Yunxiao Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yunxiao Liu has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Sajay Bhuvanendran Nair Gourikutty
Agency for Science, Technology and Research, 2 Fusionopolis Way, #08-02, Innovis Tower, Singapore 138635, Singapore
3 shared publications Chia-Pin Chang
Miniaturized Medical Device Program and ‡Bio-Electronic Program, Institute of Microelectronic, A* STAR (Agency for Science, Technology and Research), 11 Science Park Road, Science Park II, Singapore 117685
1 shared publication- Jiqiang Wang
Ningbo Institute of Materials Technology & Engineering, Chinese Academy of Sciences, Ningbo 315201, China
1 shared publication Patthara Kongsuphol
Institute of Microelectronics, 2, Fusionopolis Way, #08-02, Innovis Tower, Singapore, 138635, Singapore
1 shared publication- Patthara Kongsuphol
Institute of Microelectronics, Agency for Science, Technology and Research, Singapore
1 shared publication Qasem Alramadan
Institute of Microelectronics, Agency for Science Technology and Research (A*STAR)
1 shared publication
Latest Publications
- 8 September 2019
- Published by Springer Nature
- p. 91-99
Atmospheric Turbulence Rejection Control for a Geared Turbofan Engine
- 8 September 2019
- Published by Springer Nature
- p. 91-99
Atmospheric Turbulence Rejection Control for a Geared Turbofan Engine
- Open Access
- 21 July 2017
- Published by MDPI AG
LAB ON A CHIP PERFUSION DEVICE FOR CONSTRUCTING MICRO-PHYSIOLOGICAL IN VITRO MODEL OF HUMAN ORGANS
Micro-physiological in vitro models providing in vivo like environment has abundant prospects in the field of drug discovery and monitoring the physiological events. These models are currently achieved in setups like dual compartment cell culture Transwell system in which cells are grown in an insert with a porous membrane. Such in vitro tools are static in nature and therefore cannot simulate fully the in vivo conditions inside body [1]. Using these techniques needs a large amount of cells, reagents and culture media, which makes this a rather expensive approach. These models are also limited with number of simulated parameters, and are dedicated to a particular application [2-3]. In our previous work [4], we have tested an intestinal model using porous silicon membrane with pores of well controlled dimensions. In this study, we are developing a microfluidic-based lab-on-chip platform for studying the interaction of various types of cells by co-culturing them and to use this platform for in vitro modeling of human organs. Here, the processes used in typical cell culture experiments are incorporated in an independent microfluidic platform. We report the characterization and optimization of device designs accomplished by means of in-depth FEA simulations (Fig. 1). The chip is made from silicon substrate, which allows us to create features with well controlled dimensions and the critical structures are realized by Deep reactive-ion etching (DRIE) process. The silicon chip itself is 15 mm wide and 40 mm long, capped with glass by means of anodic bonding which provides a leak proof fluidic system and the fluidic channels are accessed through a polymethyl methacrylate (PMMA) jig (Fig. 3). We have developed different chip designs suitable for diverse applications. The major component of the microfluidic device is a perfusion-based microflouidic structure (Fig. 2) which allows the communication between different cell types as well as facilitates the fluid flow. The cell co-culture (Fig. 4b) is achieved by growing them in discrete chambers separated by porous barriers which forms the perfusion structure. The perfusion channels provide opening ranging from 4 to 30 µm2 optimized based on the function of each chamber. This platform provides dynamic environment by precisely controlling the flow rate, spatiotemporal gradients, mechanical stress by fluid flow etc. which enable us to mimic the tissue structure and functions with better physiological relevance. This Organ-on-a-chip design can offer several cell culture chambers with either identical or different cellular structures to study the role of each cell type as well as to compare the cell response to various chemical exposures in parallel experiments.
- 21 July 2017
- Published by MDPI AG
Open AccessLAB ON A CHIP PERFUSION DEVICE FOR CONSTRUCTING MICRO-PHYSIOLOGICAL IN VITRO MODEL OF HUMAN ORGANS
Micro-physiological in vitro models providing in vivo like environment has abundant prospects in the field of drug discovery and monitoring the physiological events. These models are currently achieved in setups like dual compartment cell culture Transwell system in which cells are grown in an insert with a porous membrane. Such in vitro tools are static in nature and therefore cannot simulate fully the in vivo conditions inside body [1]. Using these techniques needs a large amount of cells, reagents and culture media, which makes this a rather expensive approach. These models are also limited with number of simulated parameters, and are dedicated to a particular application [2-3]. In our previous work [4], we have tested an intestinal model using porous silicon membrane with pores of well controlled dimensions. In this study, we are developing a microfluidic-based lab-on-chip platform for studying the interaction of various types of cells by co-culturing them and to use this platform for in vitro modeling of human organs. Here, the processes used in typical cell culture experiments are incorporated in an independent microfluidic platform. We report the characterization and optimization of device designs accomplished by means of in-depth FEA simulations (Fig. 1). The chip is made from silicon substrate, which allows us to create features with well controlled dimensions and the critical structures are realized by Deep reactive-ion etching (DRIE) process. The silicon chip itself is 15 mm wide and 40 mm long, capped with glass by means of anodic bonding which provides a leak proof fluidic system and the fluidic channels are accessed through a polymethyl methacrylate (PMMA) jig (Fig. 3). We have developed different chip designs suitable for diverse applications. The major component of the microfluidic device is a perfusion-based microflouidic structure (Fig. 2) which allows the communication between different cell types as well as facilitates the fluid flow. The cell co-culture (Fig. 4b) is achieved by growing them in discrete chambers separated by porous barriers which forms the perfusion structure. The perfusion channels provide opening ranging from 4 to 30 µm2 optimized based on the function of each chamber. This platform provides dynamic environment by precisely controlling the flow rate, spatiotemporal gradients, mechanical stress by fluid flow etc. which enable us to mimic the tissue structure and functions with better physiological relevance. This Organ-on-a-chip design can offer several cell culture chambers with either identical or different cellular structures to study the role of each cell type as well as to compare the cell response to various chemical exposures in parallel experiments.
- Open Access
- 21 July 2017
- Published by MDPI AG
In vitro micro-physiological models for predictive toxicology and disease modelling
Organotypic culture of human tissue has a great potential to bridge the existing gap between in vivo and in vitro studies and to enable in-depth study of disease pathogenesis and therapy with low cost. Recent advances in microfluidic-based co-cell culture have enabled the realization of physiologically relevant in vitro models of specific human tissues. These systems have been used to study the contribution of micro-environmental factors to cellular morphogenesis in health and disease states, therefore, can be used to answer fundamental biological questions and develop a reliable alternative to animal models, and enable screening of potential new drug compounds. In this paper, we will discuss three immune competent micro-physiological models, namely the human gastrointestinal tract1, the human epidermis2 and the adipose tissue3, the interaction of immune cells with these tissues and their role in inflammation. We will emphasis on the interaction between the adipocytes and immune cells to highlight the role of immune cell infiltration in the adipose tissue in the pathogenesis of diabetes type 2. A three-dimensional perfusion-based microfluidic system has been realized and utilized to host the three biological models. It enables co-culturing of two different types of cells that are physically separated but fluidically and chemically connected which enables the exchange of paracrine signals between the two cell types. The co-culture was maintained viable for more than three weeks during which cells were differentiated such that their phenotypes, morphologically and functionally, resemble the corresponding cells in the human tissue. Inflammation was induced in the biological system, and the response of the co-culture was detected. The biological models have been characterized in both health and disease states. Various commercial drugs are being tested to evaluate the in vitro system response. References Qasem Ramadan and Lin Jing. Characterization of tight junction disruption and immune response modulation in a miniaturized Caco-2/U937 coculture-based in vitro model of the human intestinal barrier, Biomedical Microdevices, 2016,18(1):11. Qasem Ramadan and Fiona Chia Wan Ting. In vitro micro-physiological immune-competent model of human skin. Lab Chip, 2016,16, 1899-1908. Yunxiao Liu, Patthara Kongsuphol, Sajay Bhuvanendran Nair Gourikutty, Qasem Ramadan. Human adipocyte differentiation and characterization in a perfusion-based cell culture device. Biomedical microdevices, Accepted. Acknowledgment This research was supported by the Agency for Science, Technology and Research (A*STAR) (Grant number: 1431AFG123).
- 21 July 2017
- Published by MDPI AG
Open AccessIn vitro micro-physiological models for predictive toxicology and disease modelling
Organotypic culture of human tissue has a great potential to bridge the existing gap between in vivo and in vitro studies and to enable in-depth study of disease pathogenesis and therapy with low cost. Recent advances in microfluidic-based co-cell culture have enabled the realization of physiologically relevant in vitro models of specific human tissues. These systems have been used to study the contribution of micro-environmental factors to cellular morphogenesis in health and disease states, therefore, can be used to answer fundamental biological questions and develop a reliable alternative to animal models, and enable screening of potential new drug compounds. In this paper, we will discuss three immune competent micro-physiological models, namely the human gastrointestinal tract1, the human epidermis2 and the adipose tissue3, the interaction of immune cells with these tissues and their role in inflammation. We will emphasis on the interaction between the adipocytes and immune cells to highlight the role of immune cell infiltration in the adipose tissue in the pathogenesis of diabetes type 2. A three-dimensional perfusion-based microfluidic system has been realized and utilized to host the three biological models. It enables co-culturing of two different types of cells that are physically separated but fluidically and chemically connected which enables the exchange of paracrine signals between the two cell types. The co-culture was maintained viable for more than three weeks during which cells were differentiated such that their phenotypes, morphologically and functionally, resemble the corresponding cells in the human tissue. Inflammation was induced in the biological system, and the response of the co-culture was detected. The biological models have been characterized in both health and disease states. Various commercial drugs are being tested to evaluate the in vitro system response. References Qasem Ramadan and Lin Jing. Characterization of tight junction disruption and immune response modulation in a miniaturized Caco-2/U937 coculture-based in vitro model of the human intestinal barrier, Biomedical Microdevices, 2016,18(1):11. Qasem Ramadan and Fiona Chia Wan Ting. In vitro micro-physiological immune-competent model of human skin. Lab Chip, 2016,16, 1899-1908. Yunxiao Liu, Patthara Kongsuphol, Sajay Bhuvanendran Nair Gourikutty, Qasem Ramadan. Human adipocyte differentiation and characterization in a perfusion-based cell culture device. Biomedical microdevices, Accepted. Acknowledgment This research was supported by the Agency for Science, Technology and Research (A*STAR) (Grant number: 1431AFG123).
- 29 March 2017
- Published by Springer Nature in Biomedical Microdevices
- Vol. 19 (3) , 1-10
Human adipocyte differentiation and characterization in a perfusion-based cell culture device
Adipocytes have gained significant attention recently, because they are not only functioning as energy storage but also as endocrine cells. Adipocytes secret various signaling molecules, including adiponectin, MCP-1, and IL-6, termed collectively as “adipokines”. Adipokines regulate glucose metabolism, thereby play an important role in obesity, diabetes type 2, and other metabolic disorders. Conventionally, to study the secretory function, adipocytes are cultured in vitro in static conditions. However, static culturing condition falls short of mimicking the interstitial fluid flows in living systems. Here, we developed a perfusion device which allows dynamic culture of adipocytes under constant and mild flow using a double-layered fluidic structure. Adipocytes were cultured in the bottom layer while the culture media were constantly flown in the upper layer and perfused through a porous membrane that separate the two chambers. The porous membrane between the two chambers physically separates the cells from the flow stream while maintain a fluidic connection by diffusion. This setting not only provides continuous nutrient supply to adipocytes but also maintains a steady and mild shear stress on the cell membrane. It was found the perfusion-based culture conditions promoted faster growth of primary preadipocytes and stimulated greater adipogenesis compared to static culture condition. Adipocytes cultured under perfusion systems produced more MCP-1 and IL-6, but less adiponectin. When stimulated with TNF-α, adipocytes expressed higher level of MCP-1 and IL-6, but lower level of adiponectin. No significant glucose uptake regulation was observed after treating the adipocytes with insulin in both static and perfusion-based culture. Our results demonstrate that perfusion-base culture has played a role in the adipocyte function particularly the secretion of adipokines. More future studies are required to unveil the mechanisms behind perfusion’s impact on adipocytes.
- 29 March 2017
- Published by Springer Nature in Biomedical Microdevices
- Vol. 19 (3) , 1-10
Human adipocyte differentiation and characterization in a perfusion-based cell culture device
Adipocytes have gained significant attention recently, because they are not only functioning as energy storage but also as endocrine cells. Adipocytes secret various signaling molecules, including adiponectin, MCP-1, and IL-6, termed collectively as “adipokines”. Adipokines regulate glucose metabolism, thereby play an important role in obesity, diabetes type 2, and other metabolic disorders. Conventionally, to study the secretory function, adipocytes are cultured in vitro in static conditions. However, static culturing condition falls short of mimicking the interstitial fluid flows in living systems. Here, we developed a perfusion device which allows dynamic culture of adipocytes under constant and mild flow using a double-layered fluidic structure. Adipocytes were cultured in the bottom layer while the culture media were constantly flown in the upper layer and perfused through a porous membrane that separate the two chambers. The porous membrane between the two chambers physically separates the cells from the flow stream while maintain a fluidic connection by diffusion. This setting not only provides continuous nutrient supply to adipocytes but also maintains a steady and mild shear stress on the cell membrane. It was found the perfusion-based culture conditions promoted faster growth of primary preadipocytes and stimulated greater adipogenesis compared to static culture condition. Adipocytes cultured under perfusion systems produced more MCP-1 and IL-6, but less adiponectin. When stimulated with TNF-α, adipocytes expressed higher level of MCP-1 and IL-6, but lower level of adiponectin. No significant glucose uptake regulation was observed after treating the adipocytes with insulin in both static and perfusion-based culture. Our results demonstrate that perfusion-base culture has played a role in the adipocyte function particularly the secretion of adipokines. More future studies are required to unveil the mechanisms behind perfusion’s impact on adipocytes.
- 13 March 2014
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 30 (11) , 3118-3126
Dopamine-Assisted Deposition of Dextran for Nonfouling Applications
Nonfouling surfaces are essential for many biomedical applications, such as diagnostic biosensors and blood- or tissue-contacting implants. In this study, we demonstrate a simple one-step method to introduce dextran onto various substrates based on dopamine polymerization. It has been shown for the first time that dextran molecules could be incorporated into a dopamine polymerization product via mixing dextran with dopamine in a slightly alkaline solution. The codeposited film was characterized by X-ray photoelectron spectroscopy (XPS), the water contact angle, ellipsometry, and atomic force microscopy (AFM). Results reveal that it is possible to control the thickness and surface roughness via the deposition time and deposition repeat cycles. Furthermore, quartz crystal microbalance (QCM) measurements show that the dextran-modified surface inhibits protein adhesion. In addition, cell attachment has been significantly inhibited on dextran-modified surfaces even after exposure to water for as long as 2 months. The described dopamine-assisted dextran modification represents a simple and universal method for nonfouling surface preparation and can be potentially applied to improve the performance of various medical devices and materials.
- 13 March 2014
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 30 (11) , 3118-3126
Dopamine-Assisted Deposition of Dextran for Nonfouling Applications
Nonfouling surfaces are essential for many biomedical applications, such as diagnostic biosensors and blood- or tissue-contacting implants. In this study, we demonstrate a simple one-step method to introduce dextran onto various substrates based on dopamine polymerization. It has been shown for the first time that dextran molecules could be incorporated into a dopamine polymerization product via mixing dextran with dopamine in a slightly alkaline solution. The codeposited film was characterized by X-ray photoelectron spectroscopy (XPS), the water contact angle, ellipsometry, and atomic force microscopy (AFM). Results reveal that it is possible to control the thickness and surface roughness via the deposition time and deposition repeat cycles. Furthermore, quartz crystal microbalance (QCM) measurements show that the dextran-modified surface inhibits protein adhesion. In addition, cell attachment has been significantly inhibited on dextran-modified surfaces even after exposure to water for as long as 2 months. The described dopamine-assisted dextran modification represents a simple and universal method for nonfouling surface preparation and can be potentially applied to improve the performance of various medical devices and materials.