FLFrank Lampe

Frank Lampe

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Frank Lampe has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Effects of Body Position on Pelvic Tilt Angles Measured with a Smartphone-Based Navigated Ultrasound System in Symptom-Free Young Adults

    by Carlos Marques, Tobias Martin, Franziska Fiedler, Mathias Weber, Frank Lampe, Viktor Breul, Josef Kozak

    The study aimed to investigate whether pelvic tilt (PT) angles differ between the supine and upright position in symptom-free young adults. Additionally, the concurrent validity of the measurement system was tested on a pelvis phantom against a digital inclinometer. A new smartphone-based navigated ultrasound system was used to perform the measurements. The sample consisted of 12 symptom-free young adults. A multivariate regression model was used to analyze the data. The subjects’ pelvis in supine position was significantly more tilted anteriorly (mean PT = −7.3°, 95% C.I.: −10.6 to −3.9) than in upright position (mean PT = 0.8°, 95% C.I.: −2.5 to 4.1) (mean. diff. 8.1°; p < 0.001). Rater and trial order had no significant effects on the measured PT angles (p = 0.5). The accuracy of the system when measuring PT angles on the pelvis phantom was 0.3° (0.1° to 0.7°) and 0.2° (−0.09° to 0.6°) for the supine and upright positions respectively. Pelvic tilt angles differed significantly between the supine and the upright position in symptom-free young adults. Concurrent validity showed no differences for measurements in the upright position and small (under 0.4°) significant differences for measurements in the supine position.


  • No improvement in reducing outliers in coronal axis alignment with patient-specific instrumentation

    by Uwe Maus, Carlos J. Marques, David Scheunemann, Frank Lampe, Djordje Lazovic, Hagen Hommel, Dennis Vogel, Martin Haunschild, Tilman Pfitzner

    Patient-specific instrumentation (PSI) uses 3D preoperative imaging to produce individualized cutting blocks specific to patients’ anatomy and according to the preoperative plan with the aim to reduce the number of mechanical leg alignment (MLA) outliers, to improve implant positioning and to decrease surgery time. The primary purpose of this study was to investigate the efficacy of a specific PSI in comparison with standard instrumentation (SI) in reducing the number of MLA outliers. It was hypothesized that the number of MLA outliers would be significantly lower in the PSI group.


  • Open Access

    Surgically modifiable factors measured by computer-navigation together with patient-specific factors predict knee society score after total knee arthroplasty

    by Frank Lampe, Franziska Fiedler, Carlos J. Marques, Anusch Sufi-Siavach, Georg Matziolis

    The purpose was to investigate whether patient-specific factors (PSF) and surgically modifiable factors (SMF), measured by means of a computer-assisted navigation system, can predict the Knee Society Scores (KSS) after total knee arthroplasty (TKA). Data from 99 patients collected during a randomized clinical trial were used for this secondary data analysis. The KSS scores of the patients were measured preoperatively and at 4-years follow-up. Multiple regression analyses were performed to investigate which combination of variables would be the best to predict the 4-years KSS scores. When considering SMF alone the combination of four of them significantly predicted the 4-years KSS-F score (p = 0.009), explaining 18 % of its variation. When considering only PSF the combination of age and body weight significantly predicted the 4-years KSS-F (p = 0.008), explaining 11 % of its variation. When considering both groups of predictors simultaneously the combination of three PSF and two SMF significantly predicted the 4-years KSS-F (p = 0.007), explaining 20 % of its variation. Younger age, better preoperative KSS-F scores and lower BMI before surgery, a positive tibial component slope and small changes in femoral offset were predictors of better KSS-F scores at 4-years.


  • Open Access

    No differences in clinical outcomes between fixed‐ and mobile‐bearing computer‐assisted total knee arthroplasties and no correlations between navigation data and clinical scores

    by Carlos J. Marques, Sandra Daniel, Anusch Sufi‐Siavach, Frank Lampe

    Purpose: The theoretical advantages of mobile‐bearing (MB) designs over the conventional fixed bearings (FBs) for total knee arthroplasty (TKA) have not been proved yet through clinical studies. The aim of the study was to test whether the MB design has advantages in terms of better clinical outcomes when compared to FB. Furthermore, the relationships between intra‐operative obtained implant positioning data and the clinical scores were analysed.Methods: A total of 99 patients were randomized into the FB or the MB group. All patients received the same posterior cruciate retaining implants and were operated with the use of a computer‐assisted navigation system. The clinical outcomes of both groups were compared pre‐operatively, at 1 year, and at a mean follow‐up time of 4 years after surgery.Results: The MB implants showed no advantages over the FB when comparing the Knee Society Scores, the Oxford Score, the range of movement (ROM) and pain intensity of the patients in both groups at 1 and 4 years after surgery. There were no relationships between the computer navigation data and the clinical scores.Conclusions: In view of the 4‐year results, there is no evidence to support the recommendation of one design over the other in terms of better clinical outcome scores, higher ROM or lower pain rates. Long‐term follow‐up results may be necessary, including survival rates. Further research comparing different TKA designs should also include standardized performance‐based tests.Level of evidence: Prospective study (Randomized controlled trial with adequate statistical power to detect differences), Level I.


  • Open Access

    One Year After Navigated Total Knee Replacement, No Clinically Relevant Difference Found Between Fixed Bearing and Mobile Bearing Knee Replacement in a Double-Blind Randomized Controlled Trial

    by Frank Lampe, Anusch Sufi-Siavach, Karina E Bohlen, Ekkehard Hille, Sebastian P.M Dries

    Background: The mobile bearing designs have not yet been shown to improve clinical outcome of total knee arthroplasty (TKA). In this prospective randomized study, we compared the short-term clinical results of a mobile bearing implant with those of the fixed bearing version of the same implant. Methods: We randomized 100 knees into two double-blind groups who received either the fixed (FB, 52 knees) or the mobile bearing (MB, 48 knees) version of the same implant. We used navigation to standardize the surgical technique. For up to one year, we recorded the Knee Society (KSS) and Oxford (OXF) scores. We performed an exploratory analysis of variance (ANOVA) to determine the influence of baseline scores as covariate and the extent of improvement in clinical outcome over time. Results: After one year, we did not detect any statistically significant difference between the two groups. The KSS scores differed by 2 points, the OXF scores by 1.1 points. Conclusion: Even with identical geometry of implant surfaces and a navigated surgical technique, first-year results do not support a preference for either a fixed or a mobile design.


    • 1 October 2007
      • Vol. 30, S107-11

    Accuracy of implant alignment and early results after minimally invasive vs conventional OrthoPilot-navigated Columbus TKA.

    by Frank Lampe, Karina Bohlen, Sebastian P M Dries, Anusch Sufi-Siavach, Ekkehard Hille

    The goal of this study was to evaluate potential risks and benefits of minimally invasive vs conventional approaches in navigated total knee arthroplasty (TKA) in 50 patients. Preoperatively, no statistically significant differences between the two groups were found for deformity, range of motion (ROM), clinical scores, and ligament stability in the native joint or after prosthesis implantation measurements intraoperatively. Postoperatively, there were no significant differences between the two groups for deformity and clinical scores. In contrast, significantly less pain according to VAS measures and quicker improvements in ROM during the first 10 postoperative days were experienced in the minimally invasive group. Complication rates were similar in both groups. According to our results, minimally invasive navigated TKA is characterized by high implant positioning accuracy, soft tissue management quality, and complication rates similar to those for conventional approaches. Compared with the conventional approach, minimally invasive TKA provides superior functional results and less pain in the early postoperative period.