Sundararaj Senthilkumar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sundararaj Senthilkumar has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
S. Karthikeyan
Vel Tech Rangarajan Dr. Sagunthala R&D Institute of Science and Technology
7 shared publications- Bt Kannan
SRM Institute of Science and Technology
5 shared publications - Shung-Wen Kang
Department of Mechanical and Electro-Mechanical Engineering, Tamkang University, New Taipei City 25137, Taiwan
4 shared publications G. Sivakumar
Vel Tech University
3 shared publicationsBudda Thiagarajan Kannan
SRM Institute of Science and Technology
2 shared publicationsDewanshu Deep
Department of Aerospace Engineering, SRM Institute of Science and Technology, Kattankulathur, Kanchipuram, Chennai, India
2 shared publications
Latest Publications
- Open Access
- 29 July 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (8) , 883
Investigating Experimental and Computational Fluid Dynamics of 3D-Printed TPMS and Lattice Porous Structures
This study investigates the capillary performance and wetting behavior of SLA (Stereolithography) 3D-printed porous structures, focusing on TPMS (triply periodic minimal surfaces)-Gyroid, Octet, Diamond, and Isotruss lattice designs. High-speed imaging was used to analyze droplet interactions, including penetration, spreading, and contact angles, with 16 μL water droplets dropping from 30 mm at 0.77 m/s. Results showed variable contact angles, with Isotruss and Octet having higher angles, while Diamond faced measurement challenges due to surface roughness. Numerical simulations of TPMS-Gyroid of 2 mm3 unit cells validated the experimental results, and Diamond, Octet, and Isotruss structures were simulated. Capillary performance was assessed through deionized (DI) water weight–time (w-t) measurements, identifying that the TPMS-Gyroid structure performed adequately. Structures with 4 mm3 unit cells had low capillary performance, excluding them from permeability testing, whereas smaller 2 mm3 structures demonstrated capillary effects but had printability and cleaning issues. Permeability results indicated that Octet performed best, followed by Isotruss, Diamond, and TPMS-Gyroid. Findings emphasize unit cell size, beam thickness, and droplet positioning as key factors in optimizing fluid dynamics for cooling, filtration, and fluid management.
- 29 July 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (8) , 883
Open AccessInvestigating Experimental and Computational Fluid Dynamics of 3D-Printed TPMS and Lattice Porous Structures
This study investigates the capillary performance and wetting behavior of SLA (Stereolithography) 3D-printed porous structures, focusing on TPMS (triply periodic minimal surfaces)-Gyroid, Octet, Diamond, and Isotruss lattice designs. High-speed imaging was used to analyze droplet interactions, including penetration, spreading, and contact angles, with 16 μL water droplets dropping from 30 mm at 0.77 m/s. Results showed variable contact angles, with Isotruss and Octet having higher angles, while Diamond faced measurement challenges due to surface roughness. Numerical simulations of TPMS-Gyroid of 2 mm3 unit cells validated the experimental results, and Diamond, Octet, and Isotruss structures were simulated. Capillary performance was assessed through deionized (DI) water weight–time (w-t) measurements, identifying that the TPMS-Gyroid structure performed adequately. Structures with 4 mm3 unit cells had low capillary performance, excluding them from permeability testing, whereas smaller 2 mm3 structures demonstrated capillary effects but had printability and cleaning issues. Permeability results indicated that Octet performed best, followed by Isotruss, Diamond, and TPMS-Gyroid. Findings emphasize unit cell size, beam thickness, and droplet positioning as key factors in optimizing fluid dynamics for cooling, filtration, and fluid management.
- Open Access
- 7 July 2025
- Published by MDPI AG in Preprints.org
Investigating Experimental and Computational Fluid Dynamics of 3D-Printed TPMS and Lattice Porous Structures
This study investigates the capillary performance and wetting behavior of SLA (Stereolithography) 3D-printed porous structures, focusing on TPMS (Triply Periodic Minimal Surfaces)-Gyroid, Octet, Diamond, and Isotruss lattice designs. High-speed imaging was used to analyze droplet interactions, including penetration, spreading, and contact angles, with 16μl water droplets dropped from 30 mm at 0.77m/s. Results showed variable contact angles, with Isotruss and Octet having higher angles, while Diamond faced measurement challenges due to surface roughness. Numerical simulations of TPMS-Gyroid of 2 mm³ unit cells validated the experimental results and Diamond, Octet, and Isotruss structures were simulated. Capillary performance was assessed through deionized (DI) water weight-time (w-t) measurements, identifying the TPMS-Gyroid structure performed adequately. Structures with 4 mm³ unit cells had low capillary performance, excluding them from permeability testing, whereas smaller 2 mm³ structures demonstrated capillary effects but had printability and cleaning issues. Permeability results indicated that Octet performed best, followed by Isotruss, Diamond, and TPMS-Gyroid. Findings emphasize unit cell size, beam thickness, and droplet positioning as key factors in optimizing fluid dynamics for cooling, filtration, and fluid management.
- 7 July 2025
- Published by MDPI AG in Preprints.org
Open AccessInvestigating Experimental and Computational Fluid Dynamics of 3D-Printed TPMS and Lattice Porous Structures
This study investigates the capillary performance and wetting behavior of SLA (Stereolithography) 3D-printed porous structures, focusing on TPMS (Triply Periodic Minimal Surfaces)-Gyroid, Octet, Diamond, and Isotruss lattice designs. High-speed imaging was used to analyze droplet interactions, including penetration, spreading, and contact angles, with 16μl water droplets dropped from 30 mm at 0.77m/s. Results showed variable contact angles, with Isotruss and Octet having higher angles, while Diamond faced measurement challenges due to surface roughness. Numerical simulations of TPMS-Gyroid of 2 mm³ unit cells validated the experimental results and Diamond, Octet, and Isotruss structures were simulated. Capillary performance was assessed through deionized (DI) water weight-time (w-t) measurements, identifying the TPMS-Gyroid structure performed adequately. Structures with 4 mm³ unit cells had low capillary performance, excluding them from permeability testing, whereas smaller 2 mm³ structures demonstrated capillary effects but had printability and cleaning issues. Permeability results indicated that Octet performed best, followed by Isotruss, Diamond, and TPMS-Gyroid. Findings emphasize unit cell size, beam thickness, and droplet positioning as key factors in optimizing fluid dynamics for cooling, filtration, and fluid management.
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2813 (1)
Numerical prediction of effects of bubble size and altitude on subcooled condensation of vapor bubble using a Eulerian two-fluid phase change model
Numerical simulations on the condensation of vapor bubble of different sizes under three different subcooled conditions for both the sea level and high-altitude Mt. Everest conditions are performed. Two-fluid flow simualtions with two-dimensional assumptions are performed where the source terms due to surface tension, mass transfer and heat transfer are modelled through an added User Defined Function in the Volume of Fluid (VOF) method. The flow field and temperature are predicted through the Finite Volume based numerical solution. The two-fluid interfaces are tracked and advected by using the VOF model along with a Piecewise Linear Interface Construction (PLIC) technique. In order to study the effect of vapor bubble size and altitude on condensation, two bubble diameter values of 3 mm and 5 mm are considered for analysis and the difference in temperature between vapor bubble and surrounding liquid is fixed as 50 K, 70 K and 90 K for both the sea level and Mt. Everest high altitude conditions. Results are presented in terms of temporal bubble evolution during condensation and the respective temperature contours. The results show significant differences in condensation bubble evolution at high altitude as compared to the standard atmospheric pressure which can be explained by the reason that the boiling point of the liquid decreases due to low pressure at high altitudes.
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2813 (1)
Open AccessNumerical prediction of effects of bubble size and altitude on subcooled condensation of vapor bubble using a Eulerian two-fluid phase change model
Numerical simulations on the condensation of vapor bubble of different sizes under three different subcooled conditions for both the sea level and high-altitude Mt. Everest conditions are performed. Two-fluid flow simualtions with two-dimensional assumptions are performed where the source terms due to surface tension, mass transfer and heat transfer are modelled through an added User Defined Function in the Volume of Fluid (VOF) method. The flow field and temperature are predicted through the Finite Volume based numerical solution. The two-fluid interfaces are tracked and advected by using the VOF model along with a Piecewise Linear Interface Construction (PLIC) technique. In order to study the effect of vapor bubble size and altitude on condensation, two bubble diameter values of 3 mm and 5 mm are considered for analysis and the difference in temperature between vapor bubble and surrounding liquid is fixed as 50 K, 70 K and 90 K for both the sea level and Mt. Everest high altitude conditions. Results are presented in terms of temporal bubble evolution during condensation and the respective temperature contours. The results show significant differences in condensation bubble evolution at high altitude as compared to the standard atmospheric pressure which can be explained by the reason that the boiling point of the liquid decreases due to low pressure at high altitudes.
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2813 (1)
Assessment of turbulent models for 2-D 30° bevel C-D nozzle for underexpansion condition
This paper focuses on the comparison between five different turbulent models and to assess the best model for 2-D 30° Bevel C-D nozzle for underexpansion condition (NPR 7.5). Mach 1.76 jet is studied using commercial software package ANSYS FLUENT. Turbulent models used for this investigation are: Spalart-Allmaras, standard k-ɛ, Realizable k-ɛ, SST k-ω, and standard k-ω. From the results obtained, it is reported that k-ω standard is not suited for this problem as jet core length is increased drastically resulting in no entrainment of surrounding mass with the jet. k-ɛ standard is also not suitable for this investigation, although jet core length is less than k-ω standard, the Mach number after some distance downstream is higher than all the models being investigated, indicating less entrainment. As for the Spalart-Allmaras, Realizable k-ɛ, SST k-ω, the results are on par with standard validation, indicating best mixing.
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2813 (1)
Open AccessAssessment of turbulent models for 2-D 30° bevel C-D nozzle for underexpansion condition
This paper focuses on the comparison between five different turbulent models and to assess the best model for 2-D 30° Bevel C-D nozzle for underexpansion condition (NPR 7.5). Mach 1.76 jet is studied using commercial software package ANSYS FLUENT. Turbulent models used for this investigation are: Spalart-Allmaras, standard k-ɛ, Realizable k-ɛ, SST k-ω, and standard k-ω. From the results obtained, it is reported that k-ω standard is not suited for this problem as jet core length is increased drastically resulting in no entrainment of surrounding mass with the jet. k-ɛ standard is also not suitable for this investigation, although jet core length is less than k-ω standard, the Mach number after some distance downstream is higher than all the models being investigated, indicating less entrainment. As for the Spalart-Allmaras, Realizable k-ɛ, SST k-ω, the results are on par with standard validation, indicating best mixing.
- Open Access
Correlations Based on Numerical Validation of Oscillating Flow Regenerator
Stirling regenerator is one of the emerging heat exchanger systems in the area of cryogenic cooling. Many kinds of research have been conducted to study the efficiency of Stirling regenerators. Therefore, the principles and related knowledge of Stirling refrigerators must be thoroughly understood to design a regenerator with excellent performance for low-temperature and cryogenic engineering applications. In this study, an experimental setup is developed to estimate the pressure drop of the oscillating flow through two different wire-mesh regenerators, namely, 200 mesh and 300 mesh, for various operating frequencies ranging from 3 (200 RPM) to 10 Hz (600 RPM). Transient, axisymmetric, incompressible, and laminar flow governing equations are solved numerically, and source terms are added in the governing equations with the help of the porous media model and the Ergun semiempirical correlation, assuming that the wire meshes are cylindrical particles arranged uniformly. Simulation results show that the numerical predictions of temporal pressure variation are in reasonably good agreement with those of experimental findings. It is also found that the Ergun correlation works more accurately for higher flow rate conditions.
Open AccessCorrelations Based on Numerical Validation of Oscillating Flow Regenerator
Stirling regenerator is one of the emerging heat exchanger systems in the area of cryogenic cooling. Many kinds of research have been conducted to study the efficiency of Stirling regenerators. Therefore, the principles and related knowledge of Stirling refrigerators must be thoroughly understood to design a regenerator with excellent performance for low-temperature and cryogenic engineering applications. In this study, an experimental setup is developed to estimate the pressure drop of the oscillating flow through two different wire-mesh regenerators, namely, 200 mesh and 300 mesh, for various operating frequencies ranging from 3 (200 RPM) to 10 Hz (600 RPM). Transient, axisymmetric, incompressible, and laminar flow governing equations are solved numerically, and source terms are added in the governing equations with the help of the porous media model and the Ergun semiempirical correlation, assuming that the wire meshes are cylindrical particles arranged uniformly. Simulation results show that the numerical predictions of temporal pressure variation are in reasonably good agreement with those of experimental findings. It is also found that the Ergun correlation works more accurately for higher flow rate conditions.
- Open Access
Study of Gas-to-Liquid Heat Pipe Heat Exchanger
This study is focused on the study and development of a gas-to-liquid heat pipe heat exchanger (HPHE) based on numerical and experimental analysis. Stainless steel heat pipes were installed inside the heat exchanger in the form of three equilateral triangles, staggered into a hexagonal configuration to simulate the waste heat recovery from hot exhaust gas to a water flow. The first main aim of this study was focused on 3D design and numerical analysis, which were used to create and calculate the effect of similar input conditions on the overall system. The system was tested for the overall heat transfer by measuring the temperature change in both fluids. The heat transfer and overall average temperature were used to calculate the effectiveness of the system. In the second part of this study, a test of the waste heat recovery was undertaken with this setup, using water as the cooling fluid. The study was conducted with different input velocities and temperatures of waste hot air, controlled simultaneously by the input fan and air heater, whereas the cooling water was kept at a steady state of 30 °C and 0.0156 kg/s at the input. The hot air velocity was controlled by fans with different inlet air velocities of 0.3 m/s, 0.5 m/s, and 0.7 m/s. Moreover, the temperature of the air was changed from 150 °C to 250 °C with a step of 25 °C. The increase in temperature and the velocity of air was directly proportional to the amount of heat transferred from the air to the cooling water, and the effectiveness was also found to be inversely proportional to both of the varying input parameters. The numerical study showed a maximum increase of 12% in the heat transfer. The output temperatures of hot and cold fluids showed maximum increases of 7 K and 3 K, respectively. The numerical system with such input parameters can be evaluated further to predict the behavior of changes in the design and parameters.
Open AccessStudy of Gas-to-Liquid Heat Pipe Heat Exchanger
This study is focused on the study and development of a gas-to-liquid heat pipe heat exchanger (HPHE) based on numerical and experimental analysis. Stainless steel heat pipes were installed inside the heat exchanger in the form of three equilateral triangles, staggered into a hexagonal configuration to simulate the waste heat recovery from hot exhaust gas to a water flow. The first main aim of this study was focused on 3D design and numerical analysis, which were used to create and calculate the effect of similar input conditions on the overall system. The system was tested for the overall heat transfer by measuring the temperature change in both fluids. The heat transfer and overall average temperature were used to calculate the effectiveness of the system. In the second part of this study, a test of the waste heat recovery was undertaken with this setup, using water as the cooling fluid. The study was conducted with different input velocities and temperatures of waste hot air, controlled simultaneously by the input fan and air heater, whereas the cooling water was kept at a steady state of 30 °C and 0.0156 kg/s at the input. The hot air velocity was controlled by fans with different inlet air velocities of 0.3 m/s, 0.5 m/s, and 0.7 m/s. Moreover, the temperature of the air was changed from 150 °C to 250 °C with a step of 25 °C. The increase in temperature and the velocity of air was directly proportional to the amount of heat transferred from the air to the cooling water, and the effectiveness was also found to be inversely proportional to both of the varying input parameters. The numerical study showed a maximum increase of 12% in the heat transfer. The output temperatures of hot and cold fluids showed maximum increases of 7 K and 3 K, respectively. The numerical system with such input parameters can be evaluated further to predict the behavior of changes in the design and parameters.
- Open Access
- 1 April 2021
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1130 (1) , 012074
A Comparative Study on Aerodynamic Drag Reduction of a Blunt Nose Body using Aerospike and Aerodisk – Numerical Approach
A spike attached to a hemispherical body drastically changes its flow field and influences aerodynamic drag in supersonic and hypersonic flow. It is, therefore a potential candidate for drag reduction of a future high-speed vehicle. The effect of spike nose configuration and angle of attack on the reduction of drag is studied. The studies show that the aerodisk is superior to the aerospike. The aerodisk of appropriate length, diameter and nose configuration may have the capability for the drag reduction. Design criteria is studied and the aerodisk attached to the blunt nose body are designed using CATIA. Numerical solutions are obtained using a commercial CFD software ANSYS-Fluent. Flow observations on the blunt body with a conical, hemispherical aerodisk and flat-faced aerodisk are carried out at Mach number of 2. The flow fields show different flow features between the conical spike, the hemispherical aerodisk and the flat-faced aerodisk. The effects of the aerospike and aerodisk on the lift and drag coefficient are studied. Finally, it is found that A forward-facing spike attached to a hemispherical body alters significantly the structure of the flow field and serves to reduce drag by the formation of a recirculation region around the stagnation point of the blunt body. The flow field, immediately behind the aerodisk shows a complex flow field due to back-disk geometry as compared to the conical spike. To take advantage of the forward-facing spike for more efficient drag reduction, the reattachment point of the shear layer on the body should be moved backward by choosing the optimal spike length with suitable geometrical configuration of the nose.
- 1 April 2021
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1130 (1) , 012074
Open AccessA Comparative Study on Aerodynamic Drag Reduction of a Blunt Nose Body using Aerospike and Aerodisk – Numerical Approach
A spike attached to a hemispherical body drastically changes its flow field and influences aerodynamic drag in supersonic and hypersonic flow. It is, therefore a potential candidate for drag reduction of a future high-speed vehicle. The effect of spike nose configuration and angle of attack on the reduction of drag is studied. The studies show that the aerodisk is superior to the aerospike. The aerodisk of appropriate length, diameter and nose configuration may have the capability for the drag reduction. Design criteria is studied and the aerodisk attached to the blunt nose body are designed using CATIA. Numerical solutions are obtained using a commercial CFD software ANSYS-Fluent. Flow observations on the blunt body with a conical, hemispherical aerodisk and flat-faced aerodisk are carried out at Mach number of 2. The flow fields show different flow features between the conical spike, the hemispherical aerodisk and the flat-faced aerodisk. The effects of the aerospike and aerodisk on the lift and drag coefficient are studied. Finally, it is found that A forward-facing spike attached to a hemispherical body alters significantly the structure of the flow field and serves to reduce drag by the formation of a recirculation region around the stagnation point of the blunt body. The flow field, immediately behind the aerodisk shows a complex flow field due to back-disk geometry as compared to the conical spike. To take advantage of the forward-facing spike for more efficient drag reduction, the reattachment point of the shear layer on the body should be moved backward by choosing the optimal spike length with suitable geometrical configuration of the nose.
- Open Access
- 1 December 2020
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 993 (1) , 012146
Prediction of Aerodynamic Performance of Axial Fan with Leading Edge Serration using Computation Fluid Dynamics
Axial fans are found to be one of the major sources of the noise in modern devices such as PCs, HVAC systems, turbo engines and etc. Lot of researches were going on for decades to reduce this unwanted noise. Researchers have found that application of leading-edge serrations will lead to reduction of noise from the bio-inspired study on the wings of barn-owl. This project involves in the study of effect of Aerodynamic performance of axial fan in terms of pressure drop and aerodynamic efficiency using commercial CFD tool ANSYS FLUENT. Analysis have been carried out for a base model without serration and same model with serrations for various flow rates. The results are validated with the experimental results obtained by Krömer et al [1] and found to be in reasonably good agreement.
- 1 December 2020
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 993 (1) , 012146
Open AccessPrediction of Aerodynamic Performance of Axial Fan with Leading Edge Serration using Computation Fluid Dynamics
Axial fans are found to be one of the major sources of the noise in modern devices such as PCs, HVAC systems, turbo engines and etc. Lot of researches were going on for decades to reduce this unwanted noise. Researchers have found that application of leading-edge serrations will lead to reduction of noise from the bio-inspired study on the wings of barn-owl. This project involves in the study of effect of Aerodynamic performance of axial fan in terms of pressure drop and aerodynamic efficiency using commercial CFD tool ANSYS FLUENT. Analysis have been carried out for a base model without serration and same model with serrations for various flow rates. The results are validated with the experimental results obtained by Krömer et al [1] and found to be in reasonably good agreement.
- Open Access
- 1 December 2020
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 993 (1) , 012150
Numerical Analysis on Improving Transmission Loss of Reactive Muffler using Various Sound Absorptive Materials
Finite element analysis approach is used to determine the transmission loss for an optimized geometry of reactive multi-chamber muffler. The pressure acoustics theory is involved in the present problem and it examines the wave nature of sound and also the intensity with which it propagates. COMSOL Multiphysics software was used for modelling and analysis. The acoustics module with parallel study in frequency domain was utilized to study the flow and acoustic behaviour of the reactive muffler. Various absorptive liner materials were considered for the muffler and the transmission losses were compared. In addition to the above, the thickness of liner and inlet pressure were varied in order to have profound work for discussion. The validation of predicted transmission loss is in good agreement with the referred experimental data. The result for different types of absorptive liner materials was tracked in comparison with the muffler without liner. The average transmission loss was found to be increased by 8% with the introduction of absorptive liner with 10mm thickness. Finally, the calculated sound pressure level with total acoustic pressure field and streamlines intensity provide insight of the physics involved.
- 1 December 2020
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 993 (1) , 012150
Open AccessNumerical Analysis on Improving Transmission Loss of Reactive Muffler using Various Sound Absorptive Materials
Finite element analysis approach is used to determine the transmission loss for an optimized geometry of reactive multi-chamber muffler. The pressure acoustics theory is involved in the present problem and it examines the wave nature of sound and also the intensity with which it propagates. COMSOL Multiphysics software was used for modelling and analysis. The acoustics module with parallel study in frequency domain was utilized to study the flow and acoustic behaviour of the reactive muffler. Various absorptive liner materials were considered for the muffler and the transmission losses were compared. In addition to the above, the thickness of liner and inlet pressure were varied in order to have profound work for discussion. The validation of predicted transmission loss is in good agreement with the referred experimental data. The result for different types of absorptive liner materials was tracked in comparison with the muffler without liner. The average transmission loss was found to be increased by 8% with the introduction of absorptive liner with 10mm thickness. Finally, the calculated sound pressure level with total acoustic pressure field and streamlines intensity provide insight of the physics involved.
- 15 September 2020
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 147 (1) , 711-726
Numerical heat transfer analysis and development of a heat removal system for an unshaded parked car in sunny day: computational fluid dynamics study
- 15 September 2020
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 147 (1) , 711-726
Numerical heat transfer analysis and development of a heat removal system for an unshaded parked car in sunny day: computational fluid dynamics study