YWYongqing Wang

Yongqing Wang

*This is an algorithmically generated author record based on publicly available information.

Yongqing Wang has a total of 6 co-authors. Here are the top co-authors by number of shared publications:

  • Noam Lior

    Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia, PA 19104-6315

    2 shared publications
  • Tatiana Morosuk

    Institute for Energy Engineering, Technische Universität Berlin, Marchstr. 18, 10587 Berlin, Germany

    2 shared publications
  • Hui Zeng

    Cleaning Combustion and Energy Utilization Research Center of Fujian Province, Fujian Province Key Laboratory of Energy Cleaning Utilization and Development, Jimei University, Xiamen 361021, China, Tel. +86 592 6180597; Fax: +86 592 6183503

    1 shared publication
  • Wensheng Cao

    Jimei University College of Marine Equipment and Mechanical Engineering, Key Laboratory of Ocean Renewable Energy Equipment of Fujian Province, Key Laboratory of Energy Cleaning Utilization and Development of Fujian Province Xiamen 361021 , China

    1 shared publication
  • Wensheng Cao

    Department of Marine Engineering, Xiamen Ocean Vocational College

    1 shared publication
  • Zhilong Xu

    Cleaning Combustion and Energy Utilization Research Center of Fujian Province, Fujian Province Key Laboratory of Energy Cleaning Utilization and Development, Jimei University, Xiamen 361021, China, Tel. +86 592 6180597; Fax: +86 592 6183503

    1 shared publication

Latest Publications

  • Exergetic Efficiency of Reverse Osmosis Desalination Systems: Definitions and Discussions

    by Yongqing Wang, Tatiana Morosuk, Wensheng Cao

    Reverse osmosis (RO) desalination is the dominant desalination technology worldwide. The exergetic efficiency—which is recognized as a true measure from a thermodynamic viewpoint—of RO systems has been addressed by many researchers, but the inconsistencies in existing definitions prevent not only objective evaluation of the exergetic performance of an individual RO system, but also a logical comparison of the results among different systems and studies. Strictly following the thermodynamic and exergoeconomic principles, this study presents general and consistent definitions of exergetic efficiency for RO systems, aiming to promote uniformity in this important criterion. Considering the purpose and parametric features of RO systems, total exergy is decomposed into chemical and physical (mechanical plus thermal) exergies. The exergetic efficiencies of over 50 cases are calculated, and the results from different relationships and studies are compared and discussed. For the first time, the exergetic efficiency of thermally-enhanced RO systems is discussed, and the influence of thermal exergy consumption and the thermal exergy increments of permeate and brine is analyzed. Furthermore, the reasons behind the significant deviations in the results of some studies are revealed, and the defects or even mistakes in some of the existing definitions are pointed out. This work clarifies the definition and improves the understanding of the exergetic efficiency of RO desalination systems.

  • Carbon Footprint of Seawater Desalination Technologies: A Review

    by Yongqing Wang, Tatiana Morosuk, Wensheng Cao

    As an important and effective way of mitigating water shortages, desalination has steadily and rapidly increased its global capacity over the decades. This raises concern about its environmental impacts, especially its carbon footprint (CF). Although the CF of desalination has been extensively studied, the existing literature lacks reviews exclusively for it. To help fill the research gap, this study presents a comprehensive and up-to-date review of the CF of seawater desalination technologies, including the conventional reverse osmosis (RO), multi-stage flash (MSF), multi-effect distillation (MED), electrodialysis (ED), and mechanical vapor compression (MVC), and the emerging membrane distillation (MD) and humidification–dehumidification (HDH). To our knowledge, this is the first review that focuses on the CF of seawater desalination. A general procedure for assessing the CF of a desalination system is discussed. The CF data of 211 scenarios from 34 studies published from 2004 to 2023 are reviewed and analyzed, with special focuses on the CF of different technologies, the roles of different life-cycle phases and material/energy flows, and the mitigation measures. The results highlight the CF advantage of RO and low-carbon heat-driven MSF, MED, and MD, and emphasize the dominant role of the operational energy consumption (the amount, the form, and especially the source of the energy) in the CF of desalination. This review improves the understanding of the CF of seawater desalination technologies and of the ways to reduce it.


  • Open Access

    An experimental study of solar thermal vacuum membrane distillation desalination

    by Yongqing Wang, Zhilong Xu, Noam Lior, Hui Zeng

    An experimental desalination system coupling a vacuum membrane distillation (VMD) unit and a vacuum tube solar heat collection (SHC) unit was developed and tested. The parametric sensitivity of the VMD unit performance was investigated first using an electric heater as the heat source, and then the whole system was examined using solar heat. It was revealed that hot feed temperatures higher than 65°C and cold-side absolute pressure lower than 0.02 MPa are favorable for high trans-membrane flux. The startup time of the SHC-VMD system was very short, less than 10 min. The VMD unit ran intermittently for 305 h in five months, individually or together with the solar heat system, showing good suitability to unsteady solar energy and to the intermittent off-and-on operation mode. The average trans-membrane flux in the experiments of SHC-VMD combined system was about 4 kg/(m2 h), and the specific heat consumption was around 750 kWh/m3.


  • Combined Desalination and Refrigeration Systems Driven by Low-Grade Heat

    by Yongqing Wang, Noam Lior

    There is often a need for both water desalination and cooling (refrigeration/air-conditioning). The cooling can be used to significantly raise system efficiency by compressor inlet cooling in a dual-purpose power-generation and desalination system using gas turbines, or simply to supply refrigeration or air conditioning beside fresh water. Motivated by the good synergetic potential of energy/exergy utilization through the combination of the LiBr-H2O refrigeration unit, LiBr-H2O heat pump, and low-temperature multi-effect evaporation desalter, two combined refrigeration and water systems, ARHP-MEE (Absorption Refrigeration Heat Pump and Multi-Effect Evaporation desalter) system and ARHP-AHP-MEE (Absorption Refrigeration Heat Pump + Absorption Heat Pump + Multi-Effect Evaporation desalter) system, driven by low-grade heat were configured, modeled and analyzed in detail in the paper. Typically, driving steam with saturation pressure of 0.15–0.35 MPa and correspondingly saturation temperature of 111.4–138.9°C is applicable to run the systems. The main results are: (1) the combined systems have good synergy, with an energy saving rate of 42% in a case study of ARHP-MEE; (2) the refrigeration-heat cogenerated ARHP subsystem is the main reason for the synergy, where the coefficient of performance is around 1.6 and exergy efficiency above 60% when driven by 0.25 MPa saturated steam; (3) at the cost of a more complex configuration, the ARHP-AHP-MEE system has the ability of varying its outputs in very wide range, offering good flexibility on design and operation; (4) the ARHP-MEE system is predicted to have good economics, and its outputs can be varied in a wide range but not independently because their ratio remains almost constant. A parametric analysis was also performed for the ARHP-MEE, further improving the understanding of the system performance.