M. Weidner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
M. Weidner has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
C. Hagelstein
University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University
1 shared publication- Frank Gerrit Zöllner
Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
1 shared publication K. W. Neff
University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University
1 shared publication- Katrin Zahn
Department of Pediatric Surgery, Universitätsmedizin Mannheim, Germany
1 shared publication - Lothar R. Schad
Computer Assisted Clinical Medicine, Medical Faculty Mannheim Heidelberg University Mannheim Germany
1 shared publication - Stefan Oswald Schoenberg
Department of Radiology and Nuclear Medicine, University Medical Centre Mannheim, Medical Faculty Mannheim, Heidelberg University, D-68167 Mannheim, Baden-Württemberg, Germany
1 shared publication
Latest Publications
- 20 July 2014
- Published by Springer Nature in European Radiology
- Vol. 24 (10) , 2427-2434
High temporal versus high spatial resolution in MR quantitative pulmonary perfusion imaging of two-year old children after congenital diaphragmatic hernia repair
Congenital diaphragmatic hernia (CDH) leads to lung hypoplasia. Using dynamic contrast-enhanced (DCE) MR imaging, lung perfusion can be quantified. As MR perfusion values depend on temporal resolution, we compared two protocols to investigate whether ipsilateral lung perfusion is impaired after CDH, whether there are protocol-dependent differences, and which protocol is preferred. DCE-MRI was performed in 36 2-year old children after CDH on a 3 T MRI system; protocol A (n = 18) based on a high spatial (3.0 s; voxel: 1.25 mm3) and protocol B (n = 18) on a high temporal resolution (1.5 s; voxel: 2 mm3). Pulmonary blood flow (PBF), pulmonary blood volume (PBV), mean transit time (MTT), and peak-contrast-to-noise-ratio (PCNR) were quantified. PBF was reduced ipsilaterally, with ipsilateral PBF of 45 ± 26 ml/100 ml/min to contralateral PBF of 63 ± 28 ml/100 ml/min (p = 0.0016) for protocol A; and for protocol B, side differences were equivalent (ipsilateral PBF = 62 ± 24 vs. contralateral PBF = 85 ± 30 ml/100 ml/min; p = 0.0034). PCNR was higher for protocol B (30 ± 18 vs. 20 ± 9; p = 0.0294). Protocol B showed higher values of PBF in comparison to protocol A (p always Quantitative lung perfusion parameters depend on temporal and spatial resolution. • Reduction of lung perfusion in CDH can be measured with different MR protocols. • Temporal resolution of 1.5 s with spatial resolution of 2 mm 3 is suitable.
- 20 July 2014
- Published by Springer Nature in European Radiology
- Vol. 24 (10) , 2427-2434
High temporal versus high spatial resolution in MR quantitative pulmonary perfusion imaging of two-year old children after congenital diaphragmatic hernia repair
Congenital diaphragmatic hernia (CDH) leads to lung hypoplasia. Using dynamic contrast-enhanced (DCE) MR imaging, lung perfusion can be quantified. As MR perfusion values depend on temporal resolution, we compared two protocols to investigate whether ipsilateral lung perfusion is impaired after CDH, whether there are protocol-dependent differences, and which protocol is preferred. DCE-MRI was performed in 36 2-year old children after CDH on a 3 T MRI system; protocol A (n = 18) based on a high spatial (3.0 s; voxel: 1.25 mm3) and protocol B (n = 18) on a high temporal resolution (1.5 s; voxel: 2 mm3). Pulmonary blood flow (PBF), pulmonary blood volume (PBV), mean transit time (MTT), and peak-contrast-to-noise-ratio (PCNR) were quantified. PBF was reduced ipsilaterally, with ipsilateral PBF of 45 ± 26 ml/100 ml/min to contralateral PBF of 63 ± 28 ml/100 ml/min (p = 0.0016) for protocol A; and for protocol B, side differences were equivalent (ipsilateral PBF = 62 ± 24 vs. contralateral PBF = 85 ± 30 ml/100 ml/min; p = 0.0034). PCNR was higher for protocol B (30 ± 18 vs. 20 ± 9; p = 0.0294). Protocol B showed higher values of PBF in comparison to protocol A (p always Quantitative lung perfusion parameters depend on temporal and spatial resolution. • Reduction of lung perfusion in CDH can be measured with different MR protocols. • Temporal resolution of 1.5 s with spatial resolution of 2 mm 3 is suitable.