Brienne N. Seiner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Brienne N. Seiner has a total of 80 co-authors. Here are the top co-authors by number of shared publications:
- Gregg J. Lumetta
Pacific Northwest National Laboratory
5 shared publications - Nathan P. Bessen
Pacific Northwest National Laboratory
4 shared publications - Samuel A. Bryan
Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)
4 shared publications Alyssa F. Espley
Pacific Northwest National Laboratory
3 shared publicationsErin Finn
Pacific Northwest National Laboratory
3 shared publications- Heather M. Felmy
Pacific Northwest National Laboratory
3 shared publications
Latest Publications
- 18 August 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (35) , 19019-19027
Automated pH Monitoring and Control of TALSPEAK and Advanced TALSPEAK Processes
Maintaining pH in an operable range is key in many industrial processes, where automating pH correction and control can enable significant advances in process efficiency. One such process is solvent extraction. In solvent extraction, the pH can directly influence separation by altering the extraction of different species. Solvent extraction procedures for separating components of used nuclear fuel, such as TALSPEAK and Advanced TALSPEAK, are examples of this. In these processes, the extraction of trivalent lanthanides and actinides is pH-dependent, with more acidic conditions causing greater metal extraction. However, the pH can be challenging to control. Here, automated pH control has been demonstrated using robust, Raman-based pH measurement that informed the control software connected to programmable logic controllers (PLCs). The use of Raman spectroscopy paired with a chemometric model has been applied to the feed solutions for TALSPEAK and Advanced TALSPEAK processes and is used to demonstrate effective, robust, and near instantaneous pH measurement. The result of this measurement was then fed into a PLC instrument that had been programmed to maintain a constant pH. When the pH was purposely perturbed by adding an acid or base, the PLC was able to automatically correct the pH and, consequently, control the desired extraction of metal ions. The analytical approach and performance to automated, real-time process control are described here.
- 18 August 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (35) , 19019-19027
Automated pH Monitoring and Control of TALSPEAK and Advanced TALSPEAK Processes
Maintaining pH in an operable range is key in many industrial processes, where automating pH correction and control can enable significant advances in process efficiency. One such process is solvent extraction. In solvent extraction, the pH can directly influence separation by altering the extraction of different species. Solvent extraction procedures for separating components of used nuclear fuel, such as TALSPEAK and Advanced TALSPEAK, are examples of this. In these processes, the extraction of trivalent lanthanides and actinides is pH-dependent, with more acidic conditions causing greater metal extraction. However, the pH can be challenging to control. Here, automated pH control has been demonstrated using robust, Raman-based pH measurement that informed the control software connected to programmable logic controllers (PLCs). The use of Raman spectroscopy paired with a chemometric model has been applied to the feed solutions for TALSPEAK and Advanced TALSPEAK processes and is used to demonstrate effective, robust, and near instantaneous pH measurement. The result of this measurement was then fed into a PLC instrument that had been programmed to maintain a constant pH. When the pH was purposely perturbed by adding an acid or base, the PLC was able to automatically correct the pH and, consequently, control the desired extraction of metal ions. The analytical approach and performance to automated, real-time process control are described here.
- Open Access
- 30 April 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (18) , 18238-18250
Real-Time Automated pH Control within Batch Processes Relying on Raman pH Measurement
- 30 April 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (18) , 18238-18250
Open AccessReal-Time Automated pH Control within Batch Processes Relying on Raman pH Measurement
- Open Access
- 20 March 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (12) , 11796-11805
Spectroscopic Online Monitoring: Using a Multi-Track Visible Spectrometer to Facilitate a Mass Balance Study in a Simulated TALSPEAK Process
Nuclear energy is a promising low-carbon energy candidate to meet the increased demand for green energy, where the integration of fuel recycling can have significant benefits for material usage and waste reduction. Utilizing in situ monitoring tools can provide ample opportunities to better control and safeguard nuclear material recycle processes while also offering knowledge and insight into real-time solution properties. The simultaneous measurement of analytical targets in multiple process locations can enable real-time mass balance and material accountancy calculations. This is demonstrated here with a mass balance study of Nd3+ on countercurrent aqueous/organic metal extraction within a single centrifugal contactor. The Nd3+ concentration was simultaneously monitored at the inlets and outlets of both aqueous and organic phases using a visible absorbance detector that allowed for the simultaneous measurement of up to six locations. The Nd3+ concentration was calculated by using chemical data science algorithms, where model training sets were collected on a single track of the detector. The discussion includes addressing the challenges of using a model collected on a single track and applying it as a model across the other tracks on the detector. Each track of the detector corresponds to one measurement location on the contactor. The difference in the integrated moles of Nd3+ between the inlet and outlet at the end of the experiment was near zero, indicating that the mass balance of this experiment was maintained. Overall, the online spectroscopic monitoring was able to follow changing solution conditions and accurately measure the concentration of Nd3+ in different locations within the contactor system.
- 20 March 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (12) , 11796-11805
Open AccessSpectroscopic Online Monitoring: Using a Multi-Track Visible Spectrometer to Facilitate a Mass Balance Study in a Simulated TALSPEAK Process
Nuclear energy is a promising low-carbon energy candidate to meet the increased demand for green energy, where the integration of fuel recycling can have significant benefits for material usage and waste reduction. Utilizing in situ monitoring tools can provide ample opportunities to better control and safeguard nuclear material recycle processes while also offering knowledge and insight into real-time solution properties. The simultaneous measurement of analytical targets in multiple process locations can enable real-time mass balance and material accountancy calculations. This is demonstrated here with a mass balance study of Nd3+ on countercurrent aqueous/organic metal extraction within a single centrifugal contactor. The Nd3+ concentration was simultaneously monitored at the inlets and outlets of both aqueous and organic phases using a visible absorbance detector that allowed for the simultaneous measurement of up to six locations. The Nd3+ concentration was calculated by using chemical data science algorithms, where model training sets were collected on a single track of the detector. The discussion includes addressing the challenges of using a model collected on a single track and applying it as a model across the other tracks on the detector. Each track of the detector corresponds to one measurement location on the contactor. The difference in the integrated moles of Nd3+ between the inlet and outlet at the end of the experiment was near zero, indicating that the mass balance of this experiment was maintained. Overall, the online spectroscopic monitoring was able to follow changing solution conditions and accurately measure the concentration of Nd3+ in different locations within the contactor system.
- Open Access
- 10 December 2024
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 9 (51) , 50357-50366
Machine Learning Prediction of Nitric Acid Extraction Behavior in PUREX Process
Plutonium uranium reduction extraction (PUREX) is a liquid-liquid extraction process used to recover plutonium (Pu) and uranium (U) from irradiated uranium fuel for various nuclear-related applications. Despite extensive efforts, quantitative prediction of liquid-liquid extraction parameters, i.e., distribution ratios and separation factors, of the process remains challenging. Existing thermodynamic models are difficult to develop and often have limited utility due to the complexity of the aqueous feed. Nitric acid is a critical component of the PUREX system, both as a driving force for dissolving irradiated fuels in preprocessing stages, as well as being efficiently extracted by tributyl phosphate (TBP). Models to understand nitric acid's distribution behavior is therefore a prerequisite to predict actinide extraction. In this work, we compiled a wealth of solvent extraction literature data and built machine learning (ML) models capable of predicting the organic phase nitric acid equilibrium concentration from initial acid and TBP concentrations across a variety of diluents. Our results demonstrate that ML is highly capable of predicting nitric acid extraction behavior in PUREX systems, and the resultant ML-aided response surfaces demonstrate promising progress as an in silico aid for optimizing the design of experiments for future work with the PUREX process.
- 10 December 2024
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 9 (51) , 50357-50366
Open AccessMachine Learning Prediction of Nitric Acid Extraction Behavior in PUREX Process
Plutonium uranium reduction extraction (PUREX) is a liquid-liquid extraction process used to recover plutonium (Pu) and uranium (U) from irradiated uranium fuel for various nuclear-related applications. Despite extensive efforts, quantitative prediction of liquid-liquid extraction parameters, i.e., distribution ratios and separation factors, of the process remains challenging. Existing thermodynamic models are difficult to develop and often have limited utility due to the complexity of the aqueous feed. Nitric acid is a critical component of the PUREX system, both as a driving force for dissolving irradiated fuels in preprocessing stages, as well as being efficiently extracted by tributyl phosphate (TBP). Models to understand nitric acid's distribution behavior is therefore a prerequisite to predict actinide extraction. In this work, we compiled a wealth of solvent extraction literature data and built machine learning (ML) models capable of predicting the organic phase nitric acid equilibrium concentration from initial acid and TBP concentrations across a variety of diluents. Our results demonstrate that ML is highly capable of predicting nitric acid extraction behavior in PUREX systems, and the resultant ML-aided response surfaces demonstrate promising progress as an in silico aid for optimizing the design of experiments for future work with the PUREX process.
- 28 July 2024
- Published by Taylor & Francis in Solvent Extraction and Ion Exchange
- Vol. 42 (5) , 347-380
A Review of Online Monitoring within Used Nuclear Fuel Recycling Processes
- 28 July 2024
- Published by Taylor & Francis in Solvent Extraction and Ion Exchange
- Vol. 42 (5) , 347-380
A Review of Online Monitoring within Used Nuclear Fuel Recycling Processes
- 7 February 2023
- Published by Elsevier in Cement and Concrete Composites
- Vol. 138
Cerium oxide impact on fresh and hardened properties of cementitious materials
- 7 February 2023
- Published by Elsevier in Cement and Concrete Composites
- Vol. 138
Cerium oxide impact on fresh and hardened properties of cementitious materials
- Open Access
- 20 July 2021
- Published by MDPI AG in Separations
- Vol. 8 (7) , 104
Separation of Lanthanide Isotopes from Mixed Fission Product Samples
The measurement of radioactive fission products from nuclear events has important implications for nuclear data production, environmental monitoring, and nuclear forensics. In a previous paper, the authors reported the optimization of an intra-group lanthanide separation using LN extraction resin from Eichrom Technologies®, Inc. and a nitric acid gradient. In this work, the method was demonstrated for the separation and quantification of multiple short-lived fission product lanthanide isotopes from a fission product sample produced from the thermal irradiation of highly enriched uranium. The separations were performed in parallel in quadruplicate with reproducible results and high decontamination factors for 153Sm, 156Eu, and 161Tb. Based on the results obtained here, the fission yields for 144Ce, 153Sm, 156Eu, and 161Tb are consistent with published fission yields. This work demonstrates the effectiveness of the separations for the intended application of short-lived lanthanide fission product analysis requiring high decontamination factors.
- 20 July 2021
- Published by MDPI AG in Separations
- Vol. 8 (7) , 104
Open AccessSeparation of Lanthanide Isotopes from Mixed Fission Product Samples
The measurement of radioactive fission products from nuclear events has important implications for nuclear data production, environmental monitoring, and nuclear forensics. In a previous paper, the authors reported the optimization of an intra-group lanthanide separation using LN extraction resin from Eichrom Technologies®, Inc. and a nitric acid gradient. In this work, the method was demonstrated for the separation and quantification of multiple short-lived fission product lanthanide isotopes from a fission product sample produced from the thermal irradiation of highly enriched uranium. The separations were performed in parallel in quadruplicate with reproducible results and high decontamination factors for 153Sm, 156Eu, and 161Tb. Based on the results obtained here, the fission yields for 144Ce, 153Sm, 156Eu, and 161Tb are consistent with published fission yields. This work demonstrates the effectiveness of the separations for the intended application of short-lived lanthanide fission product analysis requiring high decontamination factors.
- 19 November 2020
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 327 (1) , 457-463
Development of a separation method for rare earth elements using LN resin
- 19 November 2020
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 327 (1) , 457-463
Development of a separation method for rare earth elements using LN resin
- 29 October 2020
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 326 (3) , 1669-1678
Measurement of distribution coefficients on TODGA resin and development of a group separation for mixed activation and fission product samples
- 29 October 2020
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 326 (3) , 1669-1678
Measurement of distribution coefficients on TODGA resin and development of a group separation for mixed activation and fission product samples
- 20 November 2015
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 307 (3) , 1737-1742
Rapid quantitation of uranium from mixed fission product samples
- 20 November 2015
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 307 (3) , 1737-1742
Rapid quantitation of uranium from mixed fission product samples