Abstract
Purpose: To demonstrate the feasibility of imaging a bolus of co‐polarized [1‐13C]pyruvate and 13C‐urea to simultaneously assess both metabolism and perfusion in the rodent heart.Methods: Copolarized [1‐13C]pyruvate and 13C‐urea was imaged using a multi‐echo, flow‐sensitized spiral pulse sequence. Healthy rats were scanned in a two‐factor factorial design (n = 12 total; metabolism: overnight fasting versus fed with dichloroacetate injection; perfusion: rest versus adenosine stress‐induced hyperemia).Results: Alterations in metabolism were detected by changes in pyruvate metabolism into 13C‐bicarbonate. Statistically independent alterations in perfusion were detected by changes in myocardial pyruvate and urea signals.Conclusion: The new pulse sequence was used to obtain maps of metabolism and perfusion in the rodent heart in a single acquisition. This hyperpolarized 13C imaging test is expected to enable new studies in which the cardiac metabolism/perfusion mismatch can be studied in the acute environment. Magn Reson Med 77:151–158, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine
Funding Information
  • National Institute for Health Research Oxford Biomedical Research Centre Programme
  • British Heart Foundation Fellowship (FS/10/002/28078, FS/14/17/30634)
  • British Heart Foundation Programme (RG/11/9/28921)
  • EPSRC Doctoral Training Centre and Prize Fellowship (EP/M508111/1)

This publication has 34 references indexed in Scilit: