MOSFET sensitivity dependence on integrated dose from high‐energy photon beams
Authors:
- James A. TanyiJTJames A. Tanyi
- Shane P. KrafftSKShane P. Krafft
- Tomoe HagioTHTomoe Hagio
- Martin FussMFMartin Fuss
- Bill J. SalterBSBill J. Salter
- 11 December 2007
- journal article
- Published by Wiley in Medical Physics
- Vol. 35 (1) , 39-47
Abstract
The ability of a commercially available dual bias, dual MOSFET dosimetry system to measure therapeutic doses reproducibly throughout its vendor‐defined dose‐based lifetime has been evaluated by characterizing its sensitivity variation to integrated/cumulative doses from high‐energy (6 and 15 MV) photon radiotherapy beams. The variation of sensitivity as a function of total integrated dose was studied for three different dose‐per‐fraction levels; namely, 50, 200, and 1200 cGy/fraction. In standard sensitivity mode (i.e., measurements involving dose‐per‐fraction levels ), the response of the MOSFET system to identical irradiations increased with integrated dose for both energies investigated. Dose measurement reproducibility for the low (i.e., 50 cGy) dose fractions was within (if the system was calibrated before each in‐phantom measurement) and [if the system was calibrated prior to first use, with no intermediate calibration(s)]. Similarly, dose measurement reproducibility was between and for the conventional (i.e., 200 cGy) dose fractions and between and for escalated (i.e., 1200 cGy) dose fractions. The results of this study suggest that, due to the progressively increasing sensitivity resulting from the dual‐MOSFET design, frequent calibrations are required to achieve measurement accuracy of (within one standard deviation).Keywords
This publication has 21 references indexed in Scilit:
- Characterization of responses and comparison of calibration factor for commercial MOSFET detectorsMedical Dosimetry, 2005
- Performance characteristics of a microMOSFET as anin vivodosimeter in radiation therapyPhysics in Medicine & Biology, 2004
- Radiation effects and hardening of MOS technology: devices and circuitsIEEE Transactions on Nuclear Science, 2003
- Total ionizing dose effects in MOS oxides and devicesIEEE Transactions on Nuclear Science, 2003
- A review of the 40-year history of the NSREC'S dosimetry and facilities session (1963-2003)IEEE Transactions on Nuclear Science, 2003
- Investigation of the use of MOSFET for clinical IMRT dosimetric verificationMedical Physics, 2002
- Measurement of radiotherapy x‐ray skin dose on a chest wall phantomMedical Physics, 2000
- Clinical dosimetry using mosfetsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1997
- Evaluation of a dual bias dual metal oxide‐silicon semiconductor field effect transistor detector as radiation dosimeterMedical Physics, 1994
- Automated data collection and analysis system for MOSFET radiation detectorsMedical Physics, 1991