decreasing target diameter. Slow-scan percentage overestimations were larger, and better approximated the time-averaged motion envelope, as opposed to fast-scans. Motion induced centroid misrepresentation was greater in the S-I direction for fast-scan techniques, and transaxial direction for the slow-scan technique. Overestimation is fairly uniform for slice widths < 5 mm, beyond which there is gross overestimation. Conclusion Non-gated CT imaging of targets describing clinically relevant, 3D motion results in aliased overestimation of the target volume and misrepresentation of centroid location, with little or no correlation between the physical target geometry and the CT-generated target geometry. Slow-scan techniques are a practical method for characterizing time-averaged target position. Fast-scan techniques provide a more reliable, albeit still distorted, target margin.