Chris Blackburn
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chris Blackburn has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Bala Muralikrishnan
National Institute of Standards and Technology, Physical Measurement Laboratory, Sensor Science Division, Gaithersburg, MD 20899, USA
5 shared publications - Daniel Sawyer
National Institute of Standards and Technology, Physical Measurement Laboratory, Sensor Science Division, Gaithersburg, MD 20899, USA
4 shared publications - Steven D. Phillips
National Institute of Standards and Technology, Gaithersburg, MD 20899
4 shared publications Brian Parry
The Boeing Company Seattle, WA 98108
1 shared publication- Bruce R. Borchardt
Precision Engineering Division, Manufacturing Engineering Laboratory, National Institute of Standards and Technology, Gaithersburg, MD 20899-8211
1 shared publication - Craig M. Shakarji
Mem. ASME Physical Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, MD 20899
1 shared publication
Latest Publications
- 1 December 2014
- Published by NCSL International in NCSLI Measure
- Vol. 9 (4) , 40-45
In-situ Temperature Calibration Capability for Dimensional Metrology
The Dimensional Metrology Group (DMG) at the National Institute of Standards and Technology (NIST) has developed a new in-situ temperature calibration system. This paper discusses the system components, an in-situ calibration procedure, and the uncertainty sources involved in the calibration process. It also presents an uncertainty budget, and examines it with a Monte Carlo simulation. This system enables the DMG to perform quicker in-situ temperature calibration, at frequent intervals with minimal downtime, and provides lower uncertainties for the dimensional measurements.
- 1 December 2014
- Published by NCSL International in NCSLI Measure
- Vol. 9 (4) , 40-45
In-situ Temperature Calibration Capability for Dimensional Metrology
The Dimensional Metrology Group (DMG) at the National Institute of Standards and Technology (NIST) has developed a new in-situ temperature calibration system. This paper discusses the system components, an in-situ calibration procedure, and the uncertainty sources involved in the calibration process. It also presents an uncertainty budget, and examines it with a Monte Carlo simulation. This system enables the DMG to perform quicker in-situ temperature calibration, at frequent intervals with minimal downtime, and provides lower uncertainties for the dimensional measurements.
- 1 December 2012
- Published by NCSL International in NCSLI Measure
- Vol. 7 (4) , 28-33
High Accuracy Measurements Using a Scanning System with a Single Point Triangulation Sensor
The capabilities of non-contact laser spot triangulation sensors for high accuracy measurements have slowly increased over the past decade, and now have usable resolution below 0.1 μm. The Dimensional Metrology Group at the National Institute of Standards and Technology (NIST) has developed a simple scanning system to work with these sensors, and presents the system details and data from a variety of geometries. The features measured include screw threads, fuel cell channels, and computer tomographic (CT) scanner phantoms.
- 1 December 2012
- Published by NCSL International in NCSLI Measure
- Vol. 7 (4) , 28-33
High Accuracy Measurements Using a Scanning System with a Single Point Triangulation Sensor
The capabilities of non-contact laser spot triangulation sensors for high accuracy measurements have slowly increased over the past decade, and now have usable resolution below 0.1 μm. The Dimensional Metrology Group at the National Institute of Standards and Technology (NIST) has developed a simple scanning system to work with these sensors, and presents the system details and data from a variety of geometries. The features measured include screw threads, fuel cell channels, and computer tomographic (CT) scanner phantoms.
- 1 January 2012
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 117, 216-30
A Model for Geometry-Dependent Errors in Length Artifacts
We present a detailed model of dimensional changes in long length artifacts, such as step gauges and ball bars, due to bending under gravity. The comprehensive model is based on evaluation of the gauge points relative to the neutral bending surface. It yields the errors observed when the gauge points are located off the neutral bending surface of a bar or rod but also reveals the significant error associated with out-of-straightness of a bar or rod even if the gauge points are located in the neutral bending surface. For example, one experimental result shows a length change of greater than 1.5 µm on a 1 m ball bar with an out-of-straightness of 0.4 mm. This and other results are in agreement with the model presented in this paper.
- 1 January 2012
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 117, 216-30
A Model for Geometry-Dependent Errors in Length Artifacts
We present a detailed model of dimensional changes in long length artifacts, such as step gauges and ball bars, due to bending under gravity. The comprehensive model is based on evaluation of the gauge points relative to the neutral bending surface. It yields the errors observed when the gauge points are located off the neutral bending surface of a bar or rod but also reveals the significant error associated with out-of-straightness of a bar or rod even if the gauge points are located in the neutral bending surface. For example, one experimental result shows a length change of greater than 1.5 µm on a 1 m ball bar with an out-of-straightness of 0.4 mm. This and other results are in agreement with the model presented in this paper.
- 1 September 2010
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 115 (5) , 291-301
Measuring scale errors in a laser tracker's horizontal angle encoder through simple length measurement and two-face system tests
We describe a method to estimate the scale errors in the horizontal angle encoder of a laser tracker in this paper. The method does not require expensive instrumentation such as a rotary stage or even a calibrated artifact. An uncalibrated but stable length is realized between two targets mounted on stands that are at tracker height. The tracker measures the distance between these two targets from different azimuthal positions (say, in intervals of 20° over 360°). Each target is measured in both front face and back face. Low order harmonic scale errors can be estimated from this data and may then be used to correct the encoder’s error map to improve the tracker’s angle measurement accuracy. We have demonstrated this for the second order harmonic in this paper. It is important to compensate for even order harmonics as their influence cannot be removed by averaging front face and back face measurements whereas odd orders can be removed by averaging. We tested six trackers from three different manufacturers. Two of those trackers are newer models introduced at the time of writing of this paper. For older trackers from two manufacturers, the length errors in a 7.75 m horizontal length placed 7 m away from a tracker were of the order of ± 65 μm before correcting the error map. They reduced to less than ± 25 μm after correcting the error map for second order scale errors. Newer trackers from the same manufacturers did not show this error. An older tracker from a third manufacturer also did not show this error.
- 1 September 2010
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 115 (5) , 291-301
Measuring scale errors in a laser tracker's horizontal angle encoder through simple length measurement and two-face system tests
We describe a method to estimate the scale errors in the horizontal angle encoder of a laser tracker in this paper. The method does not require expensive instrumentation such as a rotary stage or even a calibrated artifact. An uncalibrated but stable length is realized between two targets mounted on stands that are at tracker height. The tracker measures the distance between these two targets from different azimuthal positions (say, in intervals of 20° over 360°). Each target is measured in both front face and back face. Low order harmonic scale errors can be estimated from this data and may then be used to correct the encoder’s error map to improve the tracker’s angle measurement accuracy. We have demonstrated this for the second order harmonic in this paper. It is important to compensate for even order harmonics as their influence cannot be removed by averaging front face and back face measurements whereas odd orders can be removed by averaging. We tested six trackers from three different manufacturers. Two of those trackers are newer models introduced at the time of writing of this paper. For older trackers from two manufacturers, the length errors in a 7.75 m horizontal length placed 7 m away from a tracker were of the order of ± 65 μm before correcting the error map. They reduced to less than ± 25 μm after correcting the error map for second order scale errors. Newer trackers from the same manufacturers did not show this error. An older tracker from a third manufacturer also did not show this error.
- 1 January 2009
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 114 (1) , 21-35
ASME B89.4.19 Performance Evaluation Tests and Geometric Misalignments in Laser Trackers
Small and unintended offsets, tilts, and eccentricity of the mechanical and optical components in laser trackers introduce systematic errors in the measured spherical coordinates (angles and range readings) and possibly in the calculated lengths of reference artifacts. It is desirable that the tests described in the ASME B89.4.19 Standard [1] be sensitive to these geometric misalignments so that any resulting systematic errors are identified during performance evaluation. In this paper, we present some analysis, using error models and numerical simulation, of the sensitivity of the length measurement system tests and two-face system tests in the B89.4.19 Standard to misalignments in laser trackers. We highlight key attributes of the testing strategy adopted in the Standard and propose new length measurement system tests that demonstrate improved sensitivity to some misalignments. Experimental results with a tracker that is not properly error corrected for the effects of the misalignments validate claims regarding the proposed new length tests.
- 1 January 2009
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 114 (1) , 21-35
ASME B89.4.19 Performance Evaluation Tests and Geometric Misalignments in Laser Trackers
Small and unintended offsets, tilts, and eccentricity of the mechanical and optical components in laser trackers introduce systematic errors in the measured spherical coordinates (angles and range readings) and possibly in the calculated lengths of reference artifacts. It is desirable that the tests described in the ASME B89.4.19 Standard [1] be sensitive to these geometric misalignments so that any resulting systematic errors are identified during performance evaluation. In this paper, we present some analysis, using error models and numerical simulation, of the sensitivity of the length measurement system tests and two-face system tests in the B89.4.19 Standard to misalignments in laser trackers. We highlight key attributes of the testing strategy adopted in the Standard and propose new length measurement system tests that demonstrate improved sensitivity to some misalignments. Experimental results with a tracker that is not properly error corrected for the effects of the misalignments validate claims regarding the proposed new length tests.