Harish K. Malhotra
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Harish K. Malhotra has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Anurag K. Singh
Department of Radiation Medicine, Roswell Park Comprehensive Cancer Center, Buffalo, New York
4 shared publications - Matthew B. Podgorsak
Department of Radiation Medicine, Roswell Park Cancer Institute, Buffalo NY, USA
4 shared publications - Jorge A. Gomez-Suescun
Department of Radiation Medicine, Roswell Park Comprehensive Cancer Center, Buffalo, NY 14203, USA
3 shared publications - Simon Fung-Kee-Fung
Department of Radiation Medicine, Roswell Park Comprehensive Cancer Center, Buffalo, New York
3 shared publications - Sung Jun Ma
Department of Radiation Oncology, The Arthur G. James Cancer Hospital and Richard J. Solove Research Institute, The Ohio State University Comprehensive Cancer Center, Columbus, OH
3 shared publications Wainwright Jaggernauth
3 shared publications
Latest Publications
- Open Access
Right Atrial Dose Is Associated with Worse Outcome in Patients Undergoing Definitive Stereotactic Body Radiation Therapy for Central Lung Tumors
The consequence of cardiac substructure irradiation in patients receiving stereotactic body radiation therapy (SBRT) is not well characterized. We reviewed the charts of patients with central lung tumors managed by definitive SBRT from June 2010–April 2019. All patients were treated with five fractions, typically either 5000 cGy (44.6%) or 5500 cGy (42.2%). Via a multi-patient atlas, fourteen cardiac substructures were autosegmented, manually reviewed and analyzed using dosimetric parameters. A total of 83 patients were included with a median follow up of 33.4 months. Univariate Cox regression analysis identified a D45% dose to the right atria and ventricle for further study. Sequential log-rank testing evaluating an association between non-cancer associated survival and D45% dose to the right atria or ventricle and association was employed, identifying candidate cutoff values of 890.3 cGy and 564.4 cGy, respectively. Kaplan–Meier analysis using the reported cutoff values found the D45% right atria constraint to be significantly associated with non-cancer associated (p ≤ 0.001) and overall survival (p ≤ 0.001) but not the right ventricle constraint. Within a multivariate model, the proposed right atria D45% cutoff remained significantly correlated with non-cancer associated survival (Hazard’s Ratio (HR) ≤ 8.5, 95% confidence interval (CI) 1.1–64.5, p ≤ 0.04) and OS (HR ≤ 6.1, 95% CI 1.0–36.8, p ≤ 0.04). In conclusion, a dose to D45% of the right atria significantly correlated with outcome and the candidate constraint of 890 cGy stratified non-cancer associated and OS. The inclusion of these findings with previously characterized relationships between proximal airway constraints and survival enhances our understanding of why centrally located tumors are high risk and potentially identifies key constraints in organ at risk prioritization.
Open AccessRight Atrial Dose Is Associated with Worse Outcome in Patients Undergoing Definitive Stereotactic Body Radiation Therapy for Central Lung Tumors
The consequence of cardiac substructure irradiation in patients receiving stereotactic body radiation therapy (SBRT) is not well characterized. We reviewed the charts of patients with central lung tumors managed by definitive SBRT from June 2010–April 2019. All patients were treated with five fractions, typically either 5000 cGy (44.6%) or 5500 cGy (42.2%). Via a multi-patient atlas, fourteen cardiac substructures were autosegmented, manually reviewed and analyzed using dosimetric parameters. A total of 83 patients were included with a median follow up of 33.4 months. Univariate Cox regression analysis identified a D45% dose to the right atria and ventricle for further study. Sequential log-rank testing evaluating an association between non-cancer associated survival and D45% dose to the right atria or ventricle and association was employed, identifying candidate cutoff values of 890.3 cGy and 564.4 cGy, respectively. Kaplan–Meier analysis using the reported cutoff values found the D45% right atria constraint to be significantly associated with non-cancer associated (p ≤ 0.001) and overall survival (p ≤ 0.001) but not the right ventricle constraint. Within a multivariate model, the proposed right atria D45% cutoff remained significantly correlated with non-cancer associated survival (Hazard’s Ratio (HR) ≤ 8.5, 95% confidence interval (CI) 1.1–64.5, p ≤ 0.04) and OS (HR ≤ 6.1, 95% CI 1.0–36.8, p ≤ 0.04). In conclusion, a dose to D45% of the right atria significantly correlated with outcome and the candidate constraint of 890 cGy stratified non-cancer associated and OS. The inclusion of these findings with previously characterized relationships between proximal airway constraints and survival enhances our understanding of why centrally located tumors are high risk and potentially identifies key constraints in organ at risk prioritization.
- Open Access
Exceeding Radiation Dose to Volume Parameters for the Proximal Airways with Stereotactic Body Radiation Therapy Is More Likely for Ultracentral Lung Tumors and Associated with Worse Outcome
The preferred radiotherapeutic approach for central (CLT) and ultracentral (UCLT) lung tumors is unclear. We assessed the toxicity and outcomes of patients with CLT and UCLT who underwent definitive five-fraction stereotactic body radiation therapy (SBRT). We reviewed the charts of patients with either CLT or UCLT managed with SBRT from June 2010–April 2019. CLT were defined as gross tumor volume (GTV) within 2 cm of either the proximal bronchial tree, trachea, mediastinum, aorta, or spinal cord. UCLT were defined as GTV abutting any of these structures. Propensity score matching was performed for gender, performance status, and history of prior lung cancer. Within this cohort of 83 patients, 43 (51.8%) patients had UCLT. The median patient age was 73.1 years with a median follow up of 29.9 months. The two most common dose fractionation schemes were 5000 cGy (44.6%) and 5500 cGy (42.2%) in five fractions. Multivariate analysis revealed UCLT to be associated with worse overall survival (OS) (HR = 1.9, p = 0.02) but not time to progression (TTP). Using propensity score match pairing, UCLT correlated with reduced non-cancer associated survival (p = 0.049) and OS (p = 0.03), but not TTP. Within the matched cohort, dosimetric study found exceeding a D4cc of 18 Gy to either the proximal bronchus (HR = 3.9, p = 0.007) or trachea (HR = 4.0, p = 0.02) was correlated with worse non-cancer associated survival. In patients undergoing five fraction SBRT, UCLT location was associated with worse non-cancer associated survival and OS, which could be secondary to excessive D4cc dose to the proximal airways.
Open AccessExceeding Radiation Dose to Volume Parameters for the Proximal Airways with Stereotactic Body Radiation Therapy Is More Likely for Ultracentral Lung Tumors and Associated with Worse Outcome
The preferred radiotherapeutic approach for central (CLT) and ultracentral (UCLT) lung tumors is unclear. We assessed the toxicity and outcomes of patients with CLT and UCLT who underwent definitive five-fraction stereotactic body radiation therapy (SBRT). We reviewed the charts of patients with either CLT or UCLT managed with SBRT from June 2010–April 2019. CLT were defined as gross tumor volume (GTV) within 2 cm of either the proximal bronchial tree, trachea, mediastinum, aorta, or spinal cord. UCLT were defined as GTV abutting any of these structures. Propensity score matching was performed for gender, performance status, and history of prior lung cancer. Within this cohort of 83 patients, 43 (51.8%) patients had UCLT. The median patient age was 73.1 years with a median follow up of 29.9 months. The two most common dose fractionation schemes were 5000 cGy (44.6%) and 5500 cGy (42.2%) in five fractions. Multivariate analysis revealed UCLT to be associated with worse overall survival (OS) (HR = 1.9, p = 0.02) but not time to progression (TTP). Using propensity score match pairing, UCLT correlated with reduced non-cancer associated survival (p = 0.049) and OS (p = 0.03), but not TTP. Within the matched cohort, dosimetric study found exceeding a D4cc of 18 Gy to either the proximal bronchus (HR = 3.9, p = 0.007) or trachea (HR = 4.0, p = 0.02) was correlated with worse non-cancer associated survival. In patients undergoing five fraction SBRT, UCLT location was associated with worse non-cancer associated survival and OS, which could be secondary to excessive D4cc dose to the proximal airways.
- Open Access
- 24 February 2021
- Published by Baishideng Publishing Group Inc. in World Journal of Clinical Oncology
- Vol. 12 (2) , 95-102
Autosegmentation of cardiac substructures in respiratory-gated, non-contrasted computed tomography images
Radiation dose to specific cardiac substructures can have a significant on treatment related morbidity and mortality, yet definition of these structures is labor intensive and not standard. Autosegmentation software may potentially address these issues, however it is unclear whether this approach can be broadly applied across different treatment planning conditions. We investigated the feasibility of autosegmentation of the cardiac substructures in four-dimensional (4D) computed tomography (CT), respiratory-gated, non-contrasted imaging. To determine whether autosegmentation can be successfully employed on 4DCT respiratory-gated, non-contrasted imaging. We included patients who underwent stereotactic body radiation therapy for inoperable, early-stage non-small cell lung cancer from 2007 to 2019. All patients were simulated via 4DCT imaging with respiratory gating without intravenous contrast. Generated structure quality was evaluated by degree of required manual edits and volume discrepancy between the autocontoured structures and its edited sister structure. Initial 17-structure cardiac atlas was generated with 20 patients followed by three successive iterations of 10 patients using MIM software. The great vessels and heart chambers were reliably autosegmented with most edits considered minor. In contrast, coronary arteries either failed to be autosegmented or the generated structures required major alterations necessitating deletion and manual definition. Similarly, the generated mitral and tricuspid valves were poor whereas the aortic and pulmonary valves required at least minor and moderate changes respectively. For the majority of subsites, the additional samples did not appear to substantially impact the quality of generated structures. Volumetric analysis between autosegmented and its manually edited sister structure yielded comparable findings to the physician-based assessment of structure quality. The use of MIM software with 30-sample subject library was found to be useful in delineating many of the heart substructures with acceptable clinical accuracy on respiratory-gated 4DCT imaging. Small volume structures, such as the coronary arteries were poorly autosegmented and require manual definition.
- 24 February 2021
- Published by Baishideng Publishing Group Inc. in World Journal of Clinical Oncology
- Vol. 12 (2) , 95-102
Open AccessAutosegmentation of cardiac substructures in respiratory-gated, non-contrasted computed tomography images
Radiation dose to specific cardiac substructures can have a significant on treatment related morbidity and mortality, yet definition of these structures is labor intensive and not standard. Autosegmentation software may potentially address these issues, however it is unclear whether this approach can be broadly applied across different treatment planning conditions. We investigated the feasibility of autosegmentation of the cardiac substructures in four-dimensional (4D) computed tomography (CT), respiratory-gated, non-contrasted imaging. To determine whether autosegmentation can be successfully employed on 4DCT respiratory-gated, non-contrasted imaging. We included patients who underwent stereotactic body radiation therapy for inoperable, early-stage non-small cell lung cancer from 2007 to 2019. All patients were simulated via 4DCT imaging with respiratory gating without intravenous contrast. Generated structure quality was evaluated by degree of required manual edits and volume discrepancy between the autocontoured structures and its edited sister structure. Initial 17-structure cardiac atlas was generated with 20 patients followed by three successive iterations of 10 patients using MIM software. The great vessels and heart chambers were reliably autosegmented with most edits considered minor. In contrast, coronary arteries either failed to be autosegmented or the generated structures required major alterations necessitating deletion and manual definition. Similarly, the generated mitral and tricuspid valves were poor whereas the aortic and pulmonary valves required at least minor and moderate changes respectively. For the majority of subsites, the additional samples did not appear to substantially impact the quality of generated structures. Volumetric analysis between autosegmented and its manually edited sister structure yielded comparable findings to the physician-based assessment of structure quality. The use of MIM software with 30-sample subject library was found to be useful in delineating many of the heart substructures with acceptable clinical accuracy on respiratory-gated 4DCT imaging. Small volume structures, such as the coronary arteries were poorly autosegmented and require manual definition.
- Open Access
Development and Validation of a Clinically Relevant Workflow for MR-Guided Volumetric Arc Therapy in a Rabbit Model of Head and Neck Cancer
There is increased interest in the use of magnetic resonance imaging (MRI) for guiding radiation therapy (RT) in the clinical setting. In this regard, preclinical studies can play an important role in understanding the added value of MRI in RT planning. In the present study, we developed and validated a clinically relevant integrated workflow for MRI-guided volumetric arc therapy (VMAT) in a VX2 rabbit neck tumor model of HNSCC. In addition to demonstrating safety and feasibility, we examined the therapeutic impact of MR-guided VMAT using a single high dose to obtain proof-of-concept and compared the response to conventional 2D-RT. Contrast-enhanced MRI (CE-MRI) provided excellent soft tissue contrast for accurate tumor segmentation for VMAT. Notably, MRI-guided RT enabled improved tumor targeting ability and minimal dose to organs at risk (OAR) compared to 2D-RT, which resulted in notable morbidity within a few weeks of RT. Our results highlight the value of integrating MRI into the workflow for VMAT for improved delineation of tumor anatomy and optimal treatment planning. The model combined with the multimodal imaging approach can serve as a valuable platform for the conduct of preclinical RT trials.
Open AccessDevelopment and Validation of a Clinically Relevant Workflow for MR-Guided Volumetric Arc Therapy in a Rabbit Model of Head and Neck Cancer
There is increased interest in the use of magnetic resonance imaging (MRI) for guiding radiation therapy (RT) in the clinical setting. In this regard, preclinical studies can play an important role in understanding the added value of MRI in RT planning. In the present study, we developed and validated a clinically relevant integrated workflow for MRI-guided volumetric arc therapy (VMAT) in a VX2 rabbit neck tumor model of HNSCC. In addition to demonstrating safety and feasibility, we examined the therapeutic impact of MR-guided VMAT using a single high dose to obtain proof-of-concept and compared the response to conventional 2D-RT. Contrast-enhanced MRI (CE-MRI) provided excellent soft tissue contrast for accurate tumor segmentation for VMAT. Notably, MRI-guided RT enabled improved tumor targeting ability and minimal dose to organs at risk (OAR) compared to 2D-RT, which resulted in notable morbidity within a few weeks of RT. Our results highlight the value of integrating MRI into the workflow for VMAT for improved delineation of tumor anatomy and optimal treatment planning. The model combined with the multimodal imaging approach can serve as a valuable platform for the conduct of preclinical RT trials.
- Open Access
- 29 November 2018
- Published by Springer Nature in BMC Cancer
- Vol. 18 (1) , 1183
A pilot study of stereotactic body radiation therapy (SBRT) after surgery for stage III non-small cell lung cancer
Standard therapy for stage III non-small cell lung cancer with chemotherapy and conventional radiation has suboptimal outcomes. We hypothesized that a combination of surgery followed by stereotactic body radiation therapy (SBRT) would be a safe alternative. Patients with stage IIIA (multistation N2) or IIIB non-small cell lung cancer were enrolled from March 2013 to December 2015. The protocol included transcervical extended mediastinal lymphadenectomy (TEMLA) followed by surgical resection, 10 Gy SBRT directed to the involved mediastinum/hilar stations and/or positive surgical margins, and adjuvant systemic therapy. Patients not suitable for anatomic lung resection were treated with 30 Gy to the primary tumor. The primary efficacy end-point was the proportion of patients with grade 3 or higher adverse events (AE) or toxicities. Of 10 patients, 7 patients underwent neoadjuvant chemotherapy. All patients had TEMLA. Nine of 10 patients underwent surgical resection. The remaining patient had an unresectable tumor and received 30 Gy SBRT to the primary lesion. All patients had post-operative SBRT. Median follow-up was 18 months. There were no perioperative mortalities. Six patients had any grade 3 AEs with no grade 4–5 AEs. Of these, 4 were not attributable to radiation. Pulmonary-related grade 3 AEs were experienced by 2 patients. There were no failures within the 10 Gy volume. Overall survival and progression-free survival rates at 2 years were 68% (90% CI 36–86) and 40% (90% CI 16–63), respectively. In carefully selected patients with locally advanced non-small cell lung cancer, combining surgery with SBRT was well tolerated with no local failure. ClinicalTrials.gov identifying number NCT01781741 . Registered February 1, 2013.
- 29 November 2018
- Published by Springer Nature in BMC Cancer
- Vol. 18 (1) , 1183
Open AccessA pilot study of stereotactic body radiation therapy (SBRT) after surgery for stage III non-small cell lung cancer
Standard therapy for stage III non-small cell lung cancer with chemotherapy and conventional radiation has suboptimal outcomes. We hypothesized that a combination of surgery followed by stereotactic body radiation therapy (SBRT) would be a safe alternative. Patients with stage IIIA (multistation N2) or IIIB non-small cell lung cancer were enrolled from March 2013 to December 2015. The protocol included transcervical extended mediastinal lymphadenectomy (TEMLA) followed by surgical resection, 10 Gy SBRT directed to the involved mediastinum/hilar stations and/or positive surgical margins, and adjuvant systemic therapy. Patients not suitable for anatomic lung resection were treated with 30 Gy to the primary tumor. The primary efficacy end-point was the proportion of patients with grade 3 or higher adverse events (AE) or toxicities. Of 10 patients, 7 patients underwent neoadjuvant chemotherapy. All patients had TEMLA. Nine of 10 patients underwent surgical resection. The remaining patient had an unresectable tumor and received 30 Gy SBRT to the primary lesion. All patients had post-operative SBRT. Median follow-up was 18 months. There were no perioperative mortalities. Six patients had any grade 3 AEs with no grade 4–5 AEs. Of these, 4 were not attributable to radiation. Pulmonary-related grade 3 AEs were experienced by 2 patients. There were no failures within the 10 Gy volume. Overall survival and progression-free survival rates at 2 years were 68% (90% CI 36–86) and 40% (90% CI 16–63), respectively. In carefully selected patients with locally advanced non-small cell lung cancer, combining surgery with SBRT was well tolerated with no local failure. ClinicalTrials.gov identifying number NCT01781741 . Registered February 1, 2013.
- Open Access
- 3 November 2017
- Published by Springer Nature in Radiation Oncology
- Vol. 12 (1) , 166
An investigation into the range dependence of target delineation strategies for stereotactic lung radiotherapy
The “gold standard” approach for defining an internal target volume (ITV) is using 10 gross tumor volume (GTV) phases delineated over the course of one respiratory cycle. However, different sites have adopted several alternative techniques which compress all temporal information into one CT image set to optimize work flow efficiency. The purpose of this study is to evaluate alternative target segmentation strategies with respect to the 10 phase gold standard. A Quasar respiratory motion phantom was employed to simulate lung tumor movement. Utilizing 4DCT imaging, a gold standard ITV was created by merging 10 GTV time resolved image sets. Four alternative planed ITV’s were compared using free breathing (FB), average intensity projection (AIP), maximum image projection (MIP), and an augmented FB (FB-Aug) set where the ITV included structures from FB plus max-inhale/exhale image sets. Statistical analysis was performed using the Dice similarity coefficient (DSC). Seventeen patients previously treated for lung SBRT were also included in this retroactive study. PTV’s derived from the FB image set are the least comparable with the 10 phase benchmark (DSC = 0.740-0.408). For phantom target motion greater than 1 cm, FB and AIP ITV delineation exceeded the 10 phase benchmark by 2% or greater, whereas MIP target segmentation was found to be consistently within 2% agreement with the gold standard (DSC > 0.878). Clinically, however, the FB-Aug method proved to be most favorable for tumor movement up to 2 cm (DSC = 0.881 ± 0.056). Our results indicate the range of tumor motion dictates the accuracy of the defined PTV with respect to the gold standard. When considering delineation efficiency relative to the 10 phase benchmark, the FB-Aug technique presents a potentially proficient and viable clinical alternative. Among various techniques used for image segmentation, a judicious balance between accuracy and efficiency is inherently required to account for tumor trajectory, range and rate of mobility.
- 3 November 2017
- Published by Springer Nature in Radiation Oncology
- Vol. 12 (1) , 166
Open AccessAn investigation into the range dependence of target delineation strategies for stereotactic lung radiotherapy
The “gold standard” approach for defining an internal target volume (ITV) is using 10 gross tumor volume (GTV) phases delineated over the course of one respiratory cycle. However, different sites have adopted several alternative techniques which compress all temporal information into one CT image set to optimize work flow efficiency. The purpose of this study is to evaluate alternative target segmentation strategies with respect to the 10 phase gold standard. A Quasar respiratory motion phantom was employed to simulate lung tumor movement. Utilizing 4DCT imaging, a gold standard ITV was created by merging 10 GTV time resolved image sets. Four alternative planed ITV’s were compared using free breathing (FB), average intensity projection (AIP), maximum image projection (MIP), and an augmented FB (FB-Aug) set where the ITV included structures from FB plus max-inhale/exhale image sets. Statistical analysis was performed using the Dice similarity coefficient (DSC). Seventeen patients previously treated for lung SBRT were also included in this retroactive study. PTV’s derived from the FB image set are the least comparable with the 10 phase benchmark (DSC = 0.740-0.408). For phantom target motion greater than 1 cm, FB and AIP ITV delineation exceeded the 10 phase benchmark by 2% or greater, whereas MIP target segmentation was found to be consistently within 2% agreement with the gold standard (DSC > 0.878). Clinically, however, the FB-Aug method proved to be most favorable for tumor movement up to 2 cm (DSC = 0.881 ± 0.056). Our results indicate the range of tumor motion dictates the accuracy of the defined PTV with respect to the gold standard. When considering delineation efficiency relative to the 10 phase benchmark, the FB-Aug technique presents a potentially proficient and viable clinical alternative. Among various techniques used for image segmentation, a judicious balance between accuracy and efficiency is inherently required to account for tumor trajectory, range and rate of mobility.
- Open Access
- 11 March 2017
- Published by sPage.direcT in Annals of Lung Cancer
- Vol. 1 (1)
A Quantitative Assessment of Lung Tumor Motion under Abdominal Compression using 4D-CT Imaging
Stereotactic Body Radiation Therapy (SBRT) has rapidly emerged as a curative procedure for early stage non-small cell lung cancer (NSCLC). The ablative hypo-fractionated radiation doses used with SBRT requires very small tumor margins, making tumor motion management very important to reduce the risk of long term morbidity. However, in conventional free-breathing situations, lung tumors can reportedly move up to 2.5 cm requiring a large treatment margin. In this clinical study, we analyzed the efficacy of using simple abdominal compression to dampen and suppress tumor motion.
- 11 March 2017
- Published by sPage.direcT in Annals of Lung Cancer
- Vol. 1 (1)
Open AccessA Quantitative Assessment of Lung Tumor Motion under Abdominal Compression using 4D-CT Imaging
Stereotactic Body Radiation Therapy (SBRT) has rapidly emerged as a curative procedure for early stage non-small cell lung cancer (NSCLC). The ablative hypo-fractionated radiation doses used with SBRT requires very small tumor margins, making tumor motion management very important to reduce the risk of long term morbidity. However, in conventional free-breathing situations, lung tumors can reportedly move up to 2.5 cm requiring a large treatment margin. In this clinical study, we analyzed the efficacy of using simple abdominal compression to dampen and suppress tumor motion.
- Open Access
- 8 September 2014
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 15 (5) , 147-161
A dosimetric comparison of three‐dimensional conformal radiotherapy, volumetric‐modulated arc therapy, and dynamic conformal arc therapy in the treatment of non‐small cell lung cancer using stereotactic body radiotherapy
This study evaluates three-dimensional conformal radiotherapy (3D CRT), volumetric- modulated arc therapy (VMAT), and dynamic conformal arc therapy (DCAT) planning techniques using dosimetric indices from Radiation Therapy Oncology Group (RTOG) protocols 0236, 0813, and 0915 for the treatment of early-stage non-small cell lung cancer (NSCLC) using stereotactic body radiotherapy (SBRT). Twenty-five clinical patients, five per lung lobe, previously treated for NSCLC using 3D CRT SBRT under respective RTOG protocols were replanned with VMAT and DCAT techniques. All plans were compared using respective RTOG dosimetric indices. High- and low-dose spillage improved for VMAT and DCAT plans, though only VMAT was able to improve dose to all organs at risk (OARs). DCAT was only able to provide a minimal improvement in dose to the heart and ipsilateral brachial plexus. Mean bilateral, contralateral, and (percentage of bilateral lung receiving at least 20 Gy dose) doses were reduced with VMAT in comparison with respective 3D CRT clinical plans. Though some of the DCAT plans had values for the above indices slightly higher than their respective 3D CRT plans, they still were able to meet the RTOG constraints. VMAT and DCAT were able to offer improved skin dose by 1.1% and 11%, respectively. Monitor units required for treatment delivery increased with VMAT by 41%, but decreased with DCAT by 26%. VMAT and DCAT provided improved dose distributions to the PTV, but only VMAT was consistently superior in sparing dose to OARs in all the five lobes. DCAT should still remain an alternative to 3D CRT in facilities that do not have VMAT or intensity-modulated radiotherapy (IMRT) capabilities. PACS numbers: 87.53.Ly, 87.55.dk, 87.55.D-- 8 September 2014
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 15 (5) , 147-161
Open AccessA dosimetric comparison of three‐dimensional conformal radiotherapy, volumetric‐modulated arc therapy, and dynamic conformal arc therapy in the treatment of non‐small cell lung cancer using stereotactic body radiotherapy
This study evaluates three-dimensional conformal radiotherapy (3D CRT), volumetric- modulated arc therapy (VMAT), and dynamic conformal arc therapy (DCAT) planning techniques using dosimetric indices from Radiation Therapy Oncology Group (RTOG) protocols 0236, 0813, and 0915 for the treatment of early-stage non-small cell lung cancer (NSCLC) using stereotactic body radiotherapy (SBRT). Twenty-five clinical patients, five per lung lobe, previously treated for NSCLC using 3D CRT SBRT under respective RTOG protocols were replanned with VMAT and DCAT techniques. All plans were compared using respective RTOG dosimetric indices. High- and low-dose spillage improved for VMAT and DCAT plans, though only VMAT was able to improve dose to all organs at risk (OARs). DCAT was only able to provide a minimal improvement in dose to the heart and ipsilateral brachial plexus. Mean bilateral, contralateral, and (percentage of bilateral lung receiving at least 20 Gy dose) doses were reduced with VMAT in comparison with respective 3D CRT clinical plans. Though some of the DCAT plans had values for the above indices slightly higher than their respective 3D CRT plans, they still were able to meet the RTOG constraints. VMAT and DCAT were able to offer improved skin dose by 1.1% and 11%, respectively. Monitor units required for treatment delivery increased with VMAT by 41%, but decreased with DCAT by 26%. VMAT and DCAT provided improved dose distributions to the PTV, but only VMAT was consistently superior in sparing dose to OARs in all the five lobes. DCAT should still remain an alternative to 3D CRT in facilities that do not have VMAT or intensity-modulated radiotherapy (IMRT) capabilities. PACS numbers: 87.53.Ly, 87.55.dk, 87.55.D- - 4 March 2014
- Published by Wiley in Medical Physics
- Vol. 41 (4) , 040601
A 3D‐conformal technique is better than IMRT or VMAT for lung SBRT
- 4 March 2014
- Published by Wiley in Medical Physics
- Vol. 41 (4) , 040601
A 3D‐conformal technique is better than IMRT or VMAT for lung SBRT
- 28 February 2011
- Published by Elsevier in Medical Dosimetry
- Vol. 35 (4) , 269-273
Variability of Marker-Based Rectal Dose Evaluation in HDR Cervical Brachytherapy
- 28 February 2011
- Published by Elsevier in Medical Dosimetry
- Vol. 35 (4) , 269-273
Variability of Marker-Based Rectal Dose Evaluation in HDR Cervical Brachytherapy