ARAleksandar Ranković

Aleksandar Ranković

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Aleksandar Ranković has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Multiplier-Free, Electronically Tunable Floating Memtranstor Emulator for Neuromorphic and Artificial Synaptic Applications

    by Predrag Petrović, Vladica Mijailović, Aleksandar Ranković

    This paper presents a compact floating memtranstor (MT) emulator, a memory element characterized by a direct φ–q relationship, realized without analog multipliers or complex circuitry. The proposed design employs only two active blocks—a voltage differential transconductance amplifier (VDTA) and a voltage differential current conveyor (VDCC)—along with three grounded capacitors and a single grounded electronically tunable resistor. The emulator accurately reproduces the fundamental φ–q dynamics, exhibiting origin-crossing pinched hysteresis loops under sinusoidal excitation, and operates at a low supply voltage of ±0.9 V. Electronic tunability is achieved via bias-controlled transconductance modulation, enabling flexible adaptation across excitation frequencies and operating conditions. Validation is performed through analytical modeling, Monte Carlo simulations, temperature sensitivity analysis, and full LTspice post-layout simulations using a 180 nm CMOS process. The full-custom layout occupies 2529.49 μm2, with robust performance confirmed under parasitic and process variations. Adaptive learning simulations demonstrate the emulator’s artificial synaptic plasticity, highlighting its suitability for neuromorphic computing, chaos-based circuits, and nonlinear dynamical systems. The compact, low-power, and multiplier-free architecture establishes the proposed MT emulator as a practical platform for emerging analog memory-centric applications. To validate the feasibility of the proposed solution, experimental tests are performed using commercially available components.


  • Calculation of Switching Overvoltage for the Case of a Bolted Three-Phase Short Circuit on a Medium-Voltage Feeder with Connected Induction and/or Synchronous Generators

    by Vladica Mijailović, Aleksandar Ranković

    This paper presents a procedure for calculating switching overvoltage on the main circuit breaker of a medium-voltage (MV) cable feeder, to which induction and/or synchronous generators are connected, during a three-phase short circuit. When a fault occurs, the feeder is disconnected by the circuit breaker located at its beginning. After the set operating time of the relay protection, since islanded operation is not permitted, the connected distributed generators will also be disconnected. It is shown that, during the period when the network is disconnected while the generators remain connected, the overvoltage factor reaches values between 2.2 and 2.5, depending on the types of generators and the location of points of common coupling. The individual transient responses of the distribution network and the mentioned types of distributed generators differ significantly. Using the superposition theorem, the calculation of switching overvoltage is demonstrated with elementary computer assistance.


  • Improvement of Power Output Prediction in Hydroelectric Plants through Cluster Analysis of Data and a Combined Artificial Neural Network Model

    by Stefan Čubonović, Aleksandar Ranković, Marko Krstić

    This research continues previous efforts invested in the application of Artificial Neural Networks (ANN) for predicting the output power of hydroelectric power plants, aiming for further improvements in the accuracy and robustness of the models. The paper focuses on the implementation and evaluation of a combined model that utilizes cluster analysis of water flow through the turbine data with a set threshold and two ANN models: Feedforward Artificial Neural Network (FF-ANN) and Recurrent Neural Network (RNN). Cluster analysis of data with a set threshold, defined based on water flow stability, was applied to select one of the two proposed ANN models. This approach ensured confidence in the model's accuracy and identified specific operational conditions of the hydroelectric power plant. The analysis includes data collected during various hydrological cycles in one year, testing the adaptability of the proposed models. The results of this research promise significant improvements in the efficiency of the previously created model for predicting the power output of hydroelectric power plants.

  • Economic Effects of Measures for Reducing Losses in Electrical Distribution Network within the Transition to a Sustainable Active Distribution System

    by Vladica Mijailović, Aleksandar Ranković

    This paper provides a comprehensive analysis of the economic implications of implementing advanced loss-reduction measures in electrical distribution networks, as observed across developed economies. The study evaluates a set of technical and infrastructural interventions that have demonstrated significant potential in enhancing network efficiency and reducing operational losses. These measures encompass the large-scale deployment of smart electricity meters, the replacement of conventional distribution transformers with units employing amorphous metal cores, and the mitigation of transformer overloading through the installation of higher-rated capacity units. Additional strategies include increasing the cross-sectional area of distribution conductors, optimizing feeder configurations by extending medium-voltage lines, shortening low-voltage feeders, and relocating substations closer to feeder midpoints. Moreover, the paper examines the transition from the conventional “one substation–multiple feeders” configuration toward a more efficient “one substation–one feeder” supply concept. The results of the analysis confirm that the implementation of these measures is both technically and economically justified, yielding substantial improvements in network performance, energy efficiency, and long-term operational sustainability.

  • Unapređenje predikcije snage na izlazu hidroelektrane primenom sezonske segmentacije i SOM-metoda klasterizacije podataka

    by Fakultet Tehničkih Nauka Univerzitet U Kragujevcu, Stefan Čubonović, Aleksandar Ranković

    Ovaj rad predstavlja nastavak prethodnog istraživanja u primeni veštačkih neuronskih mreža (Artificial Neural Networks – ANN) za predikciju snage na izlazu hidroelektrane (HE), korišćenjem dva tipa ANN: veštačke neuronske mreže sa jednosmernim prostiranjem signala (Feedforward Artificial Neural Networks – FF-ANN) i rekurentne neuronske mreže (Recurrent Neural Network – RNN). U novom pristupu povećan je obim podataka za testiranje modela na celu godinu. Godišnji skup podataka podeljen je u četiri sezonske celine po meteorološkom kriterijumu – proleće, leto, jesen i zima – pri čemu je za svaku sezonu razvijen poseban adaptivni model ANN, sa dodatnom podelom podataka na osnovu dinamike protoka. Kako bi se unapredila preciznost segmentacije radnih režima, u radu je takođe primenjena Self-Organizing Map (SOM) neuronska mreža za klasterizaciju podataka, čime je omogućeno bolje prilagođavanje ANN modela različitim uslovima rada. Cilj rada je dodatno unapređenje preciznosti i robusnosti modela kako bi se omogućila bolja prilagodljivost specifičnim hidrološkim i operativnim uslovima svake sezone. Rezultati testiranja pokazuju da sezonski i SOM modeli nadmašuju model treniran na ograničenom periodu, po pitanju preciznosti predviđanja. Na ovaj način doprinosi se poverenju u kreirane modele i otvaraju se mogućnosti za njihovo unapređenje.

  • ECONOMIC EFFECTS OF MEASURES FOR REDUCING LOSSES IN ELECTRICAL DISTRIBUTION NETWORK WITHIN THE TRANSITION TO A SUSTAINABLE ACTIVE DISTRIBUTION SYSTEM

    by Vladica Mijailović, Aleksandar Ranković

    This paper provides an overview of the economic effects of measures that have been implemented to varying degrees in developed countries worldwide, resulting in a significant reduction of losses in the electrical distribution network. The following measures have been analyzed: - Implementation of smart electricity meters, - Replacement of existing distribution transformers with units featuring amorphous cores, - Reducing the loads of distribution transformers by installing units of higher rated power, - Increasing the cross-sectional area of existing conductors, - Shortening low-voltage feeders by increasing the length of the medium-voltage feeders and shifting the supplying substation towards the middle of the feeder, - Change in the configuration from the current "one substation-multiple feeders" power supply concept to the "one substation-one feeder" power supply concept. The results of the performed analyses indicate that the implementation of these measures in our country is absolutely justified.

  • The Application of Artificial Neural Networks for Predicting the Power Output of a Hydroelectric Power Plant

    by Stefan Čubonović, Aleksandar Ranković, Marko Krstić, Public Enterprise „Elektroprivreda Srbije“

    The research paper analysed two types of artificial neural networks (ANN) for predicting the power output of a hydroelectric power plant. The first type is the feedforward artificial neural network (FF-ANN), while the second type is the recurrent neural network (RNN). Authors thoroughly analysed the steps taken in the process of implementing neural networks for this purpose, from data collection and preparation to training, evaluation, and results analysis. The input data includes net head, water flow through the turbine, upper water level, lower water level, and the temperature of the inlet cooling water. Based on the correlation coefficient of individual variables from the input layer with the output power, new ANN implementations were conducted. The results obtained from these variations were systematically analysed to achieve precise modelling, focusing on dynamic changes in water flow through the turbine.


  • REVERSED POWER FLOW IN AN ACTIVE ELECTRICAL DISTRIBUTION NETWORK

    by Vladica Mijailović, Aleksandar Ranković

    Traditional electrical distribution networks are designed with the assumption of a unidirectional power flow, from a higher voltage level network to a lower voltage level network. When distributed generators (DG) are connected to the electrical distribution network, it becomes bidirectionally powered, and the aforementioned assumption no longer holds. DGs significantly influence, among other things, voltage conditions, power flows, and fault currents. The effects of DG on the network can be positive or negative, depending on the type, power, connection point in the network, and the production-consumption ratio at a given location. The paper analyzes the case when DG production exceeds the required consumption in the electrical distribution network, leading to power being fed back into the higher voltage level network, i.e., reversed power flow. A step-by-step calculation example is provided for a MV-feeder where a DG is connected (voltage value at the supply bus and at the DG connection point for a given generated power value), along with a review of foreign experiences on the subject.

  • Open Access

    Impact of the non-Gaussian measurement noise on the performance of state-of-the-art state estimators for distribution systems

    by Stefan Cubonovic, Dragan Cetenovic, Aleksandar Rankovic

    This paper aims to investigate the impact of non-Gaussian measurement noise on state estimation (SE) results in distribution systems. To this end, the measurement noise is assumed to be distributed according to Gaussian or one of the following non-Gaussian probability distribution functions: Uniform, Laplace, Weibull and Gaussian mixture of two Gaussian components. The influence is investigated on three different state-of-the-art SE methods: weighted least squares (WLS) based static SE method, and two Kalman filter based forecasting-aided SE methods, namely extended Kalman filter (EKF) and unscented Kalman filter (UKF). Analyses are conducted on modified IEEE 37-bus system under different operating conditions, including quasi-steady state, sudden state changes and bad data. Performance of the methods in the presence of non-Gaussian measurement noise is compared against their performance when measurement noise is Gaussian distributed. The main conclusions were drawn, summarizing the impacts non-Gaussian measurement noise has on SE and proposing the solutions for overcoming some of the negative impacts.