Monia Chaabane
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Monia Chaabane has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Hatem Mhiri
LRTTPI, ENIM, University of Monastir, Monastir, Tunisia
9 shared publications- Hatem Mhiri
National Engineering School of Monastir
4 shared publications Philippe Bournot
Aix Marseille Univ, CNRS, IUSTI
4 shared publicationsSalma Benzarti
Department of Energy Engineering, National Engineering School of Monastir, Monastir University, Monastir, Tunisia
4 shared publications- Philippe Bournot
IUSTI, UMR CNRS 6595, 5 Rue Enrico Fermi, Technopôle de Château-Gombert, Marseille 13013, France
3 shared publications Hervé Bournot
CNRS, IUSTI, Aix Marseille Univ, Marseille, France
2 shared publications
Latest Publications
- 23 May 2026
- Published by Springer Nature in Water Resources Management
- Vol. 40 (8) , 355
Design and Implementation of a Novel Smart Agriculture’s Irrigation System Integrating IoT Technologies
- 23 May 2026
- Published by Springer Nature in Water Resources Management
- Vol. 40 (8) , 355
Design and Implementation of a Novel Smart Agriculture’s Irrigation System Integrating IoT Technologies
- 10 March 2026
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 40 (3) , 2283-2291
Performance enhancement of a building integrated photovoltaic system using wavy fins and slots
- 10 March 2026
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 40 (3) , 2283-2291
Performance enhancement of a building integrated photovoltaic system using wavy fins and slots
- Open Access
- 15 December 2025
- Published by Wiley in Energy Science & Engineering
- Vol. 14 (3) , 1180-1194
Optimization and Assessment of Parabolic Trough Solar Power Plants in Arid Climates: A Case Study in Tunisia
This study aims to model a solar power plant (SPP) utilizing parabolic trough collectors (PTC) to fulfill the electricity needs in an arid zone of the southern of Tunisia. The research integrates both experimental and numerical approaches. A prototype of a PTC was first constructed and experimentally tested under arid climates. Subsequently, a numerical study was carried out using the Transient Systems Simulation (TRNSYS) software to assess its annual performance. The comparison reveals a good agreement between the TRNSYS‐modeled PTC system and the experimental data. The study further examines the power plant's performance under several operating scenarios. These evaluations aim to verify reliable operation and the ability to satisfy the chosen site's energy requirements. The solar field was optimized to cover 65,000 m 2 , producing an annual energy output of 4.52 GWh, which is sufficient to supply the electrical needs of a delegation in Tunisia called Hazoua. Different combinations of energy sources are studied. Results show that the hybrid solution, comprising 60% solar energy and 40% gas backup, demonstrates technical advantages with a system efficiency of 22%. The optimization scenario is also reinforced by an economic study. In fact, the Levelized Cost of Electricity (LCOE) of the power plant is of 0.1815 USD/kWh and the Payback Period (PP) is 4 years and 7 months, which indicates its strong competitiveness compared to transmission costs. Likewise, the environmental aspect is taken into account and the suggested hybrid strategy has the potential to reduce annually by about 925,000 kg CO 2 emissions. This work can guide decision‐making for utilities and policymakers for rural electrification in arid regions aiming to implement efficient and reliable renewable energy solutions in such zones.
- 15 December 2025
- Published by Wiley in Energy Science & Engineering
- Vol. 14 (3) , 1180-1194
Open AccessOptimization and Assessment of Parabolic Trough Solar Power Plants in Arid Climates: A Case Study in Tunisia
This study aims to model a solar power plant (SPP) utilizing parabolic trough collectors (PTC) to fulfill the electricity needs in an arid zone of the southern of Tunisia. The research integrates both experimental and numerical approaches. A prototype of a PTC was first constructed and experimentally tested under arid climates. Subsequently, a numerical study was carried out using the Transient Systems Simulation (TRNSYS) software to assess its annual performance. The comparison reveals a good agreement between the TRNSYS‐modeled PTC system and the experimental data. The study further examines the power plant's performance under several operating scenarios. These evaluations aim to verify reliable operation and the ability to satisfy the chosen site's energy requirements. The solar field was optimized to cover 65,000 m 2 , producing an annual energy output of 4.52 GWh, which is sufficient to supply the electrical needs of a delegation in Tunisia called Hazoua. Different combinations of energy sources are studied. Results show that the hybrid solution, comprising 60% solar energy and 40% gas backup, demonstrates technical advantages with a system efficiency of 22%. The optimization scenario is also reinforced by an economic study. In fact, the Levelized Cost of Electricity (LCOE) of the power plant is of 0.1815 USD/kWh and the Payback Period (PP) is 4 years and 7 months, which indicates its strong competitiveness compared to transmission costs. Likewise, the environmental aspect is taken into account and the suggested hybrid strategy has the potential to reduce annually by about 925,000 kg CO 2 emissions. This work can guide decision‐making for utilities and policymakers for rural electrification in arid regions aiming to implement efficient and reliable renewable energy solutions in such zones.
- 30 November 2025
- Published by SAGE Publications in Journal of Building Physics
- Vol. 49 (5) , 686-710
Performance improvement of a building integrated photovoltaic system
In this study, the effect of fins integration on the operating of a Building integrated photovoltaic (BIPV) system is investigated using CFD simulations. Various designs of the cooling system, directly attached to the rear side of the PV cells, are proposed and analyzed. The considered extended heat transfer surfaces are straight and wavy fins of different shift angles and the corresponding effect on this system operating is evaluated. Results revealed that the proposed cooling techniques have proven effective in reducing the solar cell average temperature, thereby increasing the electrical conversion efficiency for the corresponding system. Concerning the best improvement, it corresponds to wavy fins with a shift angle of 180° where a temperature reduction of about 15°C was noted ( T * = 1.8), which allowed an increase of the electrical efficiency achieving 8.2%. In this wavy fins equipped system, curved inserts allowing the flow to be directed between each two successive fins, are introduced. The proposed system provides better heat exchange, as shown in the Nusselt number analysis; the corresponding average Nusselt number is increased up to 81% compared to the BIPV without fins and up to 16% compared to the system with only wavy fins. The resulting improvement of heat dissipation affected the PV temperature’s levels and consequently allowed an increase in the BIPV system electrical efficiency of about 11% compared to the system without fins. Similarly, a more uniform temperature distribution is noted, which directly affect the BIPV system life time.
- 30 November 2025
- Published by SAGE Publications in Journal of Building Physics
- Vol. 49 (5) , 686-710
Performance improvement of a building integrated photovoltaic system
In this study, the effect of fins integration on the operating of a Building integrated photovoltaic (BIPV) system is investigated using CFD simulations. Various designs of the cooling system, directly attached to the rear side of the PV cells, are proposed and analyzed. The considered extended heat transfer surfaces are straight and wavy fins of different shift angles and the corresponding effect on this system operating is evaluated. Results revealed that the proposed cooling techniques have proven effective in reducing the solar cell average temperature, thereby increasing the electrical conversion efficiency for the corresponding system. Concerning the best improvement, it corresponds to wavy fins with a shift angle of 180° where a temperature reduction of about 15°C was noted ( T * = 1.8), which allowed an increase of the electrical efficiency achieving 8.2%. In this wavy fins equipped system, curved inserts allowing the flow to be directed between each two successive fins, are introduced. The proposed system provides better heat exchange, as shown in the Nusselt number analysis; the corresponding average Nusselt number is increased up to 81% compared to the BIPV without fins and up to 16% compared to the system with only wavy fins. The resulting improvement of heat dissipation affected the PV temperature’s levels and consequently allowed an increase in the BIPV system electrical efficiency of about 11% compared to the system without fins. Similarly, a more uniform temperature distribution is noted, which directly affect the BIPV system life time.
- 20 August 2022
- Published by Springer Nature
- p. 276-284
Performance Improvement of Water-Cooled BIPV/T System
- 20 August 2022
- Published by Springer Nature
- p. 276-284
Performance Improvement of Water-Cooled BIPV/T System
- 25 April 2022
- Published by Elsevier in Journal of Building Engineering
- Vol. 53, 104553
Performance improvement of a naturally ventilated building integrated photovoltaic system using twisted baffle inserts
- 25 April 2022
- Published by Elsevier in Journal of Building Engineering
- Vol. 53, 104553
Performance improvement of a naturally ventilated building integrated photovoltaic system using twisted baffle inserts
- 1 July 2020
- Published by AIP Publishing in Journal of Renewable and Sustainable Energy
- Vol. 12 (4) , 043702
Thermal performance evaluation and enhancement of a parabolic trough collector
In this article, the effect of concentration technology on the thermal performance of a solar water heating system is investigated. A three-dimensional numerical simulation of a parabolic trough collector (PTC) is carried out using the commercial software ANSYS. The performance of a line-focus concentration system is compared to that of an integrated collector storage solar water heater. The PTC provides more useful heat but has higher nighttime thermal losses. It is proposed to reduce nighttime energy loss by insulating the PTC storage tank. The effects of the insulation coverage strategy and medium are discussed. Numerical results show that the thermal insulation material significantly influences heat transfer. Indeed, addition of glass wool reduces heat collection during the day and improves heat preservation at night, while adding an air-filled glass tube increases heat transfer during the day and reduces nighttime thermal losses. The effect of tank insulation coverage is also investigated. This solar system performs best when the upper half of the tank is insulated. The maximum water temperature is 360.5 K, the overall thermal loss coefficient is 9.38 W/m2 K, and the nighttime thermal loss coefficient is 6.2 W/m K. The optimum PTC configuration is one in which the upper half of the tank is insulated by a 0.01 m-thick layer of air that is held in place by glass. This optimized system provides 29% more useful heat, a lower overall heat loss coefficient of 14.9%, and a lower nighttime heat loss coefficient of 62% than the non-insulated-tank-based PTC.
- 1 July 2020
- Published by AIP Publishing in Journal of Renewable and Sustainable Energy
- Vol. 12 (4) , 043702
Thermal performance evaluation and enhancement of a parabolic trough collector
In this article, the effect of concentration technology on the thermal performance of a solar water heating system is investigated. A three-dimensional numerical simulation of a parabolic trough collector (PTC) is carried out using the commercial software ANSYS. The performance of a line-focus concentration system is compared to that of an integrated collector storage solar water heater. The PTC provides more useful heat but has higher nighttime thermal losses. It is proposed to reduce nighttime energy loss by insulating the PTC storage tank. The effects of the insulation coverage strategy and medium are discussed. Numerical results show that the thermal insulation material significantly influences heat transfer. Indeed, addition of glass wool reduces heat collection during the day and improves heat preservation at night, while adding an air-filled glass tube increases heat transfer during the day and reduces nighttime thermal losses. The effect of tank insulation coverage is also investigated. This solar system performs best when the upper half of the tank is insulated. The maximum water temperature is 360.5 K, the overall thermal loss coefficient is 9.38 W/m2 K, and the nighttime thermal loss coefficient is 6.2 W/m K. The optimum PTC configuration is one in which the upper half of the tank is insulated by a 0.01 m-thick layer of air that is held in place by glass. This optimized system provides 29% more useful heat, a lower overall heat loss coefficient of 14.9%, and a lower nighttime heat loss coefficient of 62% than the non-insulated-tank-based PTC.
- 26 September 2019
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 16 (14) , 1295-1303
Performance evaluation of solar photovoltaic systems
Flat plane and concentrating photovoltaic systems are the two major technologies for sunlight direct conversion into electricity. This work compares the energy generation potential of concentrating and non-concentrating PV systems under a summer clear sky day of the Tunisian Saharan city Tozeur. A fixed PV panel directly exposed to the solar irradiance is firstly studied. An asymmetric compound parabolic concentrator was then designed and used to focus the solar irradiance on this PV panel, which collects so the reflected sunlight. The electrical performance of these systems is experimentally characterized, and results indicate that the concentrating PV system performs better regarding the system output and electrical efficiency. Similarly, a financial analysis is performed and justify our solar installation choice. Two 3D CFD models describing the performance of these solar systems are then developed and experimental data are used for these models validation. Based on the good agreement between the numerical and experimental results, the performance of these two systems is evaluated of a cloudy day, the effect of the weather conditions is so discussed and the optimum design is evaluated.
- 26 September 2019
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 16 (14) , 1295-1303
Performance evaluation of solar photovoltaic systems
Flat plane and concentrating photovoltaic systems are the two major technologies for sunlight direct conversion into electricity. This work compares the energy generation potential of concentrating and non-concentrating PV systems under a summer clear sky day of the Tunisian Saharan city Tozeur. A fixed PV panel directly exposed to the solar irradiance is firstly studied. An asymmetric compound parabolic concentrator was then designed and used to focus the solar irradiance on this PV panel, which collects so the reflected sunlight. The electrical performance of these systems is experimentally characterized, and results indicate that the concentrating PV system performs better regarding the system output and electrical efficiency. Similarly, a financial analysis is performed and justify our solar installation choice. Two 3D CFD models describing the performance of these solar systems are then developed and experimental data are used for these models validation. Based on the good agreement between the numerical and experimental results, the performance of these two systems is evaluated of a cloudy day, the effect of the weather conditions is so discussed and the optimum design is evaluated.
- 20 September 2016
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 138 (6) , 061008
Thermal Performance of the U-Tube Solar Collector Using Computational Fluid Dynamics Simulation
In this paper, we propose a numerical study of a tubular solar collector with a U-tube. A three-dimensional numerical model is developed. It was first used in order to study the efficiency of the solar collector and to evaluate the validity of the developed computational fluid dynamics (CFD) model by comparison with experimental results from the literature. For the numerical simulations, the turbulence and the radiation were, respectively, modeled using the standard k–ε model and the discrete ordinates (DO) model. This numerical model was then used to carry out a parametrical study and to discuss the effect of selected operating parameters such as the fluid mass flow rate, the absorber selectivity, and the material properties. Numerical results show that with the increase of the working fluid flow rate from 0.001 kg/s to 0.003 kg/s, the efficiency of the solar collector is improved (from 30% to 35%). Numerical results also show that the filled-type evacuated tube with graphite presents a best result in comparison with those found using the copper fin tube (η increases from 54% to 64%). Finally, we noted that the use of a high selective absorber surface adds to better performance in comparison with the black absorber tube. This is mainly due to the radiation losses reduction.
- 20 September 2016
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 138 (6) , 061008
Thermal Performance of the U-Tube Solar Collector Using Computational Fluid Dynamics Simulation
In this paper, we propose a numerical study of a tubular solar collector with a U-tube. A three-dimensional numerical model is developed. It was first used in order to study the efficiency of the solar collector and to evaluate the validity of the developed computational fluid dynamics (CFD) model by comparison with experimental results from the literature. For the numerical simulations, the turbulence and the radiation were, respectively, modeled using the standard k–ε model and the discrete ordinates (DO) model. This numerical model was then used to carry out a parametrical study and to discuss the effect of selected operating parameters such as the fluid mass flow rate, the absorber selectivity, and the material properties. Numerical results show that with the increase of the working fluid flow rate from 0.001 kg/s to 0.003 kg/s, the efficiency of the solar collector is improved (from 30% to 35%). Numerical results also show that the filled-type evacuated tube with graphite presents a best result in comparison with those found using the copper fin tube (η increases from 54% to 64%). Finally, we noted that the use of a high selective absorber surface adds to better performance in comparison with the black absorber tube. This is mainly due to the radiation losses reduction.
- 25 August 2014
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 137 (1) , 011009
Effect of the Water Storage Tank Coverage With an Outer Glass Tube on the Thermal Performance of an Integrated Collector Storage Solar Water Heater
The thermal performance of an integrated collector storage solar water heater (ICSSWH) is numerically examined using the numerical software Fluent 6.3. As this solar system presents the disadvantage of its high night thermal losses, a new strategy helping to reduce these losses is proposed. A particular system in which the storage tank is covered with an outer glass tube is studied and a parametric study is conducted in order to evaluate the optimal air spacing gap between the water tank and the covering glass tube which minimizes this system's heat losses. A 3D computational fluid dynamics (CFD) model interpreting this modified system is so developed and its thermal performance is compared to that of the noncovered tank based ICSSWH. The analysis of these solar systems daily performance shows that the modified ICSSWH is able to generate more thermal output and presents the advantage of its lower thermal losses. Regarding the night operating, this covered tank based ICSSWH is shown more effective in retaining higher temperatures for longer period, resulting so in lower night thermal losses. Results also suggest that the best performance corresponds to the lowest air gap spacing (L = 0.005 m).
- 25 August 2014
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 137 (1) , 011009
Effect of the Water Storage Tank Coverage With an Outer Glass Tube on the Thermal Performance of an Integrated Collector Storage Solar Water Heater
The thermal performance of an integrated collector storage solar water heater (ICSSWH) is numerically examined using the numerical software Fluent 6.3. As this solar system presents the disadvantage of its high night thermal losses, a new strategy helping to reduce these losses is proposed. A particular system in which the storage tank is covered with an outer glass tube is studied and a parametric study is conducted in order to evaluate the optimal air spacing gap between the water tank and the covering glass tube which minimizes this system's heat losses. A 3D computational fluid dynamics (CFD) model interpreting this modified system is so developed and its thermal performance is compared to that of the noncovered tank based ICSSWH. The analysis of these solar systems daily performance shows that the modified ICSSWH is able to generate more thermal output and presents the advantage of its lower thermal losses. Regarding the night operating, this covered tank based ICSSWH is shown more effective in retaining higher temperatures for longer period, resulting so in lower night thermal losses. Results also suggest that the best performance corresponds to the lowest air gap spacing (L = 0.005 m).