Adel Shehata
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Adel Shehata has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Abdulrahman Alaskar
Department of Chemistry, National Measurement and Calibration Center, Saudi Standards, Metrology and Quality Organization (SASO), Riyadh 11471, Kingdom of Saudi Arabia
6 shared publications - Abdullah S. AlOwaysi
Department of Chemistry, National Measurement and Calibration Center, Saudi Standards, Metrology and Quality Organization (SASO), Riyadh 11471, Kingdom of Saudi Arabia
2 shared publications Abdulrahman Alaskar
Saudi Stand Metrol & Qual Org SASO, Natl Measurement & Calibrat Ctr NMCC, Chem Dept, Riyadh, Saudi Arabia
2 shared publicationsAbdulrahman Alzahrani
Saudi Stand Metrol & Qual Org SASO, Natl Measurement & Calibrat Ctr NMCC, Chem Dept, Riyadh, Saudi Arabia
2 shared publications- Abdulrahman M. Alzahrani
Department of Chemistry, National Measurement and Calibration Center (NMCC), Saudi Standards, Metrology and Quality Organization (SASO), Riyadh, Kingdom of Saudi Arabia
2 shared publications - Fahad A. Alkharraa
Department of Chemistry, National Measurement and Calibration Center (NMCC), Saudi Standards, Metrology and Quality Organization (SASO), Riyadh, Kingdom of Saudi Arabia
2 shared publications
Latest Publications
- Open Access
- 9 October 2026
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 38 (10) , 2559-2566
Preparation and Certification of Propane in Nitrogen as Reference Material for Ensuring Traceability of Hydrocarbon Emission Measurements
Propane in nitrogen (C3H8/N2) gas mixtures are widely used as calibration standards for hydrocarbon measurements in environmental monitoring, energy production and industrial process control. Five C3H8/N2 gas mixtures, covering the range of 804.8148-12053.8148 µmol/mol, were gravimetrically prepared according to ISO 6142 using a two-step dilution approach with high-purity propane and nitrogen. The prepared mixtures were validated by gas chromatography with flame ionization detection (GC-FID) in accordance with ISO 6143. The GC-FID results showed good agreement with the gravimetric values, confirming the validity of the preparation method. The certified values determined by gravimetry were established for 4 mixtures (B, C, D, E) as 12053.81 ± 97.49, 9013.23 ± 78.11, 5998.011 ± 57.72 and 2987.29 ± 66.91 µmol/mol, respectively. The mole fraction of the mixture F, 804.81 ± 35.97 µmol/mol was considered an information value since it was associated with large uncertainty of 7.016%. The performance of the produced certified reference materials (CRMs) was checked by using them to calibrate the GC-FID, then measure a CRM sample of 8010 µmol/mol as an unknown. The precision (%RSD) and accuracy of the measured results were found to be 0.12% and 99.75%, respectively. These results confirm that the prepared C3H8/N2 mixtures meet the criteria for certified reference materials and are suitable as calibrants for hydrocarbon emission measurement instruments in industrial gas analysis and environmental monitoring.
- 9 October 2026
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 38 (10) , 2559-2566
Open AccessPreparation and Certification of Propane in Nitrogen as Reference Material for Ensuring Traceability of Hydrocarbon Emission Measurements
Propane in nitrogen (C3H8/N2) gas mixtures are widely used as calibration standards for hydrocarbon measurements in environmental monitoring, energy production and industrial process control. Five C3H8/N2 gas mixtures, covering the range of 804.8148-12053.8148 µmol/mol, were gravimetrically prepared according to ISO 6142 using a two-step dilution approach with high-purity propane and nitrogen. The prepared mixtures were validated by gas chromatography with flame ionization detection (GC-FID) in accordance with ISO 6143. The GC-FID results showed good agreement with the gravimetric values, confirming the validity of the preparation method. The certified values determined by gravimetry were established for 4 mixtures (B, C, D, E) as 12053.81 ± 97.49, 9013.23 ± 78.11, 5998.011 ± 57.72 and 2987.29 ± 66.91 µmol/mol, respectively. The mole fraction of the mixture F, 804.81 ± 35.97 µmol/mol was considered an information value since it was associated with large uncertainty of 7.016%. The performance of the produced certified reference materials (CRMs) was checked by using them to calibrate the GC-FID, then measure a CRM sample of 8010 µmol/mol as an unknown. The precision (%RSD) and accuracy of the measured results were found to be 0.12% and 99.75%, respectively. These results confirm that the prepared C3H8/N2 mixtures meet the criteria for certified reference materials and are suitable as calibrants for hydrocarbon emission measurement instruments in industrial gas analysis and environmental monitoring.
- 26 December 2025
- Published by ACG Publications in Journal of Chemical Metrology
- Vol. 19 (2) , 245-259
Development of a quality control material for conductivity measurements in food and environmental applications
The accuracy and reliability of conductivity measurements in analytical laboratories depend significantly on the availability of quality control materials. This study addresses the preparation, homogeneity, stability and characterization of a potassium chloride (KCl) quality control material (QCM) of 1414 µS/cm based on ISO/TR 33402. OIML R-56 does not contain this conductivity value as a secondary standard, so the mass of KCl required to prepare such a solution was experimentally defined. The conductivity measurements were carried out at 25 °C using a conductivity meter calibrated by a CRM produced by the the Slovak Institute of Metrology (SMU), a signatory to the mutual recognition arrangement (MRA) of the International Committee of Weights and Measures (CIPM). The homogeneity study was carried out in accordance with ISO 33405 using 10% of the batch bottles and the analysis of variance (ANOVA) showed that the QCM batch is homogeneous. The short-term stability was carried out over 4 weeks storage time at 4°C and 40°C and the isochronous measurements showed no significant deviations over time. The characterization of the QCM along three days showed that, its conductivity was 1414.11 µS/cm. The uncertainty associated with the conductivity measurements was assessed based on the requirements of the Guide to the expression of uncertainty in measurement (ISO GUM) and the EURACHEM/CITAC Guide, CG4 (Quantifying uncertainty in analytical measurement). It was found to be 23.10 µS/cm or 1.63%. A control chart was developed using the prepared QCM and the measured values remained within the control limits over the control time of six weeks. The prepared KCl QCM will be useful for use in quality control and instrumental validation in food, drug and environmental conductivity testing.
- 26 December 2025
- Published by ACG Publications in Journal of Chemical Metrology
- Vol. 19 (2) , 245-259
Development of a quality control material for conductivity measurements in food and environmental applications
The accuracy and reliability of conductivity measurements in analytical laboratories depend significantly on the availability of quality control materials. This study addresses the preparation, homogeneity, stability and characterization of a potassium chloride (KCl) quality control material (QCM) of 1414 µS/cm based on ISO/TR 33402. OIML R-56 does not contain this conductivity value as a secondary standard, so the mass of KCl required to prepare such a solution was experimentally defined. The conductivity measurements were carried out at 25 °C using a conductivity meter calibrated by a CRM produced by the the Slovak Institute of Metrology (SMU), a signatory to the mutual recognition arrangement (MRA) of the International Committee of Weights and Measures (CIPM). The homogeneity study was carried out in accordance with ISO 33405 using 10% of the batch bottles and the analysis of variance (ANOVA) showed that the QCM batch is homogeneous. The short-term stability was carried out over 4 weeks storage time at 4°C and 40°C and the isochronous measurements showed no significant deviations over time. The characterization of the QCM along three days showed that, its conductivity was 1414.11 µS/cm. The uncertainty associated with the conductivity measurements was assessed based on the requirements of the Guide to the expression of uncertainty in measurement (ISO GUM) and the EURACHEM/CITAC Guide, CG4 (Quantifying uncertainty in analytical measurement). It was found to be 23.10 µS/cm or 1.63%. A control chart was developed using the prepared QCM and the measured values remained within the control limits over the control time of six weeks. The prepared KCl QCM will be useful for use in quality control and instrumental validation in food, drug and environmental conductivity testing.
- Open Access
- 30 September 2025
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 37 (10) , 2500-2506
Development and Validation of a GC-ECD Method for the Determination of Trifluralin in Acetonitrile with Uncertainty Estimation
The use of trifluralin herbicide has raised concerns due to its persistence in the environment and potential toxicological impacts on human health and ecosystems. The aim of this study was to develop and validate a simple and reliable method for determining trifluralin residues in acetonitrile using gas chromatography with an electron capture detector (GC-ECD). The method was developed using internal standard calibration and validated in accordance with international guidelines. Validation parameters included LOD, LOQ, selectivity, linearity, precision, accuracy (recovery and bias) and measurement uncertainty. The method demonstrated high selectivity with no interfering peaks at the trifluralin retention time. A strong linear relationship was observed in the concentration range of 4-11 µg/g with a correlation coefficient (R2) of 0.9996. The precision, expressed as relative standard deviation (%RSD) was found 3.84% across all levels. Recovery values ranged from 98.45% to 100.06%, with % bias between 0.06% and 1.55% confirming the method accuracy. The expanded uncertainty was estimated to be 9.86% primarily influenced by sample and internal standard (IS) peak areas. The validated GC-ECD method provides a reliable, precise and accurate approach for quantifying trifluralin residues in environmental and food samples. It is suitable for routine monitoring, regulatory applications and risk assessments in agricultural and environmental contexts.
- 30 September 2025
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 37 (10) , 2500-2506
Open AccessDevelopment and Validation of a GC-ECD Method for the Determination of Trifluralin in Acetonitrile with Uncertainty Estimation
The use of trifluralin herbicide has raised concerns due to its persistence in the environment and potential toxicological impacts on human health and ecosystems. The aim of this study was to develop and validate a simple and reliable method for determining trifluralin residues in acetonitrile using gas chromatography with an electron capture detector (GC-ECD). The method was developed using internal standard calibration and validated in accordance with international guidelines. Validation parameters included LOD, LOQ, selectivity, linearity, precision, accuracy (recovery and bias) and measurement uncertainty. The method demonstrated high selectivity with no interfering peaks at the trifluralin retention time. A strong linear relationship was observed in the concentration range of 4-11 µg/g with a correlation coefficient (R2) of 0.9996. The precision, expressed as relative standard deviation (%RSD) was found 3.84% across all levels. Recovery values ranged from 98.45% to 100.06%, with % bias between 0.06% and 1.55% confirming the method accuracy. The expanded uncertainty was estimated to be 9.86% primarily influenced by sample and internal standard (IS) peak areas. The validated GC-ECD method provides a reliable, precise and accurate approach for quantifying trifluralin residues in environmental and food samples. It is suitable for routine monitoring, regulatory applications and risk assessments in agricultural and environmental contexts.
- 26 June 2025
- Published by ACG Publications in Journal of Chemical Metrology
- Vol. 19 (1) , 23-33
Development of a new multipoint calibration method and uncertainty of a high-performance spectrophotometer for ensuring accurate water turbidity measurements
Turbidity is a key indicator of water quality influencing the proliferation of protozoa. Accurate turbidity measurements are essential for optimal water resource management and river basin planning particularly in contexts where water quality is a primary concern. Turbidity of unknown samples is usually measured by turbidity meters or spectrophotometers under one point calibration at 860 nm in the UV region. This creates a measurement limitation since the turbidity of an unknown sample should be the same or quite near turbidity to the CRM. To overcome this limitation, this work describes a new multi-point calibration method for a high-performance Lambda Spectrophotometer equipped with Gallium-Indium-Arsenic (GaInAs) detector. The calibration was carried out using three turbidity standards of 100, 500 and 1000 Nephelometric Turbidity Unit NTU which were measured in the NIR region at 1070, 1372 and 1569 nm respectively. The absorbance of each standard was measured 10 times and the CRM turbidly values were plotted against the measured absorbance values. A very good linear relationship was obtained with R2 of 1 and the linear calibration function can be used to obtain the turbidity of an unknown sample measured at each of the three used wavelengths. The type A and type B calibration uncertainty sources were quantified according to ISO GUM and the calibration results were found to be 100.14± 0.47, 498.03±1.60 and 997.81±3.54 NTU. The method has been applied for measuring turbidity of a CRM sample with a small error of approximately 1%. The developed calibration method will be useful for analytical laboratories serving the water quality in the environmental and industrial sectors.
- 26 June 2025
- Published by ACG Publications in Journal of Chemical Metrology
- Vol. 19 (1) , 23-33
Development of a new multipoint calibration method and uncertainty of a high-performance spectrophotometer for ensuring accurate water turbidity measurements
Turbidity is a key indicator of water quality influencing the proliferation of protozoa. Accurate turbidity measurements are essential for optimal water resource management and river basin planning particularly in contexts where water quality is a primary concern. Turbidity of unknown samples is usually measured by turbidity meters or spectrophotometers under one point calibration at 860 nm in the UV region. This creates a measurement limitation since the turbidity of an unknown sample should be the same or quite near turbidity to the CRM. To overcome this limitation, this work describes a new multi-point calibration method for a high-performance Lambda Spectrophotometer equipped with Gallium-Indium-Arsenic (GaInAs) detector. The calibration was carried out using three turbidity standards of 100, 500 and 1000 Nephelometric Turbidity Unit NTU which were measured in the NIR region at 1070, 1372 and 1569 nm respectively. The absorbance of each standard was measured 10 times and the CRM turbidly values were plotted against the measured absorbance values. A very good linear relationship was obtained with R2 of 1 and the linear calibration function can be used to obtain the turbidity of an unknown sample measured at each of the three used wavelengths. The type A and type B calibration uncertainty sources were quantified according to ISO GUM and the calibration results were found to be 100.14± 0.47, 498.03±1.60 and 997.81±3.54 NTU. The method has been applied for measuring turbidity of a CRM sample with a small error of approximately 1%. The developed calibration method will be useful for analytical laboratories serving the water quality in the environmental and industrial sectors.
- Open Access
- 10 June 2025
- Published by IMEKO International Measurement Confederation in ACTA IMEKO
- Vol. 14 (2) , 1-8
Calibration of an unloaded laboratory oven and the associated uncertainty of measurements
The aim of this research was to describe the calibration of an unloaded laboratory oven used for drying textiles samples from respiration at (37 ± 2) °C and the detailed associated uncertainty of measurements. The calibration was performed at three temperature points (35 °C, 37 °C and 40 °C) in accordance with the DKD-R 5-7:2018 guidelines. The entire calibration system including the nine calibrated Pt100 temperature probes and the multimeter that reads temperature in °C was interfaced with a PC running a LabVIEW program for data acquisition and analysis. The temperature drift, inhomogeneity, instability and the calibration uncertainty were assessed. A small temperature drift of 0.3 °C over 48 hours at 40 °C was found. The temperature inhomogeneity expressed as the maximum absolute difference between the reference location and the other locations, Max │Tref - Ti│ was found well below the acceptable accuracy of ± 2 °C. The temporal instability expressed as the maximum difference between the average and the temperature of each Pt100, Max │T̅ - Ti│ was also smaller than the acceptance limit, ± 2 °C of the textile test. The expanded uncertainty did not exceed ± 1.24 °C indicating a good oven calibration. This investigation revealed that the calibrated oven maintains good temperature drift, homogeneity and stability making it suitable for reliable textile testing.
- 10 June 2025
- Published by IMEKO International Measurement Confederation in ACTA IMEKO
- Vol. 14 (2) , 1-8
Open AccessCalibration of an unloaded laboratory oven and the associated uncertainty of measurements
The aim of this research was to describe the calibration of an unloaded laboratory oven used for drying textiles samples from respiration at (37 ± 2) °C and the detailed associated uncertainty of measurements. The calibration was performed at three temperature points (35 °C, 37 °C and 40 °C) in accordance with the DKD-R 5-7:2018 guidelines. The entire calibration system including the nine calibrated Pt100 temperature probes and the multimeter that reads temperature in °C was interfaced with a PC running a LabVIEW program for data acquisition and analysis. The temperature drift, inhomogeneity, instability and the calibration uncertainty were assessed. A small temperature drift of 0.3 °C over 48 hours at 40 °C was found. The temperature inhomogeneity expressed as the maximum absolute difference between the reference location and the other locations, Max │Tref - Ti│ was found well below the acceptable accuracy of ± 2 °C. The temporal instability expressed as the maximum difference between the average and the temperature of each Pt100, Max │T̅ - Ti│ was also smaller than the acceptance limit, ± 2 °C of the textile test. The expanded uncertainty did not exceed ± 1.24 °C indicating a good oven calibration. This investigation revealed that the calibrated oven maintains good temperature drift, homogeneity and stability making it suitable for reliable textile testing.
- Open Access
- 10 March 2025
- Published by IMEKO International Measurement Confederation in ACTA IMEKO
- Vol. 14 (1) , 1-7
Development of quality control materials from CO/N2 gas mixture based on ISO Guide 80 for controlled environmental measurementsements
This study presents the development of quality control materials (QCMs) for monitoring carbon monoxide (CO) concentrations using a validated gas chromatography-thermal conductivity detector (GC-TCD) method. The QCMs were prepared gravimetrically according to ISO 6142, using a three-step dilution process from pure CO and nitrogen. The resulting QCMs have a target amount fraction of 1000 µmol/mol (ppm). To assess homogeneity, the QCMs were analyzed using a validated GC-TCD system calibrated with certified reference materials (CRMs). One-way analysis of variances (ANOVA) revealed excellent homogeneity among the QCMs. Stability was evaluated based on previous studies of similar CO/N2 mixtures demonstrating long-term stability. Characterization of the QCMs by GC-TCD confirmed an amount fraction of 1004.65 µmol/mol, which was found in good compatibility of the gravimetric value. A quality control chart with upper and lower control limits was implemented for five months, validating the successful preparation of the QCMs. This research offers a reliable approach for laboratories to develop in-house QCMs for CO measurements, ensuring the accuracy and traceability of their results to the (SI) units.
- 10 March 2025
- Published by IMEKO International Measurement Confederation in ACTA IMEKO
- Vol. 14 (1) , 1-7
Open AccessDevelopment of quality control materials from CO/N2 gas mixture based on ISO Guide 80 for controlled environmental measurementsements
This study presents the development of quality control materials (QCMs) for monitoring carbon monoxide (CO) concentrations using a validated gas chromatography-thermal conductivity detector (GC-TCD) method. The QCMs were prepared gravimetrically according to ISO 6142, using a three-step dilution process from pure CO and nitrogen. The resulting QCMs have a target amount fraction of 1000 µmol/mol (ppm). To assess homogeneity, the QCMs were analyzed using a validated GC-TCD system calibrated with certified reference materials (CRMs). One-way analysis of variances (ANOVA) revealed excellent homogeneity among the QCMs. Stability was evaluated based on previous studies of similar CO/N2 mixtures demonstrating long-term stability. Characterization of the QCMs by GC-TCD confirmed an amount fraction of 1004.65 µmol/mol, which was found in good compatibility of the gravimetric value. A quality control chart with upper and lower control limits was implemented for five months, validating the successful preparation of the QCMs. This research offers a reliable approach for laboratories to develop in-house QCMs for CO measurements, ensuring the accuracy and traceability of their results to the (SI) units.
- 26 December 2024
- Published by ACG Publications in Journal of Chemical Metrology
- No. 2,p. 185-197
Patulin reference material certified by RP-HPLC-UV and gravimetry for food safety analysis
- 26 December 2024
- Published by ACG Publications in Journal of Chemical Metrology
- No. 2,p. 185-197
Patulin reference material certified by RP-HPLC-UV and gravimetry for food safety analysis
- 9 May 2024
- Published by ACG Publications in Records of Agricultural and Food Chemistry
- No. 3,p. 1-9
Validation of a UV-VIS-NIR Spectrophotometric Method for Determination of Sodium Benzoate in Water
- 9 May 2024
- Published by ACG Publications in Records of Agricultural and Food Chemistry
- No. 3,p. 1-9
Validation of a UV-VIS-NIR Spectrophotometric Method for Determination of Sodium Benzoate in Water
- 24 February 2024
- Published by ACG Publications in Records of Agricultural and Food Chemistry
- No. i,p. 1
Importance of the Uncertainty of Measurements in Food Analysis
- 24 February 2024
- Published by ACG Publications in Records of Agricultural and Food Chemistry
- No. i,p. 1
Importance of the Uncertainty of Measurements in Food Analysis
- 29 June 2023
- Published by ACG Publications in Journal of Chemical Metrology
- Vol. 17 (1)
Certification of buffer solutions reference materials using Baucke cell for supporting the quality of pH measurements
The need for certified pH reference materials to support the traceability claims and quality of the daily large volume of pH measurements is very strong. In this work, three batches of buffer solutions were prepared, and their pH values were certified in accordance with the IUPAC Recommendation 2002. The first batch was prepared from potassium tetraoxalate (dihydrate) and disodium oxalate to provide pH4 and the second batch was prepared from disodium hydrogen phosphate and potassium dihydrogen phosphate to provide pH7. The third batch was prepared from sodium hydrogen carbonate and sodium carbonate to provide pH10. Every batch was homogenized by mechanical shaking for one night and bottled into 50 HDPE bottles, each is 250 mL. A number of bottles were systematically selected for homogeneity, stability and characterization studies of the buffer reference materials. These studies were carried out in accordance with the requirements of ISO 17034 and ISO Guide 35 using Baucke cell. The pH values 4, 7 and 10 of the secondary buffers were restandardized with regard to the pH values 4, 7 and 10 of the primary buffers produced by the Slovak National Metrology Institute, SMU. The results obtained showed that the produced buffer RMs were homogeneous and stable enough and their certified pH values were found 4.001±0.019, 7.005±0.015 and 10.002±0.023. These CRMs will be very useful as calibrants and as PT samples for analytical laboratories performing pH measurements in various fields.
- 29 June 2023
- Published by ACG Publications in Journal of Chemical Metrology
- Vol. 17 (1)
Certification of buffer solutions reference materials using Baucke cell for supporting the quality of pH measurements
The need for certified pH reference materials to support the traceability claims and quality of the daily large volume of pH measurements is very strong. In this work, three batches of buffer solutions were prepared, and their pH values were certified in accordance with the IUPAC Recommendation 2002. The first batch was prepared from potassium tetraoxalate (dihydrate) and disodium oxalate to provide pH4 and the second batch was prepared from disodium hydrogen phosphate and potassium dihydrogen phosphate to provide pH7. The third batch was prepared from sodium hydrogen carbonate and sodium carbonate to provide pH10. Every batch was homogenized by mechanical shaking for one night and bottled into 50 HDPE bottles, each is 250 mL. A number of bottles were systematically selected for homogeneity, stability and characterization studies of the buffer reference materials. These studies were carried out in accordance with the requirements of ISO 17034 and ISO Guide 35 using Baucke cell. The pH values 4, 7 and 10 of the secondary buffers were restandardized with regard to the pH values 4, 7 and 10 of the primary buffers produced by the Slovak National Metrology Institute, SMU. The results obtained showed that the produced buffer RMs were homogeneous and stable enough and their certified pH values were found 4.001±0.019, 7.005±0.015 and 10.002±0.023. These CRMs will be very useful as calibrants and as PT samples for analytical laboratories performing pH measurements in various fields.