XDXuedong Deng

Xuedong Deng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xuedong Deng has a total of 93 co-authors. Here are the top co-authors by number of shared publications:

  • Linliang Yin

    Center for Medical Ultrasound, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Suzhou, China

    9 shared publications
  • Zhong Yang

    The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou, China

    7 shared publications
  • Qi Pan

    Center for Medical Ultrasound, Suzhou Municipal Hospital, Gusu School, The Affiliated Suzhou Hospital of Nanjing Medical University, Nanjing Medical University, Suzhou, China

    6 shared publications
  • Chunya Ji

    Center for Medical Ultrasound, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Suzhou, PR China

    5 shared publications
  • Jun Zhang

    Center for Medical Ultrasound, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Gusu School, Nanjing Medical University, 215002 Suzhou, Jiangsu, China

    5 shared publications
  • Chen Ling

    The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou, China

    4 shared publications

Latest Publications

  • Open Access

    Artificial intelligence for detecting fetal orofacial clefts and advancing medical education

    by Yuanji Zhang, Yuhao Huang, Haoran Dou, Xiliang Zhu, Chen Ling, Zhong Yang, Lianying Liang, Jiuping Li, Siying Liang, Rui Li, et al.

    Orofacial clefts are among the most common congenital craniofacial abnormalities, yet accurate prenatal detection remains challenging due to the scarcity of experienced specialists and the relative rarity of the condition. Early and reliable diagnosis is essential to enable timely clinical intervention and reduce associated morbidity. Here we show that an artificial intelligence system, trained on over 45,139 ultrasound images from 9,215 fetuses across 22 hospitals, can diagnose fetal orofacial clefts with sensitivity and specificity exceeding 93% and 95% respectively, matching the performance of senior radiologists and substantially outperforming junior radiologists. When used as a medical copilot, the system raises junior radiologists’ sensitivity by more than 6 %. Beyond direct diagnostic assistance, the system also accelerates the development of clinical expertise. A pilot study involving 24 radiologists and trainees demonstrated that the model can improve the expertise development for rare conditions. This dual-purpose approach offers a scalable solution for improving both diagnostic accuracy and specialist training in settings where experienced radiologists are scarce.


  • Open Access

    Predictive models for adverse pregnancy outcomes in fetal growth restriction: a systematic review and meta-analysis

    by Jihong Peng, Yingqi Fang, Wenzhuo Shen, Jinyang Hu, Xuedong Deng, Linliang Yin

    We aim to conduct a systematic review and meta-analysis to evaluate the performance of existing predictive models for adverse pregnancy outcomes in pregnan


  • Deep Learning Model for Real-Time Nuchal Translucency Assessment at Prenatal US

    by Yuanji Zhang, Xin Yang, Chunya Ji, Xindi Hu, Yan Cao, Chaoyu Chen, He Sui, Binghan Li, Chaojiong Zhen, Weijun Huang, et al.

    The Automated Identification and Measurement of Nuchal Translucency model for nuchal translucency assessment demonstrated high diagnostic accuracy and closely matched radiologist workflow patterns in real-time US diagnostics.


  • Open Access

    FetalFlex: Anatomy-Guided Diffusion Model for Flexible Control on Fetal Ultrasound Image Synthesis

    by Yaofei Duan, Tao Tan, Zhiyuan Zhu, Yuhao Huang, Yuanji Zhang, Rui Gao, Patrick Cheong-Iao Pang, Xinru Gao, Guowei Tao, Xiang Cong, et al.

    Fetal ultrasound (US) examinations require the acquisition of multiple planes, each providing unique diagnostic information to evaluate fetal development and screening for congenital anomalies. However, obtaining a comprehensive, multi-plane annotated fetal US dataset remains challenging, particularly for rare or complex anomalies owing to their low incidence and numerous subtypes. This poses difficulties in training novice radiologists and developing robust AI models, especially for detecting abnormal fetuses. In this study, we introduce a Flexible Fetal US image generation framework (FetalFlex) to address these challenges, which leverages anatomical structures and multimodal information to enable controllable synthesis of fetal US images across diverse planes. Specifically, FetalFlex incorporates a pre-alignment module to enhance controllability and introduces a repaint strategy to ensure consistent texture and appearance. Moreover, a two-stage adaptive sampling strategy is developed to progressively refine image quality from coarse to fine levels. We believe that FetalFlex is the first method capable of generating both in-distribution normal and out-of-distribution abnormal fetal US images, without requiring any abnormal data. Experiments on multi-center datasets demonstrate that FetalFlex achieved state-of-the-art performance across multiple image quality metrics. A reader study further confirms the close alignment of the generated results with expert visual assessments. Furthermore, synthetic images by FetalFlex significantly improve the performance of six typical deep models in downstream classification and anomaly detection tasks. Lastly, FetalFlex's anatomy-level controllable generation offers a unique advantage for anomaly simulation and creating paired or counterfactual data at the pixel level. The demo is available at: https://dyf1023.github.io/FetalFlex/.

  • Open Access

    A novel artificial intelligence model for fetal facial profile marker measurement during the first trimester

    by Chunya Ji, Kai Liu, Xin Yang, Yan Cao, Xiaoju Cao, Qi Pan, Zhong Yang, Lingling Sun, Linliang Yin, Xuedong Deng, et al.

    Background: To study the validity of an artificial intelligence (AI) model for measuring fetal facial profile markers, and to evaluate the clinical value of the AI model for identifying fetal abnormalities during the first trimester. Methods: This retrospective study used two-dimensional mid-sagittal fetal profile images taken during singleton pregnancies at 11–13+ 6 weeks of gestation. We measured the facial profile markers, including inferior facial angle (IFA), maxilla-nasion-mandible (MNM) angle, facial-maxillary angle (FMA), frontal space (FS) distance, and profile line (PL) distance using AI and manual measurements. Semantic segmentation and landmark localization were used to develop an AI model to measure the selected markers and evaluate the diagnostic value for fetal abnormalities. The consistency between AI and manual measurements was compared using intraclass correlation coefficients (ICC). The diagnostic value of facial markers measured using the AI model during fetal abnormality screening was evaluated using receiver operating characteristic (ROC) curves. Results: A total of 2372 normal fetuses and 37 with abnormalities were observed, including 18 with trisomy 21, 7 with trisomy 18, and 12 with CLP. Among them, 1872 normal fetuses were used for AI model training and validation, and the remaining 500 normal fetuses and all fetuses with abnormalities were used for clinical testing. The ICCs (95%CI) of the IFA, MNM angle, FMA, FS distance, and PL distance between the AI and manual measurement for the 500 normal fetuses were 0.812 (0.780–0.840), 0.760 (0.720–0.795), 0.766 (0.727-0.800), 0.807 (0.775–0.836), and 0.798 (0.764–0.828), respectively. IFA clinically significantly identified trisomy 21 and trisomy 18, with areas under the ROC curve (AUC) of 0.686 (95%CI, 0.585–0.788) and 0.729 (95%CI, 0.621–0.837), respectively. FMA effectively predicted trisomy 18, with an AUC of 0.904 (95%CI, 0.842–0.966). MNM angle and FS distance exhibited good predictive value in CLP, with AUCs of 0.738 (95%CI, 0.573–0.902) and 0.677 (95%CI, 0.494–0.859), respectively. Conclusions: The consistency of fetal facial profile marker measurements between the AI and manual measurement was good during the first trimester. The AI model is a convenient and effective tool for the early screen for fetal trisomy 21, trisomy 18, and CLP, which can be generalized to first-trimester scanning (FTS).


  • Open Access

    Standardized First-Trimester Ultrasound Screening for Fetal Structural Abnormalities in A Non-Selective Population: A Single-Center Experience

    by Lingling Sun, Xuedong Deng, Linliang Yin, Jian Sun, Chunya Ji, Qi Pan, Jun Zhang, Zhong Yang, Chen Ling

    Background: To explore the effectiveness of standardized first-trimester ultrasound screening (FTS) in detecting fetal structural abnormalities in a non-selective population. Methods: A retrospective study was performed on 7523 fetuses (6376 single and 569 twin pregnancies) who underwent FTS between 11 and 13+6 weeks’ gestation. All fetuses received anatomy scans using a standardized protocol. Results: 147 fetuses (133 single and 7 twin pregnancies) were lost to follow up. Of the remaining 7376 fetuses, 119 (1.61%, 119/7376) developed structural malformations, with 64 cases (53.8%, 64/119) identified during the first trimester. The remaining cases were detected during the second trimester (24.4%, 29/119), the third trimester (1.68%, 2/119), and postnatally (20.2%, 24/119). There were 4 cases of suspected ventricular septal defect (VSD) by FTS, which were later confirmed to be normal. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for FTS were 54.2%, 99.9%, 94.1%, and 99.3%, respectively. Forty eight fetuses, accounting for 10.6% of the total (452), with thickened nuchal translucency (NT) (above the 95th percentile) showed structural malformations. This was significantly higher than the prevalence of structural abnormalities found in fetuses with normal NT (1.0%, 71/6924) (p < 0.01). Conclusions: Standardized FTS is highly effective in detecting fetal structural malformations early, with impressive specificity, PPV, and NPV. Increased NT suggests detailed anatomy screening and helps guide treatment. However, while standardized FTS is an invaluable tool, it cannot fully replace the sensitivity of second- and third-trimester ultrasound screening. Clinical Trial Registration: The study was registered at https://www.chictr.org.cn (registration number ChiCTR-SOC-17010976).

  • Open Access

    Clinical value of fetal facial profile markers during the first trimester

    by Xiaofeng Zhou, Chunya Ji, Lingling Sun, Linliang Yin, Xuedong Deng, Qi Pan, Jun Zhang, Zhong Yang, Chenhan Zheng, Chen Ling, et al.

    Objectives: To study the correlations between facial profile markers and crown-lump length (CRL) in a Chinese population, and to evaluate the clinical value of these markers for abnormal fetuses during the first trimester (11 to 13+6 gestational weeks). Methods: The facial profile markers were as followings: inferior facial angle (IFA), maxilla-nasion-mandible (MNM) angle, facial maxillary angle (FMA), frontal space (FS) distance and profile line (PL) distance. These markers were measured in facial mid-sagittal section through ViewPoint 6 software. The diagnostic value of these markers for abnormal fetuses was assessed by receiver operating characteristic (ROC) curves. Results: According to the first-trimester scanning (FTS) and follow-up, 31 fetuses were enrolled in the abnormal group, including 14 cases of trisomy 21, 7 cases of trisomy 18, 10 cases with cleft lip and palate (CLP), and 1000 normal fetuses were selected. Among the normal fetuses, the IFA, FS distance and PL distance had negative correlations with CRL. The MNM angle and FMA had positive correlations with CRL. The mean IFA values for fetuses with trisomy 21 and trisomy 18 were 74.11° (standard deviation (SD) 7.48) and 69.88° (SD 7.08), respectively, which were significantly smaller than the normal fetuses (p = 0.013; p = 0.003). The mean MNM angle of fetuses with trisomy 18 and CLP were 6.98° (SD 2.61) and 9.41° (SD 2.57), respectively, which were significantly greater than the normal fetuses (p = 0.005; p < 0.001). The mean FMA values of trisomy 18 fetuses were 63.95° (SD 4.77), which was significantly smaller than the normal fetuses (p < 0.001). The mean FS distance of CLP fetuses was -0.22 mm (SD 1.38), which was significantly smaller than the normal fetuses (p < 0.001). The mean PL distance of trisomy 21, trisomy 18 and CLP fetuses were 2.89 mm (SD 0.41), 2.91 mm (SD 0.56) and 2.71 mm (SD 0.37), respectively. The difference with the normal fetuses had no statistical significance (p = 0.56; p = 0.607; p = 0.54). Conclusions: Fetal facial profile markers had excellent correlations with CRL during the first trimester. IFA had certain clinical significance in detecting trisomy 21. FMA, IFA and MNM angle were reliable indicators for screening trisomy 18. The abnormal MNM angle and FS distance could be used as sensitive indicators for CLP. However, PL distance was not the best markers for trisomy 21, trisomy 18 and CLP.


  • Open Access

    The value of first trimester ultrasound screening for fetal structural abnormalities

    by Xuedong Deng, Lingling Sun, Linliang Yin, Jian Sun, Chunya Ji, Qi Pan, Jun Zhang, Zhong Yang, Chen Ling

    Objective: To explore the value of first trimester ultrasound screening (FTS) for fetal structural abnormalities.Method: This was a single-center retrospective study carried out at the Affiliated Suzhou Hospital of Nanjing Medical University. Total 7523 fetuses were enrolled in the study, including 6376 single pregnancies and 569 twin pregnancies, who underwent FTS during 11~13+6 weeks’ gestation, including nuchal translucency (NT) measurement and anatomy scans with a standard protocol. The fetuses were followed-up with pregnancy outcomes. Results: 147 fetuses (133 single pregnancies and 7 twin pregnancies) were lost to follow-up. A total of 119 fetuses with structural malformations were found by prenatal ultrasound, autopsy after induced abortion, or physical examination after birth, with a deformity incidence rate of 1.61% (119/7376). The highest defects were cardiac abnormalities (35/119, 29.4%), followed by genitourinary system abnormalities (14/119, 11.76%) and skeletal system abnormalities (13/119, 10.2%). Among 119 fetuses, 64 cases (64/119, 53.8%) with structural malformations were detected during the first trimester, while 24.4% (29/119) and 1.68% (2/119) were found during the second and third trimester, respectively. The other 24 cases with fetal structural malformation missed diagnosis prenatally. However, 4 cases with suspected ventricular septal defects (VSD) by FTS were proved to be normal. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) for first trimester ultrasound was 54.2%, 99.9%, 94.1%, and 99.3%, respectively. On the other hand, 48 fetuses (48/452, 10.6%) with thickened NT (above the 95th percentile) showed structural malformations. The prevalence of structural abnormalities was significantly higher in fetuses with increased NT (10.6%) than those with normal NT (71/6924, 1.0%) (PConclusion: FTS was a safe and useful approach for detecting fetal structural malformations early, with high specificity, PPV, and NPV. The increased NT could be a clue for detailed anatomy screening and much attention should be paid. However, it could not replace the second and third trimester ultrasound screening due to the mid-sensitivity.

  • Open Access

    Case Report: Candidate Genes Associated With Prenatal Ultrasound Anomalies in a Fetus With Prenatally Detected 1q23.3q31.2 Deletion

    by Jiahao Song, Qian Zhang, Bing Lu, Zhongshan Gou, Ting Wang, Hui Tang, Jingjing Xiang, Wei Jiang, Xuedong Deng

    Background: Patients with deletions involving the long arm of chromosome 1 are rare, and the main aim of this study was to refine the genotype-phenotype correlation.Case Report: In this report, a 28-year-old pregnant woman, gravida 2 para 1, at 25+4 weeks of gestation underwent ultrasound examination in our institute. The ultrasonographic findings of the fetus were as follows: (1) fetal growth restriction; (2) cleft lip and palate; (3) bilateral renal hypoplasia; (4) lateral ventriculomegaly; (5) single umbilical artery; (6) absent stomach; (7) coronary sinus dilatation with persistent left superior vena cava, ventricular septal defect and unroofed coronary sinus syndrome. Chromosomal microarray analysis of amniotic fluid from the fetus revealed a 28.025 Mb deletion in 1q23.3q31.2, spanning from position 164,559,675 to 192,584,768 (hg19).Conclusion: Genotype-phenotype correlation might improve prenatal diagnosis of fetuses with chromosome 1q deletion. PBX1 could be a candidate gene for fetal growth restriction, renal hypoplasia and congenital heart disease. Fetal growth restriction was accompanied by decreased renal volume in the fetus. Combined with ultrasonic examination, the application of chromosomal microarray analysis will provide accurate prenatal diagnosis.


  • Open Access

    Ultrasonographic study of fetal facial profile markers during the first trimester

    by Chunya Ji, Xiaoli Jiang, Linliang Yin, Xuedong Deng, Zhong Yang, Qi Pan, Jun Zhang, Qing Liang

    Background: To establish reference ranges of fetal facial profile markers and study their correlations with crown-rump length (CRL) during the first trimester (11 ~ 13+ 6weeks’ gestation) in a Chinese population.Methods: Ultrasonographic images of measuring fetal nuchal translucency (NT) were retrospectively selected randomly in normal fetuses whose parents were both Chinese. The facial markers included inferior facial angle (IFA), maxilla-nasion-mandible (MNM) angle, facial maxillary angle (FMA) and profile line (PL) distance. These markers were measured through ViewPoint 6 software by two experienced sonographers.Results: Three hundred and eighty fetuses were selected. The ICCs (95 % CI) of intra-operator 1 reproducibility of IFA, MNM angle, FMA, PL distance were 0.944 (0.886 ~ 0.973), 0.804 (0.629 ~ 0.902), 0.834 (0.68 ~ 0.918) and 0.935 (0.868 ~ 0.969), respectively. The ICCs (95 % CI) of intra-operator 2 reproducibility of IFA, MNM angle, FMA, PL distance were 0.931 (0.857 ~ 0.967), 0.809 (0.637 ~ 0.904), 0.786 (0.600 ~ 0.892) and 0.906 (0.813 ~ 0.954), respectively. The ICCs (95 % CI) of inter-operator reproducibility of IFA, MNM angle, FMA, PL distance were 0.885 (0.663 ~ 0.953), 0.829 (0.672 ~ 0.915), 0.77 (0.511 ~ 0.891) and 0.844 (0.68 ~ 0.925), respectively. The average ± SD of IFA, MNM angle, FMA and PL distance were 80.2°±7.25°, 4.17°±1.19°, 75.36°±5.31°, 2.78 ± 0.54 mm, respectively. IFA and PL distance significantly decreased with CRL, while MNM angle and FMA significantly increased with CRL.Conclusions: It was feasible to measure fetal facial markers during the first trimester. In Chinese population, the reference ranges of IFA, MNM angle, FMA and PL distance were 80.2°±7.25°, 4.17°±1.19°, 75.36°±5.31°, 2.78 ± 0.54 mm, respectively, and the measurements were found to correlate with CRL.