Linliang Yin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Linliang Yin has a total of 101 co-authors. Here are the top co-authors by number of shared publications:
Zhong Yang
The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou, China
10 shared publicationsQi Pan
Center for Medical Ultrasound, Suzhou Municipal Hospital, Gusu School, The Affiliated Suzhou Hospital of Nanjing Medical University, Nanjing Medical University, Suzhou, China
9 shared publications- Xuedong Deng
Center for Medical Ultrasound, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Suzhou, China
9 shared publications Chunya Ji
Center for Medical Ultrasound, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Suzhou, PR China
8 shared publicationsJun Zhang
Center for Medical Ultrasound, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Gusu School, Nanjing Medical University, 215002 Suzhou, Jiangsu, China
7 shared publicationsLingling Sun
Center for Medical Ultrasound, Suzhou Municipal Hospital, Gusu School, The Affiliated Suzhou Hospital of Nanjing Medical University, Nanjing Medical University, Suzhou, China
5 shared publications
Latest Publications
- Open Access
- 16 June 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1)
Artificial intelligence for detecting fetal orofacial clefts and advancing medical education
Orofacial clefts are among the most common congenital craniofacial abnormalities, yet accurate prenatal detection remains challenging due to the scarcity of experienced specialists and the relative rarity of the condition. Early and reliable diagnosis is essential to enable timely clinical intervention and reduce associated morbidity. Here we show that an artificial intelligence system, trained on over 45,139 ultrasound images from 9,215 fetuses across 22 hospitals, can diagnose fetal orofacial clefts with sensitivity and specificity exceeding 93% and 95% respectively, matching the performance of senior radiologists and substantially outperforming junior radiologists. When used as a medical copilot, the system raises junior radiologists’ sensitivity by more than 6 %. Beyond direct diagnostic assistance, the system also accelerates the development of clinical expertise. A pilot study involving 24 radiologists and trainees demonstrated that the model can improve the expertise development for rare conditions. This dual-purpose approach offers a scalable solution for improving both diagnostic accuracy and specialist training in settings where experienced radiologists are scarce.
- 16 June 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1)
Open AccessArtificial intelligence for detecting fetal orofacial clefts and advancing medical education
Orofacial clefts are among the most common congenital craniofacial abnormalities, yet accurate prenatal detection remains challenging due to the scarcity of experienced specialists and the relative rarity of the condition. Early and reliable diagnosis is essential to enable timely clinical intervention and reduce associated morbidity. Here we show that an artificial intelligence system, trained on over 45,139 ultrasound images from 9,215 fetuses across 22 hospitals, can diagnose fetal orofacial clefts with sensitivity and specificity exceeding 93% and 95% respectively, matching the performance of senior radiologists and substantially outperforming junior radiologists. When used as a medical copilot, the system raises junior radiologists’ sensitivity by more than 6 %. Beyond direct diagnostic assistance, the system also accelerates the development of clinical expertise. A pilot study involving 24 radiologists and trainees demonstrated that the model can improve the expertise development for rare conditions. This dual-purpose approach offers a scalable solution for improving both diagnostic accuracy and specialist training in settings where experienced radiologists are scarce.
- Open Access
- 17 March 2026
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 26 (1)
Predictive models for adverse pregnancy outcomes in fetal growth restriction: a systematic review and meta-analysis
We aim to conduct a systematic review and meta-analysis to evaluate the performance of existing predictive models for adverse pregnancy outcomes in pregnan
- 17 March 2026
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 26 (1)
Open AccessPredictive models for adverse pregnancy outcomes in fetal growth restriction: a systematic review and meta-analysis
We aim to conduct a systematic review and meta-analysis to evaluate the performance of existing predictive models for adverse pregnancy outcomes in pregnan
- 1 July 2025
- Published by Radiological Society of North America (RSNA) in Radiology: Artificial Intelligence
- Vol. 7 (4) , e240498
Deep Learning Model for Real-Time Nuchal Translucency Assessment at Prenatal US
The Automated Identification and Measurement of Nuchal Translucency model for nuchal translucency assessment demonstrated high diagnostic accuracy and closely matched radiologist workflow patterns in real-time US diagnostics.
- 1 July 2025
- Published by Radiological Society of North America (RSNA) in Radiology: Artificial Intelligence
- Vol. 7 (4) , e240498
Deep Learning Model for Real-Time Nuchal Translucency Assessment at Prenatal US
The Automated Identification and Measurement of Nuchal Translucency model for nuchal translucency assessment demonstrated high diagnostic accuracy and closely matched radiologist workflow patterns in real-time US diagnostics.
- Open Access
- 1 March 2024
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 63 (3) , 321-330
Construction of prediction model for fetal growth restriction during first trimester in an Asian population
Objective: To construct a prediction model for fetal growth restriction (FGR) during the first trimester of pregnancy and evaluate its screening performance.Methods: This was a prospective cohort study of singleton pregnancies that underwent routine ultrasound screening at 11 to 13 + 6 weeks at the Affiliated Suzhou Hospital of Nanjing Medical University between January 2019 and April 2022. Basic clinical information, ultrasound indicators and serum biomarkers of pregnant women were collected. Fetal weight assessment was based on the fetal growth curve for the Southern Chinese population. FGR was diagnosed according to Delphi consensus criteria. Least absolute shrinkage and selection operator (lasso) regression was used to select variables for inclusion in the model. Discrimination, calibration and clinical effectiveness of the model were evaluated in training and validation cohorts.Results: A total of 1188 pregnant women were included, of whom 108 had FGR. Lasso regression identified seven predictive features, including history of maternal hypertension, maternal smoking or passive smoking, gravidity, uterine artery pulsatility index, ductus venosus pulsatility index and multiples of the median values of placental growth factor and soluble fms‐like tyrosine kinase‐1. The nomogram prediction model constructed from these seven variables accurately predicted FGR, and the area under the receiver‐operating‐characteristics curve in the validation cohort was 0.82 (95% CI, 0.74–0.90). The calibration curve and Hosmer–Lemeshow test demonstrated good calibration, and the clinical decision curve and clinical impact curve supported its practical value in a clinical setting.Conclusion: The multi‐index prediction model for FGR has good predictive value during the first trimester. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
- 1 March 2024
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 63 (3) , 321-330
Open AccessConstruction of prediction model for fetal growth restriction during first trimester in an Asian population
Objective: To construct a prediction model for fetal growth restriction (FGR) during the first trimester of pregnancy and evaluate its screening performance.Methods: This was a prospective cohort study of singleton pregnancies that underwent routine ultrasound screening at 11 to 13 + 6 weeks at the Affiliated Suzhou Hospital of Nanjing Medical University between January 2019 and April 2022. Basic clinical information, ultrasound indicators and serum biomarkers of pregnant women were collected. Fetal weight assessment was based on the fetal growth curve for the Southern Chinese population. FGR was diagnosed according to Delphi consensus criteria. Least absolute shrinkage and selection operator (lasso) regression was used to select variables for inclusion in the model. Discrimination, calibration and clinical effectiveness of the model were evaluated in training and validation cohorts.Results: A total of 1188 pregnant women were included, of whom 108 had FGR. Lasso regression identified seven predictive features, including history of maternal hypertension, maternal smoking or passive smoking, gravidity, uterine artery pulsatility index, ductus venosus pulsatility index and multiples of the median values of placental growth factor and soluble fms‐like tyrosine kinase‐1. The nomogram prediction model constructed from these seven variables accurately predicted FGR, and the area under the receiver‐operating‐characteristics curve in the validation cohort was 0.82 (95% CI, 0.74–0.90). The calibration curve and Hosmer–Lemeshow test demonstrated good calibration, and the clinical decision curve and clinical impact curve supported its practical value in a clinical setting.Conclusion: The multi‐index prediction model for FGR has good predictive value during the first trimester. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
- Open Access
- 1 February 2024
- Published by Taylor & Francis in International Journal of Nanomedicine
- Vol. ume 19, 1909-1922
Development of Small HN Linked Radionuclide Iodine-125 for Nanocarrier Image Tracing in Mouse Model
Background: Radionuclides have important roles in clinical tumor radiotherapy as they are used to kill tumor cells or as imaging agents for drug tracing. The application of radionuclides has been developing as an increasing number of nanomaterials are used to deliver radionuclides to tumor areas to kill tumor cells. However, promoting the efficient combination of radionuclides and nanocarriers (NCs), enhancing radionuclide loading efficiency, and avoiding environmental pollution caused by radionuclide overuse are important challenges that hinder their further development. Methods: In the present study, a new small molecule compound (3-[[(2S)-2-hydroxy-3-(4-hydroxyphenyl)-1-carbonyl] amino]-alanine, abbreviation: HN, molecular formula: C12H16N2O5) was synthesized as a linker between radionuclide iodine-125 (125I) and NCs to enable a more efficient binding between NCs and radionuclides. Results: In vitro evidence indicated that the linker was able to bind 125I with higher efficiency (labeling efficiency > 80%) than that of tyrosine, as well as various NCs, such as cellulose nanofibers, metal oxide NCs, and graphene oxide. Single-photon emission computed tomography/computed tomography imaging demonstrated the biological distribution of 125I-labeled NCs in different organs/tissues after administration in mice. Conclusion: These results showed an improvement in radionuclide labeling efficiency for nanocarriers and provided an approach for nanocarrier image tracing.
- 1 February 2024
- Published by Taylor & Francis in International Journal of Nanomedicine
- Vol. ume 19, 1909-1922
Open AccessDevelopment of Small HN Linked Radionuclide Iodine-125 for Nanocarrier Image Tracing in Mouse Model
Background: Radionuclides have important roles in clinical tumor radiotherapy as they are used to kill tumor cells or as imaging agents for drug tracing. The application of radionuclides has been developing as an increasing number of nanomaterials are used to deliver radionuclides to tumor areas to kill tumor cells. However, promoting the efficient combination of radionuclides and nanocarriers (NCs), enhancing radionuclide loading efficiency, and avoiding environmental pollution caused by radionuclide overuse are important challenges that hinder their further development. Methods: In the present study, a new small molecule compound (3-[[(2S)-2-hydroxy-3-(4-hydroxyphenyl)-1-carbonyl] amino]-alanine, abbreviation: HN, molecular formula: C12H16N2O5) was synthesized as a linker between radionuclide iodine-125 (125I) and NCs to enable a more efficient binding between NCs and radionuclides. Results: In vitro evidence indicated that the linker was able to bind 125I with higher efficiency (labeling efficiency > 80%) than that of tyrosine, as well as various NCs, such as cellulose nanofibers, metal oxide NCs, and graphene oxide. Single-photon emission computed tomography/computed tomography imaging demonstrated the biological distribution of 125I-labeled NCs in different organs/tissues after administration in mice. Conclusion: These results showed an improvement in radionuclide labeling efficiency for nanocarriers and provided an approach for nanocarrier image tracing.
- Open Access
- 10 October 2023
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 23 (1) , 1-12
A novel artificial intelligence model for fetal facial profile marker measurement during the first trimester
Background: To study the validity of an artificial intelligence (AI) model for measuring fetal facial profile markers, and to evaluate the clinical value of the AI model for identifying fetal abnormalities during the first trimester. Methods: This retrospective study used two-dimensional mid-sagittal fetal profile images taken during singleton pregnancies at 11–13+ 6 weeks of gestation. We measured the facial profile markers, including inferior facial angle (IFA), maxilla-nasion-mandible (MNM) angle, facial-maxillary angle (FMA), frontal space (FS) distance, and profile line (PL) distance using AI and manual measurements. Semantic segmentation and landmark localization were used to develop an AI model to measure the selected markers and evaluate the diagnostic value for fetal abnormalities. The consistency between AI and manual measurements was compared using intraclass correlation coefficients (ICC). The diagnostic value of facial markers measured using the AI model during fetal abnormality screening was evaluated using receiver operating characteristic (ROC) curves. Results: A total of 2372 normal fetuses and 37 with abnormalities were observed, including 18 with trisomy 21, 7 with trisomy 18, and 12 with CLP. Among them, 1872 normal fetuses were used for AI model training and validation, and the remaining 500 normal fetuses and all fetuses with abnormalities were used for clinical testing. The ICCs (95%CI) of the IFA, MNM angle, FMA, FS distance, and PL distance between the AI and manual measurement for the 500 normal fetuses were 0.812 (0.780–0.840), 0.760 (0.720–0.795), 0.766 (0.727-0.800), 0.807 (0.775–0.836), and 0.798 (0.764–0.828), respectively. IFA clinically significantly identified trisomy 21 and trisomy 18, with areas under the ROC curve (AUC) of 0.686 (95%CI, 0.585–0.788) and 0.729 (95%CI, 0.621–0.837), respectively. FMA effectively predicted trisomy 18, with an AUC of 0.904 (95%CI, 0.842–0.966). MNM angle and FS distance exhibited good predictive value in CLP, with AUCs of 0.738 (95%CI, 0.573–0.902) and 0.677 (95%CI, 0.494–0.859), respectively. Conclusions: The consistency of fetal facial profile marker measurements between the AI and manual measurement was good during the first trimester. The AI model is a convenient and effective tool for the early screen for fetal trisomy 21, trisomy 18, and CLP, which can be generalized to first-trimester scanning (FTS).
- 10 October 2023
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 23 (1) , 1-12
Open AccessA novel artificial intelligence model for fetal facial profile marker measurement during the first trimester
Background: To study the validity of an artificial intelligence (AI) model for measuring fetal facial profile markers, and to evaluate the clinical value of the AI model for identifying fetal abnormalities during the first trimester. Methods: This retrospective study used two-dimensional mid-sagittal fetal profile images taken during singleton pregnancies at 11–13+ 6 weeks of gestation. We measured the facial profile markers, including inferior facial angle (IFA), maxilla-nasion-mandible (MNM) angle, facial-maxillary angle (FMA), frontal space (FS) distance, and profile line (PL) distance using AI and manual measurements. Semantic segmentation and landmark localization were used to develop an AI model to measure the selected markers and evaluate the diagnostic value for fetal abnormalities. The consistency between AI and manual measurements was compared using intraclass correlation coefficients (ICC). The diagnostic value of facial markers measured using the AI model during fetal abnormality screening was evaluated using receiver operating characteristic (ROC) curves. Results: A total of 2372 normal fetuses and 37 with abnormalities were observed, including 18 with trisomy 21, 7 with trisomy 18, and 12 with CLP. Among them, 1872 normal fetuses were used for AI model training and validation, and the remaining 500 normal fetuses and all fetuses with abnormalities were used for clinical testing. The ICCs (95%CI) of the IFA, MNM angle, FMA, FS distance, and PL distance between the AI and manual measurement for the 500 normal fetuses were 0.812 (0.780–0.840), 0.760 (0.720–0.795), 0.766 (0.727-0.800), 0.807 (0.775–0.836), and 0.798 (0.764–0.828), respectively. IFA clinically significantly identified trisomy 21 and trisomy 18, with areas under the ROC curve (AUC) of 0.686 (95%CI, 0.585–0.788) and 0.729 (95%CI, 0.621–0.837), respectively. FMA effectively predicted trisomy 18, with an AUC of 0.904 (95%CI, 0.842–0.966). MNM angle and FS distance exhibited good predictive value in CLP, with AUCs of 0.738 (95%CI, 0.573–0.902) and 0.677 (95%CI, 0.494–0.859), respectively. Conclusions: The consistency of fetal facial profile marker measurements between the AI and manual measurement was good during the first trimester. The AI model is a convenient and effective tool for the early screen for fetal trisomy 21, trisomy 18, and CLP, which can be generalized to first-trimester scanning (FTS).
- Open Access
- 17 August 2023
- Published by IMR Press in Clinical and Experimental Obstetrics & Gynecology
- Vol. 50 (8) , 174
Standardized First-Trimester Ultrasound Screening for Fetal Structural Abnormalities in A Non-Selective Population: A Single-Center Experience
Background: To explore the effectiveness of standardized first-trimester ultrasound screening (FTS) in detecting fetal structural abnormalities in a non-selective population. Methods: A retrospective study was performed on 7523 fetuses (6376 single and 569 twin pregnancies) who underwent FTS between 11 and 13+6 weeks’ gestation. All fetuses received anatomy scans using a standardized protocol. Results: 147 fetuses (133 single and 7 twin pregnancies) were lost to follow up. Of the remaining 7376 fetuses, 119 (1.61%, 119/7376) developed structural malformations, with 64 cases (53.8%, 64/119) identified during the first trimester. The remaining cases were detected during the second trimester (24.4%, 29/119), the third trimester (1.68%, 2/119), and postnatally (20.2%, 24/119). There were 4 cases of suspected ventricular septal defect (VSD) by FTS, which were later confirmed to be normal. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for FTS were 54.2%, 99.9%, 94.1%, and 99.3%, respectively. Forty eight fetuses, accounting for 10.6% of the total (452), with thickened nuchal translucency (NT) (above the 95th percentile) showed structural malformations. This was significantly higher than the prevalence of structural abnormalities found in fetuses with normal NT (1.0%, 71/6924) (p < 0.01). Conclusions: Standardized FTS is highly effective in detecting fetal structural malformations early, with impressive specificity, PPV, and NPV. Increased NT suggests detailed anatomy screening and helps guide treatment. However, while standardized FTS is an invaluable tool, it cannot fully replace the sensitivity of second- and third-trimester ultrasound screening. Clinical Trial Registration: The study was registered at https://www.chictr.org.cn (registration number ChiCTR-SOC-17010976).
- 17 August 2023
- Published by IMR Press in Clinical and Experimental Obstetrics & Gynecology
- Vol. 50 (8) , 174
Open AccessStandardized First-Trimester Ultrasound Screening for Fetal Structural Abnormalities in A Non-Selective Population: A Single-Center Experience
Background: To explore the effectiveness of standardized first-trimester ultrasound screening (FTS) in detecting fetal structural abnormalities in a non-selective population. Methods: A retrospective study was performed on 7523 fetuses (6376 single and 569 twin pregnancies) who underwent FTS between 11 and 13+6 weeks’ gestation. All fetuses received anatomy scans using a standardized protocol. Results: 147 fetuses (133 single and 7 twin pregnancies) were lost to follow up. Of the remaining 7376 fetuses, 119 (1.61%, 119/7376) developed structural malformations, with 64 cases (53.8%, 64/119) identified during the first trimester. The remaining cases were detected during the second trimester (24.4%, 29/119), the third trimester (1.68%, 2/119), and postnatally (20.2%, 24/119). There were 4 cases of suspected ventricular septal defect (VSD) by FTS, which were later confirmed to be normal. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for FTS were 54.2%, 99.9%, 94.1%, and 99.3%, respectively. Forty eight fetuses, accounting for 10.6% of the total (452), with thickened nuchal translucency (NT) (above the 95th percentile) showed structural malformations. This was significantly higher than the prevalence of structural abnormalities found in fetuses with normal NT (1.0%, 71/6924) (p < 0.01). Conclusions: Standardized FTS is highly effective in detecting fetal structural malformations early, with impressive specificity, PPV, and NPV. Increased NT suggests detailed anatomy screening and helps guide treatment. However, while standardized FTS is an invaluable tool, it cannot fully replace the sensitivity of second- and third-trimester ultrasound screening. Clinical Trial Registration: The study was registered at https://www.chictr.org.cn (registration number ChiCTR-SOC-17010976).
- Open Access
- 10 August 2023
- Published by Springer Nature in Research Square
A novel artificial intelligence model for fetal facial profile marker measurement during the first trimester
Background: To study the validity of an artificial intelligence (AI) model for measuring fetal facial profile markers, and to evaluate the diagnostic value of the AI model for identifying fetal abnormalities during the first trimester. Methods: This retrospective study used two-dimensional mid-sagittal fetal profile images taken during singleton pregnancies at 11–13+6 weeks of gestation. We measured the facial profile markers, including inferior facial angle (IFA), maxilla-nasion-mandible (MNM) angle, facial-maxillary angle (FMA), frontal space (FS) distance, and profile line (PL) distance using AI and manual measurements. Semantic segmentation and landmark localization were used to develop an AI model to measure the selected markers and evaluate the diagnostic value for fetal abnormalities. The consistency between AI and manual measurements was compared using intraclass correlation coefficients (ICC). The diagnostic value of facial markers measured using the AI model during fetal abnormality screening was evaluated using receiver operating characteristic (ROC) curves. Results: A total of 2372 normal fetuses and 37 with abnormalities were observed, including 18 with trisomy 21, 7 with trisomy 18, and 12 with CLP. Among them, 1872 normal fetuses were used for AI model training and validation, and the remaining 500 normal fetuses and all fetuses with abnormalities were used for clinical testing. The ICCs (95%CI) of the IFA, MNM angle, FMA, FS distance, and PL distance between the AI and manual measurement for the 500 normal fetuses were 0.812 (0.780-0.840), 0.760 (0.720-0.795), 0.766 (0.727-0.800), 0.807 (0.775-0.836), and 0.798 (0.764-0.828), respectively. IFA clinically significantly identified trisomy 21 and trisomy 18, with areas under the ROC curve (AUC) of 0.686 (95%CI, 0.585-0.788) and 0.729 (95%CI, 0.621-0.837), respectively. FMA effectively predicted trisomy 18, with an AUC of 0.904 (95%CI, 0.842-0.966). MNM angle and FS distance exhibited good predictive value in CLP, with AUCs of 0.738 (95%CI, 0.573-0.902) and 0.677 (95%CI, 0.494-0.859), respectively. Conclusions: The consistency of fetal facial profile marker measurements between the AI and manual measurement was good during the first trimester. The AI model is a convenient and effective tool for the early diagnosis of fetal trisomy 21, trisomy 18, and CLP, which can be generalized to first-trimester scanning (FTS).
- 10 August 2023
- Published by Springer Nature in Research Square
Open AccessA novel artificial intelligence model for fetal facial profile marker measurement during the first trimester
Background: To study the validity of an artificial intelligence (AI) model for measuring fetal facial profile markers, and to evaluate the diagnostic value of the AI model for identifying fetal abnormalities during the first trimester. Methods: This retrospective study used two-dimensional mid-sagittal fetal profile images taken during singleton pregnancies at 11–13+6 weeks of gestation. We measured the facial profile markers, including inferior facial angle (IFA), maxilla-nasion-mandible (MNM) angle, facial-maxillary angle (FMA), frontal space (FS) distance, and profile line (PL) distance using AI and manual measurements. Semantic segmentation and landmark localization were used to develop an AI model to measure the selected markers and evaluate the diagnostic value for fetal abnormalities. The consistency between AI and manual measurements was compared using intraclass correlation coefficients (ICC). The diagnostic value of facial markers measured using the AI model during fetal abnormality screening was evaluated using receiver operating characteristic (ROC) curves. Results: A total of 2372 normal fetuses and 37 with abnormalities were observed, including 18 with trisomy 21, 7 with trisomy 18, and 12 with CLP. Among them, 1872 normal fetuses were used for AI model training and validation, and the remaining 500 normal fetuses and all fetuses with abnormalities were used for clinical testing. The ICCs (95%CI) of the IFA, MNM angle, FMA, FS distance, and PL distance between the AI and manual measurement for the 500 normal fetuses were 0.812 (0.780-0.840), 0.760 (0.720-0.795), 0.766 (0.727-0.800), 0.807 (0.775-0.836), and 0.798 (0.764-0.828), respectively. IFA clinically significantly identified trisomy 21 and trisomy 18, with areas under the ROC curve (AUC) of 0.686 (95%CI, 0.585-0.788) and 0.729 (95%CI, 0.621-0.837), respectively. FMA effectively predicted trisomy 18, with an AUC of 0.904 (95%CI, 0.842-0.966). MNM angle and FS distance exhibited good predictive value in CLP, with AUCs of 0.738 (95%CI, 0.573-0.902) and 0.677 (95%CI, 0.494-0.859), respectively. Conclusions: The consistency of fetal facial profile marker measurements between the AI and manual measurement was good during the first trimester. The AI model is a convenient and effective tool for the early diagnosis of fetal trisomy 21, trisomy 18, and CLP, which can be generalized to first-trimester scanning (FTS).
- Open Access
- 14 March 2023
- Published by Springer Nature in Research Square
First trimester fetal ultrasonographic soft markers and adverse pregnancy outcomes
Objective To evaluate the relationship between first trimester (11 ~ 13+ 6 gestational weeks) ultrasonographic soft markers (USMs) and fetal adverse pregnancy outcomes. Methods A retrospective study, singleton pregnancies were recruited from the first-trimester scanning (FTS) during May 2017 to August 2021 at the Affiliated Suzhou Hospital of Nanjing Medical University. All fetuses were followed up till birth or induced abortion. The spectrum and detection rate of USMs during the first trimester were studied. The correlation between USMs and adverse pregnancy outcomes was analyzed to evaluate the management of fetus with 1st trimester USMs. Results Among 7355 fetuses who underwent FTS, 6868 fetuses with complete follow-up outcomes were recruited in the study. Total 1105 USMs were reported among 963 fetuses during the first trimester. According to the detection rate, the most frequently detected USMs were increased nuchal translucency (NT) thickeness (6.70%, 460/6868), followed by echogenic intracardiac focus (EIF) (5.10%, 350/6868), absent/reversed a-wave of ductus venosus (1.35%, 93/6868) and absence/hypoplasia of the nasal bone (NB) (1.03%, 71/6868). The incidence of adverse pregnancy outcomes in fetuses with two or more USMs was 36.44% (43/118), which was significantly higher (χ2 = 114.50, P < 0.001) than fetuses with single USM (5.68%, 48/845). The incidence of adverse pregnancy outcomes in fetuses who had both USMs and structural abnormalities was 72.60% (53/73), were also significantly higher (χ2 = 368.17, P < 0.001) than fetuses with isolated USMs without structural abnormalities (4.27%, 38/890). Logistic regression analysis showed increased NT thickness, absence/hypoplasia of the NB, absent/reversed a-wave of ductus venosus, tricuspid regurgitation (TR), choroid plexus cyst (CPC), echogenic bowel (EB) and single umbilical artery (SUA) were closely associated with the adverse pregnancy outcomes (P < 0.05). However, there was no significant correlation between EIF, mild pyelectasis (PYE) and fetal adverse pregnancy outcomes (P = 0.30; P = 0.77). Conclusions The ultrasonographic soft markers found during the first trimester, especially multiple USMs, or USMs are associated with structural malformations, are potential soft markers in predicting fetal adverse pregnancy outcomes.
- 14 March 2023
- Published by Springer Nature in Research Square
Open AccessFirst trimester fetal ultrasonographic soft markers and adverse pregnancy outcomes
Objective To evaluate the relationship between first trimester (11 ~ 13+ 6 gestational weeks) ultrasonographic soft markers (USMs) and fetal adverse pregnancy outcomes. Methods A retrospective study, singleton pregnancies were recruited from the first-trimester scanning (FTS) during May 2017 to August 2021 at the Affiliated Suzhou Hospital of Nanjing Medical University. All fetuses were followed up till birth or induced abortion. The spectrum and detection rate of USMs during the first trimester were studied. The correlation between USMs and adverse pregnancy outcomes was analyzed to evaluate the management of fetus with 1st trimester USMs. Results Among 7355 fetuses who underwent FTS, 6868 fetuses with complete follow-up outcomes were recruited in the study. Total 1105 USMs were reported among 963 fetuses during the first trimester. According to the detection rate, the most frequently detected USMs were increased nuchal translucency (NT) thickeness (6.70%, 460/6868), followed by echogenic intracardiac focus (EIF) (5.10%, 350/6868), absent/reversed a-wave of ductus venosus (1.35%, 93/6868) and absence/hypoplasia of the nasal bone (NB) (1.03%, 71/6868). The incidence of adverse pregnancy outcomes in fetuses with two or more USMs was 36.44% (43/118), which was significantly higher (χ2 = 114.50, P < 0.001) than fetuses with single USM (5.68%, 48/845). The incidence of adverse pregnancy outcomes in fetuses who had both USMs and structural abnormalities was 72.60% (53/73), were also significantly higher (χ2 = 368.17, P < 0.001) than fetuses with isolated USMs without structural abnormalities (4.27%, 38/890). Logistic regression analysis showed increased NT thickness, absence/hypoplasia of the NB, absent/reversed a-wave of ductus venosus, tricuspid regurgitation (TR), choroid plexus cyst (CPC), echogenic bowel (EB) and single umbilical artery (SUA) were closely associated with the adverse pregnancy outcomes (P < 0.05). However, there was no significant correlation between EIF, mild pyelectasis (PYE) and fetal adverse pregnancy outcomes (P = 0.30; P = 0.77). Conclusions The ultrasonographic soft markers found during the first trimester, especially multiple USMs, or USMs are associated with structural malformations, are potential soft markers in predicting fetal adverse pregnancy outcomes.
- Open Access
- 22 February 2023
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 23 (1) , 1-7
A case of Aicardi-Goutières syndrome caused by TREX1 gene mutation
Aicardi-Goutières syndrome (AGS) is a rare genetic disorder involving the central nervous system and autoimmune abnormalities, leading to severe intellectual and physical disability with poor prognosis. AGS has a phenotype similar to intrauterine viral infection, which often leads to delays in genetic counseling. In this study, we report a case with a prenatal diagnosis of AGS. The first fetal ultrasound detected bilateral lateral ventricle cystic structures, and fetal MRI was performed to identify other signs. The right parietal lobe signal showed cerebral white matter abnormalities, and fetal brain development level was lower than that of normal fetuses of the same gestational age. Whole-exome sequencing revealed that the fetus carried the TREX1:NM_033629.6:exon2:c.294dup:p. C99Mfs*3 variant, suggesting that the c.294dup mutation of the TREX1 gene was the pathogenic mutation site, and the final comprehensive diagnosis was AGS1. In this article, we also reviewed the previous literature for possible phenotypes in the fetus and found that microcephaly and intrauterine growth retardation may be the first and most important markers of the intrauterine phenotype of AGS.
- 22 February 2023
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 23 (1) , 1-7
Open AccessA case of Aicardi-Goutières syndrome caused by TREX1 gene mutation
Aicardi-Goutières syndrome (AGS) is a rare genetic disorder involving the central nervous system and autoimmune abnormalities, leading to severe intellectual and physical disability with poor prognosis. AGS has a phenotype similar to intrauterine viral infection, which often leads to delays in genetic counseling. In this study, we report a case with a prenatal diagnosis of AGS. The first fetal ultrasound detected bilateral lateral ventricle cystic structures, and fetal MRI was performed to identify other signs. The right parietal lobe signal showed cerebral white matter abnormalities, and fetal brain development level was lower than that of normal fetuses of the same gestational age. Whole-exome sequencing revealed that the fetus carried the TREX1:NM_033629.6:exon2:c.294dup:p. C99Mfs*3 variant, suggesting that the c.294dup mutation of the TREX1 gene was the pathogenic mutation site, and the final comprehensive diagnosis was AGS1. In this article, we also reviewed the previous literature for possible phenotypes in the fetus and found that microcephaly and intrauterine growth retardation may be the first and most important markers of the intrauterine phenotype of AGS.