DMDeirdre M. McGrath

Deirdre M. McGrath

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Deirdre M. McGrath has a total of 105 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    In silico evaluation and optimisation of magnetic resonance elastography of the liver

    by Deirdre M McGrath, Christopher R Bradley, Susan T Francis

    Objective. Magnetic resonance elastography (MRE) is widely adopted as a biomarker of liver fibrosis. However, in vivo MRE accuracy is difficult to assess. Approach. Finite element model (FEM) simulation was employed to evaluate liver MRE accuracy and inform methodological optimisation. MRE data was simulated in a 3D FEM of the human torso including the liver, and compared with spin-echo echo-planar imaging MRE acquisitions. The simulated MRE results were compared with the ground truth magnitude of the complex shear modulus (∣ G *∣) for varying: (1) ground truth liver ∣ G *∣; (2) simulated imaging resolution; (3) added noise; (4) data smoothing. Motion and strain-based signal-to-noise (SNR) metrics were evaluated on the simulated data as a means to select higher-quality voxels for preparation of acquired MRE summary statistics of ∣ G *∣. Main results. The simulated MRE accuracy for a given ground truth ∣ G *∣ was found to be a function of imaging resolution, motion-SNR and smoothing. At typical imaging resolutions, it was found that due to under-sampling of the MRE wave-field, combined with motion-related noise, the reconstructed simulated ∣ G *∣ could contain errors on the scale of the difference between liver fibrosis stages, e.g. 54% error for ground truth ∣ G *∣ = 1 kPa. Optimum imaging resolutions were identified for given ground truth ∣ G *∣ and motion-SNR levels. Significance. This study provides important knowledge on the accuracy and optimisation of liver MRE. For example, for motion-SNR ≤ 5, to distinguish between liver ∣ G *∣ of 2 and 3 kPa (i.e. early-stage liver fibrosis) it was predicted that the optimum isotropic voxel size is 4–6 mm.

  • MR elastography to measure the effects of cancer and pathology fixation on prostate biomechanics, and comparison with T 1 , T 2 and ADC

    by Deirdre M McGrath, Jenny Lee, Warren D Foltz, Navid Samavati, Theo van der Kwast, Michael A S Jewett, Peter Chung, Cynthia Ménard, Kristy K Brock

    MRI is under evaluation for image-guided intervention for prostate cancer. The sensitivity and specificity of MRI parameters is determined via correlation with the gold-standard of histopathology. Whole-mount histopathology of prostatectomy specimens can be digitally registered to in vivo imaging for correlation. When biomechanical-based deformable registration is employed to account for deformation during histopathology processing, the ex vivo biomechanical properties are required. However, these properties are altered by pathology fixation, and vary with disease. Hence, this study employs magnetic resonance elastography (MRE) to measure ex vivo prostate biomechanical properties before and after fixation. A quasi-static MRE method was employed to measure high resolution maps of Young’s modulus ( E ) before and after fixation of canine prostate and prostatectomy specimens ( n = 4) from prostate cancer patients who had previously received radiation therapy. For comparison, T 1 , T 2 and apparent diffusion coefficient (ADC) were measured in parallel. E (kPa) varied across clinical anatomy and for histopathology-identified tumor: peripheral zone: 99(±22), central gland: 48(±37), tumor: 85(±53), and increased consistently with fixation (factor of 11 ± 5; p < 0.02). T 2 decreased consistently with fixation, while changes in T 1 and ADC were more complex and inconsistent. The biomechanics of the clinical prostate specimens varied greatly with fixation, and to a lesser extent with disease and anatomy. The data obtained will improve the precision of prostate pathology correlation, leading to more accurate disease detection and targeting.


  • Evaluation of wave delivery methodology for brain MRE: Insights from computational simulations

    by Deirdre M. McGrath, Nishant Ravikumar, Leandro Beltrachini, Iain D. Wilkinson, Alejandro F. Frangi, Zeike A. Taylor

    Purpose: MR elastography (MRE) of the brain is being explored as a biomarker of neurodegenerative disease such as dementia. However, MRE measures for healthy brain have varied widely. Differing wave delivery methodologies may have influenced this, hence finite element‐based simulations were performed to explore this possibility.Methods: The natural frequencies of a series of cranial models were calculated, and MRE‐associated vibration was simulated for different wave delivery methods at varying frequency, using simple isotropic viscoelastic material models for the brain. Displacement fields and the corresponding brain constitutive properties estimated by standard inversion techniques were compared across delivery methods and frequencies.Results: The delivery methods produced widely different MRE displacement fields and inversions. Furthermore, resonances at natural frequencies influenced the displacement patterns. Consequently, some delivery methods led to lower inversion errors than others, and the error on the storage modulus varied by up to 11% between methods.Conclusion: Wave delivery has a considerable impact on brain MRE reliability. Assuming small variations in brain biomechanics, as recently reported to accompany neurodegenerative disease (e.g., 7% for Alzheimer's disease), the effect of wave delivery is important. Hence, a consensus should be established on a consistent methodology to ensure diagnostic and prognostic consistency. Magn Reson Med 78:341–356, 2017. © 2016 International Society for Magnetic Resonance in Medicine


  • Open Access

    T1 Relaxation Time in Lungs of Asymptomatic Smokers

    by Daniel F. Alamidi, Simon S. I. Kindvall, Penny L. Hubbard Cristinacce, Deirdre M. McGrath, Simon S. Young, Josephine H. Naish, John C. Waterton, Per Wollmer, Sandra Diaz, Marita Olsson, et al.

    Interest in using T1 as a potential MRI biomarker of chronic obstructive pulmonary disease (COPD) has recently increased. Since tobacco smoking is the major risk factor for development of COPD, the aim for this study was to examine whether tobacco smoking, pack-years (PY), influenced T1 of the lung parenchyma in asymptomatic current smokers. Lung T1 measurements from 35 subjects, 23 never smokers and 12 current smokers were retrospectively analyzed from an institutional review board approved study. All 35 subjects underwent pulmonary function test (PFT) measurements and lung T1, with similar T1 measurement protocols. A backward linear model of T1 as a function of FEV1, FVC, weight, height, age and PY was tested. A significant correlation between lung T1 and PY was found with a negative slope of -3.2 ms/year (95% confidence interval [CI] [-5.8, -0.6], p = 0.02), when adjusted for age and height. Lung T1 shortens with ageing among all subjects, -4.0 ms/year (95%CI [-6.3, -1.7], p = 0.001), and among the never smokers, -3.7 ms/year (95%CI [-6.0, -1.3], p = 0.003). A correlation between lung T1 and PY when adjusted for both age and height was found, and T1 of the lung shortens with ageing. Accordingly, PY and age can be significant confounding factors when T1 is used as a biomarker in lung MRI studies that must be taken into account to detect underlying patterns of disease.


  • Technical Note: Method to correlate whole‐specimen histopathology of radical prostatectomy with diagnostic MR imaging

    by Deirdre M. McGrath, Jenny Lee, Warren D. Foltz, Navid Samavati, Michael A. S. Jewett, Theo van der Kwast, Peter Chung, Cynthia Ménard, Kristy K. Brock

    Purpose: Validation of MRI‐guided tumor boundary delineation for targeted prostate cancer therapy is achieved via correlation with gold‐standard histopathology of radical prostatectomy specimens. Challenges to accurate correlation include matching the pathology sectioning plane with the in vivo imaging slice plane and correction for the deformation that occurs between in vivo imaging and histology. A methodology is presented for matching of the histological sectioning angle and position to the in vivo imaging slices.Methods: Patients (n = 4) with biochemical failure following external beam radiotherapy underwent diagnostic MRI to confirm localized recurrence of prostate cancer, followed by salvage radical prostatectomy. High‐resolution 3‐D MRI of the ex vivo specimens was acquired to determine the pathology sectioning angle that best matched the in vivo imaging slice plane, using matching anatomical features and implanted fiducials. A novel sectioning device was developed to guide sectioning at the correct angle, and to assist the insertion of reference dye marks to aid in histopathology reconstruction.Results: The percentage difference in the positioning of the urethra in the ex vivo pathology sections compared to the positioning in in vivo images was reduced from 34% to 7% through slicing at the best match angle. Reference dye marks were generated, which were visible in ex vivo imaging, in the tissue sections before and after processing, and in histology sections.Conclusions: The method achieved an almost fivefold reduction in the slice‐matching error and is readily implementable in combination with standard MRI technology. The technique will be employed to generate datasets for correlation of whole‐specimen prostate histopathology with in vivo diagnostic MRI using 3‐D deformable registration, allowing assessment of the sensitivity and specificity of MRI parameters for prostate cancer. Although developed specifically for prostate, the method is readily adaptable to other types of whole tissue specimen, such as mastectomy or liver resection.


  • Magnetic resonance elastography of the brain: An in silico study to determine the influence of cranial anatomy

    by Deirdre M. McGrath, Nishant Ravikumar, Iain D. Wilkinson, Alejandro F. Frangi, Zeike A. Taylor

    Purpose Magnetic resonance elastography (MRE) of the brain has demonstrated potential as a biomarker of neurodegenerative disease such as dementia but requires further evaluation. Cranial anatomical features such as the falx cerebri and tentorium cerebelli membranes may influence MRE measurements through wave reflection and interference and tissue heterogeneity at their boundaries. We sought to determine the influence of these effects via simulation. Methods MRE-associated mechanical stimulation of the brain was simulated using steady state harmonic finite element analysis. Simulations of geometrical models and anthropomorphic brain models derived from anatomical MRI data of healthy individuals were compared. Constitutive parameters were taken from MRE measurements for healthy brain. Viscoelastic moduli were reconstructed from the simulated displacement fields and compared with ground truth. Results Interference patterns from reflections and heterogeneity resulted in artifacts in the reconstructions of viscoelastic moduli. Artifacts typically occurred in the vicinity of boundaries between different tissues within the cranium, with a magnitude of 10%–20%. Conclusion Given that MRE studies for neurodegenerative disease have reported only marginal variations in brain elasticity between controls and patients (e.g., 7% for Alzheimer's disease), the predicted errors are a potential confound to the development of MRE as a biomarker of dementia and other neurodegenerative diseases. Magn Reson Med, 2015.


  • Effect of material property heterogeneity on biomechanical modeling of prostate under deformation

    by Navid Samavati, Deirdre M McGrath, Michael A S Jewett, Theo van der Kwast, Cynthia Ménard, Kristy K Brock

    Biomechanical model based deformable image registration has been widely used to account for prostate deformation in various medical imaging procedures. Biomechanical material properties are important components of a biomechanical model. In this study, the effect of incorporating tumor-specific material properties in the prostate biomechanical model was investigated to provide insight into the potential impact of material heterogeneity on the prostate deformation calculations. First, a simple spherical prostate and tumor model was used to analytically describe the deformations and demonstrate the fundamental effect of changes in the tumor volume and stiffness in the modeled deformation. Next, using a clinical prostate model, a parametric approach was used to describe the variations in the heterogeneous prostate model by changing tumor volume, stiffness, and location, to show the differences in the modeled deformation between heterogeneous and homogeneous prostate models. Finally, five clinical prostatectomy examples were used in separately performed homogeneous and heterogeneous biomechanical model based registrations to describe the deformations between 3D reconstructed histopathology images and ex vivo magnetic resonance imaging, and examine the potential clinical impact of modeling biomechanical heterogeneity of the prostate. The analytical formulation showed that increasing the tumor volume and stiffness could significantly increase the impact of the heterogeneous prostate model in the calculated displacement differences compared to the homogeneous model. The parametric approach using a single prostate model indicated up to 4.8 mm of displacement difference at the tumor boundary compared to a homogeneous model. Such differences in the deformation of the prostate could be potentially clinically significant given the voxel size of the ex vivo MR images (0.3 × 0.3 × 0.3 mm). However, no significant changes in the registration accuracy were observed using heterogeneous models for the limited number of clinical prostatectomy patients modeled and evaluated in this study.


  • Feasibility assessment of using oxygen-enhanced magnetic resonance imaging for evaluating the effect of pharmacological treatment in COPD

    by Alexandra R. Morgan, Geoff J.M. Parker, Caleb Roberts, Giovanni A. Buonaccorsi, Niall C. Maguire, Penny L. Hubbard Cristinacce, Dave Singh, Jørgen Vestbo, Leif Bjermer, Jonas Jögi, et al.


  • SU-E-J-95: Towards Optimum Boundary Conditions for Biomechanical Model Based Deformable Registration Using Intensity Based Image Matching for Prostate Correlative Pathology

    by N Samavati, D.M. McGrath, J Lee, T van der Kwast, M Jewett, C Mã©Nard, J.P.W. Pluim, K.K. Brock


  • Open Access

    Biomechanical model-based deformable registration of MRI and histopathology for clinical prostatectomy

    by Navid Samavati, Deirdre M. McGrath, Jenny Lee, Theodorus van der Kwast, Michael Jewett, Cynthia Ménard, Kristy K. Brock