Steven D. Phillips
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Steven D. Phillips has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Bala Muralikrishnan
National Institute of Standards and Technology, Physical Measurement Laboratory, Sensor Science Division, Gaithersburg, MD 20899, USA
4 shared publications - Chris Blackburn
Precision Engineering Division, National Institute of Standards and Technology, Gaithersburg, MD 20899
4 shared publications - Daniel Sawyer
National Institute of Standards and Technology, Physical Measurement Laboratory, Sensor Science Division, Gaithersburg, MD 20899, USA
4 shared publications - W. Tyler Estler
Precision Engineering Division, National Institute of Standards and Technology, Gaithersburg, MD 20899
3 shared publications - Alessandro Balsamo
INRIM Natl Inst Res Metrol, Turin, Italy
1 shared publication - Blaza Toman
Information Technology Laboratory National Institute of Standards and Technology Boulder CO 80305 USA
1 shared publication
Latest Publications
- 1 October 2016
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 121, 498-504
The 2016 Revision of ISO 1 – Standard Reference Temperature for the Specification of Geometrical and Dimensional Properties
This paper discusses the changes in the 2016 (third edition) of International Standard ISO 1. While the value of the standard reference temperature remains unchanged at 20 °C, the important definitions for the “reference temperature” and “standard reference temperature,” absent in prior editions, are now defined, with the latter exclusively reserved for the assignment of the internationally agreed upon temperature of 20 °C. The scope of the revised Standard has been carefully refined and made more explicit. This, together with other clarifications and improvements, has eliminated the ambiguities associated with specifications at non-standard reference temperatures and allows, if needed, different reference temperatures to be associated with different properties of a workpiece. The relationship between ISO 1 and dimensional measurements is also discussed and clarified. In this paper, we discuss the motivation for these changes and present several issues debated during the revision process for the benefit of future standards committees that might study this topic
- 1 October 2016
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 121, 498-504
The 2016 Revision of ISO 1 – Standard Reference Temperature for the Specification of Geometrical and Dimensional Properties
This paper discusses the changes in the 2016 (third edition) of International Standard ISO 1. While the value of the standard reference temperature remains unchanged at 20 °C, the important definitions for the “reference temperature” and “standard reference temperature,” absent in prior editions, are now defined, with the latter exclusively reserved for the assignment of the internationally agreed upon temperature of 20 °C. The scope of the revised Standard has been carefully refined and made more explicit. This, together with other clarifications and improvements, has eliminated the ambiguities associated with specifications at non-standard reference temperatures and allows, if needed, different reference temperatures to be associated with different properties of a workpiece. The relationship between ISO 1 and dimensional measurements is also discussed and clarified. In this paper, we discuss the motivation for these changes and present several issues debated during the revision process for the benefit of future standards committees that might study this topic
- 1 December 2014
- Published by NCSL International in NCSLI Measure
- Vol. 9 (4) , 40-45
In-situ Temperature Calibration Capability for Dimensional Metrology
The Dimensional Metrology Group (DMG) at the National Institute of Standards and Technology (NIST) has developed a new in-situ temperature calibration system. This paper discusses the system components, an in-situ calibration procedure, and the uncertainty sources involved in the calibration process. It also presents an uncertainty budget, and examines it with a Monte Carlo simulation. This system enables the DMG to perform quicker in-situ temperature calibration, at frequent intervals with minimal downtime, and provides lower uncertainties for the dimensional measurements.
- 1 December 2014
- Published by NCSL International in NCSLI Measure
- Vol. 9 (4) , 40-45
In-situ Temperature Calibration Capability for Dimensional Metrology
The Dimensional Metrology Group (DMG) at the National Institute of Standards and Technology (NIST) has developed a new in-situ temperature calibration system. This paper discusses the system components, an in-situ calibration procedure, and the uncertainty sources involved in the calibration process. It also presents an uncertainty budget, and examines it with a Monte Carlo simulation. This system enables the DMG to perform quicker in-situ temperature calibration, at frequent intervals with minimal downtime, and provides lower uncertainties for the dimensional measurements.
- 28 April 2014
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 81 (5) , 237-245
Assessment of conformity, decision rules and risk analysis
Measurement uncertainty has important economic consequences for calibration and inspection activities. In calibration reports, the magnitude of the uncertainty is often taken as an indication of the quality of the laboratory. In industrial measurements, uncertainty has an economic impact through the decision rule employed in accepting and rejecting products. With significant economic interests at stake, manufacturers and consumers have to guard against accepting bad products and rejecting good ones. While the evaluation of measurement uncertainty is a pure technical activity well described in the GUM, the selection of a decision rule is a business decision that involves cost considerations. Recently, several national and international standards bodies have addressed the decision rule issue to provide a uniform, unambiguous terminology for documenting a decision rule and to describe the relationship between conforming characteristics and acceptable measurement results. Similarly, the issue of risk analysis addresses the problem of determining the gauging limits that define the boundaries of acceptable measurement results. Gauging limits are chosen to balance the risks of the two types of decision errors (accepting nonconforming products and rejecting conforming products), whose relative magnitudes depend upon product-specific economic factors. This paper reviews recent standardization developments in these areas.
- 28 April 2014
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 81 (5) , 237-245
Assessment of conformity, decision rules and risk analysis
Measurement uncertainty has important economic consequences for calibration and inspection activities. In calibration reports, the magnitude of the uncertainty is often taken as an indication of the quality of the laboratory. In industrial measurements, uncertainty has an economic impact through the decision rule employed in accepting and rejecting products. With significant economic interests at stake, manufacturers and consumers have to guard against accepting bad products and rejecting good ones. While the evaluation of measurement uncertainty is a pure technical activity well described in the GUM, the selection of a decision rule is a business decision that involves cost considerations. Recently, several national and international standards bodies have addressed the decision rule issue to provide a uniform, unambiguous terminology for documenting a decision rule and to describe the relationship between conforming characteristics and acceptable measurement results. Similarly, the issue of risk analysis addresses the problem of determining the gauging limits that define the boundaries of acceptable measurement results. Gauging limits are chosen to balance the risks of the two types of decision errors (accepting nonconforming products and rejecting conforming products), whose relative magnitudes depend upon product-specific economic factors. This paper reviews recent standardization developments in these areas.
- 1 January 2012
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 117, 216-30
A Model for Geometry-Dependent Errors in Length Artifacts
We present a detailed model of dimensional changes in long length artifacts, such as step gauges and ball bars, due to bending under gravity. The comprehensive model is based on evaluation of the gauge points relative to the neutral bending surface. It yields the errors observed when the gauge points are located off the neutral bending surface of a bar or rod but also reveals the significant error associated with out-of-straightness of a bar or rod even if the gauge points are located in the neutral bending surface. For example, one experimental result shows a length change of greater than 1.5 µm on a 1 m ball bar with an out-of-straightness of 0.4 mm. This and other results are in agreement with the model presented in this paper.
- 1 January 2012
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 117, 216-30
A Model for Geometry-Dependent Errors in Length Artifacts
We present a detailed model of dimensional changes in long length artifacts, such as step gauges and ball bars, due to bending under gravity. The comprehensive model is based on evaluation of the gauge points relative to the neutral bending surface. It yields the errors observed when the gauge points are located off the neutral bending surface of a bar or rod but also reveals the significant error associated with out-of-straightness of a bar or rod even if the gauge points are located in the neutral bending surface. For example, one experimental result shows a length change of greater than 1.5 µm on a 1 m ball bar with an out-of-straightness of 0.4 mm. This and other results are in agreement with the model presented in this paper.
- 1 September 2010
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 115 (5) , 291-301
Measuring scale errors in a laser tracker's horizontal angle encoder through simple length measurement and two-face system tests
We describe a method to estimate the scale errors in the horizontal angle encoder of a laser tracker in this paper. The method does not require expensive instrumentation such as a rotary stage or even a calibrated artifact. An uncalibrated but stable length is realized between two targets mounted on stands that are at tracker height. The tracker measures the distance between these two targets from different azimuthal positions (say, in intervals of 20° over 360°). Each target is measured in both front face and back face. Low order harmonic scale errors can be estimated from this data and may then be used to correct the encoder’s error map to improve the tracker’s angle measurement accuracy. We have demonstrated this for the second order harmonic in this paper. It is important to compensate for even order harmonics as their influence cannot be removed by averaging front face and back face measurements whereas odd orders can be removed by averaging. We tested six trackers from three different manufacturers. Two of those trackers are newer models introduced at the time of writing of this paper. For older trackers from two manufacturers, the length errors in a 7.75 m horizontal length placed 7 m away from a tracker were of the order of ± 65 μm before correcting the error map. They reduced to less than ± 25 μm after correcting the error map for second order scale errors. Newer trackers from the same manufacturers did not show this error. An older tracker from a third manufacturer also did not show this error.
- 1 September 2010
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 115 (5) , 291-301
Measuring scale errors in a laser tracker's horizontal angle encoder through simple length measurement and two-face system tests
We describe a method to estimate the scale errors in the horizontal angle encoder of a laser tracker in this paper. The method does not require expensive instrumentation such as a rotary stage or even a calibrated artifact. An uncalibrated but stable length is realized between two targets mounted on stands that are at tracker height. The tracker measures the distance between these two targets from different azimuthal positions (say, in intervals of 20° over 360°). Each target is measured in both front face and back face. Low order harmonic scale errors can be estimated from this data and may then be used to correct the encoder’s error map to improve the tracker’s angle measurement accuracy. We have demonstrated this for the second order harmonic in this paper. It is important to compensate for even order harmonics as their influence cannot be removed by averaging front face and back face measurements whereas odd orders can be removed by averaging. We tested six trackers from three different manufacturers. Two of those trackers are newer models introduced at the time of writing of this paper. For older trackers from two manufacturers, the length errors in a 7.75 m horizontal length placed 7 m away from a tracker were of the order of ± 65 μm before correcting the error map. They reduced to less than ± 25 μm after correcting the error map for second order scale errors. Newer trackers from the same manufacturers did not show this error. An older tracker from a third manufacturer also did not show this error.
- 1 January 2009
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 114 (1) , 21-35
ASME B89.4.19 Performance Evaluation Tests and Geometric Misalignments in Laser Trackers
Small and unintended offsets, tilts, and eccentricity of the mechanical and optical components in laser trackers introduce systematic errors in the measured spherical coordinates (angles and range readings) and possibly in the calculated lengths of reference artifacts. It is desirable that the tests described in the ASME B89.4.19 Standard [1] be sensitive to these geometric misalignments so that any resulting systematic errors are identified during performance evaluation. In this paper, we present some analysis, using error models and numerical simulation, of the sensitivity of the length measurement system tests and two-face system tests in the B89.4.19 Standard to misalignments in laser trackers. We highlight key attributes of the testing strategy adopted in the Standard and propose new length measurement system tests that demonstrate improved sensitivity to some misalignments. Experimental results with a tracker that is not properly error corrected for the effects of the misalignments validate claims regarding the proposed new length tests.
- 1 January 2009
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 114 (1) , 21-35
ASME B89.4.19 Performance Evaluation Tests and Geometric Misalignments in Laser Trackers
Small and unintended offsets, tilts, and eccentricity of the mechanical and optical components in laser trackers introduce systematic errors in the measured spherical coordinates (angles and range readings) and possibly in the calculated lengths of reference artifacts. It is desirable that the tests described in the ASME B89.4.19 Standard [1] be sensitive to these geometric misalignments so that any resulting systematic errors are identified during performance evaluation. In this paper, we present some analysis, using error models and numerical simulation, of the sensitivity of the length measurement system tests and two-face system tests in the B89.4.19 Standard to misalignments in laser trackers. We highlight key attributes of the testing strategy adopted in the Standard and propose new length measurement system tests that demonstrate improved sensitivity to some misalignments. Experimental results with a tracker that is not properly error corrected for the effects of the misalignments validate claims regarding the proposed new length tests.
- 1 May 2008
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 113 (3) , 143-156
Uncertainty due to finite resolution measurements
We investigate the influence of finite resolution on measurement uncertainty from the perspective of the Guide to the Expression of Uncertainty in Measurement (GUM). Finite resolution in a measurement that is perturbed by Gaussian noise yields a distribution of results that strongly depends on the location of the true value relative to the resolution increment. We show that there is no simple expression relating the standard deviation of the distribution of measurement results to the associated uncertainty at a specified level of confidence. There is, however, an analytic relation between the mean value and the standard deviation of the measurement distribution. We further investigate the conflict between the GUM and ISO 14253-2 regarding the method of evaluating the standard uncertainty due to finite resolution and show that, on average, the GUM method is superior, but still approximate.
- 1 May 2008
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 113 (3) , 143-156
Uncertainty due to finite resolution measurements
We investigate the influence of finite resolution on measurement uncertainty from the perspective of the Guide to the Expression of Uncertainty in Measurement (GUM). Finite resolution in a measurement that is perturbed by Gaussian noise yields a distribution of results that strongly depends on the location of the true value relative to the resolution increment. We show that there is no simple expression relating the standard deviation of the distribution of measurement results to the associated uncertainty at a specified level of confidence. There is, however, an analytic relation between the mean value and the standard deviation of the measurement distribution. We further investigate the conflict between the GUM and ISO 14253-2 regarding the method of evaluating the standard uncertainty due to finite resolution and show that, on average, the GUM method is superior, but still approximate.
- 1 March 2001
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 106 (2) , 371-9
A careful consideration of the calibration concept
This paper presents a detailed discussion of the technical aspects of the calibration process with emphasis on the definition of the measurand, the conditions under which the calibration results are valid, and the subsequent use of the calibration results in measurement uncertainty statements. The concepts of measurement uncertainty, error, systematic error, and reproducibility are also addressed as they pertain to the calibration process.
- 1 March 2001
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 106 (2) , 371-9
A careful consideration of the calibration concept
This paper presents a detailed discussion of the technical aspects of the calibration process with emphasis on the definition of the measurand, the conditions under which the calibration results are valid, and the subsequent use of the calibration results in measurement uncertainty statements. The concepts of measurement uncertainty, error, systematic error, and reproducibility are also addressed as they pertain to the calibration process.