A dosimetric comparison of three‐dimensional conformal radiotherapy, volumetric‐modulated arc therapy, and dynamic conformal arc therapy in the treatment of non‐small cell lung cancer using stereotactic body radiotherapy
Open Access
- 8 September 2014
- journal article
- research article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 15 (5) , 147-161
Abstract
This study evaluates three-dimensional conformal radiotherapy (3D CRT), volumetric- modulated arc therapy (VMAT), and dynamic conformal arc therapy (DCAT) planning techniques using dosimetric indices from Radiation Therapy Oncology Group (RTOG) protocols 0236, 0813, and 0915 for the treatment of early-stage non-small cell lung cancer (NSCLC) using stereotactic body radiotherapy (SBRT). Twenty-five clinical patients, five per lung lobe, previously treated for NSCLC using 3D CRT SBRT under respective RTOG protocols were replanned with VMAT and DCAT techniques. All plans were compared using respective RTOG dosimetric indices. High- and low-dose spillage improved for VMAT and DCAT plans, though only VMAT was able to improve dose to all organs at risk (OARs). DCAT was only able to provide a minimal improvement in dose to the heart and ipsilateral brachial plexus. Mean bilateral, contralateral, and (percentage of bilateral lung receiving at least 20 Gy dose) doses were reduced with VMAT in comparison with respective 3D CRT clinical plans. Though some of the DCAT plans had values for the above indices slightly higher than their respective 3D CRT plans, they still were able to meet the RTOG constraints. VMAT and DCAT were able to offer improved skin dose by 1.1% and 11%, respectively. Monitor units required for treatment delivery increased with VMAT by 41%, but decreased with DCAT by 26%. VMAT and DCAT provided improved dose distributions to the PTV, but only VMAT was consistently superior in sparing dose to OARs in all the five lobes. DCAT should still remain an alternative to 3D CRT in facilities that do not have VMAT or intensity-modulated radiotherapy (IMRT) capabilities. PACS numbers: 87.53.Ly, 87.55.dk, 87.55.D-
Keywords
This publication has 27 references indexed in Scilit:
- Clinical impact of using the deterministic patient dose calculation algorithm Acuros XB for lung stereotactic body radiation therapyActa Oncologica, 2013
- Critical Appraisal of Acuros XB and Anisotropic Analytic Algorithm Dose Calculation in Advanced Non-Small-Cell Lung Cancer TreatmentsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Dosimetric Impact of Breathing Motion in Lung Stereotactic Body Radiotherapy Treatment Using Image-Modulated Radiotherapy and Volumetric Modulated Arc TherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Fast Arc Delivery for Stereotactic Body Radiotherapy of Vertebral and Lung TumorsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Volumetric modulated arc planning for lung stereotactic body radiotherapy using conventional and unflattened photon beams: a dosimetric comparison with 3D techniqueRadiation Oncology, 2011
- Feasibility and early clinical assessment of flattening filter free (FFF) based stereotactic body radiotherapy (SBRT) treatmentsRadiation Oncology, 2011
- Dosimetric evaluation of Acuros XB Advanced Dose Calculation algorithm in heterogeneous mediaRadiation Oncology, 2011
- Volumetric modulated arc therapy for delivery of hypofractionated stereotactic lung radiotherapy: A dosimetric and treatment efficiency analysisRadiotherapy and Oncology, 2010
- Outcome in a Prospective Phase II Trial of Medically Inoperable Stage I Non–Small-Cell Lung Cancer Patients Treated With Stereotactic Body RadiotherapyJournal of Clinical Oncology, 2009
- Excessive Toxicity When Treating Central Tumors in a Phase II Study of Stereotactic Body Radiation Therapy for Medically Inoperable Early-Stage Lung CancerJournal of Clinical Oncology, 2006