ITIbrahim Farag Tahoun

Ibrahim Farag Tahoun

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ibrahim Farag Tahoun has a total of 68 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Development of a primary reference material for the analysis of BTEX and chlorobenzenes in environmental samples

    by Ibrahim F Tahoun, Mohamed Adly Gab-Allah

    Benzene, toluene, ethylbenzene, and xylene (BTEX) and chlorobenzenes are measured in all environments as part of world official pollution control programs. The health impact of these analytes increased the relevance of the validity and comparability of the measurement results. Therefore, equipment performance, implementation of test methods, and accuracy of results need to be verified through internal and external quality control programs. Herein, a new certified reference material (CRM) for benzene, toluene, chlorobenzene, ethylbenzene, o-xylene, 1,2-dichlorobenzene, 1,3-dichlorobenzene and 1,4-dichlorobenzene, and m, p-xylene has been produced and characterized by an approach that is metrologically valid and complies with ISO 17034:2016 and ISO 33405:2024 standards. The reference material was prepared gravimetrically and certified values were calculated based on masses of pure components. Homogeneity results proved that the between-ampule heterogeneity was negligible in comparison with the method precision. The stability of the material was evaluated for both long-term storage and dispatch and no measurable loss of analytes was observed within one year period. The developed certified reference material with small uncertainties values will support regulatory bodies, environmental protection agencies, and testing laboratories in their efforts to improve the quality of motoring results and compliance with regulations.

  • Optimization and Validation of Reversed Phase Ion-Pair Liquid Chromatographic Method for Accurate Determination of Nitrate in High Saline Seawater

    by Ibrahim Farag Tahoun, Eman Adel Rend, Ebtesam Abd ElHameed Shehab

    An accurate method for the determination of low concentrations of nitrate in high-saline seawater is now well optimized and validated. The method is based on using reversed-phase ion-pair liquid chromatography with diode-array detection for accurate determination of nitrate in high-saline seawater without interference from highly dominant chloride and sulfate anions. The method showed satisfactory precision (ranging from 5.8% to 9.5%), linearity, and detection limits, and its trueness was confirmed by participation in the international comparisons of CCQM K-161 with seven national metrology institutes. The key comparison and spiking showed recovery rates between 90% and 110%. The validation results confirm the applicability of the optimized method for detecting very low concentrations of nitrate in high-saline seawater.


  • CCQM-K161 "Anions in Seawater"

    by Chao Jingbo, Ma Liandi, Shi Naijie, Li Yunqiao, Chen Yan, Dong Lijie, Zhou Yuanjing, Patricia Grinberg, Zoltan Mester, Enea Pagliano, et al.

    Main text: Anions or nutrients in seawater are very important targets for oceanographic research and environmental monitoring of contaminations. Quantification of minor and trace anions in seawater has always been a challenge for the extremely high salinity, disparate levels of analyte and matrix ions, and even need to be measured at levels close to the detection limits of the method performance. Evidence of successful participation in formal, relevant international comparisons is needed to support calibration and measurement capability claims (CMCs) made by the national metrology institutes (NMIs) and designated institutes (DIs). The CCQM-K161 Anions in Seawater was organized by the Inorganic Analysis Working Group (IAWG) of the Consultative Committee for Amount of Substance: Metrology in Chemistry and Biology (CCQM) to assess the abilities of the NMIs and DIs for the accurate determination of minor and trace anions in seawater. The measurands covered chloride (16 mg/g-25 mg/g), sulfate (1 mg/g-4 mg/g), bromide (30 mg/kg-100 mg/kg), nitrate (1 mg/kg-5 mg/kg) and phosphate (60 µg/kg-300 µg/kg). Twelve national metrology institutes and designated institutes participated in this key comparison. Participants were requested to evaluate the mass fractions, expressed in mg/g for chloride and sulfate, mg/kg for bromide and nitrate, and µg/kg for phosphate (as phosphorus) in a mixed natural seawater that was spiked with the phosphate. A variety of techniques including isotope dilution inductively coupled plasma mass spectrometry (IDMS), isotope dilution gas chromatography-mass spectrometry (ID-GC-MS), ion chromatography (IC), UV visible spectrophotometry (UV-Vis), flow injection analysis (FIA) was used by the participants for the determination. The NIST Decision Tree was used to assign the KCRV estimate and to calculate the degrees of equivalence of each participants following the IAWG Guidance on Using NIST Decision Tree for Comparison Reporting from 30 June 2023. Successful participation in CCQM-K161 demonstrates measurement capabilities for determination of anions in seawater. Considering the IAWG Core Capability Matrix, this material falls into the matrix challenge called 'High salts content', which corresponds to the CCQM amount-of-substance category sea water, and so will support CMCs for the anions in a mass fraction range from 60 µg/kg to 25 mg/g. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).


  • Development of ledipasvir and sofosbuvir pure certified reference materials for improving quality of pharmaceutical analysis

    by Ibrahim F. Tahoun, Mohamed A. Gab-Allah

    The pure materials play a pivotal role in controlling the quality of pharmaceutical products, ensuring comparability and metrological traceability of test results, and performance evaluation of measuring instruments. Herein, the purity characterization of chronic hepatitis C virus sofosbuvir and ledipasvir pharmaceuticals was established based on the assessment of mass fractions of potential impurities in the material including heavy metals, residual solvents, and water content, as well as structurally-related organic impurities. The combined estimate of these impurities by mass balance approach led to indirect purity determination of sofosbuvir and ledipasvir materials. The impurities mass fractions in each material were assigned by validated chromatographic methods, Karl Fisher titrator, and inductively coupled plasma-based method. The certified purity values of sofosbuvir and ledipasvir and their corresponding expanded uncertainties (k =2.0 at 95% CL) were found (99.79±0.03) %, (99.69±0.04) %, respectively. The developed certified reference materials (CRMs) with small uncertainty values will support pharmaceutical testing laboratories in their efforts to maintain and improve the quality of results and provide them with high-order CRMs for the accurate determination of both analytes in raw materials and finished products


  • Characterization of low-density polyethylene reference material for melt flow rate by collaboration of NIS and a network of competent laboratories

    by Hesham Moustafa, Ibrahim F. Tahoun, Ahmed I. Abou-Kandil, Nabila A. Darwish

    The growth rate of plastic manufacturing all over the world and in the middle east as oil producing countries increased the rate of thermoplastics production and the needs of reference materials (RMs) for use in performance evaluation of measuring instruments and ensuring validity of measurement results. This article was focused on the preparation of RM based melt mass-flow rate from low-density polyethylene (LDPE) according to ISO 1133-1 standard. The characterization was evaluated from around 10% of prepared units, then the samples were distributed to a network of collaborating laboratories in order to ensure the validity of the RM production process. The value of melt mass-flow rate of LDPE was determined to be 19.51 g/10 min under a temperature of 190℃ and a load of 2.16 kg with expanded uncertainty 0.38 at 95% confidence level. The obtained values were confirmed from the data reported by the network of collaborating laboratories.


  • Preparation and value assignment of parabens and phenoxyethanol in cosmetic cream certified reference material

    by Ibrahim Tahoun, Mohamed .Gab-Allah, Eman Rend

    A new certified reference material has been developed by National Institute of Standards according to ISO Guides 30-35 and ISO 17034:2016 for preservatives in cosmetic cream to be used for validation and verification of analytical methods, proficiency testing and as internal quality control sample for quality assurance in testing laboratories. The material was prepared gravimetrically and mass fraction of each analyte was confirmed be validated liquid chromatographic method. The material along with analytes homogeneity and stability were completely evaluated. The certified value of phenoxyethanol, methyl, ethyl, propyl, and butyl paraben and their corresponding expanded uncertainties (k = 2.0) were found (0.500±0.017) %, (0.150±0.006) %, (0.051±0.003) %, (0.101±0.004) % and (0.050 ±0.003) %, respectively.


  • Preparation of Quality Control Material for Assuring Quality of Electrical Conductivity Measurements in Soil

    by Ibrahim Farag Tahoun, Adel Shehata, Randa Nasr

    Accurate and reliable analytical results of soil have become essential tool for understanding salinity and limiting factors affecting agricultural productivity. Reliability of results depends mainly on the existence and quality of reference materials which are considered as crucial tools for validation and verification of the analytical process and assuring quality of measurement results. The National Metrology Institute of Egypt [NIS] is striving to set up the national standards to ensure all measurement results are traceable to the international system of unit (SI). NIS starting development of a series of soil reference materials to meet Egyptian requirements and customer demands. This article describes the production process of the soil reference material characterized for electrical conductivity from processing to value assignment. Characterization, homogeneity and stability studies of the material were carried out according to ISO guides 34, 35 and 80. The measurement results were statistically analyzed to calculate assigned values. The assigned value and expanded uncertainty for EC1:1 and EC1:5 methods were found 1234 ±58 µS/cm and 973 ±52 µS/cm, respectively.

  • Development and Validation of Simple Reversed Phase Method for Separation and Quantification of Tocopherols in Edible Oils

    by Ibrahim Tahoun, Adel Shehata

    A simple reversed phase high performance liquid chromatography method for separation and quantification of tocopherols in edible oils has been developed and validated. In the developed method C18 column was used and a mixture of isopropanol and water was used as mobile phase to achieve baseline separation of all isomers. Tocopherols were separated completely with very good peak resolution in 45 minutes and were detected using diode array detector. No pretreatment of the samples was needed, except dilution in ethanol. The validation measurements showed that the developed method was suitable for quantification of tocopherols in edible oils.