Angus Z. Lau
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Angus Z. Lau has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Damian J. Tyler
Oxford Centre for Clinical MR Research (OCMR), RDM Cardiovascular Medicine University of Oxford Oxford UK
4 shared publications - Jack J. Miller
The MR Research Centre, Aarhus University, Aarhus, Denmark
3 shared publications Matthew D. Robson
Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, United Kingdom
3 shared publications- Elizabeth M. Tunnicliffe
Division of Cardiovascular Medicine, Radcliffe Department of Medicine, National Institute for Health Research (NIHR) Oxford Biomedical Research Centre (BRC), University of Oxford, Oxford, United Kingdom
1 shared publication Peter J. Koopmans
Nuffield Department of Clinical Neurosciences; Oxford Centre for Functional MRI of the Brain; University of Oxford UK
1 shared publication- Robert Frost
Athinoula A. Martinos Center for Biomedical Imaging Massachusetts General Hospital Charlestown Massachusetts USA
1 shared publication
Latest Publications
- Open Access
- 13 May 2016
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 77 (5) , 1810-1817
Mapping of intracellular pH in the in vivo rodent heart using hyperpolarized [1‐13C]pyruvate
Purpose: To demonstrate the feasibility of mapping intracellular pH within the in vivo rodent heart. Alterations in cardiac acid‐base balance can lead to acute contractile depression and alterations in Ca2+ signaling. The transient reduction in adenosine triphosphate (ATP) consumption and cardiac contractility may be initially beneficial; however, sustained pH changes can be maladaptive, leading to myocardial damage and electrical arrhythmias.Methods: Spectrally selective radiofrequency (RF) pulses were used to excite the and CO2 resonances individually while preserving signal from the injected hyperpolarized [1‐13C]pyruvate. The large flip angle pulses were placed within a three‐dimensional (3D) imaging acquisition, which exploited CA‐mediated label exchange between and CO2. Images at 4.5 × 4.5 × 5 mm3 resolution were obtained in the in vivo rodent heart. The technique was evaluated in healthy rodents scanned at baseline and during high cardiac workload induced by dobutamine infusion.Results: The intracellular pH was measured to be 7.15 ± 0.04 at baseline, and decreased to 6.90 ± 0.06 following 15 min of continuous β‐adrenergic stimulation.Conclusions: Volumetric maps of intracellular pH can be obtained following an injection of hyperpolarized [1‐13C]pyruvate. The new method is anticipated to enable assessment of stress‐inducible ischemia and potential ventricular arrythmogenic substrates within the ischemic heart. Magn Reson Med 77:1810–1817, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
- 13 May 2016
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 77 (5) , 1810-1817
Open AccessMapping of intracellular pH in the in vivo rodent heart using hyperpolarized [1‐13C]pyruvate
Purpose: To demonstrate the feasibility of mapping intracellular pH within the in vivo rodent heart. Alterations in cardiac acid‐base balance can lead to acute contractile depression and alterations in Ca2+ signaling. The transient reduction in adenosine triphosphate (ATP) consumption and cardiac contractility may be initially beneficial; however, sustained pH changes can be maladaptive, leading to myocardial damage and electrical arrhythmias.Methods: Spectrally selective radiofrequency (RF) pulses were used to excite the and CO2 resonances individually while preserving signal from the injected hyperpolarized [1‐13C]pyruvate. The large flip angle pulses were placed within a three‐dimensional (3D) imaging acquisition, which exploited CA‐mediated label exchange between and CO2. Images at 4.5 × 4.5 × 5 mm3 resolution were obtained in the in vivo rodent heart. The technique was evaluated in healthy rodents scanned at baseline and during high cardiac workload induced by dobutamine infusion.Results: The intracellular pH was measured to be 7.15 ± 0.04 at baseline, and decreased to 6.90 ± 0.06 following 15 min of continuous β‐adrenergic stimulation.Conclusions: Volumetric maps of intracellular pH can be obtained following an injection of hyperpolarized [1‐13C]pyruvate. The new method is anticipated to enable assessment of stress‐inducible ischemia and potential ventricular arrythmogenic substrates within the ischemic heart. Magn Reson Med 77:1810–1817, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
- Open Access
- 7 January 2016
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 77 (1) , 151-158
Simultaneous assessment of cardiac metabolism and perfusion using copolarized [1‐13C]pyruvate and 13C‐urea
Purpose: To demonstrate the feasibility of imaging a bolus of co‐polarized [1‐13C]pyruvate and 13C‐urea to simultaneously assess both metabolism and perfusion in the rodent heart.Methods: Copolarized [1‐13C]pyruvate and 13C‐urea was imaged using a multi‐echo, flow‐sensitized spiral pulse sequence. Healthy rats were scanned in a two‐factor factorial design (n = 12 total; metabolism: overnight fasting versus fed with dichloroacetate injection; perfusion: rest versus adenosine stress‐induced hyperemia).Results: Alterations in metabolism were detected by changes in pyruvate metabolism into 13C‐bicarbonate. Statistically independent alterations in perfusion were detected by changes in myocardial pyruvate and urea signals.Conclusion: The new pulse sequence was used to obtain maps of metabolism and perfusion in the rodent heart in a single acquisition. This hyperpolarized 13C imaging test is expected to enable new studies in which the cardiac metabolism/perfusion mismatch can be studied in the acute environment. Magn Reson Med 77:151–158, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine
- 7 January 2016
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 77 (1) , 151-158
Open AccessSimultaneous assessment of cardiac metabolism and perfusion using copolarized [1‐13C]pyruvate and 13C‐urea
Purpose: To demonstrate the feasibility of imaging a bolus of co‐polarized [1‐13C]pyruvate and 13C‐urea to simultaneously assess both metabolism and perfusion in the rodent heart.Methods: Copolarized [1‐13C]pyruvate and 13C‐urea was imaged using a multi‐echo, flow‐sensitized spiral pulse sequence. Healthy rats were scanned in a two‐factor factorial design (n = 12 total; metabolism: overnight fasting versus fed with dichloroacetate injection; perfusion: rest versus adenosine stress‐induced hyperemia).Results: Alterations in metabolism were detected by changes in pyruvate metabolism into 13C‐bicarbonate. Statistically independent alterations in perfusion were detected by changes in myocardial pyruvate and urea signals.Conclusion: The new pulse sequence was used to obtain maps of metabolism and perfusion in the rodent heart in a single acquisition. This hyperpolarized 13C imaging test is expected to enable new studies in which the cardiac metabolism/perfusion mismatch can be studied in the acute environment. Magn Reson Med 77:151–158, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine
- Open Access
- 20 May 2015
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 75 (4) , 1474-1483
Cardiac perfusion imaging using hyperpolarized 13c urea using flow sensitizing gradients
Purpose: To demonstrate the feasibility of imaging the first passage of a bolus of hyperpolarized 13C urea through the rodent heart using flow‐sensitizing gradients to reduce signal from the blood pool.Methods: A flow‐sensitizing bipolar gradient was optimized to reduce the bright signal within the cardiac chambers, enabling improved contrast of the agent within the tissue capillary bed. The gradient was incorporated into a dynamic golden angle spiral 13C imaging sequence. Healthy rats were scanned during rest (n = 3) and under adenosine stress‐induced hyperemia (n = 3).Results: A two‐fold increase in myocardial perfusion relative to rest was detected during adenosine stress‐induced hyperemia, consistent with a myocardial perfusion reserve of two in rodents.Conclusion: The new pulse sequence was used to obtain dynamic images of the first passage of hyperpolarized 13C urea in the rodent heart, without contamination from bright signal within the neighboring cardiac lumen. This probe of myocardial perfusion is expected to enable new hyperpolarized 13C studies in which the cardiac metabolism/perfusion mismatch can be identified. Magn Reson Med, 2015. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. Magn Reson Med 75:1474–1483, 2016. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance.
- 20 May 2015
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 75 (4) , 1474-1483
Open AccessCardiac perfusion imaging using hyperpolarized 13c urea using flow sensitizing gradients
Purpose: To demonstrate the feasibility of imaging the first passage of a bolus of hyperpolarized 13C urea through the rodent heart using flow‐sensitizing gradients to reduce signal from the blood pool.Methods: A flow‐sensitizing bipolar gradient was optimized to reduce the bright signal within the cardiac chambers, enabling improved contrast of the agent within the tissue capillary bed. The gradient was incorporated into a dynamic golden angle spiral 13C imaging sequence. Healthy rats were scanned during rest (n = 3) and under adenosine stress‐induced hyperemia (n = 3).Results: A two‐fold increase in myocardial perfusion relative to rest was detected during adenosine stress‐induced hyperemia, consistent with a myocardial perfusion reserve of two in rodents.Conclusion: The new pulse sequence was used to obtain dynamic images of the first passage of hyperpolarized 13C urea in the rodent heart, without contamination from bright signal within the neighboring cardiac lumen. This probe of myocardial perfusion is expected to enable new hyperpolarized 13C studies in which the cardiac metabolism/perfusion mismatch can be identified. Magn Reson Med, 2015. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. Magn Reson Med 75:1474–1483, 2016. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance.
- Open Access
- 21 March 2014
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 73 (3) , 995-1004
Accelerated human cardiac diffusion tensor imaging using simultaneous multislice imaging
Purpose To demonstrate the feasibility of accelerating measurements of cardiac fiber structure using simultaneous multislice (SMS) imaging. Methods SMS excitation with a blipped controlled aliasing (CAIPI) readout was incorporated into a diffusion-encoded stimulated echo pulse sequence to obtain diffusion measurements in three separate slices of the heart (8-mm thickness, 12-mm gap). A novel image entropy-based method for removing image ghosts in blipped CAIPI acquisitions is also introduced that enables SMS imaging of closely spaced slices in the heart. Results The average retained signal-to-noise ratio (SNR) using this acquisition scheme is 70% ± 5%, higher than the standard = 57% SNR penalty with three-fold acceleration. No significant difference was observed in the apparent diffusion coefficient and helix angle diffusion parameters between a time-equivalent conventional single-slice scan and the three-fold accelerated SMS acquisition. A 10% mean bias was observed in fractional anisotropy between single-slice and SMS acquisitions. Conclusion The new sequence was used to obtain high-quality diffusion measurements in three closely spaced cardiac slices in a clinically feasible nine breath-hold examination. The accelerated multiband sequence is anticipated to improve quantitative measurements of cardiac microstructure by reducing the number of breath-holds required for the scan, making it practical to incorporate diffusion tensor measurements within a comprehensive clinical examination. Magn Reson Med 73:995–1004, 2015.
- 21 March 2014
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 73 (3) , 995-1004
Open AccessAccelerated human cardiac diffusion tensor imaging using simultaneous multislice imaging
Purpose To demonstrate the feasibility of accelerating measurements of cardiac fiber structure using simultaneous multislice (SMS) imaging. Methods SMS excitation with a blipped controlled aliasing (CAIPI) readout was incorporated into a diffusion-encoded stimulated echo pulse sequence to obtain diffusion measurements in three separate slices of the heart (8-mm thickness, 12-mm gap). A novel image entropy-based method for removing image ghosts in blipped CAIPI acquisitions is also introduced that enables SMS imaging of closely spaced slices in the heart. Results The average retained signal-to-noise ratio (SNR) using this acquisition scheme is 70% ± 5%, higher than the standard = 57% SNR penalty with three-fold acceleration. No significant difference was observed in the apparent diffusion coefficient and helix angle diffusion parameters between a time-equivalent conventional single-slice scan and the three-fold accelerated SMS acquisition. A 10% mean bias was observed in fractional anisotropy between single-slice and SMS acquisitions. Conclusion The new sequence was used to obtain high-quality diffusion measurements in three closely spaced cardiac slices in a clinically feasible nine breath-hold examination. The accelerated multiband sequence is anticipated to improve quantitative measurements of cardiac microstructure by reducing the number of breath-holds required for the scan, making it practical to incorporate diffusion tensor measurements within a comprehensive clinical examination. Magn Reson Med 73:995–1004, 2015.