Sajay Bhuvanendran Nair Gourikutty
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sajay Bhuvanendran Nair Gourikutty has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
Chia-Pin Chang
BioElectronics Programme, Institute of Microelectronics, A*STAR (Agency for Science, Technology and Research), 2 Fusionopolis Way, #08-02, Innovis, 117528, Singapore
3 shared publicationsPoenar Daniel Puiu
NOVITAS-Centre for Micro-/Nano-electronics, School of Electrical and Electronics Engineering, Nanyang Technological University, 50 Nanyang Avenue, 639798, Singapore
3 shared publications- Yunxiao Liu
Nanjing University of Aeronautics and Astronautics
3 shared publications Abdur Rub Abdur Rahman
A*STAR (Agency for Science, Technology and Research)
2 shared publicationsHamizah Ahmad
A*STAR (Agency for Science, Technology and Research)
2 shared publications- Qasem Ramadan
College of Science & General Studies, Alfaisal University, Riyadh 11533, Saudi Arabia
2 shared publications
Latest Publications
- Open Access
- 31 May 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (6) , 565
OOCHIP: Compartmentalized Microfluidic Perfusion System with Porous Barriers for Enhanced Cell–Cell Crosstalk in Organ-on-a-Chip
Improved in vitro models of human organs for predicting drug efficacy, interactions, and disease modelling are crucially needed to minimize the use of animal models, which inevitably display significant differences from the human disease state and metabolism. Inside the body, cells are organized either in direct contact or in close proximity to other cell types in a tightly controlled architecture that regulates tissue function. To emulate this cellular interface in vitro, an advanced cell culture system is required. In this paper, we describe a set of compartmentalized silicon-based microfluidic chips that enable co-culturing several types of cells in close proximity with enhanced cell–cell interaction. In vivo-like fluid flow into and/or from each compartment, as well as between adjacent compartments, is maintained by micro-engineered porous barriers. This porous structure provides a tool for mimicking the paracrine exchange between cells in the human body. As a demonstrating example, the microfluidic system was tested by culturing human adipose tissue that is infiltrated with immune cells to study the role if the interplay between the two cells in the context of type 2 diabetes. However, the system provides a platform technology for mimicking the structure and function of single- and multi-organ models, which could significantly narrow the gap between in vivo and in vitro conditions.
- 31 May 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (6) , 565
Open AccessOOCHIP: Compartmentalized Microfluidic Perfusion System with Porous Barriers for Enhanced Cell–Cell Crosstalk in Organ-on-a-Chip
Improved in vitro models of human organs for predicting drug efficacy, interactions, and disease modelling are crucially needed to minimize the use of animal models, which inevitably display significant differences from the human disease state and metabolism. Inside the body, cells are organized either in direct contact or in close proximity to other cell types in a tightly controlled architecture that regulates tissue function. To emulate this cellular interface in vitro, an advanced cell culture system is required. In this paper, we describe a set of compartmentalized silicon-based microfluidic chips that enable co-culturing several types of cells in close proximity with enhanced cell–cell interaction. In vivo-like fluid flow into and/or from each compartment, as well as between adjacent compartments, is maintained by micro-engineered porous barriers. This porous structure provides a tool for mimicking the paracrine exchange between cells in the human body. As a demonstrating example, the microfluidic system was tested by culturing human adipose tissue that is infiltrated with immune cells to study the role if the interplay between the two cells in the context of type 2 diabetes. However, the system provides a platform technology for mimicking the structure and function of single- and multi-organ models, which could significantly narrow the gap between in vivo and in vitro conditions.
- 22 November 2017
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 27 (12) , 124004
Optimization of micro-fabricated porous membranes for intestinal epithelial cell culture and in vitro modeling of the human intestinal barrier
In vitro modeling of organs could provide a controlled platform for studying physiological events and has great potential in the field of pharmaceutical development. Here, we describe the characterization of in vitro modeling of the human intestinal barrier mimicked using silicon porous membranes as a substrate. To mimic an intestinal in vivo setup as closely as possible, a porous substrate is required in a dynamic environment for the cells to grow rather than a static setup with an impermeable surface such as a petri dish. In this study, we focus on the detailed characterization of Caco-2 cells cultured on a silicon membrane with different pore sizes as well as the effect of dynamic fluid flow on the model. The porous silicon membrane together with continuous perfusion of liquid applying shear stress on the cells enhances the differentiation of polarized cells by providing access to the both their basal and apical surfaces. Membranes with pore sizes of 0.5–3 µ m were used and a shear stress of ~0.03 dyne cm −2 was created by applying a low flow rate of 20 nl s −1 . By providing these optimized conditions, cells were able to differentiate with columnar morphology, which developed microvilli structures on their apical side and tight junctions between adjacent cells like those in a healthy human intestinal barrier. In this setup, it is possible to study the important cellular functions of the intestine such as transport, absorption and secretion, and thus this model has great potential in drug screening.
- 22 November 2017
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 27 (12) , 124004
Optimization of micro-fabricated porous membranes for intestinal epithelial cell culture and in vitro modeling of the human intestinal barrier
In vitro modeling of organs could provide a controlled platform for studying physiological events and has great potential in the field of pharmaceutical development. Here, we describe the characterization of in vitro modeling of the human intestinal barrier mimicked using silicon porous membranes as a substrate. To mimic an intestinal in vivo setup as closely as possible, a porous substrate is required in a dynamic environment for the cells to grow rather than a static setup with an impermeable surface such as a petri dish. In this study, we focus on the detailed characterization of Caco-2 cells cultured on a silicon membrane with different pore sizes as well as the effect of dynamic fluid flow on the model. The porous silicon membrane together with continuous perfusion of liquid applying shear stress on the cells enhances the differentiation of polarized cells by providing access to the both their basal and apical surfaces. Membranes with pore sizes of 0.5–3 µ m were used and a shear stress of ~0.03 dyne cm −2 was created by applying a low flow rate of 20 nl s −1 . By providing these optimized conditions, cells were able to differentiate with columnar morphology, which developed microvilli structures on their apical side and tight junctions between adjacent cells like those in a healthy human intestinal barrier. In this setup, it is possible to study the important cellular functions of the intestine such as transport, absorption and secretion, and thus this model has great potential in drug screening.
- Open Access
- 21 July 2017
- Published by MDPI AG
LAB ON A CHIP PERFUSION DEVICE FOR CONSTRUCTING MICRO-PHYSIOLOGICAL IN VITRO MODEL OF HUMAN ORGANS
Micro-physiological in vitro models providing in vivo like environment has abundant prospects in the field of drug discovery and monitoring the physiological events. These models are currently achieved in setups like dual compartment cell culture Transwell system in which cells are grown in an insert with a porous membrane. Such in vitro tools are static in nature and therefore cannot simulate fully the in vivo conditions inside body [1]. Using these techniques needs a large amount of cells, reagents and culture media, which makes this a rather expensive approach. These models are also limited with number of simulated parameters, and are dedicated to a particular application [2-3]. In our previous work [4], we have tested an intestinal model using porous silicon membrane with pores of well controlled dimensions. In this study, we are developing a microfluidic-based lab-on-chip platform for studying the interaction of various types of cells by co-culturing them and to use this platform for in vitro modeling of human organs. Here, the processes used in typical cell culture experiments are incorporated in an independent microfluidic platform. We report the characterization and optimization of device designs accomplished by means of in-depth FEA simulations (Fig. 1). The chip is made from silicon substrate, which allows us to create features with well controlled dimensions and the critical structures are realized by Deep reactive-ion etching (DRIE) process. The silicon chip itself is 15 mm wide and 40 mm long, capped with glass by means of anodic bonding which provides a leak proof fluidic system and the fluidic channels are accessed through a polymethyl methacrylate (PMMA) jig (Fig. 3). We have developed different chip designs suitable for diverse applications. The major component of the microfluidic device is a perfusion-based microflouidic structure (Fig. 2) which allows the communication between different cell types as well as facilitates the fluid flow. The cell co-culture (Fig. 4b) is achieved by growing them in discrete chambers separated by porous barriers which forms the perfusion structure. The perfusion channels provide opening ranging from 4 to 30 µm2 optimized based on the function of each chamber. This platform provides dynamic environment by precisely controlling the flow rate, spatiotemporal gradients, mechanical stress by fluid flow etc. which enable us to mimic the tissue structure and functions with better physiological relevance. This Organ-on-a-chip design can offer several cell culture chambers with either identical or different cellular structures to study the role of each cell type as well as to compare the cell response to various chemical exposures in parallel experiments.
- 21 July 2017
- Published by MDPI AG
Open AccessLAB ON A CHIP PERFUSION DEVICE FOR CONSTRUCTING MICRO-PHYSIOLOGICAL IN VITRO MODEL OF HUMAN ORGANS
Micro-physiological in vitro models providing in vivo like environment has abundant prospects in the field of drug discovery and monitoring the physiological events. These models are currently achieved in setups like dual compartment cell culture Transwell system in which cells are grown in an insert with a porous membrane. Such in vitro tools are static in nature and therefore cannot simulate fully the in vivo conditions inside body [1]. Using these techniques needs a large amount of cells, reagents and culture media, which makes this a rather expensive approach. These models are also limited with number of simulated parameters, and are dedicated to a particular application [2-3]. In our previous work [4], we have tested an intestinal model using porous silicon membrane with pores of well controlled dimensions. In this study, we are developing a microfluidic-based lab-on-chip platform for studying the interaction of various types of cells by co-culturing them and to use this platform for in vitro modeling of human organs. Here, the processes used in typical cell culture experiments are incorporated in an independent microfluidic platform. We report the characterization and optimization of device designs accomplished by means of in-depth FEA simulations (Fig. 1). The chip is made from silicon substrate, which allows us to create features with well controlled dimensions and the critical structures are realized by Deep reactive-ion etching (DRIE) process. The silicon chip itself is 15 mm wide and 40 mm long, capped with glass by means of anodic bonding which provides a leak proof fluidic system and the fluidic channels are accessed through a polymethyl methacrylate (PMMA) jig (Fig. 3). We have developed different chip designs suitable for diverse applications. The major component of the microfluidic device is a perfusion-based microflouidic structure (Fig. 2) which allows the communication between different cell types as well as facilitates the fluid flow. The cell co-culture (Fig. 4b) is achieved by growing them in discrete chambers separated by porous barriers which forms the perfusion structure. The perfusion channels provide opening ranging from 4 to 30 µm2 optimized based on the function of each chamber. This platform provides dynamic environment by precisely controlling the flow rate, spatiotemporal gradients, mechanical stress by fluid flow etc. which enable us to mimic the tissue structure and functions with better physiological relevance. This Organ-on-a-chip design can offer several cell culture chambers with either identical or different cellular structures to study the role of each cell type as well as to compare the cell response to various chemical exposures in parallel experiments.
- Open Access
- 21 July 2017
- Published by MDPI AG
In vitro micro-physiological models for predictive toxicology and disease modelling
Organotypic culture of human tissue has a great potential to bridge the existing gap between in vivo and in vitro studies and to enable in-depth study of disease pathogenesis and therapy with low cost. Recent advances in microfluidic-based co-cell culture have enabled the realization of physiologically relevant in vitro models of specific human tissues. These systems have been used to study the contribution of micro-environmental factors to cellular morphogenesis in health and disease states, therefore, can be used to answer fundamental biological questions and develop a reliable alternative to animal models, and enable screening of potential new drug compounds. In this paper, we will discuss three immune competent micro-physiological models, namely the human gastrointestinal tract1, the human epidermis2 and the adipose tissue3, the interaction of immune cells with these tissues and their role in inflammation. We will emphasis on the interaction between the adipocytes and immune cells to highlight the role of immune cell infiltration in the adipose tissue in the pathogenesis of diabetes type 2. A three-dimensional perfusion-based microfluidic system has been realized and utilized to host the three biological models. It enables co-culturing of two different types of cells that are physically separated but fluidically and chemically connected which enables the exchange of paracrine signals between the two cell types. The co-culture was maintained viable for more than three weeks during which cells were differentiated such that their phenotypes, morphologically and functionally, resemble the corresponding cells in the human tissue. Inflammation was induced in the biological system, and the response of the co-culture was detected. The biological models have been characterized in both health and disease states. Various commercial drugs are being tested to evaluate the in vitro system response. References Qasem Ramadan and Lin Jing. Characterization of tight junction disruption and immune response modulation in a miniaturized Caco-2/U937 coculture-based in vitro model of the human intestinal barrier, Biomedical Microdevices, 2016,18(1):11. Qasem Ramadan and Fiona Chia Wan Ting. In vitro micro-physiological immune-competent model of human skin. Lab Chip, 2016,16, 1899-1908. Yunxiao Liu, Patthara Kongsuphol, Sajay Bhuvanendran Nair Gourikutty, Qasem Ramadan. Human adipocyte differentiation and characterization in a perfusion-based cell culture device. Biomedical microdevices, Accepted. Acknowledgment This research was supported by the Agency for Science, Technology and Research (A*STAR) (Grant number: 1431AFG123).
- 21 July 2017
- Published by MDPI AG
Open AccessIn vitro micro-physiological models for predictive toxicology and disease modelling
Organotypic culture of human tissue has a great potential to bridge the existing gap between in vivo and in vitro studies and to enable in-depth study of disease pathogenesis and therapy with low cost. Recent advances in microfluidic-based co-cell culture have enabled the realization of physiologically relevant in vitro models of specific human tissues. These systems have been used to study the contribution of micro-environmental factors to cellular morphogenesis in health and disease states, therefore, can be used to answer fundamental biological questions and develop a reliable alternative to animal models, and enable screening of potential new drug compounds. In this paper, we will discuss three immune competent micro-physiological models, namely the human gastrointestinal tract1, the human epidermis2 and the adipose tissue3, the interaction of immune cells with these tissues and their role in inflammation. We will emphasis on the interaction between the adipocytes and immune cells to highlight the role of immune cell infiltration in the adipose tissue in the pathogenesis of diabetes type 2. A three-dimensional perfusion-based microfluidic system has been realized and utilized to host the three biological models. It enables co-culturing of two different types of cells that are physically separated but fluidically and chemically connected which enables the exchange of paracrine signals between the two cell types. The co-culture was maintained viable for more than three weeks during which cells were differentiated such that their phenotypes, morphologically and functionally, resemble the corresponding cells in the human tissue. Inflammation was induced in the biological system, and the response of the co-culture was detected. The biological models have been characterized in both health and disease states. Various commercial drugs are being tested to evaluate the in vitro system response. References Qasem Ramadan and Lin Jing. Characterization of tight junction disruption and immune response modulation in a miniaturized Caco-2/U937 coculture-based in vitro model of the human intestinal barrier, Biomedical Microdevices, 2016,18(1):11. Qasem Ramadan and Fiona Chia Wan Ting. In vitro micro-physiological immune-competent model of human skin. Lab Chip, 2016,16, 1899-1908. Yunxiao Liu, Patthara Kongsuphol, Sajay Bhuvanendran Nair Gourikutty, Qasem Ramadan. Human adipocyte differentiation and characterization in a perfusion-based cell culture device. Biomedical microdevices, Accepted. Acknowledgment This research was supported by the Agency for Science, Technology and Research (A*STAR) (Grant number: 1431AFG123).
- 29 March 2017
- Published by Springer Nature in Biomedical Microdevices
- Vol. 19 (3) , 1-10
Human adipocyte differentiation and characterization in a perfusion-based cell culture device
Adipocytes have gained significant attention recently, because they are not only functioning as energy storage but also as endocrine cells. Adipocytes secret various signaling molecules, including adiponectin, MCP-1, and IL-6, termed collectively as “adipokines”. Adipokines regulate glucose metabolism, thereby play an important role in obesity, diabetes type 2, and other metabolic disorders. Conventionally, to study the secretory function, adipocytes are cultured in vitro in static conditions. However, static culturing condition falls short of mimicking the interstitial fluid flows in living systems. Here, we developed a perfusion device which allows dynamic culture of adipocytes under constant and mild flow using a double-layered fluidic structure. Adipocytes were cultured in the bottom layer while the culture media were constantly flown in the upper layer and perfused through a porous membrane that separate the two chambers. The porous membrane between the two chambers physically separates the cells from the flow stream while maintain a fluidic connection by diffusion. This setting not only provides continuous nutrient supply to adipocytes but also maintains a steady and mild shear stress on the cell membrane. It was found the perfusion-based culture conditions promoted faster growth of primary preadipocytes and stimulated greater adipogenesis compared to static culture condition. Adipocytes cultured under perfusion systems produced more MCP-1 and IL-6, but less adiponectin. When stimulated with TNF-α, adipocytes expressed higher level of MCP-1 and IL-6, but lower level of adiponectin. No significant glucose uptake regulation was observed after treating the adipocytes with insulin in both static and perfusion-based culture. Our results demonstrate that perfusion-base culture has played a role in the adipocyte function particularly the secretion of adipokines. More future studies are required to unveil the mechanisms behind perfusion’s impact on adipocytes.
- 29 March 2017
- Published by Springer Nature in Biomedical Microdevices
- Vol. 19 (3) , 1-10
Human adipocyte differentiation and characterization in a perfusion-based cell culture device
Adipocytes have gained significant attention recently, because they are not only functioning as energy storage but also as endocrine cells. Adipocytes secret various signaling molecules, including adiponectin, MCP-1, and IL-6, termed collectively as “adipokines”. Adipokines regulate glucose metabolism, thereby play an important role in obesity, diabetes type 2, and other metabolic disorders. Conventionally, to study the secretory function, adipocytes are cultured in vitro in static conditions. However, static culturing condition falls short of mimicking the interstitial fluid flows in living systems. Here, we developed a perfusion device which allows dynamic culture of adipocytes under constant and mild flow using a double-layered fluidic structure. Adipocytes were cultured in the bottom layer while the culture media were constantly flown in the upper layer and perfused through a porous membrane that separate the two chambers. The porous membrane between the two chambers physically separates the cells from the flow stream while maintain a fluidic connection by diffusion. This setting not only provides continuous nutrient supply to adipocytes but also maintains a steady and mild shear stress on the cell membrane. It was found the perfusion-based culture conditions promoted faster growth of primary preadipocytes and stimulated greater adipogenesis compared to static culture condition. Adipocytes cultured under perfusion systems produced more MCP-1 and IL-6, but less adiponectin. When stimulated with TNF-α, adipocytes expressed higher level of MCP-1 and IL-6, but lower level of adiponectin. No significant glucose uptake regulation was observed after treating the adipocytes with insulin in both static and perfusion-based culture. Our results demonstrate that perfusion-base culture has played a role in the adipocyte function particularly the secretion of adipokines. More future studies are required to unveil the mechanisms behind perfusion’s impact on adipocytes.
- 1 August 2016
- Published by Elsevier in Journal of Chromatography B
- Vol. 1028, 153-164
An integrated on-chip platform for negative enrichment of tumour cells
- 1 August 2016
- Published by Elsevier in Journal of Chromatography B
- Vol. 1028, 153-164
An integrated on-chip platform for negative enrichment of tumour cells
- 1 February 2016
- Published by Elsevier in Journal of Chromatography B
- Vol. 1011, 77-88
Microfluidic immunomagnetic cell separation from whole blood
- 1 February 2016
- Published by Elsevier in Journal of Chromatography B
- Vol. 1011, 77-88
Microfluidic immunomagnetic cell separation from whole blood
- 27 March 2014
- Published by Springer Nature in Biomedical Microdevices
- Vol. 16 (4) , 537-548
Microfluidic platform for negative enrichment of circulating tumor cells
Negative enrichment is the preferred approach for tumor cell isolation as it does not rely on biomarker expression. However, size-based negative enrichment methods suffer from well-known recovery/purity trade-off. Non-size based methods have a number of processing steps that lead to compounded cell loss due to extensive sample processing and handling which result in a low recovery efficiency. We present a method that performs negative enrichment in two steps from 2 ml of whole blood in a total assay processing time of 60 min. This negative enrichment method employs upstream immunomagnetic depletion to deplete CD45-positive WBCs followed by a microfabricated filter membrane to perform chemical-free RBC depletion and target cells isolation. Experiments of spiking two cell lines, MCF-7 and NCI-H1975, in the whole blood show an average of >90 % cell recovery over a range of spiked cell numbers. We also successfully recovered circulating tumor cells from 15 cancer patient samples.
- 27 March 2014
- Published by Springer Nature in Biomedical Microdevices
- Vol. 16 (4) , 537-548
Microfluidic platform for negative enrichment of circulating tumor cells
Negative enrichment is the preferred approach for tumor cell isolation as it does not rely on biomarker expression. However, size-based negative enrichment methods suffer from well-known recovery/purity trade-off. Non-size based methods have a number of processing steps that lead to compounded cell loss due to extensive sample processing and handling which result in a low recovery efficiency. We present a method that performs negative enrichment in two steps from 2 ml of whole blood in a total assay processing time of 60 min. This negative enrichment method employs upstream immunomagnetic depletion to deplete CD45-positive WBCs followed by a microfabricated filter membrane to perform chemical-free RBC depletion and target cells isolation. Experiments of spiking two cell lines, MCF-7 and NCI-H1975, in the whole blood show an average of >90 % cell recovery over a range of spiked cell numbers. We also successfully recovered circulating tumor cells from 15 cancer patient samples.
- 15 April 2013
- Published by American Association for Cancer Research (AACR)
- Vol. 73, 1451
Abstract 1451: Microfluidic-based unbiased enrichment (negative selection) of circulating non-hematopoietic tumor cells directly from whole blood without centrifugation.
The enumeration and analysis of circulating non-hematopoietic tumor cells (CTCs) is of increasing interest for monitoring disease progression or response to treatment, specifically as a companion diagnostic for new anti-cancer drugs, and for research into the mechanisms of disease progression and metastases. Ideally, CTCs would be enriched from very small samples, with minimal handling, high recovery, and no requirement for the expression of specific surface markers.
- 15 April 2013
- Published by American Association for Cancer Research (AACR)
- Vol. 73, 1451
Abstract 1451: Microfluidic-based unbiased enrichment (negative selection) of circulating non-hematopoietic tumor cells directly from whole blood without centrifugation.
The enumeration and analysis of circulating non-hematopoietic tumor cells (CTCs) is of increasing interest for monitoring disease progression or response to treatment, specifically as a companion diagnostic for new anti-cancer drugs, and for research into the mechanisms of disease progression and metastases. Ideally, CTCs would be enriched from very small samples, with minimal handling, high recovery, and no requirement for the expression of specific surface markers.
- 17 March 2013
- Published by Springer Nature in Biomedical Microdevices
- Vol. 15 (4) , 699-709
Towards an optimal and unbiased approach for tumor cell isolation
Our current understanding of clinical significance or the lack thereof of circulating tumor cells (CTCs) is biased by the technology used to isolate these rare cells. Despite the presence of a vast number of academic and commercial technologies, the lack of a standardized and optimized platform has been widely noted. We present a negative enrichment approach, integrating WBC depletion and chemical-free RBC depletion in the same setup without the need for centrifugation, washing or multiple sample handling steps. This approach achieves an average of >90 % recovery of spiked tumor cells and >99 % total WBC depletion in whole blood across multiple cell lines, in a simple and easy-to-use assay. The results presented herein and ongoing improvements aim to fulfill the need for a highly reliable, unbiased, standardized, and optimized CTC isolation platform, using component technologies that are validated for cell isolation.
- 17 March 2013
- Published by Springer Nature in Biomedical Microdevices
- Vol. 15 (4) , 699-709
Towards an optimal and unbiased approach for tumor cell isolation
Our current understanding of clinical significance or the lack thereof of circulating tumor cells (CTCs) is biased by the technology used to isolate these rare cells. Despite the presence of a vast number of academic and commercial technologies, the lack of a standardized and optimized platform has been widely noted. We present a negative enrichment approach, integrating WBC depletion and chemical-free RBC depletion in the same setup without the need for centrifugation, washing or multiple sample handling steps. This approach achieves an average of >90 % recovery of spiked tumor cells and >99 % total WBC depletion in whole blood across multiple cell lines, in a simple and easy-to-use assay. The results presented herein and ongoing improvements aim to fulfill the need for a highly reliable, unbiased, standardized, and optimized CTC isolation platform, using component technologies that are validated for cell isolation.