Noam Lior
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Noam Lior has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
Hassan S. Al-Sharqawi
Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, 297 Towne Building, 220 South 33rd Street, Philadelphia, PA 19104-6315, USA
2 shared publicationsMengying Li
University of Pennsylvania, Department of Mechanical Engineering and Applied Mechanics, Philadelphia, PA 19104-6315, USA
2 shared publicationsMirjana Radovanović
Educons University
2 shared publications- Yongqing Wang
Jimei University College of Marine Equipment and Mechanical Engineering, Key Laboratory of Ocean Renewable Energy Equipment of Fujian Province, Key Laboratory of Energy Cleaning Utilization and Development of Fujian Province
2 shared publications - Alberto Mirandola
Fellow ASME Professor Department of Industrial Engineering, University of Padova, Via Venezia 1, Padova 35131, Italy
1 shared publication - Aleksander Zidanšek
Jožef Stefan International Postgraduate School, Jamova cesta 39, SI-1000 Ljubljana, Slovenia
1 shared publication
Latest Publications
- Open Access
Thermodynamic Analysis of a Solid Oxide Fuel Cell Based Combined Cooling, Heating, and Power System Integrated with Biomass Gasification
A novel cooling, heating, and power system integrated with a solid oxide fuel cell and biomass gasification was proposed and analyzed. The thermodynamic models of components and evaluation indicators were established to present energetic and exergetic analysis. After the validations of thermodynamic models, the system performances under design work conditions were evaluated. The proposed system’s electrical, energy, and exergy efficiencies reached up to 52.6%, 68.0%, and 43.9%, respectively. The gasifier and fuel cell stack were the most significant components of exergy destruction in this system, accounting for 41.0% and 15.1%, respectively, which were primarily caused by the gasification and electrochemical reactions’ irreversibility. The influences of the key parameters of the ratio of steam to biomass mass flow rate (S/B), the biomass flow rate (Mbio), and the temperature and pressure of the fuel cell (Top and Psofc) on system energy performances were analyzed: doubling S/B (from 0.5 to 1.0) reduced the energy efficiency by 5.3%, while increasing the electrical efficiency by 4.6% (from 52.6% to 55.0%) and raising the biomass mass flow rate by 40% increased the energy and exergy efficiencies by 2.4% and 2.1%, respectively. When raising the SOFC operating temperature by 31.3%, the energy and exergy efficiencies rose by 61.2% (from 50.0% to 80.6%) and 45.1% (from 32.8% to 47.6%), respectively, but this likely would result in a higher operating cost. Increasing the SOFC pressure from 2 to 7 bar increased the electrical efficiency by 10.6%, but additional energy for pumping and compression was consumed.
Open AccessThermodynamic Analysis of a Solid Oxide Fuel Cell Based Combined Cooling, Heating, and Power System Integrated with Biomass Gasification
A novel cooling, heating, and power system integrated with a solid oxide fuel cell and biomass gasification was proposed and analyzed. The thermodynamic models of components and evaluation indicators were established to present energetic and exergetic analysis. After the validations of thermodynamic models, the system performances under design work conditions were evaluated. The proposed system’s electrical, energy, and exergy efficiencies reached up to 52.6%, 68.0%, and 43.9%, respectively. The gasifier and fuel cell stack were the most significant components of exergy destruction in this system, accounting for 41.0% and 15.1%, respectively, which were primarily caused by the gasification and electrochemical reactions’ irreversibility. The influences of the key parameters of the ratio of steam to biomass mass flow rate (S/B), the biomass flow rate (Mbio), and the temperature and pressure of the fuel cell (Top and Psofc) on system energy performances were analyzed: doubling S/B (from 0.5 to 1.0) reduced the energy efficiency by 5.3%, while increasing the electrical efficiency by 4.6% (from 52.6% to 55.0%) and raising the biomass mass flow rate by 40% increased the energy and exergy efficiencies by 2.4% and 2.1%, respectively. When raising the SOFC operating temperature by 31.3%, the energy and exergy efficiencies rose by 61.2% (from 50.0% to 80.6%) and 45.1% (from 32.8% to 47.6%), respectively, but this likely would result in a higher operating cost. Increasing the SOFC pressure from 2 to 7 bar increased the electrical efficiency by 10.6%, but additional energy for pumping and compression was consumed.
- 3 April 2018
- Published by Springer Nature in Sustainability Science
- Vol. 13 (4) , 973-1000
Comparing sustainable development measurement based on different priorities: sustainable development goals, economics, and human well-being—Southeast Europe case
- 3 April 2018
- Published by Springer Nature in Sustainability Science
- Vol. 13 (4) , 973-1000
Comparing sustainable development measurement based on different priorities: sustainable development goals, economics, and human well-being—Southeast Europe case
- 20 March 2017
- Published by Wiley in Sustainable Development
- Vol. 25 (6) , 580-594
Sustainable economic–environmental planning in Southeast Europe – beyond‐GDP and climate change emphases
This study's objectives are (1) application of a quantitatively sound approach to the evaluation of economic and environmental sustainability for 10 Southeast Europe (SEE) countries, including comparison with the developed countries of Germany, France and the Russian Federation, and (2) evaluation of the effects of chosen sustainability indicator weights, especially of the GDP‐PPP, climate change and the income equality Gini index, as sustainability parameters. One applied scenario is with the level of sustainable economic development assessed by a traditional approach, based on high weight of GDP‐PPP, and another assigns lesser weight to the GDP‐PPP and higher weight to natural wealth and income equality, i.e. a ‘beyond‐GDP’ goal. The sustainability of environmental development was determined by a common approach based on high importance of climate change indicators and an approach, perhaps more suitable for developing countries of SEE, that gives higher weight to their agriculture, forestation and energy usage. Assigning higher weights to natural wealth and social equality encouragingly demonstrated that this results in the same or higher sustainability rankings for the SEE countries, and for some even higher than those of the developed countries. Developing countries that have relatively low GHG emissions and energy use, and GDP well above the poverty level, should consider basing their sustainable development on raising the relative weights for natural wealth and income equality, and lowering it for the GDP. Methodology recommendations are offered to sustainable development planners and policy‐makers. Uniformity and scientific consensus‐based standardization of sustainability analysis methodology are critically needed. Copyright © 2017 John Wiley & Sons, Ltd and ERP Environment
- 20 March 2017
- Published by Wiley in Sustainable Development
- Vol. 25 (6) , 580-594
Sustainable economic–environmental planning in Southeast Europe – beyond‐GDP and climate change emphases
This study's objectives are (1) application of a quantitatively sound approach to the evaluation of economic and environmental sustainability for 10 Southeast Europe (SEE) countries, including comparison with the developed countries of Germany, France and the Russian Federation, and (2) evaluation of the effects of chosen sustainability indicator weights, especially of the GDP‐PPP, climate change and the income equality Gini index, as sustainability parameters. One applied scenario is with the level of sustainable economic development assessed by a traditional approach, based on high weight of GDP‐PPP, and another assigns lesser weight to the GDP‐PPP and higher weight to natural wealth and income equality, i.e. a ‘beyond‐GDP’ goal. The sustainability of environmental development was determined by a common approach based on high importance of climate change indicators and an approach, perhaps more suitable for developing countries of SEE, that gives higher weight to their agriculture, forestation and energy usage. Assigning higher weights to natural wealth and social equality encouragingly demonstrated that this results in the same or higher sustainability rankings for the SEE countries, and for some even higher than those of the developed countries. Developing countries that have relatively low GHG emissions and energy use, and GDP well above the poverty level, should consider basing their sustainable development on raising the relative weights for natural wealth and income equality, and lowering it for the GDP. Methodology recommendations are offered to sustainable development planners and policy‐makers. Uniformity and scientific consensus‐based standardization of sustainability analysis methodology are critically needed. Copyright © 2017 John Wiley & Sons, Ltd and ERP Environment
- 14 September 2016
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 138 (6) , 061603
Performance Study and Energy Saving Process Analysis of Hybrid Absorption-Compression Refrigeration Cycles
In an attempt to improve the performance of hybrid absorption and mechanical vapor compression refrigeration systems and to determine the fundamental reasons for such improvements, two configurations of the hybrid refrigeration cycle with a booster compressor at different positions of the cycle (between the evaporation and the absorber, or between the generator and the condenser) are simulated and analyzed. The interrelation between the two subcycles and the hybridization principle have been explored and clarified. An NH3/H2O-based hybrid cycle is the basis of this simulation. It was found that (1) the hybrid cycle performance is mainly governed by the interaction between its two subcycles of mechanical compression and thermal compression and their respective energy efficiencies, and (2) the hybrid cycle primary energy-based coefficient of performance (COP) was higher by up to 15% (without internal heat recuperation) as compared with the nonhybrid absorption cycle, (3) in comparison with the nonhybrid absorption and vapor compression cycles working in the same temperature regions, the more efficient use of low-temperature heat by cascade utilization of the two energy inputs (heat rate and mechanical power) with different energy quality, and the enhanced refrigeration ability of low-temperature heat are the basic reasons for the hybrid cycle performance improvement and significant energy saving, (4) the hybrid cycle achieves an exergy efficiency of 36.5%, which is 27% higher than that of the absorption cycle, and 4.5% higher than the vapor compression cycle, achieving a thermal-driving exergy efficiency of 37.5% and mechanical work saving ratio up to 64%.
- 14 September 2016
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 138 (6) , 061603
Performance Study and Energy Saving Process Analysis of Hybrid Absorption-Compression Refrigeration Cycles
In an attempt to improve the performance of hybrid absorption and mechanical vapor compression refrigeration systems and to determine the fundamental reasons for such improvements, two configurations of the hybrid refrigeration cycle with a booster compressor at different positions of the cycle (between the evaporation and the absorber, or between the generator and the condenser) are simulated and analyzed. The interrelation between the two subcycles and the hybridization principle have been explored and clarified. An NH3/H2O-based hybrid cycle is the basis of this simulation. It was found that (1) the hybrid cycle performance is mainly governed by the interaction between its two subcycles of mechanical compression and thermal compression and their respective energy efficiencies, and (2) the hybrid cycle primary energy-based coefficient of performance (COP) was higher by up to 15% (without internal heat recuperation) as compared with the nonhybrid absorption cycle, (3) in comparison with the nonhybrid absorption and vapor compression cycles working in the same temperature regions, the more efficient use of low-temperature heat by cascade utilization of the two energy inputs (heat rate and mechanical power) with different energy quality, and the enhanced refrigeration ability of low-temperature heat are the basic reasons for the hybrid cycle performance improvement and significant energy saving, (4) the hybrid cycle achieves an exergy efficiency of 36.5%, which is 27% higher than that of the absorption cycle, and 4.5% higher than the vapor compression cycle, achieving a thermal-driving exergy efficiency of 37.5% and mechanical work saving ratio up to 64%.
- Open Access
- 26 February 2016
- Published by Elsevier in Desalination and Water Treatment
- Vol. 57 (43) , 20093-20140
Critical review of membrane distillation performance criteria
The number of published papers about membrane distillation (MD) has been growing exponentially and many evaluation and performance criteria are used to measure it; but, there is no established tradition or evaluation standard for them. This makes the evaluations difficult to compare, or even incomplete. This paper presents therefore a comprehensive critical review and clarification of the major evaluation criteria for the MD components and systems, aimed to offer some recommendations for their more uniform usage, provide clearer quantitative goals in research and industrial use, and to facilitate more correct and honest representations and comparisons. General description and models of MD are presented first, followed by criteria used to characterize the membranes, and performance criteria to evaluate the distillate production rate, product quality, energy efficiency (including conventional energy performance criteria and exergy performance criteria), transport process, and long-time operation. Since exergy analysis of the process is less known, a detailed example is presented.
- 26 February 2016
- Published by Elsevier in Desalination and Water Treatment
- Vol. 57 (43) , 20093-20140
Open AccessCritical review of membrane distillation performance criteria
The number of published papers about membrane distillation (MD) has been growing exponentially and many evaluation and performance criteria are used to measure it; but, there is no established tradition or evaluation standard for them. This makes the evaluations difficult to compare, or even incomplete. This paper presents therefore a comprehensive critical review and clarification of the major evaluation criteria for the MD components and systems, aimed to offer some recommendations for their more uniform usage, provide clearer quantitative goals in research and industrial use, and to facilitate more correct and honest representations and comparisons. General description and models of MD are presented first, followed by criteria used to characterize the membranes, and performance criteria to evaluate the distillate production rate, product quality, energy efficiency (including conventional energy performance criteria and exergy performance criteria), transport process, and long-time operation. Since exergy analysis of the process is less known, a detailed example is presented.
- 1 February 2016
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 138 (6) , 061601
Exergy, Energy, and Gas Flow Analysis of Hydrofractured Shale Gas Extraction
The objectives of this study are to (a) evaluate the exergy and energy demand for constructing a hydrofractured shale gas well and determine its typical exergy and energy returns on investment (ExROI and EROI), and (b) compute the gas flow and intrinsic exergy analysis in the shale gas matrix and created fractures. An exergy system analysis of construction of a typical U.S. shale gas well, which includes the processes and materials exergies (embodied exergy) for drilling, casing and cementing, and hydrofracturing (“fracking”), was conducted. A gas flow and intrinsic exergy numerical simulation and analysis in a gas-containing hydrofractured shale reservoir with its formed fractures was then performed, resulting in the time- and two-dimensional (2D) space-dependent pressure, velocity, and exergy loss fields in the matrix and fractures. The key results of the system analysis show that the total exergy consumption for constructing the typical hydrofractured shale gas well is 35.8 TJ, 49% of which is used for all the drilling needed for the well and casings and further 48% are used for the hydrofracturing. The embodied exergy of all construction materials is about 9.8% of the total exergy consumption. The ExROI for the typical range of shale gas wells in the U.S. was found to be 7.3–87.8. The embodied energy of manufactured materials is significantly larger than their exergy, so the total energy consumption is about 8% higher than the exergy consumption. The intrinsic exergy analysis showed, as expected, very slow (order of 10−9 m/s) gas flow velocities through the matrix, and consequently very small flow exergy losses. It clearly points to the desirability of exploring fracking methods that increase the number and length of effective fractures, and they increase well productivity with a relatively small flow exergy penalty.
- 1 February 2016
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 138 (6) , 061601
Exergy, Energy, and Gas Flow Analysis of Hydrofractured Shale Gas Extraction
The objectives of this study are to (a) evaluate the exergy and energy demand for constructing a hydrofractured shale gas well and determine its typical exergy and energy returns on investment (ExROI and EROI), and (b) compute the gas flow and intrinsic exergy analysis in the shale gas matrix and created fractures. An exergy system analysis of construction of a typical U.S. shale gas well, which includes the processes and materials exergies (embodied exergy) for drilling, casing and cementing, and hydrofracturing (“fracking”), was conducted. A gas flow and intrinsic exergy numerical simulation and analysis in a gas-containing hydrofractured shale reservoir with its formed fractures was then performed, resulting in the time- and two-dimensional (2D) space-dependent pressure, velocity, and exergy loss fields in the matrix and fractures. The key results of the system analysis show that the total exergy consumption for constructing the typical hydrofractured shale gas well is 35.8 TJ, 49% of which is used for all the drilling needed for the well and casings and further 48% are used for the hydrofracturing. The embodied exergy of all construction materials is about 9.8% of the total exergy consumption. The ExROI for the typical range of shale gas wells in the U.S. was found to be 7.3–87.8. The embodied energy of manufactured materials is significantly larger than their exergy, so the total energy consumption is about 8% higher than the exergy consumption. The intrinsic exergy analysis showed, as expected, very slow (order of 10−9 m/s) gas flow velocities through the matrix, and consequently very small flow exergy losses. It clearly points to the desirability of exploring fracking methods that increase the number and length of effective fractures, and they increase well productivity with a relatively small flow exergy penalty.
- 1 July 2015
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 137 (4) , 041203
Analysis of Hydraulic Fracturing and Reservoir Performance in Enhanced Geothermal Systems
Analyses of fracturing and thermal performance of fractured reservoirs in engineered geothermal system (EGS) are extended from a depth of 5 km to 10 km, and models for flow and heat transfer in EGS are improved. Effects of the geofluid flow direction choice, distance between fractures, fracture width, permeability, radius, and number of fractures, on reservoir heat drawdown time are computed. The number of fractures and fracture radius for desired reservoir thermal drawdown rates are recommended. A simplified model for reservoir hydraulic fracturing energy consumption is developed, indicating it to be 51.8–99.6 MJ per m3 fracture for depths of 5–10 km.
- 1 July 2015
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 137 (4) , 041203
Analysis of Hydraulic Fracturing and Reservoir Performance in Enhanced Geothermal Systems
Analyses of fracturing and thermal performance of fractured reservoirs in engineered geothermal system (EGS) are extended from a depth of 5 km to 10 km, and models for flow and heat transfer in EGS are improved. Effects of the geofluid flow direction choice, distance between fractures, fracture width, permeability, radius, and number of fractures, on reservoir heat drawdown time are computed. The number of fractures and fracture radius for desired reservoir thermal drawdown rates are recommended. A simplified model for reservoir hydraulic fracturing energy consumption is developed, indicating it to be 51.8–99.6 MJ per m3 fracture for depths of 5–10 km.
- Open Access
- 1 January 2015
- Published by Elsevier in Desalination and Water Treatment
- Vol. 53 (4) , 887-897
An experimental study of solar thermal vacuum membrane distillation desalination
An experimental desalination system coupling a vacuum membrane distillation (VMD) unit and a vacuum tube solar heat collection (SHC) unit was developed and tested. The parametric sensitivity of the VMD unit performance was investigated first using an electric heater as the heat source, and then the whole system was examined using solar heat. It was revealed that hot feed temperatures higher than 65°C and cold-side absolute pressure lower than 0.02 MPa are favorable for high trans-membrane flux. The startup time of the SHC-VMD system was very short, less than 10 min. The VMD unit ran intermittently for 305 h in five months, individually or together with the solar heat system, showing good suitability to unsteady solar energy and to the intermittent off-and-on operation mode. The average trans-membrane flux in the experiments of SHC-VMD combined system was about 4 kg/(m2 h), and the specific heat consumption was around 750 kWh/m3.
- 1 January 2015
- Published by Elsevier in Desalination and Water Treatment
- Vol. 53 (4) , 887-897
Open AccessAn experimental study of solar thermal vacuum membrane distillation desalination
An experimental desalination system coupling a vacuum membrane distillation (VMD) unit and a vacuum tube solar heat collection (SHC) unit was developed and tested. The parametric sensitivity of the VMD unit performance was investigated first using an electric heater as the heat source, and then the whole system was examined using solar heat. It was revealed that hot feed temperatures higher than 65°C and cold-side absolute pressure lower than 0.02 MPa are favorable for high trans-membrane flux. The startup time of the SHC-VMD system was very short, less than 10 min. The VMD unit ran intermittently for 305 h in five months, individually or together with the solar heat system, showing good suitability to unsteady solar energy and to the intermittent off-and-on operation mode. The average trans-membrane flux in the experiments of SHC-VMD combined system was about 4 kg/(m2 h), and the specific heat consumption was around 750 kWh/m3.
- Open Access
Comparative Analysis of Power Plant Options for Enhanced Geothermal Systems (EGS)
Enhanced geothermal systems (EGS) extract heat from underground hot dry rock (HDR) by first fracturing the HDR and then circulating a geofluid (typically water) into it and bringing the heated geofluid to a power plant to generate electricity. This study focuses on analysis, examination, and comparison of leading geothermal power plant configurations with a geofluid temperature from 200 to 800 °C, and also analyzes the embodied energy of EGS surface power plants. The power generation analysis is focused on flash type cycles for using subcritical geofluid (374 °C). Key findings of this study include: (i) double-flash plants have 24.3%–29.0% higher geofluid effectiveness than single-flash ones, and 3%–10% lower specific embodied energy; (ii) the expansion type plants have geofluid effectiveness > 750 kJ/kg, significantly higher than flash type plants (geofluid effectiveness < 300 kJ/kg) and the specific embodied energy is lower; (iii) to increase the turbine outlet vapor fraction from 0.75 to 0.90, we include superheating by geofluid but that reduces the geofluid effectiveness by 28.3%; (iv) for geofluid temperatures above 650 °C, double-expansion plants have a 2% higher geofluid effectiveness and 5%–8% lower specific embodied energy than single-expansion ones.
Open AccessComparative Analysis of Power Plant Options for Enhanced Geothermal Systems (EGS)
Enhanced geothermal systems (EGS) extract heat from underground hot dry rock (HDR) by first fracturing the HDR and then circulating a geofluid (typically water) into it and bringing the heated geofluid to a power plant to generate electricity. This study focuses on analysis, examination, and comparison of leading geothermal power plant configurations with a geofluid temperature from 200 to 800 °C, and also analyzes the embodied energy of EGS surface power plants. The power generation analysis is focused on flash type cycles for using subcritical geofluid (374 °C). Key findings of this study include: (i) double-flash plants have 24.3%–29.0% higher geofluid effectiveness than single-flash ones, and 3%–10% lower specific embodied energy; (ii) the expansion type plants have geofluid effectiveness > 750 kJ/kg, significantly higher than flash type plants (geofluid effectiveness < 300 kJ/kg) and the specific embodied energy is lower; (iii) to increase the turbine outlet vapor fraction from 0.75 to 0.90, we include superheating by geofluid but that reduces the geofluid effectiveness by 28.3%; (iv) for geofluid temperatures above 650 °C, double-expansion plants have a 2% higher geofluid effectiveness and 5%–8% lower specific embodied energy than single-expansion ones.