JGJulieta Alejandra Yamin Garreton

Julieta Alejandra Yamin Garreton

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Julieta Alejandra Yamin Garreton has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Confort visual en galerías exteriores: deslumbramiento versus acceso a la vista al exterior. Caso de estudio: red de sombreado

    by Julieta Yamin-Garretón, Daniela Giuffré, Ayelén Villalba, Andrea Pattini

    La calidad de la vista y el desempeño lumínico de los dispositivos de sombreado se han estudiado principalmente en espacios interiores, pero aún no se han examinado de manera conjunta en galerías semiabiertas. Este trabajo evalúa el deslumbramiento y la calidad de la vista exterior de un sistema de sombreado tipo red de camuflaje con un 75% de cobertura. Se realizó un experimento semicontrolado en una galería de una vivienda orientada al noroeste con vistas a la cordillera de los Andes, en Mendoza, Argentina. Veinte personas evaluaron esta red en tres condiciones: sin sombreado, red desplegada y red plegada. Se tomaron medidas fotométricas y se aplicó un cuestionario sobre confort visual. Los resultados mostraron que el uso de la red reduce de manera significativa el deslumbramiento y mejora el confort térmico, aunque disminuye la calidad de la vista exterior, poniéndose en evidencia la dificultad de lograr un equilibrio entre la calidad de visual y el control del deslumbramiento.

  • Open Access

    User evaluations of fabric shades with sun in the field of view: Glare model performance and implications for EN14501 Classification

    by Caroline Karmann, Jan Wienold, Julieta Alejandra Yamin Garreton, Ayelén María Villalba, Andrea Elvira Pattini, Marilyne Andersen


  • Open Access

    Propuesta metodológica para medir el deslumbramiento en ambientes interiores mediante cuatro rangos de apertura ocular

    by Julieta Yamin-Garretón, Darío Jaime, Maureen De Gastines, Emanuel Schumacher, Andrea Pattini

    El desarrollo de modelos de deslumbramiento contribuye a una mejor evaluación del confort visual de los ocupantes en espacios interiores. Los indicadores oculares pueden ser una herramienta adecuada para evaluar el deslumbramiento de manera dinámica en climas soleados para evitar las molestias visuales. En este trabajo, se mide el grado de apertura ocular y se propone su medición en cuatro rangos (oclusión, semi-oclusión, semi-apertura y apertura) por medio de un eye-tracker. El objetivo de este trabajo fue evaluar de qué manera se relaciona el grado de apertura ocular con los niveles de iluminancia vertical (Ev) inferiores a 2484 lx (valor donde aparece la sensación de deslumbramiento molesto), así como determinar si la percepción subjetiva del deslumbramiento de las personas corresponde a los rangos de deslumbramientos propuestos por Wienold (2019). Estos parámetros se midieron en tres condiciones de deslumbramiento percibido (notable, perturbador e intolerable). Los resultados mostraron que la medición de apertura ocular en cuatro rangos, tiene el potencial de cuantificar de manera objetiva y dinámica la sensación de deslumbramiento en todos los escenarios evaluados y en cuanto a su relación con los valores de Ev de referencia, los valores percibidos como notable y perturbador, fueron inferiores a los valores de referencia, mientras que los valores percibidos como intolerable fueron coincidentes.


  • Open Access

    Deslumbramiento molesto en textiles: métricas basadas en efecto de saturación y/o contraste

    by Julieta Yamin, Ayelén Villalba, Maureen De Gastines, Roberto Rodríguez, Andrea Pattini

    Se evaluó el nivel de deslumbramiento producido por nueve textiles. Este tipo de sistema de sombreado muchas veces es comercializado sin una adecuada caracterización fotométrica, lo que conlleva a una aplicación inadecuada de los mismos, produciendo incrementos en las molestias visuales de los usuarios y mayores consumos de energía. Para evaluar el deslumbramiento, se calcularon cuatro métricas diferentes. Estas métricas están basadas en el efecto de saturación, contraste o ambas. Asimismo, se evaluó qué métricas conviene utilizar, si una específica a la condición lumínica predominante, una métrica general aplicable a todas las condiciones lumínicas o una combinación de ambas. En este estudio se observó que la métrica de contraste fue más sensible al deslumbramiento, pero la utilización de dos métricas de una manera aditiva ofrece una mejor jerarquización de los textiles. Como objetivo final se propone un sistema de puntuación para evaluar el comportamiento de textiles frente al deslumbramiento.


  • The impact of woven shade fabrics on correlated colour temperature and illuminance with daylighting

    by A Villalba, J Yamín Garretón, A Pattini

    When solar radiation passes through a window, its spectral composition changes due to the presence of shades and glazing. While many studies have analysed the impact of different types of glass on correlated colour temperature (CCT), there are only a few cases in which the effect of shading and daylighting systems on this parameter was tested. This work analyses the impact of woven shade fabrics on the spectrum and intensity of daylight conditions in indoor spaces. A combined analysis of horizontal illuminance ( Eh) and CCT was performed. It focused on the impact that physical properties of woven shade fabrics – colour and openness factor (OF) – had on the CCT and Eh values. In this study, 11 fabrics with different colours (white, grey and black) and varying OF were analysed. For the set of studied woven shade fabrics, it was found that fabric OF and colour had a significant effect on CCT and Eh. Results show that white and grey fabrics provided spaces with lower values of CCT than black fabrics. CCT values were compared with those proposed by standard EN 12464-1:2011.


  • Open Access

    Effect of Roller Shades on Chromaticity and Colour Rendering Performance of Transmitted Daylight

    by Ayelén Villalba, Erica Correa, Julieta Yamín, Andrea Pattini

    Several studies have focused on the performance of roller shades in terms of glare, outdoor vision, daylight availability and energy performance. Currently, other parameters linked to visual amenity, such as chromaticity and colour rendition, are becoming relevant. When solar radiation passes through a window, it changes its spectral composition due to the presence of the solar shading system and the glazing. Against this background, the present study focuses on the spectral transmittance of eleven woven screen fabrics and its influence on the chromaticity and colour rendition. Results show that dark-coloured woven screen shades provide higher correlated colour temperature (CCT) values (range 6470 K - 6479 K) and therefore would produce “cooler” visual environments, while light-coloured woven screen shades provide lower CCT values (range 5210 K - 5644 K) creating “warmer” visual environments. Regarding colour rendering metrics, the light transmitted through all the studied woven shades shows excellent colour rendition. Finally, it is concluded that the combined analysis of optical properties, spectral data and its impact on parameters that determine the quality of lighting in an interior space enables an understanding of woven screens performance, which results in the possibility of taking appropriate decisions when selecting woven shades.


  • Open Access

    Comparative Investigation of Daylight Glare Probability (DGP) Comfort Classes in Clear Sky Condition

    by Conicet Inahe, Juan Manuel Monteoliva, Julieta A. Yamín Garretón, Andrea E. Pattini

    Glare is considered one of the most important variables to reach visual comfort and visual quality. It represents one of the fundamental barriers for an effective use of daylighting in buildings. One of the best performing and robust glare prediction models, relative to other available metrics, is a Daylight Glare Probability (DGP). Based on a validated and precise methodology (RADIANCE) the aim of this work is to compare the DGP model (original cut-off values) with new cut-off values that differ according to the time of day (morning, noon and afternoon). Both cut-off values were compared at more than 300 simulated conditions of daylighting in an interior space. This work offers the originality of studying recently proposed cut-off values in climate luminous with predominant clear sky conditions. Currently, the application of these new cutoff values is reduced to the field of science or simulation professionals. The results showed important differences (64.86%) between the categories proposed by both cut-off values. Nevertheless, these differences do not have a significant impact in glare prediction (< 2.7%), in terms of glare absence (DGP 0.38). This analysis made it possible: (i) to regionally apply the main current corpus criteria regarding glare issues as well as emergent proposals and (ii) to present new experimental data aimed at helping the field and, together with other works, improving the tools used by professionals on a daily basis.


  • Open Access

    Confort visual en oficinas, factor temporal en la evaluación de deslumbramiento

    by J. Yamin, A. Pattini, E. Colombo

    Para lograr los beneficios de iluminar con luz natural espacios de trabajo, hay que evitar que la luz natural sea bloqueada por el potencial riesgo de deslumbramiento. Para lograr una adecuada caracterización del mismo es importante considerar la percepción del tiempo de exposición de la fuente en el campo de visión (Aspecto no incluido en los modelos de deslumbramiento). Para determinar de qué manera influye este aspecto perceptual en la sensación de deslumbramiento se evaluaron dos escenarios con dos tipos de manchas solares sobre el puesto de trabajo: 1) Con mayor profundidad de ingreso y más tiempo en el campo de visión, 2) Con menor profundidad de ingreso y menos tiempo en el campo de visión. Se midieron parámetros subjetivos (GSV) y variables fotométricas (DGP, EV y CL). Siendo la principal variable explicativa la EV (rho=0.51). Observándose también una mayor tolerancia al deslumbramiento por el efecto transitorio de la fuente.


  • Open Access

    A global evaluation of discomfort glare metrics in real office spaces with presence of direct sunlight

    by Julieta Alejandra Yamin Garretón, Elisa Margarita Colombo, Andrea Elvira Pattini


  • An epidemiological approach to daylight discomfort glare

    by Roberto German Rodriguez, Julieta A. Yamín Garretón, Andrea E. Pattini