Correlations Based on Numerical Validation of Oscillating Flow Regenerator
Open Access
Abstract
Stirling regenerator is one of the emerging heat exchanger systems in the area of cryogenic cooling. Many kinds of research have been conducted to study the efficiency of Stirling regenerators. Therefore, the principles and related knowledge of Stirling refrigerators must be thoroughly understood to design a regenerator with excellent performance for low-temperature and cryogenic engineering applications. In this study, an experimental setup is developed to estimate the pressure drop of the oscillating flow through two different wire-mesh regenerators, namely, 200 mesh and 300 mesh, for various operating frequencies ranging from 3 (200 RPM) to 10 Hz (600 RPM). Transient, axisymmetric, incompressible, and laminar flow governing equations are solved numerically, and source terms are added in the governing equations with the help of the porous media model and the Ergun semiempirical correlation, assuming that the wire meshes are cylindrical particles arranged uniformly. Simulation results show that the numerical predictions of temporal pressure variation are in reasonably good agreement with those of experimental findings. It is also found that the Ergun correlation works more accurately for higher flow rate conditions.Keywords
Funding Information
- The Ministry of Science and Technology, Taiwan, Republic of China (MOST 107-2622-E-006-005-CC2)
This publication has 36 references indexed in Scilit:
- Friction factor, permeability and inertial coefficient of oscillating flow through porous media of packed ballsExperimental Thermal and Fluid Science, 2012
- Using computational fluid dynamics simulations to determine pressure drops on woven screensBiosystems Engineering, 2010
- Numerical Modeling of Laminar Pulsating Flow in Porous MediaJournal of Fluids Engineering, 2009
- Heat transfer characteristics of oscillating flow regenerator filled with circular tubes or parallel platesCryogenics, 2007
- Characteristics of oscillating flow through a channel filled with open-cell metal foamInternational Journal of Heat and Fluid Flow, 2006
- Investigation of oscillating flow friction factor for cryocooler regenerator considering cryogenic temperature effectCryogenics, 2005
- Novel flow analysis of regenerator under oscillating flow with pulsating pressureCryogenics, 2005
- Airflow through porous screens: From theory to practical considerationsEnergy and Buildings, 1998
- Pulsating flow and heat transfer in a pipe partially filled with a porous mediumInternational Journal of Heat and Mass Transfer, 1997
- Miniature stirling cycle coolerCryogenics, 1987