Mohammad Fazel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mohammad Fazel has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
- Dietmar Christian Florian Wieland
Institute of Metallic Biomaterials, Helmholtz Zentrum Hereon, Geesthacht, Germany
3 shared publications M. Ramazani
Department of Materials Engineering, Malek Ashtar University of Technology, Isfahan, Iran
3 shared publicationsM.R. Garsivaz Jazi
3 shared publications- Regine Willumeit-Römer
Institute of Metallic Biomaterials, Helmholtz Zentrum Hereon, Geesthacht, Germany
3 shared publications S. Bahramzadeh
Department of Materials Engineering, University of Tehran, Teharn, Iran
3 shared publications- Vasil M. Garamus
Helmholtz-Zentrum Hereon, Max-Planck-Street 1, 21502 Geesthacht, Germany
3 shared publications
Latest Publications
- Open Access
- 26 July 2025
- Published by MDPI AG in Journal of Composites Science
- Vol. 9 (8) , 396
Three-Dimensional Distribution of Titanium Hydrides After Degradation of Magnesium/Titanium Hybrid Implant Material—A Study by X-Ray Diffraction Contrast Tomography
Hybrid implants composed of magnesium and titanium are a promising direction in orthopaedics, as these implants combine the stability of titanium with the biological activity of magnesium. These partly soluble implants require careful investigation, as the degradation of magnesium releases hydrogen, which can enter the Ti matrix and thus alter the mechanical properties. To investigate this scenario and quantify the hydrogen uptake along with its structural impacts, we employed inert gas fusion, scanning electron microscopy, X-ray diffraction, and a combination of synchrotron absorption and X-ray diffraction tomography. These techniques enabled us to investigate the concentration and distribution of hydrogen and the formation of hydrides in the samples. Titanium hydride formation was observed in a region approximately 120 µm away from the titanium surface and correlates with the amount of absorbed hydrogen. We speculate that the degradation of magnesium at the magnesium/titanium implant interface leads to the penetration of hydrogen due to a combination of electrochemical and gaseous charging.
- 26 July 2025
- Published by MDPI AG in Journal of Composites Science
- Vol. 9 (8) , 396
Open AccessThree-Dimensional Distribution of Titanium Hydrides After Degradation of Magnesium/Titanium Hybrid Implant Material—A Study by X-Ray Diffraction Contrast Tomography
Hybrid implants composed of magnesium and titanium are a promising direction in orthopaedics, as these implants combine the stability of titanium with the biological activity of magnesium. These partly soluble implants require careful investigation, as the degradation of magnesium releases hydrogen, which can enter the Ti matrix and thus alter the mechanical properties. To investigate this scenario and quantify the hydrogen uptake along with its structural impacts, we employed inert gas fusion, scanning electron microscopy, X-ray diffraction, and a combination of synchrotron absorption and X-ray diffraction tomography. These techniques enabled us to investigate the concentration and distribution of hydrogen and the formation of hydrides in the samples. Titanium hydride formation was observed in a region approximately 120 µm away from the titanium surface and correlates with the amount of absorbed hydrogen. We speculate that the degradation of magnesium at the magnesium/titanium implant interface leads to the penetration of hydrogen due to a combination of electrochemical and gaseous charging.
- Open Access
- 1 August 2024
- Published by KEAI Publishing in Journal of Magnesium and Alloys
- Vol. 12 (8) , 3142-3158
Mg-Ti hybrid joints: Surface modification, corrosion studies and 3D-pore investigation using synchrotron-based microtomography
- 1 August 2024
- Published by KEAI Publishing in Journal of Magnesium and Alloys
- Vol. 12 (8) , 3142-3158
Open AccessMg-Ti hybrid joints: Surface modification, corrosion studies and 3D-pore investigation using synchrotron-based microtomography
- Open Access
- 1 July 2024
- Published by KEAI Publishing in Journal of Magnesium and Alloys
- Vol. 12 (7) , 2741-2755
Improvement of corrosion resistance of PEO coated dissimilar Ti/Mg0.6Ca couple
- 1 July 2024
- Published by KEAI Publishing in Journal of Magnesium and Alloys
- Vol. 12 (7) , 2741-2755
Open AccessImprovement of corrosion resistance of PEO coated dissimilar Ti/Mg0.6Ca couple
- 18 September 2020
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 5 (38) , 24186-24194
Microstructure and Corrosion Characterization of a MgO/Hydroxyapatite Bilayer Coating by Plasma Electrolytic Oxidation Coupled with Flame Spraying on a Mg Alloy
Thermally sprayed hydroxyapatite coatings are one of the main strategies to improve the bioactivation of metal implants. However, the naturally low corrosion resistance of these coatings is the main challenge for their use. In this study, plasma electrolytic oxidation (PEO) was used to create an intermediate layer. The anodization process was used for comparison. According to the polarization curves, the PEO layer was more effective than the anodized layer in reducing the corrosion current density (Icorr of 0.05 × 10–9 A/cm2 vs Icorr of 0.05 A/cm2). The results of electrochemical impedance spectroscopy showed higher resistance of the sample with a PEO interlayer than that of the sample with an anodized interlayer. The results of the hydrogen evolution test revealed that the PEO layer as a middle layer served as the main barrier for reducing the magnesium corrosion rate, especially during the initial immersion time.
- 18 September 2020
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 5 (38) , 24186-24194
Microstructure and Corrosion Characterization of a MgO/Hydroxyapatite Bilayer Coating by Plasma Electrolytic Oxidation Coupled with Flame Spraying on a Mg Alloy
Thermally sprayed hydroxyapatite coatings are one of the main strategies to improve the bioactivation of metal implants. However, the naturally low corrosion resistance of these coatings is the main challenge for their use. In this study, plasma electrolytic oxidation (PEO) was used to create an intermediate layer. The anodization process was used for comparison. According to the polarization curves, the PEO layer was more effective than the anodized layer in reducing the corrosion current density (Icorr of 0.05 × 10–9 A/cm2 vs Icorr of 0.05 A/cm2). The results of electrochemical impedance spectroscopy showed higher resistance of the sample with a PEO interlayer than that of the sample with an anodized interlayer. The results of the hydrogen evolution test revealed that the PEO layer as a middle layer served as the main barrier for reducing the magnesium corrosion rate, especially during the initial immersion time.
- 1 September 2020
- Published by Elsevier in Biotribology
- Vol. 23
Enhanced corrosion and tribocorrosion behavior of Ti6Al4V alloy by auto–sealed micro-arc oxidation layers
- 1 September 2020
- Published by Elsevier in Biotribology
- Vol. 23
Enhanced corrosion and tribocorrosion behavior of Ti6Al4V alloy by auto–sealed micro-arc oxidation layers
- 1 September 2019
- Published by Elsevier in Surface and Coatings Technology
- Vol. 374, 222-231
Influence of hydrothermal treatment on the surface characteristics and electrochemical behavior of Ti-6Al-4V bio-functionalized through plasma electrolytic oxidation
- 1 September 2019
- Published by Elsevier in Surface and Coatings Technology
- Vol. 374, 222-231
Influence of hydrothermal treatment on the surface characteristics and electrochemical behavior of Ti-6Al-4V bio-functionalized through plasma electrolytic oxidation
- 6 April 2018
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 10 (17) , 15281-15287
Improvement of Corrosion and Tribocorrosion Behavior of Pure Titanium by Subzero Anodic Spark Oxidation
The present investigation reports corrosion and tribocorrosion behavior of anodic spark oxidation (ASO) coatings formed at 20 and −10 °C. Despite the numerous open pores on the layers formed at 20 °C , the plasma discharged channels were blocked on the surfaces of the subzero ASO coatings. According to polarization curves, the samples treated at −10 °C showed a significant increase in the corrosion resistance (jcorr of 0.75 nA cm–2). Electrochemical impedance spectroscopy experiments illustrated lower capacitance and higher resistance of both inner and porous layers formed at low temperature. Subzero ASO coatings also demonstrated the lowest overall open circuit potential drop in tribocorrosion studies.
- 6 April 2018
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 10 (17) , 15281-15287
Improvement of Corrosion and Tribocorrosion Behavior of Pure Titanium by Subzero Anodic Spark Oxidation
The present investigation reports corrosion and tribocorrosion behavior of anodic spark oxidation (ASO) coatings formed at 20 and −10 °C. Despite the numerous open pores on the layers formed at 20 °C , the plasma discharged channels were blocked on the surfaces of the subzero ASO coatings. According to polarization curves, the samples treated at −10 °C showed a significant increase in the corrosion resistance (jcorr of 0.75 nA cm–2). Electrochemical impedance spectroscopy experiments illustrated lower capacitance and higher resistance of both inner and porous layers formed at low temperature. Subzero ASO coatings also demonstrated the lowest overall open circuit potential drop in tribocorrosion studies.
- 8 April 2016
- Published by Taylor & Francis in Materials at High Temperatures
- Vol. 33 (3) , 219-224
The influence of temperature on tribological behaviour of Ni-SiC Electrodeposited coating
In this article, the Electrodeposition of a Ni-SiC composite coating, which is mostly used as wear resistant coating in many applications, such as engine cylinders, combustion engines and casting moulds, was carried out from a sulphamate bath. Both mechanical and ultrasonic stirrers were used simultaneously during the process. Due to the working temperature of coating in the mentioned applications, the wear tests were carried out from 25 to 300 °C by pin-on-disk method and the high temperature tribological behaviour of the coating was investigated. Based on the results obtained from the wear tests, the Ni-SiC coating has low friction coefficient (0.36–0.42) and wear weight loss (0.7–2 mg) values at 25 and 100 °C. But, by increasing the temperature to 200–300 °C, which is near to the working temperature of many applications, the friction coefficient and wear weight loss values significantly increased.
- 8 April 2016
- Published by Taylor & Francis in Materials at High Temperatures
- Vol. 33 (3) , 219-224
The influence of temperature on tribological behaviour of Ni-SiC Electrodeposited coating
In this article, the Electrodeposition of a Ni-SiC composite coating, which is mostly used as wear resistant coating in many applications, such as engine cylinders, combustion engines and casting moulds, was carried out from a sulphamate bath. Both mechanical and ultrasonic stirrers were used simultaneously during the process. Due to the working temperature of coating in the mentioned applications, the wear tests were carried out from 25 to 300 °C by pin-on-disk method and the high temperature tribological behaviour of the coating was investigated. Based on the results obtained from the wear tests, the Ni-SiC coating has low friction coefficient (0.36–0.42) and wear weight loss (0.7–2 mg) values at 25 and 100 °C. But, by increasing the temperature to 200–300 °C, which is near to the working temperature of many applications, the friction coefficient and wear weight loss values significantly increased.
- Open Access
- 1 May 2015
- Published by CASRP: Center of Advanced Scientific Research and Publications in Journal of Advanced Materials In Engineering
- Vol. 34 (1) , 105-121
Influence of Gr and MoS2 Particles on High Temperature Tribological Properties of Ni-SiC Composite Coating
Journal of Advanced Materials in Engineering (Esteghlal) مجله علمی پژوهشی مواد پیشرفته در مهندسی
- 1 May 2015
- Published by CASRP: Center of Advanced Scientific Research and Publications in Journal of Advanced Materials In Engineering
- Vol. 34 (1) , 105-121
Open AccessInfluence of Gr and MoS2 Particles on High Temperature Tribological Properties of Ni-SiC Composite Coating