Kadri Süleyman Yiğit
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kadri Süleyman Yiğit has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Ali Kibar
Department of Mechanical and Material Technologies, Kocaeli University, Uzunciftlik Nuh Cimento Campus, 41180, Kocaeli, Turkey
5 shared publications - Ogan Karabaş
Department of Mechanical Engineering, Faculty of Engineering, Kocaeli University, Türkiye
3 shared publications - Ismail Hakki Savci
Ford Otosan
2 shared publications - Sevgi Aydın
Kocaeli University
2 shared publications - Zafer Doğruyol
Altan Hydraulic Engineering Industry and Trade Corporation, Istanbul, 34956, Turkey
2 shared publications - Abdülvehhab Kazdaloğlu
Department of Electrical Engineering, Faculty of Engineering, Kocaeli University, Türkiye
1 shared publication
Latest Publications
- 27 July 2026
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
- Vol. 240 (22) , 9509-9533
Comparative performance analysis for solar tracking systems in mid-latitude climates: Insights from a one-year experimental study
Fixed-tilt photovoltaic (PV) systems suffer from cosine losses, especially at low solar angles during morning and evening, because they cannot track the Sun’s daily and seasonal motion. This leads to optical misalignment and reduced efficiency in mid-latitude regions such as Türkiye. Although single-axis tracking systems address this issue, field-validated data on their year-long performance under real industrial conditions remain limited. This study presents a 1-year experimental comparison between fixed-tilt and single-axis tracking PV systems operating in Kocaeli, Türkiye (40°49′20.61″ N, 29°55′23.98″ E). Two identical 2.7 kWp grid-tied arrays were monitored at 5-min intervals from September 2024 to August 2025. The single-axis tracker employed an astronomical, time-based control algorithm to maintain favorable panel orientation throughout the day. The results show an annual energy gain of 28.7%, with monthly improvements reaching 38% during the summer. Winter performance was more site- and condition-dependent: under typical snow-free conditions, the realized gain was lower than in summer and strongly influenced by the direct-to-diffuse irradiance balance. In addition, a snow-shedding event highlighted an operational advantage of the tracker under specific winter conditions, but this event should not be interpreted as a universally representative winter-gain benchmark. From an economic perspective, the tracking system achieved a 12.2% lower Levelized Cost of Energy ($ 0.036/kWh) and a shorter payback period (2.25 years) than that of the fixed-tilt system (2.65 years). Therefore, these findings demonstrate the practical benefit of single-axis tracking under the current industrial rooftop conditions; however, the magnitude of the benefit depends on local climate, inverter sizing, snow behavior, and installation alignment.
- 27 July 2026
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
- Vol. 240 (22) , 9509-9533
Comparative performance analysis for solar tracking systems in mid-latitude climates: Insights from a one-year experimental study
Fixed-tilt photovoltaic (PV) systems suffer from cosine losses, especially at low solar angles during morning and evening, because they cannot track the Sun’s daily and seasonal motion. This leads to optical misalignment and reduced efficiency in mid-latitude regions such as Türkiye. Although single-axis tracking systems address this issue, field-validated data on their year-long performance under real industrial conditions remain limited. This study presents a 1-year experimental comparison between fixed-tilt and single-axis tracking PV systems operating in Kocaeli, Türkiye (40°49′20.61″ N, 29°55′23.98″ E). Two identical 2.7 kWp grid-tied arrays were monitored at 5-min intervals from September 2024 to August 2025. The single-axis tracker employed an astronomical, time-based control algorithm to maintain favorable panel orientation throughout the day. The results show an annual energy gain of 28.7%, with monthly improvements reaching 38% during the summer. Winter performance was more site- and condition-dependent: under typical snow-free conditions, the realized gain was lower than in summer and strongly influenced by the direct-to-diffuse irradiance balance. In addition, a snow-shedding event highlighted an operational advantage of the tracker under specific winter conditions, but this event should not be interpreted as a universally representative winter-gain benchmark. From an economic perspective, the tracking system achieved a 12.2% lower Levelized Cost of Energy ($ 0.036/kWh) and a shorter payback period (2.25 years) than that of the fixed-tilt system (2.65 years). Therefore, these findings demonstrate the practical benefit of single-axis tracking under the current industrial rooftop conditions; however, the magnitude of the benefit depends on local climate, inverter sizing, snow behavior, and installation alignment.
- 1 July 2026
- Published by Academic World Research in Journal of Applied Fluid Mechanics
- Vol. 19 (7)
Experimental and Numerical Investigation of a Dynamic Function Vehicle Tire Air Control Valve
The Central Tire Inflation System (CTIS) is increasingly adopted in buses, trucks, and military vehicles, as it enables adaptive tire pressure control under varying terrain conditions, thereby improving vehicle performance and safety. In defense applications, the use of electronic components within tire systems is prohibited, which necessitates fully mechanical valve designs operating on alternative physical principles. This study presents an experimental and numerical investigation of a dynamic-function vehicle tire air control valve developed by Altan Hydraulic. Experimental results show that the original valve configuration cannot reliably remain open at low airflow rates (≤135 L/min). To overcome this limitation, a vacuum-assisted operating mechanism was investigated. Region A denotes the vacuum chamber, Region B the high-pressure chamber generating the opening force on the spool, and Region C the main flow passage. The nozzle tip inclination angle was modified from its original value of α = 90° in 10° increments over a range of 40°–180°, and the Ø0.2 mm orifice was repositioned to align with regions of maximum flow velocity, limiting the mass flow entering Region A. Flow dynamics and spool force balances were analyzed for Reynolds numbers between 33,874 and 112,913. The redesigned configuration generated a vacuum pressure of approximately −35 kPa in Region A at α = 120°, enabling the valve to remain open at tire pressures as low as 30 kPa. The results demonstrate that pressurized air from the tire can be used to generate a self-induced vacuum, ensuring sustained valve opening without electronic components. The proposed fully mechanical design significantly enhances CTIS performance by providing a reliable and energy-efficient solution for military and off-road vehicles.
- 1 July 2026
- Published by Academic World Research in Journal of Applied Fluid Mechanics
- Vol. 19 (7)
Experimental and Numerical Investigation of a Dynamic Function Vehicle Tire Air Control Valve
The Central Tire Inflation System (CTIS) is increasingly adopted in buses, trucks, and military vehicles, as it enables adaptive tire pressure control under varying terrain conditions, thereby improving vehicle performance and safety. In defense applications, the use of electronic components within tire systems is prohibited, which necessitates fully mechanical valve designs operating on alternative physical principles. This study presents an experimental and numerical investigation of a dynamic-function vehicle tire air control valve developed by Altan Hydraulic. Experimental results show that the original valve configuration cannot reliably remain open at low airflow rates (≤135 L/min). To overcome this limitation, a vacuum-assisted operating mechanism was investigated. Region A denotes the vacuum chamber, Region B the high-pressure chamber generating the opening force on the spool, and Region C the main flow passage. The nozzle tip inclination angle was modified from its original value of α = 90° in 10° increments over a range of 40°–180°, and the Ø0.2 mm orifice was repositioned to align with regions of maximum flow velocity, limiting the mass flow entering Region A. Flow dynamics and spool force balances were analyzed for Reynolds numbers between 33,874 and 112,913. The redesigned configuration generated a vacuum pressure of approximately −35 kPa in Region A at α = 120°, enabling the valve to remain open at tire pressures as low as 30 kPa. The results demonstrate that pressurized air from the tire can be used to generate a self-induced vacuum, ensuring sustained valve opening without electronic components. The proposed fully mechanical design significantly enhances CTIS performance by providing a reliable and energy-efficient solution for military and off-road vehicles.
- Open Access
- 31 December 2025
- Published by Hitit University in Hittite Journal of Science and Engineering
- Vol. 12 (4) , 209-221
Thermal Runaway in Lithium-Ion Batteries: Modeling, Experimental Validation, and Material Effects on Propagation
The thermal safety of lithium-ion batteries (LIBs) is a crucial challenge for electric vehicles and stationary energy storage systems, as excessive heat generation may cause accelerated aging, capacity loss, or catastrophic thermal runaway (TR). This study develops and validates a coupled electrochemical–thermal model to investigate the heat generation, temperature response, and TR behavior of cylindrical 18650-type LIBs. Experimental discharge tests (1C and 2C) were performed on a 1S14P battery module, and the results were compared with numerical simulations in STAR-CCM+ and an Arrhenius-based TR model implemented in MATLAB Simulink. The model accurately captured the onset of exothermic reactions, with a maximum deviation of ~5% from experimental data. Parametric analyses revealed that higher ambient convection coefficients delay TR initiation and reduce its severity, highlighting the importance of forced-air cooling in thermal management systems. Furthermore, the effect of different enclosure materials on TR propagation was investigated. While ceramic fiber and aerogel provided the most effective thermal insulation, polystyrene demonstrated the best overall balance between heat dissipation under normal operation and insulation during TR events. The findings confirm that material selection and thermal management design play a decisive role in preventing TR propagation and ensuring battery safety. This work contributes practical guidelines for the safe and efficient design of next-generation battery systems.
- 31 December 2025
- Published by Hitit University in Hittite Journal of Science and Engineering
- Vol. 12 (4) , 209-221
Open AccessThermal Runaway in Lithium-Ion Batteries: Modeling, Experimental Validation, and Material Effects on Propagation
The thermal safety of lithium-ion batteries (LIBs) is a crucial challenge for electric vehicles and stationary energy storage systems, as excessive heat generation may cause accelerated aging, capacity loss, or catastrophic thermal runaway (TR). This study develops and validates a coupled electrochemical–thermal model to investigate the heat generation, temperature response, and TR behavior of cylindrical 18650-type LIBs. Experimental discharge tests (1C and 2C) were performed on a 1S14P battery module, and the results were compared with numerical simulations in STAR-CCM+ and an Arrhenius-based TR model implemented in MATLAB Simulink. The model accurately captured the onset of exothermic reactions, with a maximum deviation of ~5% from experimental data. Parametric analyses revealed that higher ambient convection coefficients delay TR initiation and reduce its severity, highlighting the importance of forced-air cooling in thermal management systems. Furthermore, the effect of different enclosure materials on TR propagation was investigated. While ceramic fiber and aerogel provided the most effective thermal insulation, polystyrene demonstrated the best overall balance between heat dissipation under normal operation and insulation during TR events. The findings confirm that material selection and thermal management design play a decisive role in preventing TR propagation and ensuring battery safety. This work contributes practical guidelines for the safe and efficient design of next-generation battery systems.
- Open Access
Experimental and Numerical Investigation of Heat Transfer Performance for All Water Inlet and Outlet Configurations in a Panel Radiator
In a modern-day household, the most significant part of energy consumption is space heating. In this study, the effects of connection configurations on the heat transfer from the radiator are investigated. The difference between the current study and previous studies is that all possible valve connection configurations are investigated on the radiator, instead of only having water enter through one valve and outlet through another. The experimental results of heat transfer from the radiator in all connection configurations are presented. In addition, the temperature distributions on the radiator surface for each connection configuration are visualized using a thermal camera, and remarkable findings are presented. These images provide insights into the water flow distribution in the ducts of the radiator and the effects of the distribution on heat transfer. CFD simulations were conducted to analyze temperature and flow distributions for different connection configurations and revealed that two inlets from the bottom and two outlets from the top of the panel radiator have the best case in terms of temperature distribution. This study contributes to improving energy consumption efficiency for space heating by determining the heat transfer rate from the radiator in different valve connection configurations.
Open AccessExperimental and Numerical Investigation of Heat Transfer Performance for All Water Inlet and Outlet Configurations in a Panel Radiator
In a modern-day household, the most significant part of energy consumption is space heating. In this study, the effects of connection configurations on the heat transfer from the radiator are investigated. The difference between the current study and previous studies is that all possible valve connection configurations are investigated on the radiator, instead of only having water enter through one valve and outlet through another. The experimental results of heat transfer from the radiator in all connection configurations are presented. In addition, the temperature distributions on the radiator surface for each connection configuration are visualized using a thermal camera, and remarkable findings are presented. These images provide insights into the water flow distribution in the ducts of the radiator and the effects of the distribution on heat transfer. CFD simulations were conducted to analyze temperature and flow distributions for different connection configurations and revealed that two inlets from the bottom and two outlets from the top of the panel radiator have the best case in terms of temperature distribution. This study contributes to improving energy consumption efficiency for space heating by determining the heat transfer rate from the radiator in different valve connection configurations.
- 21 October 2025
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 107
Experimental investigation and theoretical modeling of a dynamic function vehicle tire air control valve
- 21 October 2025
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 107
Experimental investigation and theoretical modeling of a dynamic function vehicle tire air control valve
- Open Access
Impact of Cooling Strategies and Cell Housing Materials on Lithium-Ion Battery Thermal Management Performance
The transition to renewable energy sources from fossil fuels requires that the harvested energy be stored because of the intermittent nature of renewable sources. Thus, lithium-ion batteries have become a widely utilized power source in both daily life and industrial applications due to their high power output and long lifetime. In order to ensure the safe operation of these batteries at their desired power and capacities, it is crucial to implement a thermal management system (TMS) that effectively controls battery temperature. In this study, the thermal performance of a 1S14P lithium-ion battery module composed of cylindrical 18650 cells was compared for distinct cases of natural convection (no cooling), forced air convection, and phase change material (PCM) cooling. During the tests, the greatest temperatures were reached at a 2C discharge rate; the maximum module temperature reached was 55.4 °C under the natural convection condition, whereas forced air convection and PCM cooling reduced the maximum module temperature to 46.1 °C and 52.3 °C, respectively. In addition, contacting the battery module with an aluminum mass without using an active cooling element reduced the temperature to 53.4 °C. The polyamide battery housing (holder) used in the module limited the cooling performance. Thus, simulations on alternative materials document how the cooling efficiency can be increased.
Open AccessImpact of Cooling Strategies and Cell Housing Materials on Lithium-Ion Battery Thermal Management Performance
The transition to renewable energy sources from fossil fuels requires that the harvested energy be stored because of the intermittent nature of renewable sources. Thus, lithium-ion batteries have become a widely utilized power source in both daily life and industrial applications due to their high power output and long lifetime. In order to ensure the safe operation of these batteries at their desired power and capacities, it is crucial to implement a thermal management system (TMS) that effectively controls battery temperature. In this study, the thermal performance of a 1S14P lithium-ion battery module composed of cylindrical 18650 cells was compared for distinct cases of natural convection (no cooling), forced air convection, and phase change material (PCM) cooling. During the tests, the greatest temperatures were reached at a 2C discharge rate; the maximum module temperature reached was 55.4 °C under the natural convection condition, whereas forced air convection and PCM cooling reduced the maximum module temperature to 46.1 °C and 52.3 °C, respectively. In addition, contacting the battery module with an aluminum mass without using an active cooling element reduced the temperature to 53.4 °C. The polyamide battery housing (holder) used in the module limited the cooling performance. Thus, simulations on alternative materials document how the cooling efficiency can be increased.
- 14 February 2025
- Published by Springer Nature in Journal of the Brazilian Society of Mechanical Sciences and Engineering
- Vol. 47 (3) , 1-17
Examination of flow in the monoblock directional valve: from pump to tank
- 14 February 2025
- Published by Springer Nature in Journal of the Brazilian Society of Mechanical Sciences and Engineering
- Vol. 47 (3) , 1-17
Examination of flow in the monoblock directional valve: from pump to tank
- Open Access
- 30 September 2024
- Published by International Journal of Automotive Science and Technology in International Journal of Automotive Science And Technology
- Vol. 8 (3) , 303-311
Numerical Investigation of the Fuel Tank Sloshing Condition of a Commercial Vehicle
This study investigates the impact of baffles on fuel sloshing behavior within truck fuel tanks using numerical simulations. The volume of the fluid multiphase model is employed to analyze the flow dynamics of 25% diesel fuel in a 250 L tank, modeled in a 3D domain. Two configurations were compared: a tank with baffles and one without. The primary focus is to analyze fuel distribution within the intake port region during vehicle acceleration and deceleration maneuvers. The simulated scenario mimics a realistic driving situation. The vehicle accelerates from 0 km/h to 60 km/h over 10 s, followed by a 3-s braking period to reach a complete stop (0 km/h) at the 13-s mark. The simulation then observes the fuel behavior within the tank for an addi-tional 7 s while the vehicle remains stationary. Results reveal significant differences in fuel behavior between baffled and unbaffled tanks. In the absence of baffles, the sloshing motion is substantial, leading to a complete depletion of fuel in the intake port region for a duration of 3 s during both the acceleration and deceleration phases (between 10 and 13 s). Compared to a standard tank, the presence of baffles significantly reduced the sloshing amplitude by approximately 70%. Furthermore, baffles led to a 50% decrease in pressure variations on the tank walls. Temporary fuel starvation can negatively impact engine performance and combustion efficiency. Conversely, the presence of baffles within the tank effectively mitigates sloshing and ensures continuous fuel presence at the intake port the entire simulation. This suggests that baffles play a crucial role in maintaining a stable and consistent fuel supply to the engine, even during dynamic vehicle maneuvers.
- 30 September 2024
- Published by International Journal of Automotive Science and Technology in International Journal of Automotive Science And Technology
- Vol. 8 (3) , 303-311
Open AccessNumerical Investigation of the Fuel Tank Sloshing Condition of a Commercial Vehicle
This study investigates the impact of baffles on fuel sloshing behavior within truck fuel tanks using numerical simulations. The volume of the fluid multiphase model is employed to analyze the flow dynamics of 25% diesel fuel in a 250 L tank, modeled in a 3D domain. Two configurations were compared: a tank with baffles and one without. The primary focus is to analyze fuel distribution within the intake port region during vehicle acceleration and deceleration maneuvers. The simulated scenario mimics a realistic driving situation. The vehicle accelerates from 0 km/h to 60 km/h over 10 s, followed by a 3-s braking period to reach a complete stop (0 km/h) at the 13-s mark. The simulation then observes the fuel behavior within the tank for an addi-tional 7 s while the vehicle remains stationary. Results reveal significant differences in fuel behavior between baffled and unbaffled tanks. In the absence of baffles, the sloshing motion is substantial, leading to a complete depletion of fuel in the intake port region for a duration of 3 s during both the acceleration and deceleration phases (between 10 and 13 s). Compared to a standard tank, the presence of baffles significantly reduced the sloshing amplitude by approximately 70%. Furthermore, baffles led to a 50% decrease in pressure variations on the tank walls. Temporary fuel starvation can negatively impact engine performance and combustion efficiency. Conversely, the presence of baffles within the tank effectively mitigates sloshing and ensures continuous fuel presence at the intake port the entire simulation. This suggests that baffles play a crucial role in maintaining a stable and consistent fuel supply to the engine, even during dynamic vehicle maneuvers.
- Open Access
- 30 June 2024
- Published by Hitit University in Hittite Journal of Science and Engineering
- Vol. 11 (2) , 69-75
Analysis of the Effects of Infusion Drips on Flow Rate and Volume Determination in IV Systems
In this study, drop form flow examinations, which form the basis of IV applications used for therapeutic purposes, were performed. Fluid Intravenous (IV) is the practice of administering fluids into a vein. In IV applications, flow must be monitored in order to follow and control the treatment process. For this purpose, the fluid can be converted into drop form with a simple mechanism and the flow rate and volume data can be calculated by the drop counting method. Examining drop form flow processes and analyzing microdrops correctly increases the accuracy in calculating flow data and, most importantly, increases the quality of treatment in IV applications. In the scope of this study, the formation processes of microdrops and the affecting parameters were analyzed. Along with microdrop analysis, error evaluation of the drop counting method and evaluation of measurement techniques were carried out to ensure a healthy and accurate measurement process. System tests and verification were carried out with optical systems, one of the measurement techniques. As a result, this study was carried out on the importance of monitoring systems and measurement parameters in IV applications.
- 30 June 2024
- Published by Hitit University in Hittite Journal of Science and Engineering
- Vol. 11 (2) , 69-75
Open AccessAnalysis of the Effects of Infusion Drips on Flow Rate and Volume Determination in IV Systems
In this study, drop form flow examinations, which form the basis of IV applications used for therapeutic purposes, were performed. Fluid Intravenous (IV) is the practice of administering fluids into a vein. In IV applications, flow must be monitored in order to follow and control the treatment process. For this purpose, the fluid can be converted into drop form with a simple mechanism and the flow rate and volume data can be calculated by the drop counting method. Examining drop form flow processes and analyzing microdrops correctly increases the accuracy in calculating flow data and, most importantly, increases the quality of treatment in IV applications. In the scope of this study, the formation processes of microdrops and the affecting parameters were analyzed. Along with microdrop analysis, error evaluation of the drop counting method and evaluation of measurement techniques were carried out to ensure a healthy and accurate measurement process. System tests and verification were carried out with optical systems, one of the measurement techniques. As a result, this study was carried out on the importance of monitoring systems and measurement parameters in IV applications.
- 31 December 2021
- Published by Springer Nature in Sādhanā
- Vol. 47 (1) , 1-12
Investigation of a cross-flow turbine under natural conditions
- 31 December 2021
- Published by Springer Nature in Sādhanā
- Vol. 47 (1) , 1-12
Investigation of a cross-flow turbine under natural conditions