Matthias Goldammer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Matthias Goldammer has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- C. Homma
Corporate Research and Technologies 1 Siemens AG Otto-Hahn-Ring 6, 81739 Munich, Germany
2 shared publications - Hubert Mooshofer
Siemens AG, Corporate Technology, Otto-Hahn-Ring 6, 81739 München, Germany
2 shared publications K. Eisler
Siemens AG, Corporate Research and Technologies, Otto-Hahn-Ring 6, 81739 Munich, Germany
2 shared publications- M. Rothenfusser
Corporate Research and Technologies 1 Siemens AG Otto-Hahn-Ring 6, 81739 Munich, Germany
2 shared publications - Achim Basermann
German Aerospace Center, Institute of Software Technology, Oberpfaffenhofen/Cologne, Germany
1 shared publication - Andrea Walther
Humboldt-Universität zu Berlin, Berlin, Germany
1 shared publication
Latest Publications
- Open Access
THz-TDS Reflection Measurement of Coating Thicknesses at Non-Perpendicular Incidence: Experiment and Simulation
Time-domain spectroscopy (TDS) in the terahertz (THz) frequency range is gaining in importance in nondestructive testing of dielectric materials. One application is the layer thickness measurement of a coating layer. To determine the thickness from the measurement data, the refractive index of the coating layer must be known in the surveyed frequency range. For perpendicular incidence of the radiation, methods exist to extract the refractive index from the measurement data themselves without prior knowledge. This paper extends these methods for non-perpendicular incidence, where the polarization of the radiation becomes important. Furthermore, modifications considering effects of surface roughness of the coating are introduced. The new methods are verified using measurement data of a sample of Inconel steel coated with yttria-stabilized zirconia (YSZ) and with COMSOL simulations of the measurement setup. To validate the thickness measurements, scanning electron microscopy (SEM) images of the layer structure are used. The results show good agreement with an average error of 1% for the simulation data and under 4% for the experimental data compared to reference measurements.
Open AccessTHz-TDS Reflection Measurement of Coating Thicknesses at Non-Perpendicular Incidence: Experiment and Simulation
Time-domain spectroscopy (TDS) in the terahertz (THz) frequency range is gaining in importance in nondestructive testing of dielectric materials. One application is the layer thickness measurement of a coating layer. To determine the thickness from the measurement data, the refractive index of the coating layer must be known in the surveyed frequency range. For perpendicular incidence of the radiation, methods exist to extract the refractive index from the measurement data themselves without prior knowledge. This paper extends these methods for non-perpendicular incidence, where the polarization of the radiation becomes important. Furthermore, modifications considering effects of surface roughness of the coating are introduced. The new methods are verified using measurement data of a sample of Inconel steel coated with yttria-stabilized zirconia (YSZ) and with COMSOL simulations of the measurement setup. To validate the thickness measurements, scanning electron microscopy (SEM) images of the layer structure are used. The results show good agreement with an average error of 1% for the simulation data and under 4% for the experimental data compared to reference measurements.
- Open Access
- 7 February 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (4) , 1508
Ultrasonic Imaging of Thick Carbon Fiber Reinforced Polymers through Pulse-Compression-Based Phased Array
The use of pulse-compression in ultrasonic non-destructive testing has assured, in various applications, a significant improvement in the signal-to-noise ratio. In this work, the technique is combined with linear phased array to improve the sensitivity and resolution in the ultrasonic imaging of highly attenuating and scattering materials. A series of tests were conducted on a 60 mm thick carbon fiber reinforced polymer benchmark sample with known defects using a custom-made pulse-compression-based phased array system. Sector scan and total focusing method images of the sample were obtained with the developed system and were compared with those reconstructed by using a commercial pulse-echo phased array system. While an almost identical sensitivity was found in the near field, the pulse-compression-based system surpassed the standard one in the far-field producing a more accurate imaging of the deepest defects and of the backwall of the sample.
- 7 February 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (4) , 1508
Open AccessUltrasonic Imaging of Thick Carbon Fiber Reinforced Polymers through Pulse-Compression-Based Phased Array
The use of pulse-compression in ultrasonic non-destructive testing has assured, in various applications, a significant improvement in the signal-to-noise ratio. In this work, the technique is combined with linear phased array to improve the sensitivity and resolution in the ultrasonic imaging of highly attenuating and scattering materials. A series of tests were conducted on a 60 mm thick carbon fiber reinforced polymer benchmark sample with known defects using a custom-made pulse-compression-based phased array system. Sector scan and total focusing method images of the sample were obtained with the developed system and were compared with those reconstructed by using a commercial pulse-echo phased array system. While an almost identical sensitivity was found in the near field, the pulse-compression-based system surpassed the standard one in the far-field producing a more accurate imaging of the deepest defects and of the backwall of the sample.
- 11 September 2015
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 82 (9) , 440-450
Simulative Ultraschall-Untersuchung von Pitch-Catch-Messanordnungen für große zylindrische Stahl-Prüflinge und gradientenbasierte Bildgebung
Zusammenfassung: Große zylindrische Stahlprüflinge werden mittels der Methode der finiten Differenzen im Zeitbereich (engl. finite differences in time domain, FDTD) simulativ untersucht. Dabei werden Pitch-Catch-Messanordnungen verwendet. Es werden zwei Bildgebungsansätze vorgestellt: ersterer basiert auf dem Imaging Principle nach Claerbout, letzterer basiert auf gradientenbasierter Optimierung eines Zielfunktionals.
- 11 September 2015
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 82 (9) , 440-450
Simulative Ultraschall-Untersuchung von Pitch-Catch-Messanordnungen für große zylindrische Stahl-Prüflinge und gradientenbasierte Bildgebung
Zusammenfassung: Große zylindrische Stahlprüflinge werden mittels der Methode der finiten Differenzen im Zeitbereich (engl. finite differences in time domain, FDTD) simulativ untersucht. Dabei werden Pitch-Catch-Messanordnungen verwendet. Es werden zwei Bildgebungsansätze vorgestellt: ersterer basiert auf dem Imaging Principle nach Claerbout, letzterer basiert auf gradientenbasierter Optimierung eines Zielfunktionals.
- 1 June 2013
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 84 (6) , 064902
Fusion of visual and infrared thermography images for advanced assessment in non-destructive testing
For better evaluation of infrared measurements in non-destructive testing, especially for objects with complex geometry or small dimensions, it is beneficial to combine with the same viewing angle an image of a camera in the visible range with the image of an infrared camera. In the hybrid camera developed by us, a beam splitter is used which combines the visible and the infrared wavelength regions under the same viewing angle to form a hybrid image. The applications of this new technique range from the localization and the verification of false indications in non-destructive testing applications to the retrieval of 3D surface information with a hybrid picture as texture with defect indications and the filtering of laser markings displayed in the IR image to area and process monitoring.
- 1 June 2013
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 84 (6) , 064902
Fusion of visual and infrared thermography images for advanced assessment in non-destructive testing
For better evaluation of infrared measurements in non-destructive testing, especially for objects with complex geometry or small dimensions, it is beneficial to combine with the same viewing angle an image of a camera in the visible range with the image of an infrared camera. In the hybrid camera developed by us, a beam splitter is used which combines the visible and the infrared wavelength regions under the same viewing angle to form a hybrid image. The applications of this new technique range from the localization and the verification of false indications in non-destructive testing applications to the retrieval of 3D surface information with a hybrid picture as texture with defect indications and the filtering of laser markings displayed in the IR image to area and process monitoring.
- 18 May 2012
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1430 (1) , 475
Combining spectral material properties in the infrared and the visible spectral range for qualification and nondestructive evaluation of components
The spectral selective thermography with infrared filters can be used to determine or to distinguish materials such as contaminations on a metallic component. With additional visual information, the indications by the IR signal can be selectively accentuated or suppressed for easier evaluation of passive and active thermography measurements. For flash thermography the detected IR signal between 3.4 and 5.1 μm is analyzed with regard to the spectral material information. The presented hybrid camera uses beam overlapping to obtain combined images of both in the infrared and the visual range.
- 18 May 2012
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1430 (1) , 475
Combining spectral material properties in the infrared and the visible spectral range for qualification and nondestructive evaluation of components
The spectral selective thermography with infrared filters can be used to determine or to distinguish materials such as contaminations on a metallic component. With additional visual information, the indications by the IR signal can be selectively accentuated or suppressed for easier evaluation of passive and active thermography measurements. For flash thermography the detected IR signal between 3.4 and 5.1 μm is analyzed with regard to the spectral material information. The presented hybrid camera uses beam overlapping to obtain combined images of both in the infrared and the visual range.