ASAnuj Sharma

Anuj Sharma

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Anuj Sharma has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Low peak power multiband spokes pulses for B1+ inhomogeneity‐compensated simultaneous multislice excitation in high field MRI

    by Anuj Sharma, Roland Bammer, V. Andrew Stenger, William A Grissom

    Purpose: To design low peak and integrated power simultaneous multislice excitation radiofrequency pulses with transmit field inhomogeneity compensation in high field MRI.Theory and Methods: The “interleaved greedy and local optimization” algorithm for small‐tip‐angle spokes pulses is extended to design multiband (MB) spokes pulses that simultaneously excite multiple slices, with independent spokes weight optimization for each slice. The peak power of the pulses is controlled using a slice phase optimization technique. Simulations were performed at 7T to compare the peak power of optimized MB spokes pulses to unoptimized pulses, and to compare the proposed slice‐independent spokes weight optimization to a joint approach. In vivo experiments were performed at 7T to validate the pulse's function and compare them to conventional MB pulses.Results: Simulations showed that the peak power‐minimized pulses had lower peak power than unregularized and integrated power‐regularized pulses, and that the slice‐independent spokes weight optimization consistently produced lower flip angle inhomogeneity and lower peak and integrated power pulses. In the brain imaging experiments, the MB spokes pulses showed significant improvement in excitation flip angle and subsequently signal homogeneity compared to conventional MB pulses.Conclusion: The proposed MB spokes pulses improve flip angle homogeneity in simultaneous multislice acquisitions at ultrahigh field, with minimal increase in integrated and peak radiofrequency power. Magn Reson Med 74:747–755, 2015.


  • Open Access

    Highly‐accelerated Bloch‐Siegert mapping using joint autocalibrated parallel image reconstruction

    by Anuj Sharma, Sasidhar Tadanki, Marcin Jankiewicz, William A Grissom

    Purpose To reconstruct accurate single- and multichannel Bloch–Siegert transmit radiofrequency () field maps from highly accelerated data. Theory and Methods The approach is based on the fact that the -to-phase encoding pulse for each transmit coil and off-resonance frequency applies a unique phase shift to the same underlying image. This enables joint reconstruction of all images in a Bloch–Siegert acquisition from an augmented set of virtual receive coils, using any autocalibrated parallel imaging reconstruction method. Results Simulations with an eight channel transmit/receive array head coil at 7T show that accurate maps can be produced at acceleration factors of 16× and 6× for Cartesian and spiral sampling, respectively. A phantom experiment with a six channel transverse electromagnetic (TEM) transceive array coil allowed accurate reconstruction at 16× acceleration. 7T in vivo experiments performed using 32 channel receive and two-channel transmit coils further demonstrate the proposed method's ability to produce high-quality maps at accelerations of 32× and 8× for Cartesian and spiral trajectories, respectively. Reconstruction accuracy is improved using disjoint k-space sampling patterns between acquisitions. Conclusion The proposed approach allows high acceleration factors in Bloch–Siegert mapping and can significantly reduce the scan time requirements for mapping the fields of transmit arrays. Magn Reson Med 71:1470–1477, 2014.