STSasidhar Tadanki

Sasidhar Tadanki

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sasidhar Tadanki has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Jay Moore

    Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, TN 37232-2310, United States; Department of Radiology and Radiological Sciences, Vanderbilt University, Nashville, TN 37232-2310, United States

    2 shared publications
  • Kevin W. Waddell

    Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, TN 37232-2310, United States; Department of Physics and Astronomy, Vanderbilt University, Nashville, TN 37232-2310, United States; Department of Radiology and Radiological Sciences, Vanderbilt University, Nashville, TN 37232-2310, United States

    2 shared publications
  • Anuj Sharma

    Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee, USA

    1 shared publication
  • Edward Brian Welch

    Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee, USA

    1 shared publication
  • John C. Gore

    Vanderbilt University Institute of Imaging Science, Nashville, TN, USA

    1 shared publication
  • Marcin Jankiewicz

    Department of Physics and Astronomy Vanderbilt University 37235 Nashville TN USA

    1 shared publication

Latest Publications

  • Open Access

    Prospective real-time head motion correction using inductively coupled wireless NMR probes

    by Saikat Sengupta, Sasidhar Tadanki, John C. Gore, E. Brian Welch

    Purpose Head motion continues to be a major source of artifacts and data quality degradation in MRI. The goal of this work was to develop and demonstrate a novel technique for prospective, 6 degrees of freedom (6DOF) rigid body motion estimation and real‐time motion correction using inductively coupled wireless nuclear magnetic resonance (NMR) probe markers. Methods Three wireless probes that are inductively coupled with the scanner's RF setup serve as fiducials on the subject's head. A 12‐ms linear navigator module is interleaved with the imaging sequence for head position estimation, and scan geometry is updated in real time for motion compensation. Flip angle amplification in the markers allows the use of extremely small navigator flip angles (∼1°). A novel algorithm is presented to identify marker positions in the absence of marker specific receive channels. Motion correction is demonstrated in high resolution 2D and 3D gradient recalled echo experiments in a phantom and humans. Results Significant improvement of image quality is demonstrated in phantoms and human volunteers under different motion conditions. Conclusion A novel real‐time 6DOF head motion correction technique based on wireless NMR probes is demonstrated in high resolution imaging at 7 Tesla. Magn Reson Med 72:971–985, 2014.


  • Open Access

    Highly‐accelerated Bloch‐Siegert mapping using joint autocalibrated parallel image reconstruction

    by Anuj Sharma, Sasidhar Tadanki, Marcin Jankiewicz, William A Grissom

    Purpose To reconstruct accurate single- and multichannel Bloch–Siegert transmit radiofrequency () field maps from highly accelerated data. Theory and Methods The approach is based on the fact that the -to-phase encoding pulse for each transmit coil and off-resonance frequency applies a unique phase shift to the same underlying image. This enables joint reconstruction of all images in a Bloch–Siegert acquisition from an augmented set of virtual receive coils, using any autocalibrated parallel imaging reconstruction method. Results Simulations with an eight channel transmit/receive array head coil at 7T show that accurate maps can be produced at acceleration factors of 16× and 6× for Cartesian and spiral sampling, respectively. A phantom experiment with a six channel transverse electromagnetic (TEM) transceive array coil allowed accurate reconstruction at 16× acceleration. 7T in vivo experiments performed using 32 channel receive and two-channel transmit coils further demonstrate the proposed method's ability to produce high-quality maps at accelerations of 32× and 8× for Cartesian and spiral trajectories, respectively. Reconstruction accuracy is improved using disjoint k-space sampling patterns between acquisitions. Conclusion The proposed approach allows high acceleration factors in Bloch–Siegert mapping and can significantly reduce the scan time requirements for mapping the fields of transmit arrays. Magn Reson Med 71:1470–1477, 2014.