Philippe Bournot
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Philippe Bournot has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Hatem Mhiri
National Engineering School of Monastir
4 shared publications - Monia Chaabane
Laboratory of Thermal and Thermodynamic in Industrial Processes (LRTTPI) National Engineering School of Monastir Monastir Tunisia
3 shared publications - Anissa Ghomrassi
National Engineering School of Monastir
1 shared publication - Hatem Dhaouadi
Research Laboratory of Environmental Chemistry and Clean Processes (LR21ES04), Department of Chemistry, Faculty of Sciences, University of Monastir, Monastir, Tunisia
1 shared publication - Rim Farjallah
Unité de Thermique et Thermodynamique des Procédés Industriels, Ecole Nationale d'Ingénieurs de Monastir, Route de Ouardanine, Monastir 5000, Tunisia
1 shared publication
Latest Publications
- 20 September 2016
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 138 (6) , 061008
Thermal Performance of the U-Tube Solar Collector Using Computational Fluid Dynamics Simulation
In this paper, we propose a numerical study of a tubular solar collector with a U-tube. A three-dimensional numerical model is developed. It was first used in order to study the efficiency of the solar collector and to evaluate the validity of the developed computational fluid dynamics (CFD) model by comparison with experimental results from the literature. For the numerical simulations, the turbulence and the radiation were, respectively, modeled using the standard k–ε model and the discrete ordinates (DO) model. This numerical model was then used to carry out a parametrical study and to discuss the effect of selected operating parameters such as the fluid mass flow rate, the absorber selectivity, and the material properties. Numerical results show that with the increase of the working fluid flow rate from 0.001 kg/s to 0.003 kg/s, the efficiency of the solar collector is improved (from 30% to 35%). Numerical results also show that the filled-type evacuated tube with graphite presents a best result in comparison with those found using the copper fin tube (η increases from 54% to 64%). Finally, we noted that the use of a high selective absorber surface adds to better performance in comparison with the black absorber tube. This is mainly due to the radiation losses reduction.
- 20 September 2016
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 138 (6) , 061008
Thermal Performance of the U-Tube Solar Collector Using Computational Fluid Dynamics Simulation
In this paper, we propose a numerical study of a tubular solar collector with a U-tube. A three-dimensional numerical model is developed. It was first used in order to study the efficiency of the solar collector and to evaluate the validity of the developed computational fluid dynamics (CFD) model by comparison with experimental results from the literature. For the numerical simulations, the turbulence and the radiation were, respectively, modeled using the standard k–ε model and the discrete ordinates (DO) model. This numerical model was then used to carry out a parametrical study and to discuss the effect of selected operating parameters such as the fluid mass flow rate, the absorber selectivity, and the material properties. Numerical results show that with the increase of the working fluid flow rate from 0.001 kg/s to 0.003 kg/s, the efficiency of the solar collector is improved (from 30% to 35%). Numerical results also show that the filled-type evacuated tube with graphite presents a best result in comparison with those found using the copper fin tube (η increases from 54% to 64%). Finally, we noted that the use of a high selective absorber surface adds to better performance in comparison with the black absorber tube. This is mainly due to the radiation losses reduction.
- 1 October 2015
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 137 (5) , 051003
Numerical Study and Optimization of Parabolic Trough Solar Collector Receiver Tube
In this study, the parabolic trough collector's (PTC) performance is analyzed. In order to achieve this goal, the adopted procedure comprises two main steps. In the first step, the concentrated solar heat flux densities in the solar concentrator focal zone are calculated by soltrace software. In the second step, computational fluid dynamics (CFD) simulations are carried out to analyze and to optimize the thermal performance of the tube receiver. The calculated heat flux densities by soltrace software are used as wall heat flux boundary conditions for the receiver tube. The effect of the receiver tube diameter variation on the PTC thermal performance is studied. A new type of receiver tube is tested. This latter is covered with a metallic thickness. The performance of tube receiver covered with a metallic layer for different diameters is compared to those of the same diameters without the addition of metallic thickness. It has been found that increasing tube metallic thickness enhances the performance of PTC system comparing to the tubes of the same diameter and crossed by the same flow rates.
- 1 October 2015
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 137 (5) , 051003
Numerical Study and Optimization of Parabolic Trough Solar Collector Receiver Tube
In this study, the parabolic trough collector's (PTC) performance is analyzed. In order to achieve this goal, the adopted procedure comprises two main steps. In the first step, the concentrated solar heat flux densities in the solar concentrator focal zone are calculated by soltrace software. In the second step, computational fluid dynamics (CFD) simulations are carried out to analyze and to optimize the thermal performance of the tube receiver. The calculated heat flux densities by soltrace software are used as wall heat flux boundary conditions for the receiver tube. The effect of the receiver tube diameter variation on the PTC thermal performance is studied. A new type of receiver tube is tested. This latter is covered with a metallic thickness. The performance of tube receiver covered with a metallic layer for different diameters is compared to those of the same diameters without the addition of metallic thickness. It has been found that increasing tube metallic thickness enhances the performance of PTC system comparing to the tubes of the same diameter and crossed by the same flow rates.
- 25 August 2014
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 137 (1) , 011009
Effect of the Water Storage Tank Coverage With an Outer Glass Tube on the Thermal Performance of an Integrated Collector Storage Solar Water Heater
The thermal performance of an integrated collector storage solar water heater (ICSSWH) is numerically examined using the numerical software Fluent 6.3. As this solar system presents the disadvantage of its high night thermal losses, a new strategy helping to reduce these losses is proposed. A particular system in which the storage tank is covered with an outer glass tube is studied and a parametric study is conducted in order to evaluate the optimal air spacing gap between the water tank and the covering glass tube which minimizes this system's heat losses. A 3D computational fluid dynamics (CFD) model interpreting this modified system is so developed and its thermal performance is compared to that of the noncovered tank based ICSSWH. The analysis of these solar systems daily performance shows that the modified ICSSWH is able to generate more thermal output and presents the advantage of its lower thermal losses. Regarding the night operating, this covered tank based ICSSWH is shown more effective in retaining higher temperatures for longer period, resulting so in lower night thermal losses. Results also suggest that the best performance corresponds to the lowest air gap spacing (L = 0.005 m).
- 25 August 2014
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 137 (1) , 011009
Effect of the Water Storage Tank Coverage With an Outer Glass Tube on the Thermal Performance of an Integrated Collector Storage Solar Water Heater
The thermal performance of an integrated collector storage solar water heater (ICSSWH) is numerically examined using the numerical software Fluent 6.3. As this solar system presents the disadvantage of its high night thermal losses, a new strategy helping to reduce these losses is proposed. A particular system in which the storage tank is covered with an outer glass tube is studied and a parametric study is conducted in order to evaluate the optimal air spacing gap between the water tank and the covering glass tube which minimizes this system's heat losses. A 3D computational fluid dynamics (CFD) model interpreting this modified system is so developed and its thermal performance is compared to that of the noncovered tank based ICSSWH. The analysis of these solar systems daily performance shows that the modified ICSSWH is able to generate more thermal output and presents the advantage of its lower thermal losses. Regarding the night operating, this covered tank based ICSSWH is shown more effective in retaining higher temperatures for longer period, resulting so in lower night thermal losses. Results also suggest that the best performance corresponds to the lowest air gap spacing (L = 0.005 m).
- 4 April 2014
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 50 (10) , 1335-1341
Effect of the storage tank thermal insulation on the thermal performance of an integrated collector storage solar water heater (ICSSWH)
- 4 April 2014
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 50 (10) , 1335-1341
Effect of the storage tank thermal insulation on the thermal performance of an integrated collector storage solar water heater (ICSSWH)