Ismail Hakki Savci
Research Subjects
Ismail Hakki Savci has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Abdurrahman Yilmaz
Department of Control and Automation Engineering, Istanbul Technical University, Istanbul 34485, Türkiye
2 shared publications - Burak Yelken
KOCAELİ ÜNİVERSİTESİ, MÜHENDİSLİK FAKÜLTESİ, MAKİNE MÜHENDİSLİĞİ BÖLÜMÜ
2 shared publications - Hakan Ocakli
Sancaktepe R& D Center, Ford Otomotiv Sanayi Inc, Istanbul, Turkey
2 shared publications - Hakan Temeltas
Department of Control and Automation Engineering, Istanbul Technical University, Maslak, İstanbul, Trkiye
2 shared publications Hande Bezci Zeren
Ford Otosan Company, Product Development Department, 34885 Istanbul, Turkey
2 shared publications- Kadri Süleyman Yiğit
Department of Mechanical Engineering, Kocaeli University, Kocaeli, Turkey
2 shared publications
Latest Publications
- Open Access
- 31 December 2025
- Published by Hitit University in Hittite Journal of Science and Engineering
- Vol. 12 (4) , 209-221
Thermal Runaway in Lithium-Ion Batteries: Modeling, Experimental Validation, and Material Effects on Propagation
The thermal safety of lithium-ion batteries (LIBs) is a crucial challenge for electric vehicles and stationary energy storage systems, as excessive heat generation may cause accelerated aging, capacity loss, or catastrophic thermal runaway (TR). This study develops and validates a coupled electrochemical–thermal model to investigate the heat generation, temperature response, and TR behavior of cylindrical 18650-type LIBs. Experimental discharge tests (1C and 2C) were performed on a 1S14P battery module, and the results were compared with numerical simulations in STAR-CCM+ and an Arrhenius-based TR model implemented in MATLAB Simulink. The model accurately captured the onset of exothermic reactions, with a maximum deviation of ~5% from experimental data. Parametric analyses revealed that higher ambient convection coefficients delay TR initiation and reduce its severity, highlighting the importance of forced-air cooling in thermal management systems. Furthermore, the effect of different enclosure materials on TR propagation was investigated. While ceramic fiber and aerogel provided the most effective thermal insulation, polystyrene demonstrated the best overall balance between heat dissipation under normal operation and insulation during TR events. The findings confirm that material selection and thermal management design play a decisive role in preventing TR propagation and ensuring battery safety. This work contributes practical guidelines for the safe and efficient design of next-generation battery systems.
- 31 December 2025
- Published by Hitit University in Hittite Journal of Science and Engineering
- Vol. 12 (4) , 209-221
Open AccessThermal Runaway in Lithium-Ion Batteries: Modeling, Experimental Validation, and Material Effects on Propagation
The thermal safety of lithium-ion batteries (LIBs) is a crucial challenge for electric vehicles and stationary energy storage systems, as excessive heat generation may cause accelerated aging, capacity loss, or catastrophic thermal runaway (TR). This study develops and validates a coupled electrochemical–thermal model to investigate the heat generation, temperature response, and TR behavior of cylindrical 18650-type LIBs. Experimental discharge tests (1C and 2C) were performed on a 1S14P battery module, and the results were compared with numerical simulations in STAR-CCM+ and an Arrhenius-based TR model implemented in MATLAB Simulink. The model accurately captured the onset of exothermic reactions, with a maximum deviation of ~5% from experimental data. Parametric analyses revealed that higher ambient convection coefficients delay TR initiation and reduce its severity, highlighting the importance of forced-air cooling in thermal management systems. Furthermore, the effect of different enclosure materials on TR propagation was investigated. While ceramic fiber and aerogel provided the most effective thermal insulation, polystyrene demonstrated the best overall balance between heat dissipation under normal operation and insulation during TR events. The findings confirm that material selection and thermal management design play a decisive role in preventing TR propagation and ensuring battery safety. This work contributes practical guidelines for the safe and efficient design of next-generation battery systems.
- Open Access
Impact of Cooling Strategies and Cell Housing Materials on Lithium-Ion Battery Thermal Management Performance
The transition to renewable energy sources from fossil fuels requires that the harvested energy be stored because of the intermittent nature of renewable sources. Thus, lithium-ion batteries have become a widely utilized power source in both daily life and industrial applications due to their high power output and long lifetime. In order to ensure the safe operation of these batteries at their desired power and capacities, it is crucial to implement a thermal management system (TMS) that effectively controls battery temperature. In this study, the thermal performance of a 1S14P lithium-ion battery module composed of cylindrical 18650 cells was compared for distinct cases of natural convection (no cooling), forced air convection, and phase change material (PCM) cooling. During the tests, the greatest temperatures were reached at a 2C discharge rate; the maximum module temperature reached was 55.4 °C under the natural convection condition, whereas forced air convection and PCM cooling reduced the maximum module temperature to 46.1 °C and 52.3 °C, respectively. In addition, contacting the battery module with an aluminum mass without using an active cooling element reduced the temperature to 53.4 °C. The polyamide battery housing (holder) used in the module limited the cooling performance. Thus, simulations on alternative materials document how the cooling efficiency can be increased.
Open AccessImpact of Cooling Strategies and Cell Housing Materials on Lithium-Ion Battery Thermal Management Performance
The transition to renewable energy sources from fossil fuels requires that the harvested energy be stored because of the intermittent nature of renewable sources. Thus, lithium-ion batteries have become a widely utilized power source in both daily life and industrial applications due to their high power output and long lifetime. In order to ensure the safe operation of these batteries at their desired power and capacities, it is crucial to implement a thermal management system (TMS) that effectively controls battery temperature. In this study, the thermal performance of a 1S14P lithium-ion battery module composed of cylindrical 18650 cells was compared for distinct cases of natural convection (no cooling), forced air convection, and phase change material (PCM) cooling. During the tests, the greatest temperatures were reached at a 2C discharge rate; the maximum module temperature reached was 55.4 °C under the natural convection condition, whereas forced air convection and PCM cooling reduced the maximum module temperature to 46.1 °C and 52.3 °C, respectively. In addition, contacting the battery module with an aluminum mass without using an active cooling element reduced the temperature to 53.4 °C. The polyamide battery housing (holder) used in the module limited the cooling performance. Thus, simulations on alternative materials document how the cooling efficiency can be increased.
- 31 October 2023
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 129 (7-8) , 1-15
Reference cage architecture for autonomous docking of mobile robots in automotive production systems
- 31 October 2023
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 129 (7-8) , 1-15
Reference cage architecture for autonomous docking of mobile robots in automotive production systems
- Open Access
- 30 April 2023
- Published by Turk Isi Bilimi Ve Teknigi Dernegi in Isı Bilimi ve Tekniği Dergisi
- Vol. 43 (1) , 59-68
ANALYSIS OF THERMAL CRACK FORMATION IN WATER-CHARGED AIR-COOLED HEAT EXCHANGERS FOR HEAVY-DUTY VEHICLES
The non-uniform flow distribution at the inlet severely affects the thermal cycling loading of the water-charged air-cooled (WCAC) systems resulting in crack formation after periods and hence leakage in the internal coolant. WCAC cracks are serious since having crucial effects on performance and durability. The thermal crack can be identified by testing the WCAC for various fatigue boundary conditions. The present study developed a custom thermal fatigue test rig to precisely determine the crack formation's location and cycle time in WCACs. The test rig was designed to reflect the vehicle's situation by simultaneously controlling the air and waterside of the WCAC continuously. Accordingly, the thermal fatigue tests of the WCAC parts were performed through the developed custom thermal fatigue test rig. The formation crack was observed periodically by carrying out tests with different critical cycles on the test rig, and the thermal cycling profile was generated. It was seen that the crack formation in the WCAC can be predicted at the same cycle time and exact location with the developed custom test rig compared to the vehicle tests. Moreover, the total cost, time, and man-hours per test increased by 80 %,75 %, and 60, % respectively, compared to traditional vehicle tests. Subsequently, the modified WCAC design was proposed to prevent non-uniform flow distribution at the inlet of the WCAC. The thermal fatigue tests of the modified WCAC design were performed using the developed test rig for stressful operating conditions. The results showed that the modified WCAC design is more robust to thermal fatigue than the old design. There was no crack formation in the modified WCAC design under various stressful operating conditions.
- 30 April 2023
- Published by Turk Isi Bilimi Ve Teknigi Dernegi in Isı Bilimi ve Tekniği Dergisi
- Vol. 43 (1) , 59-68
Open AccessANALYSIS OF THERMAL CRACK FORMATION IN WATER-CHARGED AIR-COOLED HEAT EXCHANGERS FOR HEAVY-DUTY VEHICLES
The non-uniform flow distribution at the inlet severely affects the thermal cycling loading of the water-charged air-cooled (WCAC) systems resulting in crack formation after periods and hence leakage in the internal coolant. WCAC cracks are serious since having crucial effects on performance and durability. The thermal crack can be identified by testing the WCAC for various fatigue boundary conditions. The present study developed a custom thermal fatigue test rig to precisely determine the crack formation's location and cycle time in WCACs. The test rig was designed to reflect the vehicle's situation by simultaneously controlling the air and waterside of the WCAC continuously. Accordingly, the thermal fatigue tests of the WCAC parts were performed through the developed custom thermal fatigue test rig. The formation crack was observed periodically by carrying out tests with different critical cycles on the test rig, and the thermal cycling profile was generated. It was seen that the crack formation in the WCAC can be predicted at the same cycle time and exact location with the developed custom test rig compared to the vehicle tests. Moreover, the total cost, time, and man-hours per test increased by 80 %,75 %, and 60, % respectively, compared to traditional vehicle tests. Subsequently, the modified WCAC design was proposed to prevent non-uniform flow distribution at the inlet of the WCAC. The thermal fatigue tests of the modified WCAC design were performed using the developed test rig for stressful operating conditions. The results showed that the modified WCAC design is more robust to thermal fatigue than the old design. There was no crack formation in the modified WCAC design under various stressful operating conditions.
- 2 February 2023
- Published by Springer Nature
- p. 227-240
High Fidelity IMU and Wheel Encoder Models for ROS Based AGV Simulations
- 2 February 2023
- Published by Springer Nature
- p. 227-240
High Fidelity IMU and Wheel Encoder Models for ROS Based AGV Simulations
- 1 July 2022
- Published by International Journal of Automotive Engineering and Technologies in International Journal of Automotive Engineering and Technologies
- Vol. 11 (2) , 45-52
Water pump filter removal and filter performance study at heavy commercial vehicle engine
Cooling systems are one of the essential systems for internal combustion engines. They prevent damage to engine parts and extend the engine’s life by removing the high heat generated by the combustion from the engine. These systems vary depending on the engine’s volume, combustion pressure, coolant flow, and types and may differ in light commercial and heavy commercial vehicles. These differences are generally observed in the water pump used, type of refrigerant, filter systems, and pump control mechanisms. The most apparent differences are in the water pump and filter systems. Light commercial vehicles do not have a filtration system, while most of the heavy commercial vehicles have a filtration system. There are many studies in the literature focusing on the performance and durability of the filter systems.In this study, the necessity of the filter system in the cooling systems of heavy commercial vehicles, system filtration performance, and whether it is possible to work without a filter were investigated. A water pump performance test setup was used to simulate the real engine condition. The test was performed at 110°C coolant temperature, 1 barg input pressure, and with 53.195gr contamination. Results of the study showed that removing the filter from the coolant system after the first service shortens the life of the water pump.
- 1 July 2022
- Published by International Journal of Automotive Engineering and Technologies in International Journal of Automotive Engineering and Technologies
- Vol. 11 (2) , 45-52
Water pump filter removal and filter performance study at heavy commercial vehicle engine
Cooling systems are one of the essential systems for internal combustion engines. They prevent damage to engine parts and extend the engine’s life by removing the high heat generated by the combustion from the engine. These systems vary depending on the engine’s volume, combustion pressure, coolant flow, and types and may differ in light commercial and heavy commercial vehicles. These differences are generally observed in the water pump used, type of refrigerant, filter systems, and pump control mechanisms. The most apparent differences are in the water pump and filter systems. Light commercial vehicles do not have a filtration system, while most of the heavy commercial vehicles have a filtration system. There are many studies in the literature focusing on the performance and durability of the filter systems.In this study, the necessity of the filter system in the cooling systems of heavy commercial vehicles, system filtration performance, and whether it is possible to work without a filter were investigated. A water pump performance test setup was used to simulate the real engine condition. The test was performed at 110°C coolant temperature, 1 barg input pressure, and with 53.195gr contamination. Results of the study showed that removing the filter from the coolant system after the first service shortens the life of the water pump.
- 18 June 2022
- Published by Elsevier in Applied Thermal Engineering
- Vol. 214, 118884
Experimental and numerical investigation on the urea-deposit formation at different severities in selective catalytic reduction systems
- 18 June 2022
- Published by Elsevier in Applied Thermal Engineering
- Vol. 214, 118884
Experimental and numerical investigation on the urea-deposit formation at different severities in selective catalytic reduction systems
- 31 May 2022
- Published by Kocaeli Journal of Science and Engineering in Kocaeli Journal of Science and Engineering
- Vol. 5 (1) , 22-30
Two Dimensional and Stereo PIV Comparison for Port Applications
Fuel-air movements in-cylinder are one of the most critical diesel engine parameters to determine engine performance and emission. Swirling movement in the engine combustion chamber is investigated advanced experimental techniques to improve the air intake design. Honeycomb measurement method and PIV (particle image velocimetry) method are used to measure the swirling airflow. The honeycomb measurement method can directly measure the swirl. However, it does not give detail information about the flow field. On the other hand, the PIV technique is one of the non-invasive measurement methods for swirl measurement. PIV can directly measure the velocity vector of the cylinder section. In this study, the honeycomb measurement method was performed to measure the swirl ratio of 13L and 9L engines. The uncertainty analysis was determined for the reliability ratio of the measurement. In addition, PIV measurements are performed to understand the velocity field of the cylinder section. This velocity field gives detailed information about the center of the swirl and the velocity index of the velocity field.
- 31 May 2022
- Published by Kocaeli Journal of Science and Engineering in Kocaeli Journal of Science and Engineering
- Vol. 5 (1) , 22-30
Two Dimensional and Stereo PIV Comparison for Port Applications
Fuel-air movements in-cylinder are one of the most critical diesel engine parameters to determine engine performance and emission. Swirling movement in the engine combustion chamber is investigated advanced experimental techniques to improve the air intake design. Honeycomb measurement method and PIV (particle image velocimetry) method are used to measure the swirling airflow. The honeycomb measurement method can directly measure the swirl. However, it does not give detail information about the flow field. On the other hand, the PIV technique is one of the non-invasive measurement methods for swirl measurement. PIV can directly measure the velocity vector of the cylinder section. In this study, the honeycomb measurement method was performed to measure the swirl ratio of 13L and 9L engines. The uncertainty analysis was determined for the reliability ratio of the measurement. In addition, PIV measurements are performed to understand the velocity field of the cylinder section. This velocity field gives detailed information about the center of the swirl and the velocity index of the velocity field.
- 29 April 2022
- Published by Elsevier in Applied Thermal Engineering
- Vol. 212
Numerical and experimental investigation of heavy-duty EGR cooler thermal performance
- 29 April 2022
- Published by Elsevier in Applied Thermal Engineering
- Vol. 212
Numerical and experimental investigation of heavy-duty EGR cooler thermal performance
- 7 March 2022
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 120 (5-6) , 3647-3668
Improving Navigation Stack of a ROS-Enabled Industrial Autonomous Mobile Robot (AMR) to be Incorporated in a Large-Scale Automotive Production
- 7 March 2022
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 120 (5-6) , 3647-3668
Improving Navigation Stack of a ROS-Enabled Industrial Autonomous Mobile Robot (AMR) to be Incorporated in a Large-Scale Automotive Production