Huayong Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Huayong Zhao has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Colin P. Garner
Wolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, Leicestershire LE11 3TU, UK
2 shared publications - Neville Rebelo
Loughborough University
2 shared publications R. Poole
2 shared publicationsZ. Zhou
2 shared publicationsA. Williams
Department of Mechanical Engineering, University of Chester, Chester CH1 4BJ, UK
1 shared publication- Andrew Morgan Williams
Loughborough Univ
1 shared publication
Latest Publications
- Open Access
- 2 May 2024
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 228
Rate-limiting factors in thin-film evaporative heat transfer processes
- 2 May 2024
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 228
Open AccessRate-limiting factors in thin-film evaporative heat transfer processes
- Open Access
Rate-limiting factors in thin-film evaporative heat transfer processes
In this paper, we present a theoretical study aimed at investigating the rate-limiting factors in thin-film evaporative heat transfer processes, considering the finite-rate evaporation kinetics. The problems of evaporation of a flat thin-film in either pure vapours or vapour-inert-gas mixtures are analysed based on the non-dimensionalised macroscopic transport equations for continuum fluids, coupled with out-of-equilibrium kinetic boundary conditions. Both the full numerical solutions and asymptotic analytical solutions at slow evaporation limit are provided and applied to analyse thin water film evaporation. Existing solutions, assuming negligible heat transfer in the gas domain, or negligible temperature jump across the non-equilibrium kinetic layer, or more boldly a thermodynamically equilibrial interface (i.e. its temperature is at the saturation temperature), can be fully recovered from the more general solutions presented here. Our results show that while these assumptions hold in special cases, they can lead to significant errors in many conditions, especially when the film thickness $δ$ is reduced to a few micrometers or thinner. We show that the conventional views that the rate-limiting factors in thin-film evaporative heat transfer is either the heat diffusion through the liquid film or the mass transfer in the gas domain only apply to thick film. As $δ$ decreases to a few micrometer or smaller, the interfacial thermal resistance due to the evaporation kinetics can be on the same orders of magnitude as the thermal resistance in the liquid film. The analysis also allows us to compare the heat transfer processes during the evaporation of a thin-film in pure vapours to those in inert gases, providing deeper insight into the effectiveness of various strategies for exploring the evaporation process in practical thermal management.Open AccessRate-limiting factors in thin-film evaporative heat transfer processes
In this paper, we present a theoretical study aimed at investigating the rate-limiting factors in thin-film evaporative heat transfer processes, considering the finite-rate evaporation kinetics. The problems of evaporation of a flat thin-film in either pure vapours or vapour-inert-gas mixtures are analysed based on the non-dimensionalised macroscopic transport equations for continuum fluids, coupled with out-of-equilibrium kinetic boundary conditions. Both the full numerical solutions and asymptotic analytical solutions at slow evaporation limit are provided and applied to analyse thin water film evaporation. Existing solutions, assuming negligible heat transfer in the gas domain, or negligible temperature jump across the non-equilibrium kinetic layer, or more boldly a thermodynamically equilibrial interface (i.e. its temperature is at the saturation temperature), can be fully recovered from the more general solutions presented here. Our results show that while these assumptions hold in special cases, they can lead to significant errors in many conditions, especially when the film thickness $δ$ is reduced to a few micrometers or thinner. We show that the conventional views that the rate-limiting factors in thin-film evaporative heat transfer is either the heat diffusion through the liquid film or the mass transfer in the gas domain only apply to thick film. As $δ$ decreases to a few micrometer or smaller, the interfacial thermal resistance due to the evaporation kinetics can be on the same orders of magnitude as the thermal resistance in the liquid film. The analysis also allows us to compare the heat transfer processes during the evaporation of a thin-film in pure vapours to those in inert gases, providing deeper insight into the effectiveness of various strategies for exploring the evaporation process in practical thermal management. - Open Access
- 1 March 2023
- Published by Cambridge University Press (CUP) in Journal of Fluid Mechanics
- Vol. 958, A18
Droplet evaporation in inert gases
A general mixed kinetic-diffusion boundary condition is formulated to account for the out-of-equilibrium kinetics in the Knudsen layer. The mixed boundary condition is used to investigate the problem of quasi-steady evaporation of a droplet in an infinite domain containing inert gases. The widely adopted local thermodynamic equilibrium assumption is found to be the limiting case of infinitely large kinetic Péclet number ${{Pe}_k}$ , and it introduces significant error for ${{Pe}_k} \leqslant O(10)$ , which corresponds to a typical droplet radius $a$ of a few micrometres or smaller. When compared with experimental data, solutions based on the mixed boundary condition, which take into account the temperature jump across the Knudsen layer, better predict the time evolution of $a$ than the classical $D^2$ -law (i.e. $a^2 \propto t$ , where $t$ denotes time). In the slow evaporation limit, an analytical solution is obtained by linearising the full formulation about the equilibrium condition, which shows that the $D^2$ -law can be recovered only in the large ${{Pe}_k}$ limit. For small ${{Pe}_k}$ , where the process is dominated by kinetics, a linear relation, i.e. $a \propto t$ , emerges. When the gas phase density approaches the liquid density (e.g. at high-pressure or low-temperature conditions), the increase in the chemical potential of the liquid phase due to the presence of inert gases needs to be accounted for when formulating the mixed boundary condition, an effect largely ignored in the literature so far.- 1 March 2023
- Published by Cambridge University Press (CUP) in Journal of Fluid Mechanics
- Vol. 958, A18
Open AccessDroplet evaporation in inert gases
A general mixed kinetic-diffusion boundary condition is formulated to account for the out-of-equilibrium kinetics in the Knudsen layer. The mixed boundary condition is used to investigate the problem of quasi-steady evaporation of a droplet in an infinite domain containing inert gases. The widely adopted local thermodynamic equilibrium assumption is found to be the limiting case of infinitely large kinetic Péclet number ${{Pe}_k}$ , and it introduces significant error for ${{Pe}_k} \leqslant O(10)$ , which corresponds to a typical droplet radius $a$ of a few micrometres or smaller. When compared with experimental data, solutions based on the mixed boundary condition, which take into account the temperature jump across the Knudsen layer, better predict the time evolution of $a$ than the classical $D^2$ -law (i.e. $a^2 \propto t$ , where $t$ denotes time). In the slow evaporation limit, an analytical solution is obtained by linearising the full formulation about the equilibrium condition, which shows that the $D^2$ -law can be recovered only in the large ${{Pe}_k}$ limit. For small ${{Pe}_k}$ , where the process is dominated by kinetics, a linear relation, i.e. $a \propto t$ , emerges. When the gas phase density approaches the liquid density (e.g. at high-pressure or low-temperature conditions), the increase in the chemical potential of the liquid phase due to the presence of inert gases needs to be accounted for when formulating the mixed boundary condition, an effect largely ignored in the literature so far. - Open Access
The Effect of Heat Exchange Fluid Composition on the Performance of a Liquid Nitrogen Engine System
It has been proven that performance gains in liquid nitrogen (LN2) engine systems, generating simultaneous cooling and auxiliary power, can be achieved through integration of a dedicated heat exchange fluid (HEF) circuit. The novel, HEF enhanced LN2 engine system can be utilised as an optimised hybrid solution for commercial refrigeration trucks. Although the benefits arising from HEF addition have been researched, there are no articles investigating the effect of changing the HEF composition on engine performance. This article reports a detailed experimental investigation on the performance of a novel, HEF enhanced LN2 engine system. The key contribution of the current study is the knowledge generated from investigating the impact of different HEF compositions on the engine performance under different HEF temperatures, N2 inlet conditions and engine speeds. The HEF composition was varied through changing the water content in the mixture. A thermodynamic model based on an idealised cycle was used to assist interpretation of the experimental results and assess the potential of the proposed engine architecture. The experimental study demonstrated up to 42.5% brake thermal efficiency, up to 2.67 kW of brake power and up to 174 kJ/kg specific energy, which were higher than previously published figures for LN2 engine systems. A reduction in the HEF water content was found to generally increase the engine power output at a HEF temperature of 30 °C. However, at a HEF temperature of 60 °C, the impact of HEF composition was found to be minor and nonmonotonic. The thermodynamic model predicted the upper and lower limits of the measured indicated power and indicated thermal efficiency with acceptable accuracy.
Open AccessThe Effect of Heat Exchange Fluid Composition on the Performance of a Liquid Nitrogen Engine System
It has been proven that performance gains in liquid nitrogen (LN2) engine systems, generating simultaneous cooling and auxiliary power, can be achieved through integration of a dedicated heat exchange fluid (HEF) circuit. The novel, HEF enhanced LN2 engine system can be utilised as an optimised hybrid solution for commercial refrigeration trucks. Although the benefits arising from HEF addition have been researched, there are no articles investigating the effect of changing the HEF composition on engine performance. This article reports a detailed experimental investigation on the performance of a novel, HEF enhanced LN2 engine system. The key contribution of the current study is the knowledge generated from investigating the impact of different HEF compositions on the engine performance under different HEF temperatures, N2 inlet conditions and engine speeds. The HEF composition was varied through changing the water content in the mixture. A thermodynamic model based on an idealised cycle was used to assist interpretation of the experimental results and assess the potential of the proposed engine architecture. The experimental study demonstrated up to 42.5% brake thermal efficiency, up to 2.67 kW of brake power and up to 174 kJ/kg specific energy, which were higher than previously published figures for LN2 engine systems. A reduction in the HEF water content was found to generally increase the engine power output at a HEF temperature of 30 °C. However, at a HEF temperature of 60 °C, the impact of HEF composition was found to be minor and nonmonotonic. The thermodynamic model predicted the upper and lower limits of the measured indicated power and indicated thermal efficiency with acceptable accuracy.
- 22 August 2019
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 143, 118575
Evaporation of liquid nitrogen droplets in superheated immiscible liquids
- 22 August 2019
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 143, 118575
Evaporation of liquid nitrogen droplets in superheated immiscible liquids
- Open Access
- 22 May 2018
- Published by Wiley in Journal of Heat Transfer
- Vol. 140 (9) , 091502
Corrections for the Hydrodynamic Instability-Based Critical Heat Flux Models in Pool Boiling—Effects of Viscosity and Heating Surface Size
This paper presents corrections for existing hydrodynamic instability-based critical heat flux (CHF) models in pool boiling by taking into account the effect of the viscosity, geometry and size of the liquid–vapor interface. Based on the existing literature, the Kelvin–Helmholtz (KH) theory, used by the most commonly adopted CHF models, can lead to noticeable errors when predicting the instability conditions. The errors are mainly due to the inaccuracy of the inviscid flow assumptions and the oversimplification of the interface geometry. In addition, the literature suggests the most unstable condition predicted by the viscous correction for viscous potential flow (VCVPF) theory for the cylindrical interfaces best match the observed air column breakup conditions in water. In this paper, the most unstable instability conditions predicted by the VCVPF theory are used to correct the existing CHF models. The comparison between the existing and corrected CHF models suggests that the corrected models always predict a higher CHF value. In addition, the corrected Zuber model predicts similar CHF value to the Lienhard and Dhir model. The comparison with experimental data suggests that the correction to the Zuber model can increase its prediction accuracy in most cases, but not necessary for the Lienhard and Dhir model. When compared to experimental CHF data for boiling cryogens at different pressures, the corrected CHF models are consistently more accurate than the original CHF models.
- 22 May 2018
- Published by Wiley in Journal of Heat Transfer
- Vol. 140 (9) , 091502
Open AccessCorrections for the Hydrodynamic Instability-Based Critical Heat Flux Models in Pool Boiling—Effects of Viscosity and Heating Surface Size
This paper presents corrections for existing hydrodynamic instability-based critical heat flux (CHF) models in pool boiling by taking into account the effect of the viscosity, geometry and size of the liquid–vapor interface. Based on the existing literature, the Kelvin–Helmholtz (KH) theory, used by the most commonly adopted CHF models, can lead to noticeable errors when predicting the instability conditions. The errors are mainly due to the inaccuracy of the inviscid flow assumptions and the oversimplification of the interface geometry. In addition, the literature suggests the most unstable condition predicted by the viscous correction for viscous potential flow (VCVPF) theory for the cylindrical interfaces best match the observed air column breakup conditions in water. In this paper, the most unstable instability conditions predicted by the VCVPF theory are used to correct the existing CHF models. The comparison between the existing and corrected CHF models suggests that the corrected models always predict a higher CHF value. In addition, the corrected Zuber model predicts similar CHF value to the Lienhard and Dhir model. The comparison with experimental data suggests that the correction to the Zuber model can increase its prediction accuracy in most cases, but not necessary for the Lienhard and Dhir model. When compared to experimental CHF data for boiling cryogens at different pressures, the corrected CHF models are consistently more accurate than the original CHF models.
- Open Access
- 24 April 2017
- Published by ASME International in Journal of Fluids Engineering
- Vol. 139 (7) , 071104
On the Measurement and Modeling of High-Pressure Flows in Poppet Valves Under Steady-State and Transient Conditions
Flow coefficients of intake valves and port combinations were determined experimentally for a compressed nitrogen engine under steady-state and dynamic flow conditions for inlet pressures up to 3.2 MPa. Variable valve timing was combined with an indexed parked piston cylinder unit for testing valve flows at different cylinder volumes while maintaining realistic in-cylinder transient pressure profiles by simply using a fixed area outlet orifice. A one-dimensional modeling approach describing three-dimensional valve flow characteristics has been developed by the use of variable flow coefficients that take into account the propagation of flow jets and their boundaries as a function of downstream/upstream pressure ratios. The results obtained for the dynamic flow cases were compared with steady-state results for the cylinder to inlet port pressure ratios ranges from 0.18 to 0.83. The deviation of flow coefficients for both cases is discussed using pulsatile flow theory. The key findings include the followings: (1) for a given valve lift, the steady-state flow coefficients fall by up to 21% with increasing cylinder/manifold pressure ratios within the measured range given above and (2) transient flow coefficients deviated from those measured for the steady-state flow as the valve lift increases beyond a critical value of approximately 0.5 mm. The deviation can be due to the insufficient time of the development of steady-state boundary layers, which can be quantified by the instantaneous Womersley number defined by using the transient hydraulic diameter. We show that it is possible to predict deviations of the transient valve flow from the steady-state measurements alone.
- 24 April 2017
- Published by ASME International in Journal of Fluids Engineering
- Vol. 139 (7) , 071104
Open AccessOn the Measurement and Modeling of High-Pressure Flows in Poppet Valves Under Steady-State and Transient Conditions
Flow coefficients of intake valves and port combinations were determined experimentally for a compressed nitrogen engine under steady-state and dynamic flow conditions for inlet pressures up to 3.2 MPa. Variable valve timing was combined with an indexed parked piston cylinder unit for testing valve flows at different cylinder volumes while maintaining realistic in-cylinder transient pressure profiles by simply using a fixed area outlet orifice. A one-dimensional modeling approach describing three-dimensional valve flow characteristics has been developed by the use of variable flow coefficients that take into account the propagation of flow jets and their boundaries as a function of downstream/upstream pressure ratios. The results obtained for the dynamic flow cases were compared with steady-state results for the cylinder to inlet port pressure ratios ranges from 0.18 to 0.83. The deviation of flow coefficients for both cases is discussed using pulsatile flow theory. The key findings include the followings: (1) for a given valve lift, the steady-state flow coefficients fall by up to 21% with increasing cylinder/manifold pressure ratios within the measured range given above and (2) transient flow coefficients deviated from those measured for the steady-state flow as the valve lift increases beyond a critical value of approximately 0.5 mm. The deviation can be due to the insufficient time of the development of steady-state boundary layers, which can be quantified by the instantaneous Womersley number defined by using the transient hydraulic diameter. We show that it is possible to predict deviations of the transient valve flow from the steady-state measurements alone.
- Open Access
- 12 February 2014
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 28 (3) , 2144-2151
Investigation of the Soot Formation in Ethylene Laminar Diffusion Flames When Diluted with Helium or Supplemented by Hydrogen
- 12 February 2014
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 28 (3) , 2144-2151
Open AccessInvestigation of the Soot Formation in Ethylene Laminar Diffusion Flames When Diluted with Helium or Supplemented by Hydrogen