Katharina Schaper
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Katharina Schaper has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Frank Krummenauer
Institute for Medical Biometry and Epidemiology, Witten/Herdecke University, Faculty of Health, Alfred-Herrhausen.Straße 50, 58448, Witten, Germany
2 shared publications - Wolfgang. H. Arnold
Department of Biological and Material Sciences in Dentistry, School of Dentistry, Faculty of Health, Witten/Herdecke University, 58455 Witten, Germany
2 shared publications - Alexander Valta
Point Dr. Prünte und Partner Bergpfad 7, 59423 Unna, Germany
1 shared publication - Andrea Meurer
Dr. Rolf M. Schwiete Research Unit for Osteoarthritis, Orthopedic University Hospital Friedrichsheim gGmbH, 60528 Frankfurt/Main, Germany
1 shared publication - Andree Piwowarczyk
Department of Prosthodontics, School of Dentistry, Faculty of Health, Witten/Herdecke University, 58455 Witten, Germany
1 shared publication - Bassel Haddad
Department of Orthodontics, University of Witten/Herdecke, Dental Clinic, Alfred-Herrhausen Str. 45, 58455, Witten, Germany
1 shared publication
Latest Publications
- Open Access
- 25 September 2015
- Published by Springer Nature in Head & Face Medicine
- Vol. 11 (1) , 1-7
Enamel surface alterations after repeated conditioning with HCl
The aim of this study was to investigate the influence of etching time with 15 % hydrochloric acid (HCl) on the enamel surface destruction by studying the resulting roughness and erosion depth. The vestibular surfaces of 12 extracted, caries free human incisors were divided into four quadrants, and each quadrant was etched with 15 % HCl for different numbers of etching cycles (1×2, 2×2, 3×2 and 4×2 min). Surface roughness and erosion depth were measured quantitatively with optical profilometry, and the surface morphology was imaged with scanning electron microscopy (SEM). After two minutes of 15 % HCl application a median enamel substance loss of 34.02 μm was observed. Lengthening of etching time (2×2, 3×2 and 4×2 min) resulted in significantly increase in erosion depth to each additionally, between 13.28 -15.16 μm (p < 0.05) ending up in a total median enamel surface loss of 77 μm. Regarding surface roughness no significant (p > 0.05) difference was found between unetched enamel and the etched enamel surfaces. Repeated 15 % HCl conditioning of the enamel surface increases the depth of the etched surface erosion. However, the total erosion depth is rather shallow and therefore negligible.
- 25 September 2015
- Published by Springer Nature in Head & Face Medicine
- Vol. 11 (1) , 1-7
Open AccessEnamel surface alterations after repeated conditioning with HCl
The aim of this study was to investigate the influence of etching time with 15 % hydrochloric acid (HCl) on the enamel surface destruction by studying the resulting roughness and erosion depth. The vestibular surfaces of 12 extracted, caries free human incisors were divided into four quadrants, and each quadrant was etched with 15 % HCl for different numbers of etching cycles (1×2, 2×2, 3×2 and 4×2 min). Surface roughness and erosion depth were measured quantitatively with optical profilometry, and the surface morphology was imaged with scanning electron microscopy (SEM). After two minutes of 15 % HCl application a median enamel substance loss of 34.02 μm was observed. Lengthening of etching time (2×2, 3×2 and 4×2 min) resulted in significantly increase in erosion depth to each additionally, between 13.28 -15.16 μm (p < 0.05) ending up in a total median enamel surface loss of 77 μm. Regarding surface roughness no significant (p > 0.05) difference was found between unetched enamel and the etched enamel surfaces. Repeated 15 % HCl conditioning of the enamel surface increases the depth of the etched surface erosion. However, the total erosion depth is rather shallow and therefore negligible.
- Open Access
Microleakage of Different Self-Adhesive Materials for Lithium Disilicate CAD/CAM Crowns
Objectives: To evaluate the microleakage and marginal gap of various luting materials after cementing ceramic crowns. Methods: Cervical margins of human molars were designed as circular chamfers. Cementation of full-contour ceramic crowns was conducted with zinc-phosphate cement (Harvard cement), resin cement (Panavia F 2.0) and self-adhesive resin cements (RelyX Unicem, BifixSE, MaxCem Elite, PermaCem2.0, G-Cem). Aging of specimens was performed in artificial saliva, at 37 °C for four weeks and thermocycling. The marginal gap was measured with a scanning electron microscope and silver precipitation within the microleakage. All data were compared statistically. Results: Independent of the margin preparation, the highest median value for microleakage was 320.2 μm (Harvard cement), and the lowest was 0 μm (Panavia F 2.0). The median value for enamel was 0 µm and for dentin 270.9 μm (p < 0.001), which was independent of the luting material. The marginal and absolute marginal gaps were not significantly different between the tested materials. There was no correlation between microleakage and the marginal gaps. Conclusion: Significant differences in microleakage were found between the tested luting materials (p < 0.05). Independent from the luting materials, the microleakage in dentin showed significantly higher values than in enamel.
Open AccessMicroleakage of Different Self-Adhesive Materials for Lithium Disilicate CAD/CAM Crowns
Objectives: To evaluate the microleakage and marginal gap of various luting materials after cementing ceramic crowns. Methods: Cervical margins of human molars were designed as circular chamfers. Cementation of full-contour ceramic crowns was conducted with zinc-phosphate cement (Harvard cement), resin cement (Panavia F 2.0) and self-adhesive resin cements (RelyX Unicem, BifixSE, MaxCem Elite, PermaCem2.0, G-Cem). Aging of specimens was performed in artificial saliva, at 37 °C for four weeks and thermocycling. The marginal gap was measured with a scanning electron microscope and silver precipitation within the microleakage. All data were compared statistically. Results: Independent of the margin preparation, the highest median value for microleakage was 320.2 μm (Harvard cement), and the lowest was 0 μm (Panavia F 2.0). The median value for enamel was 0 µm and for dentin 270.9 μm (p < 0.001), which was independent of the luting material. The marginal and absolute marginal gaps were not significantly different between the tested materials. There was no correlation between microleakage and the marginal gaps. Conclusion: Significant differences in microleakage were found between the tested luting materials (p < 0.05). Independent from the luting materials, the microleakage in dentin showed significantly higher values than in enamel.
- 11 July 2014
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 134 (9) , 1205-1210
Analysis of agreement between the German translation of the American Foot and Ankle Society’s Ankle and Hindfoot Scale (AOFAS-AHS) and the Foot Function Index in its validated German translation by Naal et al. (FFI-D)
Despite its wide use in clinical outcome measurement, there is yet no validated German language version of the AOFAS-AHS available. After finishing cross-cultural adaption of the AOFAS-AHS according to the AAOS guidelines, an analysis of agreement was carried out. This was done by means of the 18-item Foot Function Index in its validated German translation by Naal et al. (FFI-D). The results of 91 orthopedic patients as well as healthy persons in both scores were then compared intraindividually. The cohort consisted of 46 individuals with hindfoot disorders and 45 persons without any hindfoot complaints. The FFI-D-Score was linearly transformed in the range 0–100 points of the AOFAS. Encouraging correlation was then found for the patients with hindfoot disorders (Spearman’s correlation 0.73 (95 % CI 0.52–0.85); a median deviation of −2 points (interquartile range −13 points; +13 points) in patients with hindfoot disorders implied good median intraindividual score concordance. However, with 30 of these 46 patients showing score deviations beyond or below a pre-specified ±10 points range of clinically tolerable deviations, the scores cannot be considered exchangeable. Although the agreement analysis was performed for the German translation of the two questionnaires, analogous results can be expected also for other languages. It should be noted that the results do not allow for judging which of the scores is better suited to give a valid statement on patient outcome in treatment of hindfoot disorders. To verify which of these two scores is better suited to represent hindfoot-dysfunction a subsequent study using instrumental gait analysis and surface EMG is being carried out.
- 11 July 2014
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 134 (9) , 1205-1210
Analysis of agreement between the German translation of the American Foot and Ankle Society’s Ankle and Hindfoot Scale (AOFAS-AHS) and the Foot Function Index in its validated German translation by Naal et al. (FFI-D)
Despite its wide use in clinical outcome measurement, there is yet no validated German language version of the AOFAS-AHS available. After finishing cross-cultural adaption of the AOFAS-AHS according to the AAOS guidelines, an analysis of agreement was carried out. This was done by means of the 18-item Foot Function Index in its validated German translation by Naal et al. (FFI-D). The results of 91 orthopedic patients as well as healthy persons in both scores were then compared intraindividually. The cohort consisted of 46 individuals with hindfoot disorders and 45 persons without any hindfoot complaints. The FFI-D-Score was linearly transformed in the range 0–100 points of the AOFAS. Encouraging correlation was then found for the patients with hindfoot disorders (Spearman’s correlation 0.73 (95 % CI 0.52–0.85); a median deviation of −2 points (interquartile range −13 points; +13 points) in patients with hindfoot disorders implied good median intraindividual score concordance. However, with 30 of these 46 patients showing score deviations beyond or below a pre-specified ±10 points range of clinically tolerable deviations, the scores cannot be considered exchangeable. Although the agreement analysis was performed for the German translation of the two questionnaires, analogous results can be expected also for other languages. It should be noted that the results do not allow for judging which of the scores is better suited to give a valid statement on patient outcome in treatment of hindfoot disorders. To verify which of these two scores is better suited to represent hindfoot-dysfunction a subsequent study using instrumental gait analysis and surface EMG is being carried out.
- 1 January 2014
- Published by Elsevier in Zeitschrift für Evidenz, Fortbildung und Qualität im Gesundheitswesen
- Vol. 108 (10) , 618-623
Initiierung von Promotionsvorhaben während des Medizinstudiums? Retrospektive Erhebung zum Anteil zeitnah nach Studienende abgeschlossener Promotionsvorhaben zum „Dr. med.“ an der Universität Witten/Herdecke
- 1 January 2014
- Published by Elsevier in Zeitschrift für Evidenz, Fortbildung und Qualität im Gesundheitswesen
- Vol. 108 (10) , 618-623
Initiierung von Promotionsvorhaben während des Medizinstudiums? Retrospektive Erhebung zum Anteil zeitnah nach Studienende abgeschlossener Promotionsvorhaben zum „Dr. med.“ an der Universität Witten/Herdecke