Kristy K. Brock
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kristy K. Brock has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Cynthia Ménard
Radiation Medicine Program, Princess Margaret Hospital, University Health Network and the University of Toronto, Toronto, Ontario M5G 2M9, Canada
2 shared publications- Deirdre M. McGrath
Radiation Medicine Program, Princess Margaret Hospital, University Health Network, Toronto, Ontario M5G 2M9, Canada
2 shared publications Michael A S Jewett
Departments of Surgery (Urology) and Surgical Oncology, Princess Margaret Cancer Centre, University Health Network and University of Toronto, Toronto, Ontario M5G 2M9, Canada
2 shared publicationsNavid Samavati
Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario M5S 3G9
2 shared publications- Theodorus H. van der Kwast
Laboratory Medicine and Pathobiology, University of Toronto, Toronto, Canada
2 shared publications Jenny Lee
Radiation Medicine Program, Princess Margaret Hospital, University Health Network, Toronto, Ontario M5G 2M9, Canada
1 shared publication
Latest Publications
- 16 January 2017
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 62 (3) , 1126-1148
MR elastography to measure the effects of cancer and pathology fixation on prostate biomechanics, and comparison with T 1 , T 2 and ADC
MRI is under evaluation for image-guided intervention for prostate cancer. The sensitivity and specificity of MRI parameters is determined via correlation with the gold-standard of histopathology. Whole-mount histopathology of prostatectomy specimens can be digitally registered to in vivo imaging for correlation. When biomechanical-based deformable registration is employed to account for deformation during histopathology processing, the ex vivo biomechanical properties are required. However, these properties are altered by pathology fixation, and vary with disease. Hence, this study employs magnetic resonance elastography (MRE) to measure ex vivo prostate biomechanical properties before and after fixation. A quasi-static MRE method was employed to measure high resolution maps of Young’s modulus ( E ) before and after fixation of canine prostate and prostatectomy specimens ( n = 4) from prostate cancer patients who had previously received radiation therapy. For comparison, T 1 , T 2 and apparent diffusion coefficient (ADC) were measured in parallel. E (kPa) varied across clinical anatomy and for histopathology-identified tumor: peripheral zone: 99(±22), central gland: 48(±37), tumor: 85(±53), and increased consistently with fixation (factor of 11 ± 5; p < 0.02). T 2 decreased consistently with fixation, while changes in T 1 and ADC were more complex and inconsistent. The biomechanics of the clinical prostate specimens varied greatly with fixation, and to a lesser extent with disease and anatomy. The data obtained will improve the precision of prostate pathology correlation, leading to more accurate disease detection and targeting.
- 16 January 2017
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 62 (3) , 1126-1148
MR elastography to measure the effects of cancer and pathology fixation on prostate biomechanics, and comparison with T 1 , T 2 and ADC
MRI is under evaluation for image-guided intervention for prostate cancer. The sensitivity and specificity of MRI parameters is determined via correlation with the gold-standard of histopathology. Whole-mount histopathology of prostatectomy specimens can be digitally registered to in vivo imaging for correlation. When biomechanical-based deformable registration is employed to account for deformation during histopathology processing, the ex vivo biomechanical properties are required. However, these properties are altered by pathology fixation, and vary with disease. Hence, this study employs magnetic resonance elastography (MRE) to measure ex vivo prostate biomechanical properties before and after fixation. A quasi-static MRE method was employed to measure high resolution maps of Young’s modulus ( E ) before and after fixation of canine prostate and prostatectomy specimens ( n = 4) from prostate cancer patients who had previously received radiation therapy. For comparison, T 1 , T 2 and apparent diffusion coefficient (ADC) were measured in parallel. E (kPa) varied across clinical anatomy and for histopathology-identified tumor: peripheral zone: 99(±22), central gland: 48(±37), tumor: 85(±53), and increased consistently with fixation (factor of 11 ± 5; p < 0.02). T 2 decreased consistently with fixation, while changes in T 1 and ADC were more complex and inconsistent. The biomechanics of the clinical prostate specimens varied greatly with fixation, and to a lesser extent with disease and anatomy. The data obtained will improve the precision of prostate pathology correlation, leading to more accurate disease detection and targeting.
- 9 December 2014
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 60 (1) , 195-209
Effect of material property heterogeneity on biomechanical modeling of prostate under deformation
Biomechanical model based deformable image registration has been widely used to account for prostate deformation in various medical imaging procedures. Biomechanical material properties are important components of a biomechanical model. In this study, the effect of incorporating tumor-specific material properties in the prostate biomechanical model was investigated to provide insight into the potential impact of material heterogeneity on the prostate deformation calculations. First, a simple spherical prostate and tumor model was used to analytically describe the deformations and demonstrate the fundamental effect of changes in the tumor volume and stiffness in the modeled deformation. Next, using a clinical prostate model, a parametric approach was used to describe the variations in the heterogeneous prostate model by changing tumor volume, stiffness, and location, to show the differences in the modeled deformation between heterogeneous and homogeneous prostate models. Finally, five clinical prostatectomy examples were used in separately performed homogeneous and heterogeneous biomechanical model based registrations to describe the deformations between 3D reconstructed histopathology images and ex vivo magnetic resonance imaging, and examine the potential clinical impact of modeling biomechanical heterogeneity of the prostate. The analytical formulation showed that increasing the tumor volume and stiffness could significantly increase the impact of the heterogeneous prostate model in the calculated displacement differences compared to the homogeneous model. The parametric approach using a single prostate model indicated up to 4.8 mm of displacement difference at the tumor boundary compared to a homogeneous model. Such differences in the deformation of the prostate could be potentially clinically significant given the voxel size of the ex vivo MR images (0.3 × 0.3 × 0.3 mm). However, no significant changes in the registration accuracy were observed using heterogeneous models for the limited number of clinical prostatectomy patients modeled and evaluated in this study.
- 9 December 2014
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 60 (1) , 195-209
Effect of material property heterogeneity on biomechanical modeling of prostate under deformation
Biomechanical model based deformable image registration has been widely used to account for prostate deformation in various medical imaging procedures. Biomechanical material properties are important components of a biomechanical model. In this study, the effect of incorporating tumor-specific material properties in the prostate biomechanical model was investigated to provide insight into the potential impact of material heterogeneity on the prostate deformation calculations. First, a simple spherical prostate and tumor model was used to analytically describe the deformations and demonstrate the fundamental effect of changes in the tumor volume and stiffness in the modeled deformation. Next, using a clinical prostate model, a parametric approach was used to describe the variations in the heterogeneous prostate model by changing tumor volume, stiffness, and location, to show the differences in the modeled deformation between heterogeneous and homogeneous prostate models. Finally, five clinical prostatectomy examples were used in separately performed homogeneous and heterogeneous biomechanical model based registrations to describe the deformations between 3D reconstructed histopathology images and ex vivo magnetic resonance imaging, and examine the potential clinical impact of modeling biomechanical heterogeneity of the prostate. The analytical formulation showed that increasing the tumor volume and stiffness could significantly increase the impact of the heterogeneous prostate model in the calculated displacement differences compared to the homogeneous model. The parametric approach using a single prostate model indicated up to 4.8 mm of displacement difference at the tumor boundary compared to a homogeneous model. Such differences in the deformation of the prostate could be potentially clinically significant given the voxel size of the ex vivo MR images (0.3 × 0.3 × 0.3 mm). However, no significant changes in the registration accuracy were observed using heterogeneous models for the limited number of clinical prostatectomy patients modeled and evaluated in this study.
- 1 July 2014
- Published by Elsevier in Seminars in Radiation Oncology
- Vol. 24 (3) , 169-174
Point: Principles of Magnetic Resonance Imaging Integration in a Computed Tomography–Based Radiotherapy Workflow
- 1 July 2014
- Published by Elsevier in Seminars in Radiation Oncology
- Vol. 24 (3) , 169-174
Point: Principles of Magnetic Resonance Imaging Integration in a Computed Tomography–Based Radiotherapy Workflow